• 제목/요약/키워드: conducted EMI

검색결과 139건 처리시간 0.029초

무전극형광램프 ULTRA 150W용 EMI 필터에 대한 연구 (A Study on EMI Filters' construction of 150W Electrodeless fluorescent lamp UTLRA's Ballasts)

  • 박석인;한수빈;유승원;송유진;정학근;정봉만
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.217-221
    • /
    • 2006
  • Offline switching Power supplies have high voltage and high current switching waveforms that generate Electromagnetic Interference(EMI) in the form of both conducted and radiated emissions. Consequently, all off-line power supplies must be designed to attenuate or suppress EMI emissions below commonly acceptable limits. Electrodeless fluorescent lamp's ballasts have AC/DC flyback converter, so we must control the EMI emissions.

  • PDF

전기역학적 임피던스 기법을 이용한 강섬유 보강 모르타르의 응결시간 평가 (Measurement of Setting Times of Steel Fiber Reinforced Mortar using Electric-mechanical Impedance Sensing Technique)

  • 이준철;김화중
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.183-184
    • /
    • 2016
  • This study investigated the evolution of electro-mechanical impedance (EMI) of piezoelectricity (PZT) sensor embedded in hydrating steel fiber reinforced mortar to determine the setting times of that. Penetration resistance test was also conducted in order to justify the valid of EMI sensing technique. As a result, the setting times of steel fiber reinforced mortar can be effectively monitored through the EMI sensing technique using PZT sensor.

  • PDF

Strength Development Monitoring of Concrete Using Smart PZT Transducers

  • Sung, Woo-Shin
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.573-574
    • /
    • 2009
  • The feasibility of electro-mechanical impedance (EMI) sensing technique, utilizing piezo-ceramic (PZT) patches, for online strength gain monitoring of early age concrete is investigated. An experimental study is conducted on PZT patch instrumented concrete specimens. The applicability of the EMI sensing technique for strength gain monitoring is discussed.

  • PDF

변압기 지역 코로나 전자파 간섭에 의한 계측제어설비 영향에 관한 연구 (A Study on the Effects of I&C Systems by EMI Generating from Corona Discharge at Transformer Area)

  • 민문기;이재기;박진엽;김희제
    • 전기학회논문지
    • /
    • 제63권2호
    • /
    • pp.266-271
    • /
    • 2014
  • The Electromagnetic Interference(EMI) generating from corona discharge of transformer area can interference the digital Instrument and Control(I&C) systems located nearby transformers. When the potential gradient of the electric field around the conductor is high enough to form a conductive region but not high enough to cause electrical breakdown to nearby objects, the EMI of corona discharge emits with the conducted and radiated noise and it interferences the signals of the I&C systems. Since digital I&C systems have an efficiency and competitive price, the analog I&C systems have been upgraded and displaced with the digital I&C systems but which have less EMI Immunity. There was no assessment to I&C systems by EMI generating corona discharge nearby transformers. When the safety-related I&C systems are installed in plants, the verification of equipment EMI should be done not in site-specific test but in test facilities. There are the need to do the site-specific EMI evaluation of corona discharge nearby transformers. This paper assesses the margin between plant emission limits and the highest composite plant emission of corona. When the non safety-related I&C systems are placed in transformer area, it suggests the appropriate radiated susceptibility level to EMI of corona discharge.

서포트 벡터 머신과 공정능력분석을 이용한 군 통신 쉘터의 EMI 차폐효과 안정 포인트 탐색 연구 (A Study on Searching Stabled EMI Shielding Effectiveness Measurement Point for Military Communication Shelter Using Support Vector Machine and Process Capability Analysis)

  • 구기범;권재욱;진홍식
    • 한국산학기술학회논문지
    • /
    • 제20권2호
    • /
    • pp.321-328
    • /
    • 2019
  • 군 통신 쉘터는 내부에 통신 및 환경장비를 탑재하여, 네트워크 중심전에서 다양한 무기체계들의 통합적인 전투력 발휘를 위해 요구되는 정보의 송/수신 기능을 실시간 보장하고 전술환경의 생존성을 극대화시키는 장비이다. 쉘터 내부에 다양한 통신용 장비가 탑재되기 때문에 외부로부터의 전자기 공격에 대한 차페 성능을 반드시 보장해야한다. 본 연구에서는 데이터 마이닝 기법(서포트 벡터 머신)과 통계적 품질관리 기법(공정능력분석)을 이용하여 군 통신용 쉘터에서 차폐성능이 안정된 지점을 탐색하는 연구를 진행하였다. 안정된 지점의 탐색을 위하여 45대 쉘터의 EMI 차폐효과 측정데이터를 활용하였다. 먼저, 차폐효과가 안정되었다고 판단할 수 있는 기준을 세우고 서포트 벡터 머신으로 해당 기준에 부합하는 측정 포인트 집단과 그 외의 집단을 분리, 이 두 집단을 분류할 수 있는 분류 하이퍼플레인을 작성하였다. 그리고 공정능력분석을 이용하여 차폐효과 측정 데이터를 분석, 공정능력지수가 높은 측정 포인트와 서포트 벡터 머신의 하이퍼플레인으로 분류한 측정 포인트를 상호 비교함으로써 분류된 측정 포인트의 타당성과 차폐효과가 안정된 정도를 분석하였다. 분석 결과, 24개의 측정포인트에서 안정된 차폐 성능을 보유하고 있음을 확인하였다.

차세대 고속전철 주행에 따른 전도성 노이즈 요인분석 (Analysis of conducted EMI source on powering mode of next generation high-speed train)

  • 김재문;김세찬;김학만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.948-949
    • /
    • 2008
  • In this paper, an effect on power conversion unit in next generation high-speed train by loss of contact between a contact wire and pantograph supplied electrical power to high-speed train are investigated. One of the most important needs accompanied by increasing the speed of high-speed train is reduced that arc phenomenon by loss of contact brings out EMI. To analysis of conducted EMI source on powering mode of next generation high-speed train, it is necessary electrical modeling system between the contact wire and the pantograph according with loss of contact. Therefore analytical model of a contact wire and a pantograph is constructed to simulate the behaviour of loss of contact. The reliability of the modeling system is verified by simulation implementation on loss of contact.

  • PDF

Output filter design for conducted EMI reduction of PWM Inverter-fed Induction Motor System

  • Kim Lee-Hun;Won Chung-Yuen;Kim Young-Seok;Choi Se-Wan
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.761-767
    • /
    • 2001
  • In this paper, filtering techniques to reduce the adverse effects of motor leads on high-frequency PWM inverter fed AC motor drives will be examined. The filter was designed to keep the motor terminal from the cable surge impedance to reduce overvoltage reflections, ringing, and the dv/dt, di/dt. Therefore, filtering techniques are investigated to reduce the motor terminal overvoltage, ringing, and EMI noise in inverter fed ac motor drive systems. The output filter is used to limit the rate of the inverter output voltage and reduce EMI(common mode noise) to the motor. The performance of the output filter is evaluated through simulations (PSIM) and experiment on PWM inverter-fed ac motor drive(3phase, 3hp(2.2kw), input voltage 220/380V, induction motor). An experimental PWM drive system reduction of conducted EMI was implemented on an available TMS320C31 microprocessor control board. Finally, experimental results showed that the inverter output filter reduces more CM noise than the LPF(low pass filter) and reduce overvoltage and ringing at the motor terminal.

  • PDF

상호 변조 및 불요 신호에 대한 탐색레이더 부 체계의 EMI 시험 기법 (Research of the EMI Test Methods for a Surveillance Radar Subsystem Against the Intermodulation and Undesired Signals)

  • 이진호
    • 한국군사과학기술학회지
    • /
    • 제10권2호
    • /
    • pp.84-89
    • /
    • 2007
  • MIL-STD-461E, EMI military standard for the equipment and subsystems, requires reception characteristic tests to verify the susceptibility of a receiver against the jntermodulation and spurious signals. Because the CS103 and CS104 of MIL-STD-461E show the test configuration of the equipment unit like a traditional receiver, it is possible to verify the susceptibility only for the reception signal through analog filters. However, at present when software programming techniques make a progress, the CS103 and CS104 tests need to evaluate the reception signal of the subsystem which includes both the digital filtering effects and analog filter characteristics. These test and evaluation techniques applied to a surveillance radar subsystem. This paper researched the EMI test methods in order to confirm feasibility of these test and evaluation techniques. Also the test results are compared and analyzed.

CM Choke의 누설 인덕턴스를 이용한 리액터 설계 (Reactor Design Using the Leakage Inductances of CM Choke)

  • 고종진;최지환;김성기;박종진;조동윤;노정욱
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.277-278
    • /
    • 2012
  • 본 논문은 고조파(Harmonics) 규제 만족을 위해 사용되는 리액터와 EMI(Electro-Magnetic Interference) 필터 회로에 관한 것으로서, 기존의 고조파 규제와 150kHz ~ 30MHz 대역의 EMI CE(Conducted Emission) 규제를 만족하기 위하여 각각 사용했던 리액터와 EMI 필터의 CM Choke 코일을 CM Choke의 누설 인덕턴스를 이용하여 CM Choke 코일 하나로 대체한다. 결과적으로 기존의 리액터 소자를 제거함으로써 사용 소자 개수 저감에 따른 부피 및 가격 저감을 실현할 수 있다는 장점을 가진다. 또한 실제 제품에 적용해 고조파, EMI 측정결과 문제가 없음을 검증하였으며, 온도 특성도 문제가 없음을 확인했다.

  • PDF

압전소자를 이용한 시멘트계 재료의 응결 특성 평가 (Setting Characteristic Assessment of Cementitious Materials using Piezoelectric Sensor)

  • 이창준;이준철;신성우;김화중
    • 한국건축시공학회지
    • /
    • 제16권5호
    • /
    • pp.389-395
    • /
    • 2016
  • 본 연구에서는 압전소자의 EMI 신호변화를 이용하여 시멘트계 재료의 응결특성을 평가하였다. 시멘트 페이스트에 매립된 PZT센서의 수화시간에 따른 EMI 신호변화를 비카트침 시험과 간이단열시험을 통한 수화온도곡선과 비교하였다. 실험결과, 시멘트 페이스트가 수화함에 따라 PZT센서의 EMI 공진피크와 공진주파수의 변화가 나타났으며, 이러한 변화시점은 비카트침 시험과 간이단열시험을 통한 수화온도곡선으로부터 획득한 응결시간과 부합하는 것으로 나타났다.