• Title/Summary/Keyword: conductivity.

Search Result 8,397, Processing Time 0.05 seconds

Correlation Model between Growth Characteristics and Soil Factors of Tulipa edulis Habitat (산자고 자생지의 생육특성 및 토양요인간 상관모형)

  • You Ju-Han;Jung Sung-Gwan;Lee Cheol-Hee
    • Korean Journal of Plant Resources
    • /
    • v.19 no.1
    • /
    • pp.180-188
    • /
    • 2006
  • This study was carried out to offer the raw data on the method of cultivation and ecological characteristic by systematical analysing habitat environment of Tulipa edulis that was expected as medicinal and ornamental resource. The habitat environment was that the altitude was 245 m, the aspect of south, the size of approximately $49\;m^2$, and there was analyzed that Tulipa edulis grew wild in the dryly sunny spot. The vascular plants were summarized as 62 taxa; 28 families, 59 genera, 50 species, 11 varieties and 1 forms, and the resource plants were classified that there were 23 taxa of ornamental plants(37.1%), 43 taxa of edible plants(69.4%), 34 taxa of medicinal plants(54.8%) and 29 taxa of others(46.8%). In the results of soil factors analysis, there showed that acidity was pH 4.9, organic matter content of 4.9%, available $P_{2}O_{5}$ of 3.6 mg/kg, exchangeable $K^+$ of $0.5\;cmol^{+}/kg$, exchangeable $Ca^{2+}$ of $3.0\;cmol^{+}/kg$, exchangeable $Mg^{2+}$ of $0.8\;cmol^{+}/kg$, cation exchange capacity(C.E.C) of $12.3\;cmol^{+}/kg$ and electrical conductivity(EC) of 0.3 dS/m. In the results of correlation analysis between soil factors, exchangeable $Ca^{2+}$ and C.E.C were highly correlative. The growth characteristics of Tulipa edulis were surveyed that height was 7.6 cm, leaf width of 0.6 cm, leaf length of 12.7 cm, flower width of 2.8 cm, peduncle of 5.4 cm and chlorophyll of $34.7\;{\mu}g\;mg^{-1}$. In the results of correlation analysis between growth characteristics, height and peduncle were highly correlative. In the results of correlation analysis between soil factors and growth characteristics, exchangeable $K^{+}$ and leaf length were high relativity but they were confirmed negative relation. In the results of growth model analysis, R-square of leaf width and exchangeable $K^{+}$ was some 86.4% and that of chlorophyll and exchangeable $K^{+}$ was some 83.7%.

Optimum Synthesis Conditions of Coating Slurry for Metallic Structured De-NOx Catalyst by Coating Process on Ship Exhaust Gas (선박 배연탈질용 금속 구조체 기반 촉매 제조를 위한 코팅슬러리 최적화)

  • Jeong, Haeyoung;Kim, Taeyong;Im, Eunmi;Lim, Dong-Ha
    • Clean Technology
    • /
    • v.24 no.2
    • /
    • pp.127-134
    • /
    • 2018
  • To reduce the environmental pollution by $NO_x$ from ship engine, International maritime organization (IMO) announced Tier III regulation, which is the emmision regulation of ship's exhaust gas in Emission control area (ECA). Selective catalytic reduction (SCR) process is the most commercial $De-NO_x$ system in order to meet the requirement of Tier III regulation. In generally, commercial ceramic honeycomb SCR catalyst has been installed in SCR reactor inside marine vessel engine. However, the ceramic honeycomb SCR catalyst has some serious issues such as low strength and easy destroution at high velocity of exhaust gas from the marine engine. For these reasons, we design to metallic structured catalyst in order to compensate the defects of the ceramic honeycomb catalyst for applying marine SCR system. Especially, metallic structured catalyst has many advantages such as robustness, compactness, lightness, and high thermal conductivity etc. In this study, in order to support catalyst on metal substrate, coating slurry is prepared by changing binder. we successfully fabricate the metallic structured catalyst with strong adhesion by coating, drying, and calcination process. And we carry out the SCR performance and durability such as sonication and dropping test for the prepared samples. The MFC01 shows above 95% of $NO_x$ conversion and much more robust and more stable compared to the commercial honeycomb catalyst. Based on the evaluation of characterization and performance test, we confirm that the proposed metallic structured catalyst in this study has high efficient and durability. Therefore, we suggest that the metallic structured catalyst may be a good alternative as a new type of SCR catalyst for marine SCR system.

A Study on the Fertigation of Swine Liquid Manure for Broccoli and Celely Western Vegetables (돈분뇨 발효액을 이용한 녹색꽃양배추 및 양미나리 관비재배 실용화 연구)

  • Kim, Won-Bae;Bae, Won-Ho;Jang, Suk-Woo;Kwon, Young-Gi;Heo, Kweon;Lim, Sang-Cheol
    • Korean Journal of Plant Resources
    • /
    • v.15 no.1
    • /
    • pp.50-56
    • /
    • 2002
  • This study was carried out to optimize the fertigation method using fermented swine liquid manure for the growth of two western vegetables, broccoli and celery. Plants were grown in a rain-shelter house and fertilized with a range of dilutions(efflux 5 dilution=Ef. 5, efflux 10 dilution=Ef. 10, efflux 25 dilution=Ef. 25, and efflux 50 dilution=Ef. 50) of the liquid manure or with conventional application of N : P$_2$O$\_$5/ : K$_2$O = 200 : 70 : 500kg/ha for broccoli, 250 : 210 : 240 kg/ha for celery as controls. After harvest, soil pH and K content decreased after using a high concentration of the liquid manure, Ef. 5, than after treatment with weaker concentrations at Ef. 25 and Ef. 50. On the other hand, soil electrical conductivity, content of P$_2$O$\_$5/, organic matter, total nitrogen, and NO$_3$-N at Ef. 5 increased as concentration of swine liquid manure increased. After harvest, available P$_2$O$\_$5/ in plant tissue did not differ significantly between any of the treatments. In broccoli, the lower concentration (Ef. 50) of swine liquid manure increased flowering over the other treatments, perhaps because the level of absorption into the plants is higher with lower concentration. The amounts of K and Ca in plant tissue were greatest after Ef. 25 and Ef. 50 treatments. Plant growth was best at Ef. 50 in broccoli, head height, head width, and head weight were the best with Ef. 25 and Ef. 50 treatments after harvest. In celery, leaf length was greater after Ef. 25 and Ef. 50 treatments than any other treatments. Total yield of celery of Ef. 25 and Ef. 50 treatments was twice that of conventional cultivation. On the other hand, yield severely decreased after application of high-concentration treatment at Ef. 5. In conclusion, fertigation of swine liquid manure, diluted in the range of Ef. 25 to Ef. 50, could improve yield and quality in broccoli and celery.

Study on Analysis of the Proper Ratio and the Effects of Low Impact Development Application to Sewage Treatment District (하수처리구역 내 LID 적용에 대한 적정비율 및 효과분석 연구)

  • Shin, Hyun Suk;Kim, Mi Eun;Kim, Jae Moon;Jang, Jong Kyung
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.12
    • /
    • pp.1193-1207
    • /
    • 2013
  • Increase of impervious area caused by overdevelopment has led to increase of runoff and then the problem of flooding and NPS were brought up. In addition, as decrease of base flow made groundwater level to decline, a stream that dries up is issued. low impact development (LID) method which is possible to mimic hydrological water cycle, minimize the effect of development, and improve water cycle structure is proposed as an alternative. As introduction of LID in domestic increases, the study on small watershed is in process mainly. Also, analysis of property of hydrological runoff and load on midsize watershed, like sewage treatment district, is required, the study on it is still insufficient. So, area applying LID practices from watershed of Dongrae stream is pinpointed and made the ratio and then expand it to watershed of Oncheon stream. Among low impact development practices, Green Roof, Porous Pavement, and Bio- retention are selected for the application considering domestic situations and simulated with SWMM-LID model of each watershed and improvement of water cycle and reduction of non-point pollution loads was analysed. Improvement of water cycle and reduction of non-point pollution loads were analyzed including the property of rainfall and soil over long term simulation. The model was executed according to scenario based on combination of LID as changing conductivity in accordance with soil type of the watershed. Also, this study evaluated area of LID application that meets the efficiency of conventional management as a criteria for area of LID practices applying to sewer treatment district by comparing the efficiency of LID application with that of conventional method.

Estimations on the Water Purification of Forest by Analyzing Water Quality Variations in Forest Hydrological Processes (산지(山地) 물순환(循環) 소과정(素過程)에 있어서 수질변화(水質變化)의 추적분석(追跡分析)에 의한 산림(山林)의 환경적(環境的) 정화기능(淨化機能)의 계량화(計量化) 연구(硏究))

  • Lee, Heon-Ho
    • Journal of Korean Society of Forest Science
    • /
    • v.86 no.1
    • /
    • pp.56-68
    • /
    • 1997
  • This study was carried out to evaluate the capacity of environment purification of forest and to reveal formation processes of stream water quality by evaluating water quality variations in forest hydrological processes. Water quantity, pH, electric conductivity(EC), dissolved oxygen(DO), and dissolved matter concentrations were monitored in open rainfall, throughfall, stemflow, litter flow and short-term stream flow for one unit storm, and also for those were monitored in long-term stream flow in Palgong, Yongsung, and Daedong catchments. The results were summarized as follows; 1. pH and DO values of stream flow were increased as the flux increased but EC values were decreased. 2. pH values of stemflow and throughfall were decreased with the lapse of rainfall time with lower values than open rainfall. Arid EC values were higher in initial rainfall period but lower gradually with the lapse of time than open rainfall. In litter flow, pH values were lower than open rainfall but EC values were higher. In stream flow, pH values of stream flow showed a high level in initial rainfall period and decreased remarkably with the lapse of time, but it recovered after the rainfall stopped. And however, the values of EC showed almost reverse tendency. DO values of litter flow and stream flow were decreased gradually with the lapse of time in litter flow and stream flow but there were no any tendency in open rainfall, stemflow and throughfall. 3. pH values of stemflow and throughfall in Quercus acutissima were higher than in Pinus densiflora, but EC values were lower. Total amount of canons in stemflow was higher in Pinus densiflora than in Quercus acutissima. 4. pH, DO, EC and total amount of cation values in hydrological processes were in the order of; litter flow

  • PDF

Vegetation Structure and Site Environment of Natural Habitat of an Endangered Plant, Viola websteri (멸종위기 식물 왕제비꽃 자생지의 식생구조 및 입지환경)

  • Song, Jae-Mo;Lee, Gi-Yeoung;Kim, Nam-Young;Yi, Jae-Seon
    • Journal of Korean Society of Forest Science
    • /
    • v.99 no.3
    • /
    • pp.267-276
    • /
    • 2010
  • This study was performed to obtain basic data about vegetation structure and site environment of rare and endangered plant, viola websteri in five natural habitats. The dominant species of Hongcheon habitat were Pyrus pyrifolia (tree layer), Morus bombycis (subtree layer), Pyrus pyrifolia (shrub layer) and Isodon inflexus (herb layer). Mt. Yeonin habitat were dominated by Quercus mongolica (tree layer), Morus bombycis (subtree layer), Philadelphus schrenckii (shrub layer) and Viola websteri (herb layer). Mt. Yumyung habitat were dominated by Cornus controversa (tree layer), Morus bombycis (subtree layer), Fraxinus rhynchophylla (shrub layer) and Adenocaulon himalaicum (herb layer). Mt. Daebu habitat were dominated by Acer mono (tree layer), Staphylea bumalda (subtree layer), Staphylea bumalda(shrub layer) and Dryopteris crassirhizoma (herb layer). And the dominant species of Mt. Worak habitat were Larix leptolepis (tree layer), Fraxinus rhynchophylla (subtree layer), Alangium platanifolium var. macrophylum (shrub layer) and Adenocaulon himalaicum (herb layer). It was found out that the average acidity of soil pH was 5.23; 0.30ds/m for electron conductivity; 12.6% for organic matter content; 0.68% for total nitrogen; 21.66 ppm for available phosphorous; and 23.45 cmol(+)/kg for CEC. Interchangeable cation was decreased in order of $Ca^{2+}$ > $Mg^{2+}$ > $K^{2+}$. Viola websteri had positive association with Polygonatum odoratum var. pluriflorum and Geranium thunbergii but negative association with Poa sphondylodes. Species diversity index(H'), maximum Species diversity index (H' max), evenness(J') and dominance (1-J'), of investigated sites ranged 0.6816 (Mt. Worak)~0.9656 (Mt. Daebu), 1.0000 (Mt. Yeonin)~1.3010 (Hongcheon, Gangwon), 0.5330 (Mt. Worak)~0.8947 (Mt. Daebu) and 0.1053 (Mt. Daebu)~0.4670 (Mt. Worak) in woody layer and 1.0414 (Mt. Yumyung)~1.3295 (Mt. Worak), 1.4314 (Mt. Yumyung)~1.6435 (Mt. Daebu), 0.6984 (Hongcheon, Gangwon)~0.8356 (Mt. Worak) and 0.1644 (Mt. Worak)~0.3016 (Hongcheon, Gangwon) in herb layer, respectively.

Detection of Sea-water Intrusion Caused by Tidal Action Using DC Resistivity Monitoring (전기비저항 모니터링을 이용한 해수침투 파악)

  • Hwang, Hak-Soo;Lee, Sang-Kyu;Ko, Dong-Chan;Kim, Yang-Soo;Park, In-Hwa
    • Geophysics and Geophysical Exploration
    • /
    • v.3 no.1
    • /
    • pp.1-6
    • /
    • 2000
  • The 1 $km^2$ area studied is located in Sukchun-ri, Hwasung-koon, the southern part of Kyeonggi-do. Even though this site has been known as a contaminated area caused by seawater intrusions, geophysical and geochemical surveys have never been carried out at the site to determine the extent of the seawater contamination and to investigate whether the seawater intrusion is in progress. The purpose of this study is to determine the extent of seawater contamination and a preferred channel of the seawater intrusion using geophysical methods such as DC resistivity surveys with Schlumberger array and a dipole-dipole array. In order to determine whether the seawater intrusion is in progress in the area, DC resistivity monitoring with Schlumberger array was performed. According to the resistivity map obtained from the inversion of the resistivity data measured with Schlumberger array, the study area is divided into two districts as relatively lowly resistive (less than 30 ohm-m) and highly resistive (more than 30 ohm-m) areas. The distribution of the lowly resistive area is consistent with the distribution of the layer composed of clay minerals, and the resistivity of this layer decreases slowly as approaching to the old seashore. Hydrogeological analysis shows that the clay layer within a distance of about 200 m from the seashore has been already contaminated by sea-water and its electric conductivity is 8 times higher than that of the sand layer covered by the clay layer. According to the results of the 2-dimensional DC resistivity surveys with a dipole-dipole array, there are two preferred channels of the seawater intrusion in the site, and both the channels are in the NW-SE direction from the old seashore. The lowly resistive zone in the southern channel extends to a depth of 80 m. The DC resistivity monitoring with Schlumberger array was carried out along the preferred channel which has the low resistivity Bone (fracture zone) that extended to a depth of 80 m. The time series of apparent resistivity, measured at a distance of 260 m from the old coast line, fluctuates with a period of 12 hours. From these observations, it can be concluded that the seawater intrusion caused by tidal action is still in progress along the fractured zone interpreted by the DC resistivity surveys with a dipole-dipole array.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2008 (설비공학 분야의 최근 연구 동향: 2008년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Choi, Chang-Ho;Lee, Dae-Young;Kim, Seo-Young;Kwon, Yong-Il;Choi, Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.12
    • /
    • pp.715-732
    • /
    • 2009
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2008. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends in thermal and fluid engineering have been surveyed in the categories of general fluid flow, fluid machinery and piping, new and renewable energy, and fire. Well-developed CFD technologies were widely applied in developing facilities and their systems. New research topics include fire, fuel cell, and solar energy. Research was mainly focused on flow distribution and optimization in the fields of fluid machinery and piping. Topics related to the development of fans and compressors had been popular, but were no longer investigated widely. Research papers on micro heat exchangers using nanofluids and micro pumps were also not presented during this period. There were some studies on thermal reliability and performance in the fields of new and renewable energy. Numerical simulations of smoke ventilation and the spread of fire were the main topics in the field of fire. (2) Research works on heat transfer presented in 2008 have been reviewed in the categories of heat transfer characteristics, industrial heat exchangers, and ground heat exchangers. Research on heat transfer characteristics included thermal transport in cryogenic vessels, dish solar collectors, radiative thermal reflectors, variable conductance heat pipes, and flow condensation and evaporation of refrigerants. In the area of industrial heat exchangers, examined are research on micro-channel plate heat exchangers, liquid cooled cold plates, fin-tube heat exchangers, and frost behavior of heat exchanger fins. Measurements on ground thermal conductivity and on the thermal diffusion characteristics of ground heat exchangers were reported. (3) In the field of refrigeration, many studies were presented on simultaneous heating and cooling heat pump systems. Switching between various operation modes and optimizing the refrigerant charge were considered in this research. Studies of heat pump systems using unutilized energy sources such as sewage water and river water were reported. Evaporative cooling was studied both theoretically and experimentally as a potential alternative to the conventional methods. (4) Research papers on building facilities have been reviewed and divided into studies on heat and cold sources, air conditioning and air cleaning, ventilation, automatic control of heat sources with piping systems, and sound reduction in hydraulic turbine dynamo rooms. In particular, considered were efficient and effective uses of energy resulting in reduced environmental pollution and operating costs. (5) In the field of building environments, many studies focused on health and comfort. Ventilation. system performance was considered to be important in improving indoor air conditions. Due to high oil prices, various tests were planned to examine building energy consumption and to cut life cycle costs.

CNT-Ni-Fabric Flexible Substrate with High Mechanical and Electrical Properties for Next-generation Wearable Devices (차세대 웨어러블 디바이스를 위한 높은 기계적/전기적 특성을 갖는 CNT-Ni-Fabric 유연기판)

  • Kim, Hyung Gu;Rho, Ho Kyun;Cha, Anna;Lee, Min Jung;Ha, Jun-Seok
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.2
    • /
    • pp.39-44
    • /
    • 2020
  • Recently, numerous researches are being conducted in flexible substrate to apply to wearable devices. Particularly, Conductive substrate researches that can implement the wearable devices on clothing are massive. In this study, we formed fiber substrate spraying CNT and Pd mixed solution on it and plated metal layer with electroless plating. Used SEM equipment and EDS analysis to analysis structure of the plated fiber substrate and discovered Ni layer was created. For check electrical properties, mapping was performed to check surface resistance and distribution of resistance of electroless plated fiber substrate with 4-point probe. It was confirmed that conductivity was improved as the duration of electroless plating was increased, and it was found that distribution of resistance by surface location was uniform. Changes in resistance due to mechanical stress were measured through tensile, bending, and twisting tests. As a result, it was confirmed that resistance change of flexible substrate gradually disappeared as plating time increased. Using UTM (Universal testing machine), it was analyzed mechanical properties of the electroless plated substrate with respect to changes in plating time were improved. In the case of conductive fiber substrate in which electroless plating was performed for 2 hours, tensile strength was increased by 16 MPa than fiber substrate. Based on these results, we found that Ni-CNT-Fabric flexible substrate is adequate for clothing-intergrated conductive substrate and we positively expect that this experiment shows flexible substrate can adapt to and develop not only a wearable device technology but also other fields needing flexibility such as battery, catalyst and solar cell.

Synthesis and Electrochemical Properties of (La0.6Sr0.4)(Co0.2Fe0.8)O3 cathode for SOFC on pH Control Using Modified Oxalate Method (Modified Oxalate Method 의해 합성한 SOFC용(La0.6Sr0.4)(Co0.2Fe0.8)O3 Cathode의 pH 변화에 따른 특성)

  • Lee, Mi-Jai;Choi, Byung-Hyun;Kim, Sei-Ki;Park, Sang-Sun;Lee, Kyung-Hee
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.4
    • /
    • pp.288-294
    • /
    • 2007
  • The LSCF cathode far Solid Oxide Fuel Cell was investigated to develop high performance unit cell at intermediate temperature by modified oxalate method with different electrolytes and different pH. The LSCF powders employed La, Sr, Co and Fe oxides, oxalic acid, ethanol and $NH_4OH$ solution were synthesized with pH controlled as 2, 6, 7, 8, 9 and 10 at $80^{\circ}C$ Single crystalline phase was obtained from pH $2{\sim}9$. on the other hand, $La_2O_3$ appeared from pH 10. Very fine powder with particle size of 50 nm was obtained at calcination temperature of $800^{\circ}C$ for 4 hours. LSCF cathode synthesized at pH 7 showed the highest electric conductivity in the temperature range of $600^{\circ}C$ to $900^{\circ}C$ its value was 950 S/cm at $900^{\circ}C$ Under same synthesis conditions, polarization resistance of each LSCF cathode was changed with different calcination temperatures. As-prepared powder presented 2.52, 1.54 and $2.58\;{\Omega}$ at $600^{\circ}C$ with ScSZ, 8Y-YSZ and GDC as its electrolyte respectively after calcination at $800^{\circ}C$ for 4 hours.