For an effective warfare under the condition of NCW, the sharing of data between systems must be essential. Thus, the standardization and the integration of data which is considered as the MND-EA improvement and the Megacenter is important. The purpose of this research is to investigate the factors that affected the BI(Behavioral Intention to USE) by using the TAM(Technology Acceptance Model), That is to introduce the MDM into the national defense field which is an issue in every agency sector for data sharing. Also, based on the implementation architecture of Gartner which applies depending on the business enterprise type, the preferred architecture should be selected considering the national defense environment and the characteristics, and suggest an effective MND-MDM plan by analysing the effects on the BI. The survey was done through 19th September till the 7th of October 2011, by investigating the people in charge of the development and maintenance of the national defense information systems and the SI company's national defense team people who have experienced the development of the national defense information systems.
This paper analyzes the output characteristics of a self excited induction generator with isolated mode according to change of its speeds and loads for building a hybrid electric propulsion system in special purpose ships by using power take off. The induction generators are being considered as an alternative choice to the well-developed generators because of their lower unit cost, inherent ruggedness, operational and maintenance simplicity. However, the generator working by stand alone has a few problems that the reactive power is required to establish the air gap magnetic flux, and the induced voltage and magnetizing current fluctuate when the load is varied. In spite of its advantages, basic design data of the capacitor bank and behaviors of the output characteristics of the generator are not sufficient for the system. Based on the operating condition(speed range of main engine) of the target boat, a reduced experimental equipment system was constructed to analyze the output characteristics of the SEIG. And a suitable capacitor bank of a stand-alone generator and its output characteristics under various loads was investigated in detail through these experiments. According to the experimental result, it was confirmed that the capacitor bank should be $70{\mu}F{\sim}100{\mu}F$, and the proper SEIG induced voltage should be DC 80 V ~ 250 V in order to storage electrical energy into a battery.
This study is related with support system plans of public-private convergence for emergency recovery services to fire victims. The current issues are analysed from the condition and problem analysis results of emergency recovery activities for fire victims. And building plans of an integrated support system based on the government and private sector cooperation are proposed. Overall, the system shows that the government is responsible for the functionality of management and supervision for the system operation, and the private is responsible for the functionality of specialized agencies for practical emergency recovery. Consequently, support system plans include with infrastructure maintenance of laws and regulations, contracting-out of the support system, stable supply of operating budget and function strengthening of public-private convergence for emergency recovery. Especially, plan for stable supply of operating budget in detail including with establishment of the fund and self-financing composition of private corporations for emergency recovery services is proposed. The results of this study will lead strengthening of fire safety welfare and social safety nets at future.
In the United States, the prospective payment system(PPS), under which diagnosis related groups (DRGs) are used to reimburse hospitals for the care of Medicare patients since 1983, Study results showed that the PPS is having a major impact on the quantity of services especially of hospital length of stay. The PPS has increased the likelihood that a patient will be discharged home in an unstable condition and the use of nursing homes or long term care facilities increased. Still, it is insufficient to conclude that the PPS has decreased the Medicare total expenditure, but relatively sufficient to conclude that the quality of care hasn't changed. The maintenance of the quality resulted from the systemic "check-and-balance" composed of three factors; (1) The doctors are reimbursed based on the fee-for-service system, (2) hospitals contact with doctors under the attending system, and (3) there are some public hospitals. In Korea, the reimbursement for hospitals and doctors are not divided, the hospitals have doctors as employees, and 90% of hospitals are private. These differences may weaken the "check-and-balance" existing in the U.S. system. And there are few long term care facilities and the diagnostic coding system using in pilot test are not suitable for Korean situation. In conclusion, for successful implementation of the DRG payment system in Korea, the government should establish the "check-and-balance" system in the health sector to make sure the quality of care before the implementation.
Korean Journal of Construction Engineering and Management
/
v.10
no.6
/
pp.67-77
/
2009
Infrastructure asset management can be defined as the long term and cost effective management strategy to meet the required service level. In most developed countries, the major motivations of the introduction of asset management are increment in number of assets, extension of maintenance field, accounting approaches of public facilities, performance-based FM(Facility Management), limitations of public funds and public-private partnership, life cycle cost approach, and the development of information technology. This paper discusses the strategic and stepwise methods of introducing infrastructure asset management. Strategic approaches are suggested to develop the practical methods of condition and value assessment of assets, and long-term capital investment plan for optimized decision making(ODM). Required systematic processes are analyzed in terms of resource and technical limitations and detailed implementation plan for each development phases are suggested.
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
/
v.17
no.4
/
pp.57-63
/
2003
Aluminum Stranded Conductors Steel Reinforced (ACSR) in overhead transmission lines have slowly degraded due to pollutants in the air for a long period of time, so in the 2000, a number of them has been exceeded over their forecasted useful life. Since most of them are faced with assessment their present conditions in regard to economical maintenance, in this paper, we have suggested a method in order to evaluate the current condition of aged conductors by using dominant parameters such as elapsed years, environment index, and conductor configuration. A diagnostic system for predicting the deterioration grades corresponding to the lifetime of aged conductors is described, which is designed as an Adaptive Neuro-fuzzy Inference System (ANFIS) based on knowledge and experiences of experts. Applying this diagnostic system to practical transmission lines in domestic, it is shown that the system can be effectively used as a guide to perform nondestructive diagnosis and economical operation for old ACSR conductors.
The objective of this study is the investigation and analysis of information on the conservation and the sustainable use of coastal wetlands based on the awareness of local residents in Kang-hwa island, Tae-an and Seo-chon. The results are summarized as follows: The degree of the satisfaction on the natural environment is in the order of Tae-an, Kang-hwa and Seo-chon. This order is accorded with the order of the goodness of natural environment. The order for the degree of the satisfaction on the living environment is same as the order for the satisfaction degree on the natural environment. Especially, residents of Seo-chon are not satisfied with the living environment. The residents of all regions are not satisfied with the socio $.$ economic environment. The local resident of Kang-hwa and Tae-an, where natural environment is well-conserved, prefer conservation to development of the region. On the other hand, the local residents of Seo-chon have relatively low preference for conservation of the region. These results show the following consideration for the ideal method of management for the conservation and sustainable development of coastal wetlands. In case of Kang-hwa island, where the, condition the natural environment is well conserved, should be managed with the minimum development with maintenance of the current state must be driven.
Kim, Heung-Youl;Kim, Hyung-Jun;Cho, Kyung-Suk;Lee, Jae-Sung;Kwan, Ki-Hyuk
Fire Science and Engineering
/
v.23
no.3
/
pp.110-120
/
2009
In tunnel, though the frequency of fire occurrence is relatively lower than other structures, the characteristics of sealed space tends to cause the temperature to rapidly rise to more than $1000^{\circ}C$ within 5minutes after fire, which might eventually lead to a large fire that usually results in a loss of lives and the damage to the properties, not to mention a huge cost necessary for repair and maintenance after fire. We have developed various conditions of the heating furnace and the method to install a thermo couple within the furnace based on EFNARC and KS F 2257-1. Referring to tunnel fire scenarios, it clarified the heat transfer characteristics of concrete PC panel lining depending on fire intensity (ISO, $1^{\circ}C$/SEC, MHC, RWS), and to identify the range of thermal damage, the evaluation was carried out using ITA standard. As a result, 30mm under ISO fire condition, 20mm under $1^{\circ}C$/SEC, 100mm under MHC and 50mm under RWS were measured. And when it comes to spalling, 30mm was measured under RWS and MHC.
The Journal of the Korea institute of electronic communication sciences
/
v.16
no.4
/
pp.643-652
/
2021
Accidents or faults in the transmission and distribution system are never completely avoidable, and short-circuit and earth faults are occurs despite the efforts of the TSO and DSO. Recently, the connection to the transmission and distribution system of large-capacity new and renewable distributed power has increased rapidly and has various effects on the operation of the system. In order to minimize this, connection standards such as FRT (Fault-Ride-Through) have been established to provide wind turbines or solar inverters. In the event of a major faults of the power system, the operation support shall be provided so that the operator can stably operate the system by smoothly performing connection maintenance or rapid system separation. In this paper, in order to appropriately determine whether the FRT condition, which is the grid connection criterion for a representative DERs, is sufficient, a detection system using a PMU (Phasor Measurement Unit) that measures a synchro-phasors was designed and deployment and a system accident due to a generator step-out to analyze and evaluate the proposed system based on the case.
The aim of this study was to determine the condition of supportive periodontal therapy (SPT) in implant patients and the effect of SPT on implant long-term survival. Implants placed at the Dept. of Periodontology, Chonnam National University Dental Hospital over a 5-year period, were traced for up to 8 years. Patients who had visited the hospital at least once a year were defined as regular SPT, and patients who were treated by active periodontal therapy were defined as patients with periodontitis. Kaplan-Meier survival analysis was performed based on the observation periods, and the effect of SPT and history of periodontitis on implant survival assessed by chisquare test. A total of 183 patients (age: 21-91, 98 males and 85 females), and 508 implants were used for this study. Three hundred eight implants were under SPT and 87 implants was under regular SPT. For the patients with periodontitis 136 implants were placed. The 5-year survival rate was 94.8%. The overall survival rate in patients who received SPT was 97.1% and 91.0% for those who did not (p=0.004). The survival rate in patients who received regular SPT was 97.7%, and 96.8% for patients received irregular SPT. The survival rate was 93.4% in patients with periodontitis and 95.2% in patients without periodontitis. Among patients with periodontitis, the survival rate was 100.0% in patients who received regular SPT and 89.2% for irregular SPT (p=0.012). These results suggest that regular SPT improves implant survival rate and is more effective in patients with periodontitis.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.