• 제목/요약/키워드: concrete shear key

검색결과 222건 처리시간 0.028초

Static behaviour of bolted shear connectors with mechanical coupler embedded in concrete

  • Milosavljevic, Branko;Milicevic, Ivan;Pavlovic, Marko;Spremic, Milan
    • Steel and Composite Structures
    • /
    • 제29권2호
    • /
    • pp.257-272
    • /
    • 2018
  • The research of shear connectors composed from mechanical couplers with rebar anchors, embedded in concrete, and steel bolts, as a mean of shear transfer in composite connections is presented in the paper. Specific issues related to this type of connections are local concrete pressure in the connector vicinity as well as the shear flow along the connector axis. The experimental research included 18 specimens, arranged in 5 series. Nonlinear numerical analyses using Abaqus software was conducted on corresponding FE models. Different failure modes were analysed, with emphasis on concrete edge failure and bolt shear failure. The influence of key parameters on the behaviour of shear connector was examined: (1) concrete compression strength, (2) bolt tensile strength and diameter and (3) concrete edge distance. It is concluded that bolted shear connectors with mechanical couplers have sufficient capacity to be used as shear connectors in composite structures and that their behaviour is similar to the behaviour of post installed anchors as well as other types of connectors anchored without the head.

대형판조립식 구조 수직.수평접합부의 전단강도에 미치는 보강방법의 영향-수직접합부 및 슬래브-슬래브 수평접합부를 중심으로- (Effects of Reinforcing Method Influnced to the Shear Strength of Vertical and Horizontal Joints in Precast Concrete Large Panel Structures -Focused on the Vertical Joints and Slab-Slab Type Horizontal Joints-)

  • 정란;박현수;조승호
    • 콘크리트학회지
    • /
    • 제8권4호
    • /
    • pp.171-179
    • /
    • 1996
  • PC판넬 조립식 구조의 수직.수평접합부의 유용한 접합형태에 따라 접합부 전단내력을 상승시킬 수 있는 접합부 설계의 기본 형태를 제시하는데 연구의 목적이 있다. 시험체는 수직접합부의 경우 전단키의 개수 및 보강철물의 종류에 변수를 주고 수평접합부의 경우에는 전단키의 갯수 및 가력방향에 변수를 주어 총 22개의 시험체를 제작하여 실험하였다. 결론적으로 수직접합부의 경우, 수평보강철물이 있는 시험체는 기존의 다른 실험결과와 마찬가지로 수평보강철물이 없는 시험체에 비하여 연성이 크게 나타났다. EH한 와이어로프와 원형철근 두 종류의 보강철물을 사용하여 실험한 결과 와이어 로프를 사용한 시험체는 원형철근을 사용한 시험체와 최대내력 및 전단강성 등 전체적인 구조거동이 거의 비슷하게 나타났다.

Key factors affecting the shear behaviour of exterior RC beam-column joints

  • Ricardo, Costa;Paulo, Providencia
    • Structural Engineering and Mechanics
    • /
    • 제85권3호
    • /
    • pp.353-367
    • /
    • 2023
  • An extended parametric study based on nonlinear finite element analyses is performed to assess the key factors affecting the shear behaviour of exterior beam-column joints of unbraced reinforced concrete frames. Extensive results are presented, the major conclusion being that the few shear behaviour models for exterior reinforced concrete beam-column joints available in the literature do not properly account for some of the most influential factors. The present results are also compared with recently published results for interior joints, showing that while some factors have a similar influence on interior and exterior joints others are relevant for only one of these types of joints. This also confirms, numerically, that some resisting mechanisms of exterior joints differ from those of interior joints.

Cyclic behavior of steel beam-concrete wall connections with embedded steel columns (II): Theoretical study

  • Li, Guo-Qiang;Gu, Fulin;Jiang, Jian;Sun, Feifei
    • Steel and Composite Structures
    • /
    • 제23권4호
    • /
    • pp.409-420
    • /
    • 2017
  • This paper theoretically studies the cyclic behavior of hybrid connections between steel coupling beams and concrete shear walls with embedded steel columns. Finite element models of connections with long and short embedded steel columns are built in ABAQUS and validated against the test results in the companion paper. Parametric studies are carried out using the validated FE model to determine the key influencing factors on the load-bearing capacity of connections. A close-form solution of the load-bearing capacity of connections is proposed by considering the contributions from the compressive strength of concrete at the interface between the embedded beam and concrete, shear yielding of column web in the tensile region, and shear capacity of column web and concrete in joint zone. The results show that the bond slip between embedded steel members and concrete should be considered which can be simulated by defining contact boundary conditions. It is found that the loadbearing capacity of connections strongly depends on the section height, flange width and web thickness of the embedded column. The accuracy of the proposed calculation method is validated against test results and also verified against FE results (with differences within 10%). It is recommended that embedded steel columns should be placed along the entire height of shear walls to facilitate construction and enhance the ductility. The thickness and section height of embedded columns should be increased to enhance the load-bearing capacity of connections. The stirrups in the joint zone should be strengthened and embedded columns with very small section height should be avoided.

Evaluation of unsaturated soil slope stability by incorporating soil-water characteristic curve

  • Zhai, Qian;Tian, Gang;Ye, Weimin;Rahardjo, Harianto;Dai, Guoliang;Wang, Shijun
    • Geomechanics and Engineering
    • /
    • 제28권6호
    • /
    • pp.637-644
    • /
    • 2022
  • Loess soils are unsaturated and widely distributed in the northwest zone in China. Many steep slope of unsaturated are observed are observed to be naturally stable. However, a low factor of safety (FoS) for these slopes would be computed from the slope stability analysis following local code practices. It seems that the analyzed results following the local code practices do not agree with the real condition as observed in the field. It is commonly known that soil suction plays an important role in slope stability due to a higher shear strength of the unsaturated soil as compared with that of the saturated soil. In this paper, it is observed that the computed FoS can also be affected by unsaturated unit weight of the soil. However, the effect of unsaturated unit weight of the soil on the slope stability is commonly ignored in engineering practice. Therefore, both the effects of shear strength and unit weight of the unsaturated soil on the computed FoS of unsaturated soil slope are investigated in this study. It is observed that the unsaturated unit weight of soil on the computed FoS increases with increase in slope angle. It is also observed that the effects of the unsaturated shear strength and unsaturated unit weight on the computed FoS are more significant than the effect of 3D analyses compared to the 2D analyses on the FoS.

Joint Shear Behavior Prediction for RC Beam-Column Connections

  • LaFave, James M.;Kim, Jae-Hong
    • International Journal of Concrete Structures and Materials
    • /
    • 제5권1호
    • /
    • pp.57-64
    • /
    • 2011
  • An extensive database has been constructed of reinforced concrete (RC) beam-column connection tests subjected to cyclic lateral loading. All cases within the database experienced joint shear failure, either in conjunction with or without yielding of longitudinal beam reinforcement. Using the experimental database, envelope curves of joint shear stress vs. joint shear strain behavior have been created by connecting key points such as cracking, yielding, and peak loading. Various prediction approaches for RC joint shear behavior are discussed using the constructed experimental database. RC joint shear strength and deformation models are first presented using the database in conjunction with a Bayesian parameter estimation method, and then a complete model applicable to the full range of RC joint shear behavior is suggested. An RC joint shear prediction model following a U.S. standard is next summarized and evaluated. Finally, a particular joint shear prediction model using basic joint shear resistance mechanisms is described and for the first time critically assessed.

비선형유한요소해석을 이용한 수직 스터럽이 있는 RC 짧은 보의 해석 (Analysis of Slender RC Short Beams(a/d<2.5) with Vertical Stirrups using Nonlinear FEM)

  • 정제평;김대중;김우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.259-264
    • /
    • 2002
  • This paper describes an attempt to develop a unified design approach for reinforced concrete short beam failing in shear based on a Arch Factor. Designing for short beam in shear is not as straightforward as designing for flexure due to the complicated interdependency of the variables involved and to the nonexistence of a rational theory tn current design code. Shear failure of reinforced concrete beams with stirrups is influenced greatly because of the actual geometrical shape(a/d) of the concrete and flexural reinforcement steel ratio, stirrup reinforcement ratio and concrete compression strength, size effect etc. The objective of this paper is to present a pilot study to develop a simplified physical model for estimating shear behavior of reinforced concrete short beams. The Key idea incorporated with this model is the Arch factor, introduced by Kim and White.

  • PDF

Web-shear strength of steel-concrete composite beams with prestressed wide flange and hollowed steel webs: Experimental and practical approach

  • Han, Sun-Jin;Kim, Jae Hyun;Choi, Seung-Ho;Heo, Inwook;Kim, Kang Su
    • Structural Engineering and Mechanics
    • /
    • 제84권3호
    • /
    • pp.311-321
    • /
    • 2022
  • In the buildings with long spans and high floors, such as logistics warehouses and semiconductor factories, it is difficult to install supporting posts under beams during construction. Therefore, the size of structural members becomes larger inevitably, resulting in a significant increase in construction costs. Accordingly, a prestressed hybrid wide flange (PHWF) beam with hollowed steel webs was developed, which can reduce construction costs by making multiple openings in the web of the steel member embedded in concrete. However, since multiple openings exist and prestress is introduced only into the bottom flange concrete, it is necessary to identify the shear resistance mechanism of the PHWF beam. This study presents experimental shear tests of PHWF beams with hollowed steel webs. Four PHWF beams with cast-in-place (CIP) concrete were fabricated, with key variables being the width and spacing of the steel webs embedded in the concrete and the presence of shear reinforcing bars, and web-shear tests were conducted. The shear behavior of the PHWF beam, including crack patterns, strain behavior of steel webs, and composite action between the prestressed bottom flange and CIP concrete, were measured and analyzed comprehensively. The test results showed that the steel web resists external shear forces through shear deformation when its width is sufficiently large, but as its width decreased, it exerted its shear contribution through normal deformation in a manner similar to that of shear reinforcing bars. In addition, it was found that stirrups placed on the cross section where the steel web does not exist contribute to improving the shear strength and deformation capacity of the member. Based on the shear behavior of the specimens, a straightforward calculation method was proposed to estimate the web-shear strength of PHWF beams with CIP concrete, and it provided a good estimation of the shear strength of PHWF beams, more accurate than the existing code equations.

Behavior of reinforced concrete beams filled with demolished concrete lumps

  • Wu, Bo;Xu, Zhe;Ma, Zhongguo John;Liu, Qiongxiang;Liu, Wei
    • Structural Engineering and Mechanics
    • /
    • 제40권3호
    • /
    • pp.411-429
    • /
    • 2011
  • In the past decades, recycling use of demolished concrete was almost limited to the types of recycled coarse aggregate with a size of about 5-40 mm and recycled fine aggregate with a size of about 0-5 mm for concrete structures, and reuse of demolished concrete lumps (DCLs) with a size much larger than that of recycled aggregate, e.g., 50-300 mm, has been limited to roadbed, backfilling materials, or discarded to landfills. Treatment processes of DCLs are much simpler than those of recycled aggregate, leading to less cost and more energy-saving. In the future, the amount of demolished concrete is estimated to be much higher, so reuse of DCLs for concrete structures will become necessary. The objectives of this paper are to document the process of making reinforced concrete beams with DCLs, and to discuss the flexural and shear behaviors of those reinforced DCL beams through an experimental program, which includes three beams filled with DCLs and one conventional beam for investigating the flexural strengths and deformations, and 12 beams filled with DCLs and two conventional beams for investigating the shear strengths and deformations. The authors hope that the proposed concept offers another sustainable solution to the concrete industry.

격자형 강합성 바닥판의 수정된 이음부에 대한 휨성능 평가 (Evaluation of the Bending Performance of a Modified Steel Grid Composite Deck Joint)

  • 신현섭;박기태
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권4호
    • /
    • pp.38-47
    • /
    • 2013
  • 프리캐스트 방식에 의해 제작이 가능한 격자형 강합성 바닥판의 이음부로서 콘크리트 전단키와 고장력볼트 체결로 구성된 조립식 이음부가 제안된 바 있다. 본 연구에서는 콘크리트 전단키와 고장력볼트로 구성된 이음부의 휨강성과 휨강도를 향상시키고자 단면상세를 개선하였고, 구조실험을 통해 얻은 결과를 기존 볼트체결 이음부와 비교 분석하였다. 비교분석 결과에 의하면, 전단스터드와 가외철근에 의한 이음부 콘크리트 보강으로 뚜렷한 전단균열 감소효과가 있었다. 모멘트-곡률 관계로부터 구한 휨강성을 서로 비교해 본 결과, 단면개선 전의 이음부에 비해 약 47% 정도 휨강성이 증가한 것을 알 수 있었다. 또한, 휨강도 비교결과에 의하면 개선된 이음부의 휨강도는 개선 전에 비해 약 32% 증가하였다. 개선된 이음부의 휨성능을 이음부가 없는 단면과 비교하면, 휨강도의 경우 동등 수준 이상이었으나, 휨강성의 경우는 약 37% 정도 더 작은 것으로 분석되었다.