• Title/Summary/Keyword: cone-beam CT

Search Result 237, Processing Time 0.022 seconds

Comparison of effective dose for imaging of mandible between multi-detector CT and cone-beam CT

  • Jeong, Dae-Kyo;Lee, Sang-Chul;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.42 no.2
    • /
    • pp.65-70
    • /
    • 2012
  • Purpose : The aim of this study was to compare the effective dose for imaging of mandible between multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). An MDCT with low dose technique was also compared with them. Materials and Methods : Thermoluminescent dosimeter (TLD) chips were placed at 25 organ sites of an anthropomorphic phantom. The mandible of the phantom was exposed using 2 different types of MDCT units (Somatom Sensation 10 for standard-dose MDCT, Somatom Emotion 6 for low-dose MDCT) and 3 different CBCT units (AZ3000CT, Implagraphy, and Kavo 3D eXaM). The radiation absorbed dose was measured and the effective dose was calculated according to the ICRP 2007 report. Results : The effective dose was the highest for Somatom Sensation 10 (425.84 ${\mu}Sv$), followed by AZ3000CT (332.4 ${\mu}Sv$), Somatom Emotion 6 (199.38 ${\mu}Sv$), and 3D eXaM (111.6 ${\mu}Sv$); it was the lowest for Implagraphy (83.09 ${\mu}Sv$). The CBCT showed significant variation in dose level with different device. Conclusion : The effective doses of MDCTs were not significantly different from those of CBCTs for imaging of mandible. The effective dose of MDCT could be markedly decreased by using the low-dose technique.

A study on sagittal root position of maxillary anterior teeth in Korean (한국인에서 상악 전치의 시상 치근 위치에 대한 연구)

  • Kong, Hyun-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.88-94
    • /
    • 2020
  • Purpose: The purpose of this study was to analyze the sagittal root position of maxillary anterior teeth and report the frequency of each classification in Korean for immediate implant placement. Materials and Methods: A retrospective review of cone-beam computed tomography (cone-beam CT) images was conducted on 120 patients (60 male and 60 female) who fulfilled the inclusion criteria. After reorientation of the axis, cone-beam CT images were evaluated and the relationship of the sagittal root position (SRP) of the maxillary anterior teeth to its associated osseous housing was recorded. Class I, II, and III were classified respectively when the root was positioned on the labial, central, and palatal aspect of the alveolar bone. Class IV was the position that at least two thirds of the root is engaging both the labial and palatal cortical plates. Then, the angulation of the root axis and the alveolar bone axis was measured. Descriptive statistics and Kruskal-Wallis test were used to compare the angulation according to the root position and SRP class. Results: The frequency distribution of sagittal root position of maxillary anterior teeth indicated that 81.1%, 10.3%, 1.9%, and 6.7% were classified as Class I, II, III, and IV, respectively. The sagittal angulation at approximately 77.5% of central incisor, lateral incisor, and canine was < 20 degrees, but the angle at more than 42.7% of canine was ≥ 20 degrees. Within the class, the angulation was statistically significantly greater in Class I (16.19) compared to Class II (8.72) and Class III (9.93), and smaller in Class IV (3.79). Conclusion: Within the limitation of this study, a majority of the maxillary anterior roots were positioned close to the buccal cortical plate. However, some roots have very thin alveolar bone and sagittal angulation larger than 30 degrees. Therefore, cone-beam CT analyses of the sagittal root position and the sagittal angulation are recommended for the selection of the appropriate dental implant treatment approach.

Patient radiation dose and protection from cone-beam computed tomography

  • Li, Gang
    • Imaging Science in Dentistry
    • /
    • v.43 no.2
    • /
    • pp.63-69
    • /
    • 2013
  • After over one decade development, cone beam computed tomography (CBCT) has been widely accepted for clinical application in almost every field of dentistry. Meanwhile, the radiation dose of CBCT to patient has also caused broad concern. According to the literature, the effective radiation doses of CBCTs in nowadays market fall into a considerably wide range that is from $19{\mu}Sv$ to $1073{\mu}Sv$ and closely related to the imaging detector, field of view, and voxel sizes used for scanning. To deeply understand the potential risk from CBCT, this report also reviewed the effective doses from literatures on intra-oral radiograph, panoramic radiograph, lateral and posteroanterior cephalometric radiograph, multi-slice CT, and so on. The protection effect of thyroid collar and leaded glasses were also reviewed.

An alternative approach to extruding a vertically impacted lower third molar using an orthodontic miniscrew: A case report with cone-beam CT follow-up

  • Cortes, Arthur Rodriguez Gonzalez;No-Cortes, Juliana;Cavalcanti, Marcelo Gusmao Paraiso;Arita, Emiko Saito
    • Imaging Science in Dentistry
    • /
    • v.44 no.2
    • /
    • pp.171-175
    • /
    • 2014
  • One of the most common oral surgical procedures is the extraction of the lower third molar (LTM). Postoperative complications such as paresthesia due to inferior alveolar nerve (IAN) injury are commonly observed in cases of horizontal and vertical impaction. The present report discusses a case of a vertically impacted LTM associated with a dentigerous cyst. An intimate contact between the LTM roots and the mandibular canal was observed on a panoramic radiograph and confirmed with cone-beam computed tomographic (CBCT) cross-sectional cuts. An orthodontic miniscrew was then used to extrude the LTM prior to its surgical removal in order to avoid the risk of inferior alveolar nerve injury. CBCT imaging follow-up confirmed the success of the LTM orthodontic extrusion.

Cone-beam computed tomography: Time to move from ALARA to ALADA

  • Jaju, Prashant P.;Jaju, Sushma P.
    • Imaging Science in Dentistry
    • /
    • v.45 no.4
    • /
    • pp.263-265
    • /
    • 2015
  • Cone-beam computed tomography (CBCT) is routinely recommended for dental diagnosis and treatment planning. CBCT exposes patients to less radiation than does conventional CT. Still, lack of proper education among dentists and specialists is resulting in improper referral for CBCT. In addition, aiming to generate high-quality images, operators may increase the radiation dose, which can expose the patient to unnecessary risk. This letter advocates appropriate radiation dosing during CBCT to the benefit of both patients and dentists, and supports moving from the concept of "as low as reasonably achievable" (ALARA) to "as low as diagnostically acceptable" (ALADA).

New evolution of cone-beam computed tomography in dentistry: Combining digital technologies

  • Jain, Supreet;Choudhary, Kartik;Nagi, Ravleen;Shukla, Stuti;Kaur, Navneet;Grover, Deepak
    • Imaging Science in Dentistry
    • /
    • v.49 no.3
    • /
    • pp.179-190
    • /
    • 2019
  • Panoramic radiographs and computed tomography (CT) play a paramount role in the accurate diagnosis, treatment planning, and prognostic evaluation of various complex dental pathologies. The advent of cone-beam computed tomography (CBCT) has revolutionized the practice of dentistry, and this technique is now considered the gold standard for imaging the oral and maxillofacial area due to its numerous advantages, including reductions in exposure time, radiation dose, and cost in comparison to other imaging modalities. This review highlights the broad use of CBCT in the dentomaxillofacial region, and also focuses on future software advancements that can further optimize CBCT imaging.

Does cone-beam CT alter treatment plans? Comparison of preoperative implant planning using panoramic versus cone-beam CT images

  • Guerrero, Maria Eugenia;Noriega, Jorge;Castro, Carmen;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • v.44 no.2
    • /
    • pp.121-128
    • /
    • 2014
  • Purpose: The present study was performed to compare the planning of implant placement based on panoramic radiography (PAN) and cone-beam computed tomography (CBCT) images, and to study the impact of the image dataset on the treatment planning. Materials and Methods: One hundred five partially edentulous patients (77 males, 28 females, mean age: 46 years, range: 26-67 years) seeking oral implant rehabilitation were referred for presurgical imaging. Imaging consisted of PAN and CBCT imaging. Four observers planned implant treatment based on the two-dimensional (2D) image data-sets and at least one month later on the three-dimensional (3D) image dataset. Apart from presurgical diagnostic and dimensional measurement tasks, the observers needed to indicate the surgical confidence levels and assess the image quality in relation to the presurgical needs. Results: All observers confirmed that both imaging modalities (PAN and CBCT) gave similar values when planning implant diameter. Also, the results showed no differences between both imaging modalities for the length of implants with an anterior location. However, significant differences were found in the length of implants with a posterior location. For implant dimensions, longer lengths of the implants were planned with PAN, as confirmed by two observers. CBCT provided images with improved scores for subjective image quality and surgical confidence levels. Conclusion: Within the limitations of this study, there was a trend toward PAN-based preoperative planning of implant placement leading towards the use of longer implants within the posterior jaw bone.

Development of a Micro-CT System for Small Animal Imaging (소 동물 촬영을 위한 Micro-CT의 개발)

  • Sang Chul Lee;Ho Kyung Kim;In Kon Chun;Myung Hye Cho;Min Hyoung Cho;Soo Yeol Lee
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.97-102
    • /
    • 2004
  • We developed an x-ray cone-beam micro computed tomography (micro-CT) system for small-animal imaging. The micro-CT system consists of a 2-D flat-panel x-ray detector with a field-of-view (FOV) of 120${\times}$120 mm2, a micro-focus x-ray source, a scan controller and a parallel image reconstruction system. Imaging performances of the micro-CT system have been evaluated in terms of contrast and spatial resolution. The minimum resolvable contrast has been found to be less than 36 CT numbers at the dose of 95 mGy and the spatial resolution about 14 lp/mm. As small animal imaging results, we present high resolution 3-D images of rat organs including a femur, a heart and vessels. We expected that the developed micro-CT system can be greatly used in biomedical studies using small animals.

Cone-beam CT superimposition and visualization using open-source softwares (오픈-소스 소프트웨어를 이용한 콘빔 전산화단층영상의 중첩 및 시각화)

  • Jeon, Woo-Ram;Lim, Sung-Hoon
    • The Journal of the Korean dental association
    • /
    • v.56 no.10
    • /
    • pp.538-547
    • /
    • 2018
  • ITK-SNAP (http://www.itksnap.org) and 3D Slicer (CMFreg extension module; www.slicer.org) are open-source softwares which can be used for superimposition of cone-beam CT images. For superimposition, segmentation of bone is done with ITK-SNAP, and then voxel based superimposition of CBCT images can be performed using 3D Slicer. 3D Slicer has various visualization modules which are not provided in common commercial programs. 'Models' module is used to visualize two overlapping three-dimensional images, and this allows various visualizations by changing view mode and color of the model. In addition, differences between two CBCT images can be represented in a color map using 'ShapePopulationViewer' module. This report introduces how to superimpose and visualize CBCT images using ITK-SNAP and 3D Slicer, and the usefulness and limitations of both softwares will be discussed in comparison with commercial softwares.

  • PDF