• Title/Summary/Keyword: conduction loss

Search Result 447, Processing Time 0.028 seconds

Bone Conduction Loss in Chronic Otitis Media (만성중이염에서의 골도장애)

  • 김종선;김시영
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1979.05a
    • /
    • pp.3.2-3
    • /
    • 1979
  • Bone conduction loss is one of the most common complication in chronic otitis media, and is mostly high frequency loss. Of 233 tympanomastoidectomy ears, 187 ears were considered eligible for this study. A histopathological change was examined in the natural otitis media of guinea pigs. It is our intention to analyze the pattern of bone conduction loss in chronic otitis media, and to correlate this findings with clinical and pathological changes in human and animal otitis media. l) In unilateral cases, a significant difference in bone conduction threshold was observed between normal and diseased ears, and between each frequency with significant interaction between 2KHz and 4KHz (p 0.01). 2) Using one way analysis of variance, mean bone conduction was compared with the duration of disease. We observed a significant difference (p 0.05) between each group of duration, except between 11-15 and 15-20 years group. 3) A comparison of bone conduction between stapes loss group and intact stapes group revealed significant t ratio (p 0.01) at each frequency. The effect of stapes loss on each frequency was evaluated, using one way analysis of variance. there were significant difference(p 0.05) between 250Hz and 500Hz. and between 2KHz and 4KHz. 4) A comparison of bone conduction between round window obliteration and nonobliteration group revealed significant t ratio (p 0.01) at each frequency. Using one way analysis of variance. the effect of round window obliteration was evaluated in each frequency. We observed significant difference (p 0.05) between 250Hz and 500Hz. and between 2KHz and 4KHz. 5) A comparison of bone conduction between cholesteatoma and non -cholesteatoma group revealed significant t ratio (p 0.01) only in 2KHz and 4KHz. No significant differency was observed in mean bone conduction. 6) In a histopathological study of natural otitis media in guinea pig, we observed inflammatory infiltration of the round window membrane, serofibrinous precipitate in the scala tympani, and degeneration of the organ of Corti most significant near the basal turn. These changes would explain high tone bone conduction loss in the process of chronic otitis media.

  • PDF

Power Factor Correction of the Single Stage AC/DC Converter with Low Conduction Loss and High Efficiency (고효율, 저손실을 갖는 1단 교류/직류 변환기의 역률제어)

  • 류명효;차영길;최병조;김흥근
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.418-422
    • /
    • 1998
  • A new single stage AC/DC converter based on the forward converter is proposed. The proposed converter offers both the high power factor and the direct conversion from ac line to dc output voltage. Also, the proposed converter reduces the diode conduction loss, so improves the overall efficiency of the converter, compared with other alternatives. The principles of operation and the simulation results of the proposed converter are presented. A 100 W prototype was built and tested to show the potential of applications of the proposed converter.

  • PDF

Transient Heat Conduction Through the Ondol Floor and Beat toss to the Ground (온돌의 구들장과 땅바닥의 비정상 열전도 해석)

  • Bae, Soon-Hoon;Kim, Doo-Chun
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.4 no.1
    • /
    • pp.6-17
    • /
    • 1975
  • For a periodic variation of the flue gas temperature the heat conduction through the Ondol floor was analysized. Also the heat loss to the ground was estimated. The floor thermal capacity, as a function of the floor thickness, has strong influence on the time lag of the temperature variation. It is an important design parameter for intermittent heating. Even for the steady periodic variation, there was significant heat loss to the ground below the Ondol floor.

  • PDF

A Study on Internal Loss Analysis of Totem Pole Bridgeless PFC and Efficiency Improvement using Parallel Switch (토템폴 브릿지리스 PFC의 내부 손실 분석과 병렬 스위치를 사용한 효율 개선에 관한 연구)

  • Yoo, Jeong Sang;Gil, Yong Man;Yu, Seung Hyup;Ahn, Tae Young
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.4
    • /
    • pp.22-27
    • /
    • 2020
  • In this paper, a generalized efficiency equation was proposed to estimate the internal loss of the SMPS (switched-mode power supply) with 3 variables. The first variable was an internal loss not related to the load current such as auxiliary power, the second was a loss proportional to the current such as diode loss, and the third was a loss proportional to square of the current such as conduction loss. Especially, theoretical internal losses of the totem pole bridgeless PFC which is widely used for high efficiency SMPS were expressed as output function to compare generalized efficiency equation. In addition, in order to reduce the conduction loss of the switch, when a multiple switch were paralleled, the correlation with the efficiency was analyzed and shown as a graph. In order to confirm the degree of the parallel switch structure on the efficiency improvement, a 2kW class totem pole bridgeless PFC was constructed and the effectiveness of the analysis was confirmed by comparing the generalized efficiency equation and theoretical loss analysis results with experimental data.

Design of Auxiliary Circuit to Reduce Loss of ZVT Interleaved Flyback Converter (ZVT 인터리브드 Flyback 컨버터의 손실 저감을 위한 보조 회로 설계)

  • Jung, Won-sang;Lee, Soon-ryung;Lee, Jong-young;Park, Yun-ji;Won, Chung-yuen;Yi, Je-Hyun
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.43-44
    • /
    • 2017
  • This paper presents design of auxiliary circuit to reduce loss of ZVT interleaved flyback converter. The ZVT interleaved converter using the conventional auxiliary circuit has a large conduction loss due to the constant circulating current in the auxiliary circuit. The auxiliary circuit proposed in this paper, which consists of the coupled inductor and DC-link capacitor, has linearly increasing or decreasing auxiliary current. Then, the conduction loss occurring in the auxiliary circuit is reduced. The validity of the proposed auxiliary circuit is verified with the prototype of 500W.

  • PDF

Simulation and Analysis of Losses of Switching Device for Single Grid-connected Full bridge inverter (단상 계통 연계형 풀브릿지 인버터의 스위치 손실 모의 및 분석)

  • Son, Myeongsu;Lim, Hyun Ji;Cho, Younghoon
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.101-102
    • /
    • 2017
  • This paper presents analysis of losses of switching device for full bridge inverter connected to grid. The losses are a dominant factor that judges efficiency of the system. The losses of switching device are divided to switching loss and conduction loss. They are can be estimated by analyzing periodic switching waveforms. The switching loss is generated at the point that turn-on and off. And the conduction loss is generated while the switch is on condition. The estimated losses of switch are compared to simulation result in this paper.

  • PDF

Soft switching high power factor buck converter using loss less snubber circuit (무손실 스너버 회로를 이용한 소프트 스위칭 강압형 고역률 컨버터)

  • 구헌회;변영복;김성철;서기영;이현우
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.6
    • /
    • pp.77-84
    • /
    • 1997
  • buck type converter doesn't appear when an input voltag eis lower than an output voltage. This is the main reason the buck converter has not been used for high power factor converters. In this paper, soft switching high power factor buck converter is proposed. This converter is composed of diode rectifier, input capacitor can be small enough to filter input current, buck converter with loss less snubber circuit. Converter is operated in discontinous conduction mode, turn on of the switching device is a zero current switching (ZCS) and high powr factor input is obtianed. In addition, zero voltage switching (ZVS) at trun off is achieved and switching loss is reduced using loss less snubber circuit. The capacitor used in the snubber circuit raised output voltage. Therefore, proposed converter has higher output voltage and higher efficiency than conventional buck type converter at same duty factor in discontinous conduction mode operation. High power factro, efficiency, soft switching operation of proposed converter is veified by simulation using Pspice and experimental results.

  • PDF

Bidirectional ZVS PWM Sepic/Zeta Converter with Low Conduction Loss and Low Switching Loss (저스위칭손실 및 저도통손을 갖는 양방향 ZVS PWM Sepic/Zeta 컨버터)

  • Paeng, S.H.;Lee, B.C.;Choi, S.H.;Kim, I.D.;Nho, E.C.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.549-551
    • /
    • 2005
  • Bidirectional DC/DC converters allows transfer of power between two dc sources, in either direction. Due to their ability to reverse the direction of flow of power, they are being increasingly used in many applications such as battery charger/dischargers, dc uninterruptible power supplies, electrical vehicle motor drives, aerospace power systems, telecom power supplies, etc. This paper proposes a new bidirectional Sepic/zeta converter. It has low swicthing loss and low conduction loss due to auxiliary communicated circuit and synchronous rectifier operation, respectively. Because of positive and buck/boost-like DC voltage transfer function(M=D/1-D), the proposed converter is very desirable for use in distributed power system . The proposed converter also has both transformerless version and transformer one.

  • PDF

Dielectric Properties of Eicosamethyl Eneasiloxane (Eicosamethyl Eneasiloxane의 유전특성)

  • Cho, Kyung-Soon;Kim, Jae-Hwan;Hong, Jin-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1177-1179
    • /
    • 1993
  • A study has been carried out on the characteristics of dielectric consent and the dissipation factor of Eicosamethyl Eneasiloxane as a function of frequency($30{\sim}10^5$[Hz]) and temperature(-70[$^{\circ}C$] to 65[$^{\circ}C$]). The result shows that a well-defined maxima of the absorption curves characterized by a dipole loss mechanism at a low temperature range. For temperatures in the vicinity of room temperature and higher, the loss in the range of power frequencies are predominantly of ionic nature. The increase of ionic conduction is attributed to the presence of ionizable oxidation products and their increased dissocation feature. The effect of viscosity upon the dipole loss intensity appeared to be considerably less pronounced than that upon ionic conduction loss.

  • PDF

Implementation of Digital Control for Critical Conduction Mode Power Factor Correction Rectifier

  • Shin, Jong-Won;Baek, Jong-Bok;Cho, Bo-Hyung
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.147-148
    • /
    • 2011
  • In this paper, implementation of digital control for critical conduction mode power factor correction (PFC) rectifier is presented. Critical conduction mode is widely used in medium and low power conversion application due to its minimized MOSFET turn-on loss and diode reverse-recovery problem. However, it needs additional zero current detection circuit and maximum frequency limit to properly turn the MOSFET on and avoid the excessive switching loss in light load operation. This paper explains the digital IC implementation and verifies its operation with 200-W prototype PFC rectifier.

  • PDF