• 제목/요약/키워드: concrete cracks

검색결과 1,310건 처리시간 0.029초

Shake-table study of plaster effects on the behavior of masonry-infilled steel frames

  • Baloevic, Goran;Radnic, Jure;Grgic, Nikola;Matesan, Domagoj
    • Steel and Composite Structures
    • /
    • 제23권2호
    • /
    • pp.195-204
    • /
    • 2017
  • The effects of plaster on the behavior of single-story single-bay masonry-infilled steel frames under in-plane base accelerations have been experimentally investigated by a shake-table. Tested structures were made in a 1/3 scale, with realistic material properties and construction methods. Steel frames with high and low flexural rigidity of beams and columns were considered. Each type of frame was tested with three variants of masonry: (i) non-plastered masonry; (ii) masonry infill with conventional plaster on both sides; and (iii) masonry infill with a polyvinyl chloride (PVC) net reinforced plaster on both sides. Masonry bricks were made of lightweight cellular concrete. Each frame was firstly successively exposed to horizontal base accelerations of an artificial accelerogram, and afterwards, to horizontal base accelerations of a real earthquake. Characteristic displacements, strains and cracks in the masonry were established for each applied excitation. It has been concluded that plaster strengthens the infill and prevents damages in it, which results in more favorable behavior and increased bearing capacity of plastered masonry-infilled frames compared to non-plastered masonry-infilled frames. The load-bearing contribution of the adopted PVC net in the plaster was not noticeable for the tested specimens, probably due to relative small cross section area of fibers in the net. Behavior of masonry-infilled steel frames significantly depends on frame stiffness. Strong frames have smaller displacements than weak frames, which reduces deformations and damages of an infill.

화재 후 터널구조물 시공재료의 역학적 특성변화 (Alteration of mechanical properties of tunnel structural members after a tunnel fire accident)

  • 장수호;최순욱;권종욱;김상환;배규진
    • 한국터널지하공간학회 논문집
    • /
    • 제9권2호
    • /
    • pp.157-169
    • /
    • 2007
  • 본 연구에서는 $300^{\circ}C$부터 $1,000^{\circ}C$까지 $100^{\circ}C$간격으로 터널구조물 시공재료별로 목표온도 조건에 따른 중량손실률 및 제반 역학적 특성변화를 측정하였다. 실험 결과, 재료의 역학적 특성이 선형적으로 급격히 저하되는 임계 온도는 $300^{\circ}C$정도이고, 급격한 재료 특성 저하 후 거시적인 파괴로 진전되는 임계 온도는 약 $600^{\circ}C$라는 것을 파악할 수 있었다. 터널구조물 시공재료별로 목표온도에 따른 역학적 특성변화 결과들을 회귀분석한 결과, Bolzmann함수로 최적 회귀함수를 도출할 수 있었다. 최종적으로 화재 시나리오에 따라 터널구조물에 사용되는 시공재료 내부의 온도분포를 쉽게 추정할 수 있으며, 그에 따른 압축강도 및 탄성계수와 같은 역학적 특성들의 저하 정도도 정량적으로 추정할 수 있는 도표를 제시하였다.

  • PDF

Perfobond Rib을 적용한 강-PSC 혼합구조 연결부의 거동 평가 (Behaviors of Joints with Perfobond Rib Shear Connectors in Steel-PSC Hybrid System)

  • 김상효;이찬구;윤지현;원정훈
    • 한국강구조학회 논문집
    • /
    • 제21권6호
    • /
    • pp.647-657
    • /
    • 2009
  • 본 연구는 강-프리스트레스 콘크리트(PSC) 혼합구조 보를 분절형 교량에 적용하기 위해 필수적으로 요구되는 이종 부재간의 연결에 대한 기초연구로써, 연결부 거동과 시공성을 향상시키기 위해 연결부 상․하부 플레이트에 perfobond rib 전단연결재를 설치한 강-PSC 연결부를 제안하였다. 제안된 연결부가 설치된 보 실험체들을 제작하여 하중재하실험을 통해 연결부의 성능을 확인한 결과, 모든 실험체에서 연결부의 파괴 없이 연결부 인접 PSC부에서 실험체의 파괴와 극한강도가 나타났다. 합성 작용에 의하여 실험체의 초기 강성은 우수한 것으로 나타났으며, 균열의 진전 형상도 전형적인 휨 균열 형상을 나타내었다. 또한, 기존 스터드를 적용한 실험체 이상의 강도를 얻을 수 있는 것으로 나타났다. 그러므로 제안된 연결부는 혼합구조 연결부에 효과적으로 적용 가능하다고 판단된다.

성능 평가에 근거한 LB-DECK의 설계 (Design of LB-DECK Based on Performance Evaluation)

  • 조규대;노병철;조현철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권4호
    • /
    • pp.99-106
    • /
    • 2011
  • 본 연구는 LB-DECK의 합성 전과 후 적절한 설계방법을 적용하기 위하여 PBD의 기초 개념에 근거하여 성능향상을 위한 연구를 수행하였다. 그 결과, 합성 전 폴리머 콘크리트를 활용함에 따라 휨 인장강도를 증가시켜 미세균열을 감소시킬 수 있으며, 심미적인 효과를 기대할 수 있고, 낮은 침투성으로 인하여 내구성을 향상시키고, 이에 따른 피복두께를 감소시킬 수 있을 것으로 평가되었다. 또한 합성 후 경험적 설계법을 적용한 LB-DECK 바닥판은 일반적인 바닥판보다 하중 저항능력이 우수하여 안전성이 증가되며, 강도설계법 적용시와 달리 지간이 증가되어도 철근배근방법과 철근배근량이 일정하기 때문에 시공성과 경제성을 동시에 확보할 것으로 기대된다.

철근 겹침이음 위치 부적정이 지하박스 슬래브 균열 발생에 미치는 영향 (Influence of Inadequate Rebar Lap Position on Crack of Underground Box Slab)

  • 최정열;장인수;정지승
    • 문화기술의 융합
    • /
    • 제6권4호
    • /
    • pp.685-692
    • /
    • 2020
  • 본 연구에서는 철근 겹침이음 위치가 부적정하게 시공된 사례를 바탕으로 콘크리트 구조기준에서 제시한 설치기준에 대하여 분석 및 고찰을 하였으며, 현행 구조기준에서 제시한 겹침이음에 대한 기준이 적정함을 해석적으로 입증하였다. 실제 종방향 균열이 발생된 지하 박스구조물 단면에 대한 철근 겹침이음부의 철근강도감소비 및 설계유효 모멘트를 산출하여 철근 겹침이음부의 균열 발생원인에 대하여 해석적으로 입증하였다. 연구결과, 최대 인장응력이 발생되는 지하 박스구조물 중앙부에 철근 겹침이음이 설치될 경우 철근 겹침이음부의 철근강도감소비는 82.8% 수준인 것으로 분석되었다. 따라서, 콘크리트 구조기준에서 정하고 있는 바와 같이 철근 겹침이음부의 위치는 최대 인장응력이 발생하는 지점을 피해야 하며, 부득이하게 겹침이음이 부적정한 위치에 설치되는 경우 본 연구에서 검토한 바와 같이 충분한 겹침이음길이를 확보하여야 하며, 구조물 단면력에 대하여 검토하여 충분한 안전율을 확보하는 것이 중장기적인 균열 제어 방법으로 적정할 것으로 검토되었다.

Standardization of composite connections for trapezoid web profiled steel sections

  • Saggaff, A.;Tahir, M.M.;Sulaiman, A.;Ngian, S.P.;Mirza, J.
    • Structural Engineering and Mechanics
    • /
    • 제55권4호
    • /
    • pp.765-784
    • /
    • 2015
  • Connections are usually designed either as pinned usually associated with simple construction or rigid normally is associated with continuous construction. However, the actual behaviour falls in between these two extreme cases. The use of partial strength or semi-rigid connections has been encouraged by Euro-code 3 and studies on semi-continuous construction have shown substantial savings in steel weight of the overall construction. Composite connections are proposed in this paper as partial or full strength connections. Standardized connection tables are developed based on checking on all possible failure modes as suggested by "component method" for beam-to-column composite connection on major axis. Four experimental tests were carried out to validate the proposed standardised connection table. The test results showed good agreement between experimental and theoretical values with the ratio in the range between 1.06 to 1.50. All tested specimens of the composite connections showed ductile type of failure with the formation of cracks occurred on concrete slab at maximum load. No failure occurred on the Trapezoidal Web Profiled Steel Section as beam and on the British Section as column.

Application of Antifungal CFB to Increase the Durability of Cement Mortar

  • Park, Jong-Myong;Park, Sung-Jin;Kim, Wha-Jung;Ghim, Sa-Youl
    • Journal of Microbiology and Biotechnology
    • /
    • 제22권7호
    • /
    • pp.1015-1020
    • /
    • 2012
  • Antifungal cement mortar or microbiological calcium carbonate precipitation on cement surface has been investigated as functional concrete research. However, these research concepts have never been fused with each other. In this study, we introduced the antifungal calcite-forming bacteria (CFB) Bacillus aryabhattai KNUC205, isolated from an urban tunnel (Daegu, South Korea). The major fungal deteriogens in urban tunnel, Cladosporium sphaerospermum KNUC253, was used as a sensitive fungal strain. B. aryabhattai KNUC205 showed $CaCO_3$ precipitation on B4 medium. Cracked cement mortar pastes were made and neutralized by modified methods. Subsequently, the mixture of B. aryabhattai KNUC205, conidiospore of C. sphaerospermum KNUC253, and B4 agar was applied to cement cracks and incubated at $18^{\circ}C$ for 16 days. B. aryabhattai KNUC205 showed fungal growth inhibition against C. sphaerospermum. Furthermore, B. aryabhattai KNUC205 showed crack remediation ability and water permeability reduction of cement mortar pastes. Taken together, these results suggest that the $CaCO_3$ precipitation and antifungal properties of B. aryabhattai KNUC205 could be used as an effective sealing or coating material that can also prevent deteriorative fungal growth. This study is the first application and evaluation research that incorporates calcite formation with antifungal capabilities of microorganisms for an environment-friendly and more effective protection of cement materials. In this research, the conception of microbial construction materials was expanded.

영상 처리 기법을 이용한 콘크리트 표면 균열의 폭 및 길이 추출 (A Length and Width Extraction of Concrete Surface Cracks using Image Processing Technique)

  • 허주용;김경란;임은경;안상호;김광백
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2006년도 춘계종합학술대회
    • /
    • pp.346-351
    • /
    • 2006
  • 본 논문은 콘크리트 표면 균열 영상에서 균열의 특징을 추출하기 위해, 영상 처리 기법을 적용하여 균열의 특징(길이, 폭, 방향)을 자동으로 추출 및 처리 할 수 있는 기법을 제안한다. 본 논문에서 적용된 영상 처리 기법으로는 균열 영상의 빛을 보정하기 위하여 모폴로지 기법인 채움(Closing)기법을 적용한다. 균열의 경계를 명확히 추출하기 위하여 고주파 강화 필터링을 적용한 후, 8가지 색상(검정, 빨강, 파랑, 초록, 노랑, 자주, 주황, 하늘)으로 명암 값을 분류하고 그 중 빈도수가 가장 높은 색상을 가진 명암 값을 제거한 후에 추출한 영상을 이진화한다. 이진화된 영상에서 콘크리트 표면 균열의 실거리 측정을 위한 임의의 선을 제거하기 위하여 위치 히스토그램을 적용하여 임의의 선을 제거한다. 임의의 선이 제거된 균열 영상에서 $5\times5$ 마스크를 적용하여 균열을 확대시키고, 3차례에 걸쳐 잡음 제거연산을 수행하여 균열의 후보 영역을 선택한 후, 후보 영역으로부터 특정 균열들을 추출한다. 추출된 특정 균열을 모폴로지 기법인 제거(Opening) 연산을 수행하여 균열의 특징이 일정하게 유지되게 하고 미세하게 끊어진 부분을 보정하여 균열의 특징(길이, 방향, 폭)을 측정한다. 실제 콘크리트 표면 균열영상을 대상으로 실험한 결과, 특정 균열이 효율적으로 추출되었고, 특정 균열의 길이, 방향, 폭의 등이 정확히 추출 및 계산되었다.

  • PDF

대직경 스터드 전단연결재의 피로거동 (Fatigue Behavior of Large Stud Shear Connectors)

  • 심창수;이필구;김현호;윤태양
    • 한국강구조학회 논문집
    • /
    • 제15권6호통권67호
    • /
    • pp.621-628
    • /
    • 2003
  • 스터드 전단연결재는 강합성 구조에서 가장 많이 사용되는 전단연결재인데 현재는 주로 22mm 직경까지를 사용하고있다. 시방규정에서 제시하고 있는 적용범위의 확대를 위해서 25mm 이상의 대직경 스터드 전단연결재에 대한 연구가 필요하다. 현재의 전단연결재 설계 범위를 넘어서는 대직경 스터드 전단연결에 대한 push-out 실험을 통해서 피로거동을 검토하고 기존 설계식과의 비교를 수행하였다. 25, 27, 30mm 직경의 스터드에 대한 전단실험을 통해서 탄성영역에서의 전단강성을 평가하여 정적 실험결과와 비교하였다. 피로 하중을 받는 대직경 스터드의 피로거동을 잔류 슬립과 하중-슬립 곡선으로 설명하였다. 용접부 피로균열의 발생시점을 변위진폭으로부터 유추하는 것이 타당한 것으로 밝혀졌다. 기존 시방규정의 S-N 곡선과의 비교를 통해서 대직경 스터드 전단연결재의 피로 수명은 현재의 설계 규정을 준용해도 무방한 것으로 나타났다.

Effect of diameter of MWCNT reinforcements on the mechanical properties of cement composites

  • Zaheer, Mohd Moonis;Jafri, Mohd Shamsuddin;Sharma, Ravi
    • Advances in concrete construction
    • /
    • 제8권3호
    • /
    • pp.207-215
    • /
    • 2019
  • Application of nanotechnology can be used to tailor made cementitious composites owing to small dimension and physical behaviour of resulting hydration products. Because of high aspect ratio and extremely high strength, carbon nanotubes (CNTs) are perfect reinforcing materials. Hence, there is a great prospect to use CNTs in developing new generation cementitious materials. In the present paper, a parametric study has been conducted on cementitious composites reinforced by two types of multi walled carbon nanotubes (MWCNTs) designated as Type I CNT (10-20 nm outer dia.) and Type II CNT (30-50 nm outer dia.) with various concentrations ranging from 0.1% to 0.5% by weight of cement. To evaluate important properties such as flexural strength, strain to failure, elastic modulus and modulus of toughness of the CNT admixed specimens at different curing periods, flexural bending tests were performed. Results show that composites with Type II CNTs gave more strength as compared to Type I CNTs. The highest increase in strength (flexural and compressive) is of the order of 22% and 33%, respectively, compared to control samples. Modulus of toughness at 28 days showed highest improvement of 265% for Type II 0.3% CNT composites. It is obvious that an optimum percentage of CNT could exists for composites to achieve suitable reinforcement behaviour and desired strength properties. Based on the parametric study, a tentative optimum CNT concentration (0.3% by weight of cement) has been proposed. Scanning electron microscope image shows perfect crack bridging mechanism; several of the CNTs were shown to act as crack arrestors across fine cracks along with some CNTs breakage.