• Title/Summary/Keyword: conductor structure analysis

Search Result 86, Processing Time 0.022 seconds

Electrical Fire Identification due to Conductor Structure Analysis of Electrical Wires (전선의 도체조직 분석에 의한 전기화재 감식)

  • Park, O-Cheol;Kim, Wang-Kon;Park, Nam-Kyu;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.615-618
    • /
    • 2003
  • To investigate the electrical fire identification due to conductor structure analysis of an electrical wire, we are studied by temperature heating test, over current test, short test and electric molten marks. And metal structure analysis of wire by short, we are found out increase in crystal grain with heating temperature. Structure of specimen at over current 300[%] occurred hardly structure formation and boundary of grain.

  • PDF

Study of the Method to Examine the Cause of Damage to a Flat-Type Vinyl Cord (VFF) According to the Type of Energy Source (에너지원의 종류에 따른 비닐평형코드(VFF)의 소손원인 판정기법에 관한 연구)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.83-88
    • /
    • 2011
  • This study presented the structure and characteristics of vinyl cords used for wiring electric equipment and appliances and analyzed the photographs of damaged flat-type vinyl cords (VFF, $1.25mm^2$) and the metallic cross-sectional structure of melted conductors. Normal VFFs were made by twisting several strands together and the surface of the conductor was red brown. In addition, from the analysis of the metallic structure of the conductor, it was found that its grains had been elongated. The surface of a VFF damaged by normal flame showed no sheen with carbonized insulation material fused on the conductor surface. In addition, from the analysis of the cross-sectional structure of the melted area, it was found that voids of a certain shape were formed on it but that the cord's own elongation structure could not be checked. The cross-sectional analysis of the melted conductor damaged by the external flame applied to a VFF to which electric current was being applied showed no elongation structure for each cord, and revealed that irregular voids and a columnar structure had grown. The surface of the VFF damaged by overcurrent was uniformly carbonized and the cross-sectional structure analysis of the melted conductor revealed that the dendritic structure had grown. The analysis of the characteristics of the VFF melted by short-circuit showed that even though some part of the surface was contaminated, it showed little sheen and that the area rebounded by melting was round in shape. In addition, the cross-sectional structure analysis using a metallurgical microscope showed the boundary surface and columnar structure and revealed an amorphous structure like normal copper at areas other than the melted conductor.

Overhead Rigid Conductor and Transition Structure for High-Speed (Over 250 km/h) I : Structural Design (250 km/h급 고속용 강체전차선 및 이행장치 I : 구조설계)

  • Kim, Bong-Suk;Won, Yong-Hee;Park, Seol-Hee;Bae, Sang-Joon;Jang, Kwang-Dong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.1
    • /
    • pp.7-13
    • /
    • 2016
  • With the increasing running speed of trains, new railway lines in metropolitan areas, and the rising demand for green transportations, the number of underground and tunnel sections are constantly becoming larger, and installations of overhead rigid conductor systems are becoming wider. However, domestic commercial products for overhead rigid conductors are limited to 120 km/h train speeds. In this study, to develop a high-speed (250 km/h) overhead rigid conductor, R-Bar (Rigid Bar), the electrical and mechanical stability was enhanced through the improvement of the cross sectional shape of the R-Bar; the transition structure was also designed for flexibility and natural frequency isolation. In addition, the evaluation of contact forces between a pantograph and the overhead rigid conductor system for 250 km/h train speeds was performed using dynamic analysis.

Evaluation of thermal conductivity in REBCO coated conductor

  • Yong-Ju, Hong;Sehwan, In;Hyobong, Kim;Hankil, Yeom
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.4
    • /
    • pp.78-83
    • /
    • 2022
  • REBCO coated conductors are widely used for HTS power application, high magnetic field magnet application, and etc. A thermal stability of the REBCO conductor is essential for the operation of HTS-based device, and thermal conductivities of the conductor are relevant parameters for modeling cryogenic heat transfer. REBCO conductors consist of a REBCO layer, copper layers for electrical stabilization and a hastelloy substrate. At cryogenic temperature, thermal conductivity of copper and silver strongly depend on the purity of the material and the intensity of the magnetic field. In this study, thermal conductivities of the laminated composite structure of REBCO conductor are evaluated by using the thermal network model and the multidimensional heat conduction analysis. As a result, the thermal network model is applicable to REBCO conductors configured in series or parallel alone and multidimensional heat conduction analysis is necessary for complex cases of series and parallel configuration.

AC Resistance(Rac) comparison between the new type of coil structure and the annular copper coil to maximize the conductor occupying ratio (고정자 권선 점적율을 극대화 하는 새로운 코일구조와 환형동선 코일구조간의 AC Resistance(Rac) 비교)

  • LEE, Eui-Chun;Kim, Yong-Hoon;LEE, Kang-Won;Lee, Su-Woong;Kwon, Soon-O
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.784-785
    • /
    • 2015
  • This paper proposes a new structure of coil to maximize the conductor occupting ratio(conductor cross sectional area than the cross sectional area inside the slot) of the magnetic core. Further, assuming a case in which the 3-D coil is applied to a real motor. Analyze the current density distribution of the coil conductor by electromagnetic analysis method. Finally the AC resistance was measured according to the frequency of the coils. This expereiment is to calculate a optimal operating frequency to obtain high efficiency operational frequency range of motor.

  • PDF

CPW Directional Couplers with Enhanced Directivity Via Center-Elimination of Backed Conductor (Backed Conductor의 Center-Elimination을 통한 향상된 방향성을 갖는 CPW 방향성 결합기의 설계)

  • 박정훈;이창언;최경민;신철재
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.12
    • /
    • pp.1321-1328
    • /
    • 2003
  • In this paper, we demonstrate that the directivity of the CPW(Coplanar Waveguide) directional coupler with finite-extent backed conductor is enhanced by eliminating center region of backed conductor appropriately. If the backed conductor is removed at center region of couplers, the couplers have two backed conductors. If effective odd mode dielectric constant is decreased at center region, the electrical length for odd mode is changed and phase velocity is same at the directional couplers. Hence, directivity is improved. The eliminated length is solved by an odd and even mode analysis. The designed moderate CPW directional coupler with the proposed compensation structure has excellent directivity and matching characteristic at center frequency in simulation and measurement.

Electro-magnetic Field Analysis of 2-Layer HTS Power Transmission Cable Core (2층 고온초전도 전력케이블 코어의 전자장 해석)

  • 조전욱;주진홍;김석환;배준한;김해종;김해준;성기철;홍정표
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.269-271
    • /
    • 2003
  • A typical HTS power transmission cable has multi-layer conductor structure to increase the current capacity. The tapes of the innermost layer are wound on a round former, and adjacent tapes of another layer are separated by a thin insulating film. In steady state, the total current flows in the conductor layer, and consequently there is magnetic field between the inner and outer layer. This paper describes a magnetic field amplitude around the conductor layer and the HTS tape by a transport current. Also, this paper will help for future cable conductor prototypes.

  • PDF

Electromagnectic Modal Analysis for the Multiscreen Structure with Periodic Slot Array Including Conductor Thickness Effect (유한한 두께를 갖는 평판 상의 주기적 슬롯이 배열된 다중스크린 구조의 전자파 모드 해석)

  • 고지환;조영기
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.40 no.11
    • /
    • pp.1-9
    • /
    • 2003
  • The electromagnectic modal analysis method for the multiscreen structure with periodic slot array with including conductor thickness effect is presented. The multiscreen structure is seen to be exactly equivalent to a microwave guide closed by phase-shift walls. From this viewpoint, the entire generalized scattering matrix of the multiscreen structure is calculated by the cascade connection of the scattering matrices obtained by the modal analysis at guide junctions and the transmission matrices of guide region. The present method is verified in comparison with the results calculated by the previous method of moment for single screen structure. As an application example of the present method, the spatial filter having multiscreen structure is designed and the interesting characteristics such as transmission and reflection coefficient versus frequency & angle are investigated.

Analysis on the Structure Variation of IV Transformed by the Overload (과부하에 의해 변형된 비닐절연전선의 구조변화 분석)

  • 최충석;김형래;송길목;김향곤;김동욱;김동우
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.398-401
    • /
    • 2002
  • When the current flows over the allowable current due to the overload, it causes electric disaster such as an electrical fire and an electric shock by short current or leakage of electricity because the covering is deteriorated according to the heating action. In this paper, for the wire(IV 1.6mm) used as interior wiring, we analyzed a variation of the surroundings temperature, the form and the structure of a covering, and the crystal structure of a conductor. In the result of this experiment, the surroundings temperature at the allowable current of 300% rose to about 47$^{\circ}C$, and it rose up to the maximum allowable temperature of the wire at 400%. Consequently, it was broken within one minute at 500%. In the analysis of a metallograph, the conductor broken by the over current showed the dendrite. These analyses result will be applied to judging the electrical fire.

  • PDF

Transport Loss Characteristic of the Bifilar Pancake Type Fault Current Limiting Coil using Coated Conductor (Coated Conductor를 사용한 무유도 팬케이크형 한류 코일의 통전 손실 특성)

  • Park, Dong-Keun;Bang, Joo-Seok;Yang, Seong-Eun;Ahn, Min-Cheol;Sim, Ki-Deok;Yoon, Yong-Soo;Nam, Kwan-Woo;Seok, Bok-Yeol;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.3
    • /
    • pp.21-25
    • /
    • 2007
  • Superconducting fault current limiter (SFCL) is attractive apparatus to reduce fault current in power grid. Since it is applied to the alternating current (AC) power line, the SFCL has losses in the normal operation. Recently, coated conductor (CC) is noticeable material employed for resistive bifilar winding type SFCL in many research groups. Bifilar structure is expected to have low AC loss by magnetic field offset as compared with the single tape structure in the same length. This paper reports about characteristic of bifilar pancake type coil for SFCL application in AC loss aspect. The bifilar coil is wound using CC with facing on HTS sides each other. Transport AC loss measurement and characteristic analysis of the bifilar coil using CC have been performed at 77K. The test results are compared with the Norris equations and the test results of non-inductively wound paralleled solenoid type coil which is suggested and tested in this group at present.