• 제목/요약/키워드: configuration of ties

검색결과 15건 처리시간 0.019초

띠철근 기근 형태에 따른 철근콘크리트 기둥의 휨 거동 에 관한 연구 (A Study on Flexural Behavior of R.C. Columns with the configuration of Lateral Ties)

  • 조세용;양근혁;이영호;정헌수
    • 콘크리트학회논문집
    • /
    • 제12권1호
    • /
    • pp.53-60
    • /
    • 2000
  • The objective of this study is to investigate the flexural behavior of reinforced concrete columns confined by lateral ties. This test was carried on the twelve reinforced concrete columns subjected to lateral and constant axial loads. The main experimental variables are concrete strength, the configuration of lateral ties, and the amount of lateral ties. Test results indicated that the steel configuration in column sections plays an important role in column behavior, and a proper configuration of lateral ties can obtain more ductile by the reduction of the space of lateral ties. Also, this experiment show that the utlization of high-strength concrete in columns properly designed on ACI Code takes less ductile. Therefore, we can conclude that the design of high-strength concrete columns under high axial loads requires more lateral ties than ACI Code.

띠철근으로 구속된 철근 콘크리트 기둥의 휨 거동에 관한 연구 (A Study on the Flexural Behavior of R.C Columns Confined by Lateral Ties)

  • 조세용;양근혁;이영호;정헌수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.601-604
    • /
    • 1999
  • The objective of this study is to investigate the flexural behavior of reinforced concrete columns confined by lateral ties. This test was carried on the twelve reinforced concrete columns, 200$\times$200$\times$800mm size. objected to flexure and constant axial loads. The main variables are concrete strength, the configuration of lateral ties and the amount of lateral ties. Test results indicated that steel configuration plays an important role in column behavior, and a proper configuration of lateral ties can be more ductile than the reduce of the space of lateral ties. By this experiment, the ductility of high-strength concrete columns designed on A.C.I Code is not adequate, and are concluded that the design of high-strength concrete column is executed by more lateral ties under high axial loads.

  • PDF

띠철근 배근형태에 따른 고강도 철근콘크리트 기둥의 거동에 관한 실험적 연구 (An Experimental Study on Behavior of High-Strength R.C Columns According to the Configuration of Ties)

  • 이영인;곽노현;이영호;은희창;정헌수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표논문집(II)
    • /
    • pp.565-570
    • /
    • 1998
  • An objective of this study is to experimentally investigate the strength and ductility of reinforced concrete columns under uniaxial load and several test variables. To do this, we have conducted tests on twelve 20$\times$20$\times$60cm specimens with 8 and 12 longitudinal steel bars subjected to monotonic uniaxial compression. The main variables considered in this test are the configuration of ties, the strength of concrete, The results indicate that the strength and the ductility of reinforced concrete columns have been influenced on the configuration of ties, the strength of concrete.

  • PDF

고강도 콘크리트 기둥에서 띠철근의 구속효과에 관한 실험적 연구 (An experimental Study on Effect of Lateral Ties of High-Strength Concrete Columns)

  • 정봉호;곽노현;이영호;은희창;정헌수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.501-506
    • /
    • 1999
  • The purpose of this study is to experimentally investigate the strength and ductility of reinforced high strength concrete columns under uniaxial load and several test variables. To do this, we have conducted tests on thirteen 20$\times$20$\times$60cm specimens with 8 and 12 longitudinal steel bars subjected to monotonic uniaxial compression. The main variables considered in this test are the configuration of ties, the space the ties, the diameter of ties and yield strength of ties. The results indicate that the strength and the ductility of reinforced high strength concrete columns have been influenced on these variables except yield strength of ties. Judging from test results, real stress of ties at peak concrete stress is suitable variable than yield strength of ties for estimation of the strength gain factor(Ks).

  • PDF

Strength enhancement in confined concrete with consideration of flexural flexibilities of ties

  • Teerawong, J.;Lukkunaprasit, P.;Senjuntichai, T.
    • Structural Engineering and Mechanics
    • /
    • 제18권2호
    • /
    • pp.151-166
    • /
    • 2004
  • The interaction between concrete core expansion and deformation of perimeter ties has been known to have a significant effect on the effective confinement of rectangular reinforced concrete (RC) tied columns. This interaction produces passive confining pressure to the concrete core. Most existing models for determining the response of RC tied columns do not directly account for the influence of flexural stiffness of the ties and the variation of confining stress along the column height. This study presents a procedure for determining the confined compressive strength of RC square columns confined by rectilinear ties with various tie configurations considering directly the influence of flexural flexibility of the ties and the variation of confining stress along the vertical direction. The concept of area compatibility is employed to ensure compatibility of the concrete core and steel hoop in a global sense. The proposed procedure yields satisfactory predictions of confined strengths compared with experimental results, and the influence of tie flexibility, tie configuration and degree of confinement can be well captured.

국내 배전계통의 6분할 3연계 최적분할 모델 구성방안 (Optimal Division Model Configuration Plan According to 6 Divisions 3 Ties in Korea Distribution System)

  • 이대동;손성환;하복남;현동석;김영달
    • 전기학회논문지P
    • /
    • 제59권4호
    • /
    • pp.428-433
    • /
    • 2010
  • According as economy grows, demand for power increases and satisfaction of customer about electricity quality is rising. There is in trend that investment expense by continuously increased supply of electric power equipment is on the increase continuously, but management efficiency improvement through curtailment of supply of electric power equipment investment expense through efficient operation is required rather than to increase investment. In this study, reconsidered about 6 divisions 3 ties that is distribution line basis configuration of Daejeon Geumsan area and analyzed division and tie present condition of truthful distribution System. Examined problem analyzing average division number, tie number and tie switch number, searched about most suitable division that consider load. Hereafter, I wish to take advantage of analysis result in most suitable division and tie of truthful distribution system for power failure section reduction and investment expense curtailment.

편심 압축력을 받는 고강도 콘크리트 기둥의 거동에 미치는 띠철근 및 콘크리트 강도의 영향 (Influence of Concrete Strength and Lateral Ties on Behavior of High-Strength Concrete Columns Subjected to Eccentric Compressive Load)

  • 이영호;정헌수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제11권3호
    • /
    • pp.95-104
    • /
    • 2007
  • 편심 하중을 받는 철근 콘크리트 기둥에서 띠철근과 콘크리트 강도의 영향을 파악하기 위하여 콘크리트 압축강도, 띠철근 배근간격 및 형상, 편심비를 주요 변수로 하여 단면 $200mm{\times}200mm$의 시험체 24개를 실험하였다. 이러한 연구를 통하여 콘크리트 기둥은 편심거리비, 띠철근 배근간격, 띠철근 배근형태 등에 관계없이 콘크리트 강도가 증가할수록 취성적으로 거동하였고, 편심거리비가 증가할수록 띠철근 배근에 의한 연성 증가 효과는 감소함을 알 수 있었다. 띠철근 배근간격이 100mm에서 30mm로 줄어들 경우, 최대 내력은 10~20% 증가하였으며, 최대 내력 이후에도 보다 연성적으로 거동하였다. 그러므로 고강도 콘크리트 기둥에서 적당한 연성과 강도를 확보하기 위해서는 일반강도 콘크리트에 비하여 더 많은 띠철근 체적비와 밀실한 띠철근 배근이 필요하였으며, 띠철근 배근 간격만을 제한하는 현재의 대한건축학회 내진 기준은 고강도 콘크리트 사용 시 띠철근의 배근 효과와 부재 연성 확보 측면에서 불안전하였으며, 띠철근을 콘크리트 강도와 연계하는 새로운 내진 기준이 필요한 것으로 나타났다.

고강도 띠철근으로 구속된 고강도 콘크리트 기둥의 연성 (Ductility of High-Strength Concrete Columns with High-Strength Lateral Ties)

  • 문호권;이영호;양근혁;정헌수
    • 콘크리트학회논문집
    • /
    • 제13권3호
    • /
    • pp.261-267
    • /
    • 2001
  • 본 연구는 고축력을 받는 고강도 콘크리트 기둥부재의 연성을 확보하기 위한 띠철근 양 산정시 띠철근 강도가 연성에 미치는 영향이 현저하게 나타나기 시작하는 축력비 및 연성과 주근의 관계를 파악하기 위한 실험적 연구이다 본 연구의 목적을 이루기 위해 띠철근 항복강도, 축력비, 주근 양 및 배치형태 등을 주요 변수로 하여 총 12개의 시험체를 제작하였다. 시험체의 크기는 20$\times$20$\times$80 cm이며 실험구간은 중앙부 40 cm 이다. 실험결과 띠철근의 항복강도가 연성에 영향을 현저히 미치기 시작하는 축력비는 0.4 $f_{ck}$ $A_{g}$이었으며 현 ACI318-99 내진기준에 따라 띠철근 양을 산정할 때 저축력하에서 고강도 띠철근을 사용할 경우 띠철근 간격이 크고 띠철근 강도의 영향이 미비하여 부재는 취성적인 거동을 보일 위험이 있다. 고축력하에서 고강도 띠철근은 주근의 좌굴억제에도 상당히 효율적이었다. 특히 0.4 $f_{ck}$ $A_{g}$이상의 고축력하에서 고강도 띠철근이 응력을 충분히 발휘하기 위해서는 띠철근 체적비 및 배근형태, 주근의 배치형태, 축력비 등을 함께 고려하여야 할 것이라고 사료된다.다.

Compressive behavior of steel stirrups-confined square Engineered Cementitious Composite (ECC) columns

  • Zheng, Pan-deng;Guo, Zi-xiong;Hou, Wei;Lin, Guan
    • Advances in concrete construction
    • /
    • 제11권3호
    • /
    • pp.193-206
    • /
    • 2021
  • Extensive research has been conducted on the basic mechanical property and structural applications of engineered cementitious composites (ECC). Despite the high tensile ductility and high toughness of ECC, transverse steel reinforcement is still necessary to confine ECC for high performance. However, limited research has examined performance of ECC confined with practical amount of transverse reinforcement. This paper presents the results of axial compression tests on 14 square ECC columns and 4 conventional concrete columns (used as control specimens) with transverse reinforcement. The test variables were spacing, configuration (square ties or square and diamond shape ties), and yield strength of stirrups. The test showed that ECC columns confined with steel stirrup had good compressive ductility, and the stirrup spacing had the greatest effect on the compressive performance. The self-confinement effect of ECC results in a more uniform but slower expansion of the whole column compared with CC ones. The test results are then compared against the predictions from a number of existing models for conventional confined concrete. It is indicated that these models fail to predict the axial strains at peak axial stress and the trend of the stress-strain curve of steel stirrups-confined ECC with sufficient accuracy. Several new equations are then proposed for the compressive properties of steel-confined ECC based on test results and potential approaches for future studies are proposed.

Axial behavior of the steel reinforced lightweight aggregate concrete (SRLAC) short columns

  • Mostafa, Mostafa M.A.;Wu, Tao;Liu, Xi;Fu, Bo
    • Steel and Composite Structures
    • /
    • 제39권5호
    • /
    • pp.583-598
    • /
    • 2021
  • The composite steel reinforced concrete (SRC) columns have been widely used in Structural Engineering due to their good performances. Many studies have been done on the SRC columns' performances, but they focused on the ordinary types with conventional configurations and materials. In this study, nine new types of steel reinforced lightweight aggregate concrete (SRLAC) short columns with cross-shaped (+shaped and X-shaped) steel section were tested under monotonically axial compressive load; the studied parameters included steel section ratio, steel section configuration, ties spacing, lightweight aggregate concrete (LWAC) strength, and longitudinal bars ratio. From the results, it could be found that the specimens with larger ties ratio, concrete strength, longitudinal bars ratio, and steel section ratio achieved great strength and stiffness due to the excellent interaction between the concrete and steel. The well-confined concrete core could strengthen the steel section. The ductility and toughness of the specimens were influenced by the LWAC strength, steel section ratio, and longitudinal bars ratio; in addition, larger ties ratio with smaller LWAC strength led to better ductility and toughness. The load transfer between concrete and steel section largely depends on the LWAC strength, and the ultimate strength of the new types of SRLAC short columns could be approximately predicted, referring to the codes' formulas of ordinary types of steel reinforced concrete (SRC) columns. Among the used codes, the BS-5400-05 led to the most conservative results.