• Title/Summary/Keyword: cone collection

Search Result 21, Processing Time 0.023 seconds

Improvement of a High-volume Aerosol Particle Sampler for Collecting Submicron Particles through the Combined Use of a Cyclone with a Smoothened Inner Wall and a Circular Cone Attachment

  • Okuda, Tomoaki;Isobe, Ryoma
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.2
    • /
    • pp.131-137
    • /
    • 2017
  • A cyclone is an effective tool to facilitate the collection of aerosol particles without using filters, and in cell exposure studies is able to collect a sufficient amount of aerosol particles to evaluate their adverse health effect. In this study, we examined two different methods to improve the aerosol particle collection efficiency of a cyclone. The individual and combined effects of reducing the surface roughness of the inner wall of the cyclone and of using a circular cone attachment were tested. The collection efficiency of particles of diameter $0.2{\mu}m$ was improved by approximately 10% when using a cyclone with a smoothened inner wall (average roughness $Ra=0.08{\mu}m$) compared with the original cyclone ($Ra=5.1{\mu}m$). A circular cone attachment placed between the bottom section of the cyclone and the top section of a collection bottle, resulted in improved collection of smaller particles without the attachment. The 50% cutoff diameter of the modified cyclone (combined use of smoothened inner wall and attachment) was $0.23{\mu}m$ compared to $0.28{\mu}m$ in the original model. The combined use of these two techniques resulted in improved collection efficiency of aerosol particles.

A Numerical Study on Performance Improvement of Canopy Hood in Melting Process (용해공정의 캐노피 후드 성능 개선에 관한 수치 해석적 연구)

  • Jung, Yu-Jin;Shon, Byung-Hyun;Lee, Sang-Man;Jung, Jong-Hyeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.3
    • /
    • pp.1519-1526
    • /
    • 2013
  • This study reviewed the capturing performance of a canopy hood used in some melting processes of a casting manufacturing factory through a site survey. In addition, this study compared and evaluated the flow field and pressure field for the plans to enhance the hazardous air pollutants collection capacity by using CFD model. The case-2(flange attached + double hood) can be improved in terms of collection performance, but is expected to increase in hood static pressure by about 70% more than the existing structure, so it was shown that its site applicability is not good. It is judged that the shape of case-3(flange attached + double cone attached) is most suitable to improve the suction efficiency. This is because a double cone is installed at the center of the opening to concentrate the flow rate on the edge of the hood and control the hume rising to the center of the hood without a static pressure rise via the slope of the cone.

Variation of Seed Viability among Cone Harvest Times at Two Clonal Seed Orchards of Chamaecyparis obtusa

  • Da-Eun, Gu;Ji-Hee, Jeong;Ye-Ji, Kim;Kyu-Suk, Kang
    • Journal of Forest and Environmental Science
    • /
    • v.38 no.4
    • /
    • pp.256-262
    • /
    • 2022
  • The timing of seed harvesting is an important decision in the management of seed orchards because it affects seed quality and yield. To investigate the effect of cone harvest time on seed quality and determine the optimal harvesting time, cones were regularly collected in seven times and germination tests were performed at each harvest time in two clonal seed orchards of Chamaecyparis obtusa. As cones developed, the percentage of seed germination increased before cone moisture content began to decrease significantly. The moisture contents of cones were highest at the first collection as 68.3% and 67.3% in Jeju and Gochang seed orchards respectively. At this time, germination speed was slowest, indicating poor seed vigour. The highest germination was found at the second stage in Jeju (36.5%) and at the seventh stage in Gochang (28.6%) seed orchard. The germination speed increased as cone moisture content decreased. Additionally, changes of seed vigour differed among the developmental stages in both seed orchards. Consequently, the optimal cone harvest time of C. obtusa seed orchards in Jeju was early September when high germination percentage was obtained. In Gochang seed orchards, late October was optimal cone harvest time when the germination speed was fast and the cone moisture content decreased.

Application of Cyclone to Removal of Hot Particulate in Hot Cell (Hot Cell 내의 고방사능 분진 제거를 위한 사이클론 적용 실험)

  • Kim Gye Nam;Lee Sung Yeol;Won Hui Jun;Jung Chong Hun;Oh Won Zin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.1
    • /
    • pp.67-75
    • /
    • 2005
  • The size and main ingredient of hot particulate generated during the nuclide experiment in hot cells of nuclear facilities were 0.5300 $\mu$m and UO$\_2$. A cyclone filter equipment which consists of a cyclone and Bag/HEPA filter was devised to remove hot particulate generated during the nuclide experiment in hot cells of nuclear facilities. The experimental conditions to maximize the collection efficiency of hot particulate were suggested through experiments done with the cyclone filter equipment. With the large size of simulated particulate, the collection efficiency of the particulate was high. When the size of simulated particulate was more than 5 $\mu$m, the collection efficiency of the particulate was more than $80\%$ and when the size of simulated particulate was less than 1.0 urn, the collection efficiency decreased by less than $70\%$. If the inflow velocity of simulated particulate was increased, the collection efficiency of the particulate was also increased. When the inflow velocity of simulated particulate was more than 12m/sec, the collection efficiency was higher than $70\%$, but after 17 m/sec inflow velocity, no change observed. The collection efficiency of the simulated particulate can be enhanced with the length of vortex finder inside the chamber. With the length of vortex finder, 7.2cm, the observed collection efficiency of the particulate was the maximum. Moreover, when the sub-cone was attached under the cyclone, the collection efficiency of cyclone increased $2\%$. It was found that effect by attachment of sub-cone was not serious.

  • PDF

Optimal Design of Vacuum Cleaner with a Multi Cyclone (멀티사이클론을 이용한 진공청소기의 최적설계에 관한 연구)

  • Ha, Gun-Ho;Kim, Eung-Dal;Yang, Byung-Sun;Ahn, Young-Chull
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.2
    • /
    • pp.126-131
    • /
    • 2011
  • Cyclone, a type of particle collector widely used in the field of ambient sampling and industrial particulate control, is the principal type of gas-solids separator that uses a centrifugal force. The goal of this study is to design and evaluate the cyclone that can be used for the household vacuum cleaners. A multi cyclone with a 1st cyclone and several 2nd cyclones is designed to improve dust collection efficiency. The dust collection efficiency and the suction power of 1st cyclone are evaluated. And the dust collection efficiency and the suction power of multi cyclone are evaluated according to various sizes of inlet and vortex finder. As a result, a cone shape porous filter has better dust collection efficiency than a cylinder shape porous filter. The dust collection efficiency of a multi cyclone is 3.5% greater than that of a single cyclone.

Cone Characteristics and Seed Quality among Harvest Times in the Clonal Seed Orchard of Larix kaempferi (낙엽송 클론 채종원에서 구과 채취시기에 따른 구과특성 및 종자품질)

  • Ye-Ji Kim;Da-Eun Gu;Gyehong Cho;Heeyoon Choi;Yeongkon Woo;Chae-Bin Lee;Sungryul Ryu;Hye-Joon Joo;Kyu-Suk Kang
    • Journal of Korean Society of Forest Science
    • /
    • v.112 no.3
    • /
    • pp.352-362
    • /
    • 2023
  • Harvest time is one of the most important determining factors of seed quality, especially for species that produce seeds over irregular and long-term periods, such as Larix kaempferi. A cone collection plan must be established to increase seed production efficiency and stable mass production. We investigated seed qualities such as seed efficiency, germination rate, and T50 (germination speed), with 7 or 8 cone collection times at a clonal seed orchard of L. kaempferi in Chungju between 2021 and 2022. A multivariate analysis was then performed for the collected data. In early August, decreases in the moisture contents and browning of cones were observed. These were followed by a decrease in germination rate, with a peak at the end of September, but no clear trend was observed. The later the cones were harvested, the better the seed vigor (T50). However, the seed yield and efficiency decreased owing to increases in seed scattering and the number of insect-damaged seeds. As a result, the optimal time of seed harvest for the seed orchard was in early August. To produce uniform seedlings, insect damage must be reduced through timely control and harvest cones in early September. This shows that the degree of browning and moisture content of cones can be used as indicators of the timing of cone collection in L. kaempferi seed orchards.

Numerical Study of Cyclone Dust Collector (싸이클론 집진기의 수치해석적 연구)

  • 전영남;엄태인
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.1
    • /
    • pp.43-53
    • /
    • 1996
  • Numerical simulation was performed for the 3-dimensional flow filed of gas and particle phase for cyclone dust collector. FVM(Finite Volume Method) was employed for gas phase. The flow was solved suing the k-.varepsilon. epsilon turbulence model. The particle exit at the bottom of the cone was treated as a solid wall in this model because the gas flow through the effective dust exit is usually insignificant. The major parameters considered in this study was vortex finder diameter, effective dust exit diameterm vortex finder length, inlet type for dimension performance. Particle trajectory calculations were made for three different, particle sizes of 1, 25 and 50 .mu.m. The results obtained from this study give some physical insight of dust particle collection mechanism together with the indication of the collection efficiency. The simulation results were in generally good agreement with empirical knowledge. The application of this kind of computer program looks promising as a potential tool for the design of cyclone and determination of optimum operating condition.

  • PDF

Development of Cyclone Conveying System for Transporting Chopped Round Bale Roughage and Separating Dust (흙먼지 분리기 용이한 원형베일 세절 조사료의 사이클론 이송장치 개발)

  • Ha, Yu-Shin;Kwon, Jin-Kyung;Park, Kyung-Kyoo
    • Journal of Biosystems Engineering
    • /
    • v.36 no.3
    • /
    • pp.204-210
    • /
    • 2011
  • This study developed the cyclone conveying system using roughage cutter for the round bale reported in the previous papers. Performance tests were conducted whether it can easily separate dust from roughage such as rice straws and it can transport roughages from cutter to TMR mixer. In addition, the airflow patterns in the cyclone conveying system were investigated using CFD code (FLUENT 6.2) for various velocities of dust collection fan. The cyclone conveying system was designed based on dried rice straws with a diameter of 1,340 mm, a cylinder length of 1,220 mm, a cone length of 850 mm and the current velocity of the dust collection fan was 15~20 m/s. It was found that transporting of roughage from cutter to TMR mixer and the separation of dust were satisfactory, and the dust removal rate of rice straws was around 31.9%. CFD analysis showed that, at the blowing fan velocity of 11.6 m/s, the airflow velocity inside the dust collector increased as velocity of the dust collection fan increased, but the airflow patterns inside the dust collector were all much the same.

Numerical Study on the Internal Flow in the Cyclone Vacuum Cleaner (사이클론 청소기 내부 유동에 관한 수치해석적 연구)

  • Lee, Chanhyun;Chang, Hyuksang
    • Clean Technology
    • /
    • v.20 no.3
    • /
    • pp.283-289
    • /
    • 2014
  • General household vacuum cleaners consist of dust collector, pre filter, motor and exhaust filter, and the filtered clean air is discharged to the atmosphere. By using the CFD methods, we estimated the internal flow in two types of commercial cyclone vacuum cleaners to evaluate the dust collection performance. From the analysis, it was known that the number of revolution had higher values in cyclone cone region. CFD analysis in a specific showed non-uniform velocity distribution at outlet, which results in the deterioration of particle collection performance. In order to improve flow condition, the installation of baffle was proposed and the values of velocity RMS were estimated.

Bibliometric analysis and diagnostic efficacy of cone-beam computed tomography studies published in Imaging Science in Dentistry from 2011 to 2022

  • Kelda Zanchi Younan;Gabriel Francisco Krueger;Roberto Zimmer ;Pedro Antonio Gonzalez Hernandez;Vania Regina Camargo Fontanella;Sergio Augusto Quevedo Miguens-Jr
    • Imaging Science in Dentistry
    • /
    • v.53 no.4
    • /
    • pp.335-344
    • /
    • 2023
  • Purpose: This bibliometric analysis aimed to provide a comprehensive overview of the characteristics, trends, and level of diagnostic efficacy of studies on cone-beam computed tomography (CBCT) published in Imaging Science in Dentistry (ISD) from 2011 to 2022. Materials and Methods: Publications related to CBCT identified in the electronic collection of ISD were selected according to eligibility criteria by 2 independent reviewers who collected data on the characteristics of the articles (year, authors, and country). The type and topic of studies were analyzed using VOSviewer v.1.6.18 (Centre for Science and Technology Studies, Leiden University, Leiden, Netherlands). The research articles were classified according to the hierarchical scale of diagnostic efficacy. Results: Of the 236 articles included, most were from South Korea and Brazil. Bong-Hae Cho and Yun-Hoa Jung were the most prolific authors on the topic of CBCT. The most frequently published types of studies were cross-sectional and laboratory-based. The most popular topics WERE related to the diagnosis of pathologies and/or alterations, as well as anatomical variations. On the diagnostic efficacy scale, most studies were rated level 1 (technical efficacy) or 2 (diagnostic accuracy efficacy). Conclusion: A steady increase was observed in publications related to CBCT, which are of both clinical and academic interest. The trends in these publications were analyzed, revealing that most are cross-sectional studies primarily exploring the capabilities of CBCT in diagnosing pathologies and/or changes in the oral and maxillofacial complex. These studies were typically classified as level 1 or 2 on the diagnostic efficacy scale.