• Title/Summary/Keyword: concrete panel

Search Result 537, Processing Time 0.024 seconds

Free vibrations of precast modular steel-concrete composite railway track slabs

  • Kimani, Stephen Kimindiri;Kaewunruen, Sakdirat
    • Steel and Composite Structures
    • /
    • v.24 no.1
    • /
    • pp.113-128
    • /
    • 2017
  • This paper highlights a study undertaken on the free vibration of a precast steel-concrete composite slab panel for track support. The steel-concrete composite slab track is an evolvement from the slab track, a form of ballastless track which is becoming increasingly attractive to asset owners as they seek to reduce lifecycle costs and deal with increasing rail traffic speeds. The slender nature of the slab panel due to its reduced depth of construction makes it susceptible to vibration problems. The aim of the study is driven by the need to address the limited research available to date on the dynamic behaviour of steel-concrete composite slab panels for track support. Free vibration analysis of the track slab has been carried out using ABAQUS. Both eigenfrequencies and eigenmodes have been extracted using the Lanczos method. The fundamental natural frequencies of the slab panel have been identified together with corresponding mode shapes. To investigate the sensitivity of the natural frequencies and mode shapes, parametric studies have been established, considering concrete strength and mass and steel's modulus of elasticity. This study is the world first to observe crossover phenomena that result in the inversion of the natural orders without interaction. It also reveals that replacement of the steel with aluminium or carbon fibre sheeting can only marginally reduce the natural frequencies of the slab panel.

Damped frequencies of precast modular steel-concrete composite railway track slabs

  • Kaewunruen, Sakdirat;Kimani, Stephen Kimindiri
    • Steel and Composite Structures
    • /
    • v.25 no.4
    • /
    • pp.427-442
    • /
    • 2017
  • This paper presents unprecedented damped oscillation behaviours of a precast steel-concrete composite slab panel for track support. The steel-concrete composite slab track is an innovative slab track, a form of ballastless track which is becoming increasingly attractive to asset owners as they seek to reduce lifecycle costs and deal with increasing rail traffic speeds. The slender nature of the slab panel due to its reduced depth of construction makes it susceptible to vibration problems. The aim of the study is driven by the need to address the limited research available to date on the dynamic behaviour of steel-concrete composite slab panels for track support. Free vibration analysis of the track slab has been carried out using ABAQUS. Both undamped and damped eigenfrequencies and eigenmodes have been extracted using the Lancsoz method. The fundamental natural frequencies of the slab panel have been identified together with corresponding mode shapes. To investigate the sensitivity of the natural frequencies and mode shapes, parametric studies have been established, considering concrete strength and mass and steel's modulus of elasticity. This study is the world first to observe crossover phenomena that result in the inversion of the natural orders without interaction. It also reveals that replacement of the steel with aluminium or carbon fibre sheeting can only marginally reduce the natural frequencies of the slab panel.

Static and dynamic analytical and experimental analysis of 3D reinforced concrete panels

  • Numayr, K.;Haddad, R.
    • Structural Engineering and Mechanics
    • /
    • v.32 no.3
    • /
    • pp.399-406
    • /
    • 2009
  • A three-dimensional panel system, which was offered as a new method for construction in Jordan using relatively high strength modular panels for walls and ceilings, is investigated in this paper. The panel consists of two steel meshes on both sides of an expanded polystyrene core and connected together with a truss wire to provide a 3D system. The top face of the ceiling panel was pored with regular concrete mix, while the bottom face and both faces of the wall panels were cast by shotcreting (dry process). To investigate the structural performance of this system, an extensive experimental testing program for ceiling and wall panels subjected to static and dynamic loadings was conducted. The load-deflection curves were obtained for beam and shear wall elements and wall elements under transverse and axial loads, respectively. Static and dynamic analyses were conducted, and the performance of the proposed structural system was evaluated and compared with a typical three dimensional reinforced concrete frame system for buildings of the same floor areas and number of floors. Compressive strength capacity of a ceiling panel is determined for gravity loads, while flexural capacity is determined under the effect of wind and seismic loading. It was found that, the strength and serviceability requirements could be easily satisfied for buildings constructed using the three-dimensional panel system. The 3D panel system is superior to that of conventional frame system in its dynamic performance, due to its high stiffness to mass ratio.

Seismic behavior of steel frames with replaceable reinforced concrete wall panels

  • Wu, Hanheng;Zhou, Tianhua;Liao, Fangfang;Lv, Jing
    • Steel and Composite Structures
    • /
    • v.22 no.5
    • /
    • pp.1055-1071
    • /
    • 2016
  • The paper presents an innovative steel moment frame with the replaceable reinforced concrete wall panel (SRW) structural system, in which the replaceable concrete wall can play a role to increase the overall lateral stiffness of the frame system. Two full scale specimens composed of the steel frames and the replaceable reinforced concrete wall panels were tested under the cyclic horizontal load. The failure mode, load-displacement response, deformability, and the energy dissipation capacity of SRW specimens were investigated. Test results show that the two-stage failure mode is characterized by the sequential failure process of the replaceable RC wall panel and the steel moment frame. It can be found that the replaceable RC wall panels damage at the lateral drift ratio greater than 0.5%. After the replacement of a new RC wall panel, the new specimen maintained the similar capacity of resisting lateral load as the previous one. The decrease of the bearing capacity was presented between the two stages because of the connection failure on the top of the replaceable RC wall panel. With the increase of the lateral drift, the percentage of the lateral force and the overturning moment resisted by the wall panel decreased for the reason of the reduction of its lateral stiffness. After the failure of the wall panel, the steel moment frame shared almost all the lateral force and the overturning moment.

Evaluation criteria for filling performance of high-flowing concrete using steel-concrete panel

  • Dong Kyu Lee;Jae Seon Kim;Myoung Sung Choi
    • Advances in concrete construction
    • /
    • v.16 no.5
    • /
    • pp.231-241
    • /
    • 2023
  • The purpose of this study was to evaluate the practical application of high-flowing concrete for a steel-concrete panel (SCP) module for a liquefied natural gas (LNG) storage tank. We evaluated the physical properties and filling performance of the developed concrete for the SCP module. First, slump tests were performed to evaluate the performance of the proposed standards for the filling tests. All the concrete mixes showed satisfactory performance. Based on the results of the previous study, the reliability of the required time measured using the T500 test and the rheometer results measured before and after pumping was 0.94, indicating that segregation and blocking should not occur. L-box and U-box tests were conducted before and after pumping. All the recommended standards showed satisfactory performance. The SCP structural module for LNG storage tanks was fabricated to a full scale to evaluate its practical application at the final site. Satisfactory filling performance was confirmed for all the specimens.

An Experiment Study on the Structural Behavior of Full-scale Subassemblage Subjected to Monotonic Loads in Precast Concrete Panel Structres (일방향 단순 횡하중을 받는 P.C판 조립식구조 실물 Subassemblage의 구조거동에 대한 실험적 연구)

  • Youn, Jae-Jin;Chung, Lan;Lee, Soo-Gon
    • Magazine of the Korea Concrete Institute
    • /
    • v.3 no.2
    • /
    • pp.133-145
    • /
    • 1991
  • The essential difference between precast concrete structures and in situ concrete structures lies in the precast concrete panel structres, it is necessary to understand the bahavior of joints and their implications regarding overall structural behavior. Form such a point of view, this experimental study observes the components and joint behavior under the stress states expected of precast concrete panel structures subjected to lateral loads. 2 full-scale subassemblages were fabricated and tested. The test results show that the characteristics of horizontsl joints and wall coupling beams mainly govern the whole hahavior of P.C. structres.

Thermal Properties of the Cement Extruding Panel with Waste concrete Powder (폐 콘크리트 미분을 혼입한 시멘트 압출성형 패널의 열적특성)

  • Choi, Duck-Jin;Hong, Sung-Rog;Lee, Min-Jae;Kim, Jang-Yup;Kim, Jin-Man
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.283-286
    • /
    • 2012
  • According to increase of the waste concrete occurrence, recycling has being important more and more. This study is to recycle the waste concrete powder, which is occurred in dry-process during recycling of construction waste. We have tried the waste concrete powder to apply as the replacement of the silica powder in cement extruding product. As a result, it is satisfied that the autoclave cured pannel of 50% replacement ratio of waste concrete powder staisty the level of the flexural strength of 14MPa stipulated by "KS F 4735 Extruding concrete panel" was the same thermal properties as base specimen.

  • PDF

Nonlinear Dynamic Analysis of Reinforced Concrete Containment Panel (철근콘크리트 격납 패널의 비선형 동적해석)

  • 박재근;김태훈;신현목
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.10a
    • /
    • pp.591-598
    • /
    • 2003
  • The purpose of this study is to investigate the seismic behavior of reinforced concrete Containment Panel subjected to earthquake motions. A computer program, named RCAHEST(Reinforced Concrete Analysis in Higher Evaluation System Technology), was used for the analysis of reinforced concrete structures. A 4-node flat shell element with drilling rotational stiffness is used for spatial discretization. The layered approach is used to discretize behavior of concrete and reinforcement through the thickness. Material nonlinearity is taken into account by comprising tensile, compressive and shear models of cracked concrete and a model of reinforcing steel. The smeared crack approach is incorporated. Solution of the equations of motion is obtained by numerical integration using Hither-Hughes-Taylor(HHT) algorithm. The proposed numerical method for the seismic analysis of reinforced concrete Containment panel is verified by comparison of analysis results with reliable experimental results.

  • PDF

Properties of Sandwich Panel Using Cellular Concrete (기포콘크리트를 사용한 샌드위치 패널의 특성)

  • Jung, Yong-Wook;Jang, Seck-Soo;Lee, Seung-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.845-848
    • /
    • 2006
  • This study sought to investigate the characteristics of cellular concrete, such as porosity, strength and density, according to the cell addition rate. Based on the result, it examined the application to a cellular concrete panel. Porosity was found to increase according to the cell addition rate, measuring continuous porosity of 42% and 47%, and total porosity of 61% and 66%. In terms of cell addition rate, measurements were 7% and 11% respectively. Compressive strength represented 5.0MPa, 3.8MPa and 2.8 MPa in terms of 7%, 9% and 11% respectively, decreasing 1 MPa of strength according to every 2% increase of cell addition rate. Density showed 0.55, 0.44 and 0.36 in terms of 7%, 9% and 11% respectively, decreasing 1.0 MPa according to every 2% increase of cell addition rate proportionally. In addition the sandwich panel of cellular concrete which was fabricated during this research was found to be relatively heavy and non-flammable with an excellent strength of 4.0 MPa. Compared with a light concrete panel, considering the compressive strength that accountsfor 10 MPa, it appeared relatively low in strength. However it would be excellent for application due to the light density of only 0.4 MPa.

  • PDF

Impact response of a novel flat steel-concrete-corrugated steel panel

  • Lu, Jingyi;Wang, Yonghui;Zhai, Ximei;Zhou, Hongyuan
    • Steel and Composite Structures
    • /
    • v.42 no.2
    • /
    • pp.277-288
    • /
    • 2022
  • A novel flat steel plate-concrete-corrugated steel plate (FS-C-CS) sandwich panel was proposed for resisting impact load. The failure mode, impact force and displacement response of the FS-C-CS panel under impact loading were studied via drop-weight impact tests. The combined global flexure and local indentation deformation mode of the FS-C-CS panel was observed, and three stages of impact process were identified. Moreover, the effects of corrugated plate height and steel plate thickness on the impact responses of the FS-C-CS panels were quantitatively analysed, and the impact resistant performance of the FS-C-CS panel was found to be generally improved on increasing corrugated plate height and thickness in terms of smaller deformation as well as larger impact force and post-peak mean force. The Finite Element (FE) model of the FS-C-CS panel under impact loading was established to predict its dynamic response and further reveal its failure mode and impact energy dissipation mechanism. The numerical results indicated that the concrete core and corrugated steel plate dissipated the majority of impact energy. In addition, employing end plates and high strength bolts as shear connectors could prevent the slip between steel plates and concrete core and assure the full composite action of the FS-C-CS panel.