• Title/Summary/Keyword: cone-beam CT

Search Result 235, Processing Time 0.022 seconds

Radiographic Evaluation of Stiffness of Articular Eminence in the Temporomandibular Joint(TMJ) of Korean Using Dental cone-beam CT (한국인의 측두하악관절에서 Dental cone-beam CT를 이용한 관절융기의 경사도에 대한 방사선학적 평가)

  • Oh, Sang-Chun;Han, Ji-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.2
    • /
    • pp.163-173
    • /
    • 2013
  • When the mandible performs opening movement, the condyle-disk complex conducts sliding movement along the articular eminence. Thus, anatomic configuration of articular eminence is very important to normal movement of TMJ. The purpose of this study was to measure the posterior slope of the articular eminence and evaluate the effect of a pathologic bone change in the condylar head on the stiffness of articular eminence, and compare the differences of the articular eminence slope by gender and age using dental cone-beam CT. As using i-CAT Cone-Beam Computed Tomography, the CT images of 204 TMJs of 102 patients(43 men and 59 women, mean age: 37.7 years) who were diagnosed at Wonkwang University Sanbon Dental Hospital were evaluated. All images were converted into a TMJ analysis mode to observe the continuous sagittal section images and coronal section images of the joints. To observe and assess bone changes in the condyle, three dentists measured the stiffness of the articular eminence on the same images, and when two of the three dentists agreed on their reading, these results were adopted and recorded. The articular eminence slope, considering the condylar anatomic configuration, was measured in three regions, namely, lateral part, central part, and medial part of the condyle. In the cases of a normal condyle(NCBC) and a condyle(CBC) with bone change, the articular eminence slopes were $57.0^{\circ}$(NCBC) and $51.8^{\circ}$(CBC) at the medial part, $57.9^{\circ}$(NCBC) and $52.4^{\circ}$(CBC) at the central part, and $55.1^{\circ}$(NCBC) and $49.5^{\circ}$(CBC) at the lateral part of the condyle. And the articular eminence slope of the condyle with bone change demonstrated less steepness than that of normal condyle (p<0.05). The articular eminence slope showed mediolaterally that it was the steepest at the central, followed by at the medial, and at the lateral (p<0.05). There were no significant differences by the gender and the age (p.0.05).

The Broad-beam CT Image Reconstruction from Simulator Images (모의치료(Simulation) 영상을 이용한 Broad-beam CT 영상 구현)

  • Yi, Byong-Yong
    • Radiation Oncology Journal
    • /
    • v.16 no.1
    • /
    • pp.81-86
    • /
    • 1998
  • Purpose : To generate the axial, coronal and sagittal images from conventional simulation images, as a preliminary study of broad-beam simulator CT. Methods and Materials : Volumetric filtered back-projection was performed using 90 sheets of films from conventional simulator for every $4^{\circ}$ gantry angle. Two mAs exposure condition for 120kvp beam qualify at SFD 140cm was given to each film. Outside the silhouette portion was removed and scatter component was deconvolved before back-projection. Results : The axial, the sagittal and the coronal images with same spatial resolutions over all direction could be obtained. But image quality was very poor. Conclusion : CT images could be obtained using broad-beam. Scatter deconvolution technique was effective for this reconstruction. The fact that same spatial resolutions over all direction tells us the possibility of application of this technique to DRR or Simulator-CT. But the quality of image should be improved for clinical application practically.

  • PDF

Morphological difference of symphysis according to various skeletal types using cone-beam computed tomography (안면골격 유형에 따른 하악 전치 치조골의 형태 차이: Cone-beam CT를 이용한 정량적 평가)

  • Kwon, Hyun-Jin;Chun, Youn-Sic;Kim, Min-Ji
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.3
    • /
    • pp.215-222
    • /
    • 2014
  • Purpose: The aim of this study was to investigate differences between the morphology of the mandibular symphysis and four facial skeletal types. Materials and Methods: 40 cone-beam computed tomographies were selected and classified in to 4 groups according to their vertical and anterior-posterior skeletal patterns. The bone volume ($mm^3$) of the symphysis, the cross sectional area corresponding to the 4 mandibular incisors' axis: the cross sectional area of total bone ($mm^2$), the area of the cancellous bone ($mm^2$) and the thickness (mm) of labial and lingual alveolar bone at 2 mm, 3 mm under the cemento-enamel junction (CEJ) were measured. General linear model (GLM), Kruskal-Wallis test and Tukey honestly significant difference (HSD) test were subsequently used for statistical analysis. Results: The lingual cortical bone thickness of the lateral incisors at 2, 3 mm under CEJ was greater in the Class I low angle group than the other 3 groups (P < 0.05). There were no statistically significant differences in the volume of the mandibular incisor bony support, cross-sectional area of total bone and cancellous bone at the mandibular incisor' axis. Conclusion: Patients in Class I, low angle group have a thicker lingual mandibular symphysis than Class I, high angle patients.

A method for mandibular dental arch superimposition using 3D cone beam CT and orthodontic 3D digital model

  • Park, Tae-Joon;Lee, Sang-Hyun;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.42 no.4
    • /
    • pp.169-181
    • /
    • 2012
  • Objective: The purpose of this study was to develop superimposition method on the lower arch using 3-dimensional (3D) cone beam computed tomography (CBCT) images and orthodontic 3D digital modeling. Methods: Integrated 3D CBCT images were acquired by substituting the dental portion of 3D CBCT images with precise dental images of an orthodontic 3D digital model. Images were acquired before and after treatment. For the superimposition, 2 superimposition methods were designed. Surface superimposition was based on the basal bone structure of the mandible by surface-to-surface matching (best-fit method). Plane superimposition was based on anatomical structures (mental and lingual foramen). For the evaluation, 10 landmarks including teeth and anatomic structures were assigned, and 30 times of superimpositions and measurements were performed to determine the more reproducible and reliable method. Results: All landmarks demonstrated that the surface superimposition method produced relatively more consistent coordinate values. The mean distances of measured landmarks values from the means were statistically significantly lower with the surface superimpositions method. Conclusions: Between the 2 superimposition methods designed for the evaluation of 3D changes in the lower arch, surface superimposition was the simpler, more reproducible, reliable method.

Consideration of computer-guided implant surgery (임플란트 가이드 수술시 고려사항)

  • Kim, Hyun Dong
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.28 no.1
    • /
    • pp.4-17
    • /
    • 2019
  • Nowadays, Cone-Beam CT is widely supplied in dental clinics, the distribution rate in south korea is highly ranked worldwidely. Recently, The number of Cone-Beam CTs reached 10 thousands according to national healthcare system report. Also, dental manufacturers released many kinds of In-house 3D digital printers, the distribution rate of which rises rapidly in dental clinics. Accordingly, using Cone-Beam CT data and Intraloral scan data, the application of implant guide surgery is widespread in a unit of private clinic. Through the previous articles, the latest methods of computer-guided implant surgery are reviewed, and also the considerations for precise and reliable guide surgery are summarized.

Temporomandibular Joint Ankylosis Caused by Osteoarthritis: A Case Report Based on Cone Beam Computed Tomography Images

  • Jih, Myeong Kwan;Kim, Jin Soo;Park, Hyun-Jeong
    • Journal of Oral Medicine and Pain
    • /
    • v.47 no.3
    • /
    • pp.156-160
    • /
    • 2022
  • Temporomandibular joint (TMJ) ankylosis is a condition in which condylar movement is restricted because of fibrous or bony union between the mandibular condyle and temporal bone. TMJ ankylosis is most often caused by trauma, followed by systemic or local infection, and secondary to unknown causes. Diagnostic imaging plays a vital role in diagnosing TMJ ankylosis and establishing a treatment plan. Computed tomography (CT) or cone beam computed tomography (CBCT) is currently the imaging technique of choice to accurately demonstrate preoperative ankylosing masses and other surgically important findings, such as the shape of the mandibular condyle and the pathological changes in the joint. The osseous changes in the mandibular condyle are easily identified in the coronal and sagittal sections of CT or CBCT images. This report describes the case of a middle-aged woman who developed TMJ ankylosis of the left TMJ while undergoing repeated treatment for TMJ disease. We report the findings observed on radiographic and CBCT images through continuous observation.

Trifid mandibular canal in Cone-Beam CT : A case report (CBCT에서 관찰되는 trifid mandibular canal)

  • Han, Won-Jeong
    • The Journal of the Korean dental association
    • /
    • v.56 no.2
    • /
    • pp.113-119
    • /
    • 2018
  • Trifid mandibular canal (TMC) is one of the anatomical variation of mandibular canal with clinical importance. An extra mandibular canal may explain inadequate anesthesis and be damaged causing paresthesia or bleeding during mandibular surgery. CBCT with high-level spatial resolution is an useful tool for the detection of mandibular canal and its variation. The aim of this report is to present a case of trifid mandibular canal with CBCT images and to give information on this anatomical variation of mandibular canal.

  • PDF

Enhancement of the Deformable Image Registration Accuracy Using Image Modification of MV CBCT (Megavoltage Cone-beam CT 영상의 변환을 이용한 변환 영상 정합의 정확도 향상)

  • Kim, Min-Joo;Chang, Ji-Na;Park, So-Hyun;Kim, Tae-Ho;Kang, Young-Nam;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.28-34
    • /
    • 2011
  • To perform the Adaptive Radiation Therapy (ART), a high degree of deformable registration accuracy is essential. The purpose of this study is to identify whether the change of MV CBCT intensity can improve registration accuracy using predefined modification level and filtering process. To obtain modification level, the cheese phantom images was acquired from both kilovoltage CT (kV CT), megavoltage cone-beam CT (MV CBCT). From the cheese phantom images, the modification level of MV CBCT was defined from the relationship between Hounsfield Units (HUs) of kV CT and MV CBCT images. 'Gaussian smoothing filter' was added to reduce the noise of the MV CBCT images. The intensity of MV CBCT image was changed to the intensity of the kV CT image to make the two images have the same intensity range as if they were obtained from the same modality. The demon deformable registration which was efficient and easy to perform the deformable registration was applied. The deformable lung phantom which was intentionally created in the laboratory to imitate the changes of the breathing period was acquired from kV CT and MV CBCT. And then the deformable lung phantom images were applied to the proposed method. As a result of deformable image registration, the similarity of the correlation coefficient was used for a quantitative evaluation of the result was increased by 6.07% in the cheese phantom, and 18% in the deformable lung phantom. For the additional evaluation of the registration of the deformable lung phantom, the centric coordinates of the mark which was inserted into the inner part of the phantom were measured to calculate the vector difference. The vector differences from the result were 2.23, 1.39 mm with/without modification of intensity of MV CBCT images, respectively. In summary, our method has quantitatively improved the accuracy of deformable registration and could be a useful solution to improve the image registration accuracy. A further study was also suggested in this paper.

Radiologic study of the healing process of the extracted socket of beagle dogs using cone beam CT (Cone beam CT를 이용한 비글견 발치창 치유과정에 대한 방사선학적 연구)

  • Choi, Dong-Hoon;Lee, Wan;Kim, De-Sok;Lee, Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.39 no.1
    • /
    • pp.19-25
    • /
    • 2009
  • Purpose: To longitudinally observe the healing process of extracted socket and the alterations of the residual ridge in healthy adult dogs using cone beam CT (CBCT). Materials and Methods: The mandibular premolars of two beagle dogs were removed and the extraction sites were covered with the gingival tissue. CBCTs (3D X-ray CT scanner, Alphard vega, Asahi Co.) were taken at baseline and at 1 week interval for 12 weeks. Radiographic density of extracted wounds was measured on normalized images with a custom-made image analysis program. The amount of alveolar crestal resorption after the teeth extraction was measured with a reformatted three-dimensional image using CBCT. Bony healing pattern of extracted wound of each group was also longitudinally observed and analyzed. Results: Dimensional changes occurred during the first 6 weeks following the extraction of dogs' mandibular premolars. The reduction of the height of residual ridge was more pronounced at the buccal than at the lingual aspect of the extraction socket. Radiographic density of extracted wounds increased by week 4, but the change in density stabilized after week 6. New bone formation was observed at the floor and the peripheral side of extracted socket from week 1. The entrance of extracted socket was sealed by a hard-tissue bridge at week 5. Conclusion: The healing process of extracted wound involved a series of events including new bone formation and residual ridge resorption.

  • PDF

Comparison of micro-computerized tomography and cone-beam computerized tomography in the detection of accessory canals in primary molars

  • Acar, Buket;Kamburoglu, Kivanc;Tatar, Ilkan;Arikan, Volkan;Celik, Hakan Hamdi;Yuksel, Selcen;Ozen, Tuncer
    • Imaging Science in Dentistry
    • /
    • v.45 no.4
    • /
    • pp.205-211
    • /
    • 2015
  • Purpose: This study was performed to compare the accuracy of micro-computed tomography (CT) and cone-beam computed tomography (CBCT) in detecting accessory canals in primary molars. Materials and Methods: Forty-one extracted human primary first and second molars were embedded in wax blocks and scanned using micro-CT and CBCT. After the images were taken, the samples were processed using a clearing technique and examined under a stereomicroscope in order to establish the gold standard for this study. The specimens were classified into three groups: maxillary molars, mandibular molars with three canals, and mandibular molars with four canals. Differences between the gold standard and the observations made using the imaging methods were calculated using Spearman's rho correlation coefficient test. Results: The presence of accessory canals in micro-CT images of maxillary and mandibular root canals showed a statistically significant correlation with the stereomicroscopic images used as a gold standard. No statistically significant correlation was found between the CBCT findings and the stereomicroscopic images. Conclusion: Although micro-CT is not suitable for clinical use, it provides more detailed information about minor anatomical structures. However, CBCT is convenient for clinical use but may not be capable of adequately analyzing the internal anatomy of primary teeth.