• 제목/요약/키워드: concrete bridge

검색결과 2,182건 처리시간 0.032초

Damage inspection and performance evaluation of Jilin highway double-curved arch concrete bridge in China

  • Naser, Ali Fadhil;Zonglin, Wang
    • Structural Engineering and Mechanics
    • /
    • 제39권4호
    • /
    • pp.521-539
    • /
    • 2011
  • Jilin highway concrete bridge is located in the center of Jilin City, which is positioned in the middle part in Jilin Province in the east north of China. This bridge crosses the Songhua River and connects the north and the south of Jilin City. The main purpose of damages inspection of the bridge components is to ensure the safety of a bridge and to identify any maintenance, repair, or strengthening which that need to be carried out. The damages that occur in reinforced concrete bridges include different types of cracks, scalling and spalling of concrete, corrosion of steel reinforcement, deformation, excessive deflection, and stain. The main objectives of this study are to inspect the appearance of Jilin highway concrete bridge and describe all the damages in the bridge structural members, and to evaluate the structural performance of the bridge structure under dead and live loads. The tests adopted in this study are: (a) the depth of concrete carbonation test, (b) compressive strength of concrete test, (c) corrosion of steel test, (d) static load test, and (e) dynamic load test. According to the damages inspection of the bridge structure appearance, most components of the bridge are in good conditions with the exception arch waves, spandrel arch, deck pavement of new arch bridge, and corbel of simply supported bridge which suffer from serious damages. Load tests results show that the deflection, strain, and cracks development satisfy the requirements of the standards.

LB-DECK를 이용한 철근콘크리트바닥판의 펀칭전단강도 (Punching Shear Strength of Reinforced Concrete Bridge Decks with LB-DECK)

  • 윤석구;이재홍;조선규;정재동;원용석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.390-393
    • /
    • 2006
  • LB-DECK is used for both of permanent formwork and structural component with cast-in place concrete of concrete bridge decks. Current Korean design code recommends that concrete bridge deck with precast concrete panels have to be designed only using conventional flexural design method and does not allow the empirical design method which is based on punching shear strength of bridge deck. This paper present experimental test results of punching shear strength of concrete bridge decks with LB-DECKs. Six full-scaled concrete bridge decks, which are designed with the empirical design method, are fabricated with variation of girder spacings. Test results are presented in the paper and compared with the code predictions of ACI 318, CEB-FIP MC90. Based on the test results, it is proposed that LB-DECK is suitable to apply the empirical design method for concrete bridge decks.

  • PDF

Structural performance assessment of deteriorated reinforced concrete bridge piers

  • Kim, T.H.
    • Computers and Concrete
    • /
    • 제14권4호
    • /
    • pp.387-403
    • /
    • 2014
  • The aim of this study is to assess the structural performance of deteriorated reinforced concrete bridge piers, and to provide method for developing improved evaluation method. For a deteriorated bridge piers, once the cover spalls off and bond between the reinforcement and concrete has been lost, compressed reinforcements are likely to buckle. By using a sophisticated nonlinear finite element analysis program, the accuracy and objectivity of the assessment process can be enhanced. A computer program, RCAHEST (Reinforced Concrete Analysis in Higher Evaluation System Technology), is used to analyze reinforced concrete structures. Material nonlinearity is taken into account by comprising tensile, compressive and shear models of cracked concrete and a model of reinforcing steel. Advanced deteriorated material models are developed to predict behaviors of deteriorated reinforced concrete. The proposed numerical method for the structural performance assessment of deteriorated reinforced concrete bridge piers is verified by comparing it with reliable experimental results. Additionally, the studies and discussions presented in this investigation provide an insight into the key behavioral aspects of deteriorated reinforced concrete bridge piers.

GFRP 근 보강 콘크리트 교량 바닥판의 설계지배인자 (Governing Design Factors of GFRP-Reinforced Concrete Bridge Deck)

  • 조정래;박영환;박성용;조근희;김성태
    • 한국안전학회지
    • /
    • 제30권6호
    • /
    • pp.70-77
    • /
    • 2015
  • In this study, the governing design factors of GFRP-reinforced concrete bridge deck are analyzed for typical bridges in Korea. The adopted bridge deck is a cast-in-situ concrete bridge deck for the prestressed concrete girder bridge with dimensions of 240 mm thickness and 2.75 m span length from center-to-center of supporting girders. The selected design variables are the diameters of GFRP rebar, spacings of GFRP rebars and concrete cover thicknesses, Considering the absence of the specification relating GFRP rebar in Korea, AASHTO specification is used to design the GFRP-reinforced concrete bridge deck. The GFRP-reinforced concrete bridge deck is proved to be governed by the criteria about serviceability, especially maximum crack width, while steel reinforced concrete bridge deck is governed by the criteria on ultimate limit state. In addition, GFRP rebars with diameter of 16 mm ~ 19 mm should be used for the main transverse direction of decks to assure appropriate rebar spacings.

Traffic-induced vibrations at the wet joint during the widening of concrete bridges and non-interruption traffic control strategies

  • Junyong Zhou;Zunian Zhou;Liwen Zhang;Junping Zhang;Xuefei Shi
    • Computers and Concrete
    • /
    • 제32권4호
    • /
    • pp.411-423
    • /
    • 2023
  • The rapid development of road transport has increased the number of bridges that require widening. A critical issue in the construction of bridge widening is the influence of vibrations of the old bridge on the casting of wet joint concrete between the old and new bridges owing to the running traffic. Typically, the bridge is closed to traffic during the pouring of wet joint concrete, which negatively affects the existing transportation network. In this study, a newly developed microscopic traffic load modeling approach and the vehicle-bridge interaction theory are incorporated to develop a refined numerical framework for the analysis of random traffic-bridge coupled dynamics. This framework was used to investigate traffic-induced vibrations at the wet joint of a widened bridge. Based on an experimental study on the vibration resistance of wet joint concrete, traffic control strategies were proposed to ensure the construction performance of cast-in-site wet joint concrete under random traffic without interruption. The results show that the vibration displacement and frequency of the old bridge, estimated by the proposed framework, were comparable with those obtained from field measurements. Based on the target peak particle velocity and vibration amplitude of the wet joint concrete, it was found that traffic control measures, such as limiting vehicle gross weight and limiting traffic volume by closing an additional traffic lane, could ensure the construction performance of the wet joint concrete.

고성능 콘크리트 교면포장의 최적 두께 평가 (Evaluation of Optimum Thickness of High Performance Concrete Bridge Deck Pavement)

  • 박해균;김지원;전상은;이명섭;원종필
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.318-321
    • /
    • 2006
  • The objective of this study is to evaluate the optimum thickness of High Performance Concrete bridge deck pavement. The application of High Performance Concrete bridge deck pavement with micro-silica was introduced to north America in the early 1980's. In order to decide the optimum thickness of High Performance Concrete bridge deck pavement, we conducted Finite Element Method analysis with Incheon Grand Bridge constructed by SAMSUNG E&C. From the FEM results, a thickness of five centimeters of High Performance Concrete bridge deck pavement with micro-silica is considered as a resonable value compared with the conventional asphalt bridge deck pavement.

  • PDF

Experimental and numerical study on shear studs connecting steel girder and precast concrete deck

  • Xia, Ye;Chen, Limu;Ma, Haiying;Su, Dan
    • Structural Engineering and Mechanics
    • /
    • 제71권4호
    • /
    • pp.433-444
    • /
    • 2019
  • Shear studs are often used to connect steel girders and concrete deck to form a composite bridge system. The application of precast concrete deck to steel-concrete composite bridges can improve the strength of decks and reduce the shrinkage and creep effect on the long-term behavior of structures. How to ensure the connection between steel girders and concrete deck directly influences the composite behavior between steel girder and precast concrete deck as well as the behavior of the structure system. Compared with traditional multi-I girder systems, a twin-I girder composite bridge system is more simplified but may lead to additional requirements on the shear studs connecting steel girders and decks due to the larger girder spacing. Up to date, only very limited quantity of researches has been conducted regarding the behavior of shear studs on twin-I girder bridge systems. One convenient way for steel composite bridge system is to cast concrete deck in place with shear studs uniformly-distributed along the span direction. For steel composite bridge system using precast concrete deck, voids are included in the precast concrete deck segments, and they are casted with cast-in-place concrete after the concrete segments are erected. In this paper, several sets of push-out tests are conducted, which are used to investigate the heavier of shear studs within the voids in the precast concrete deck. The test data are analyzed and compared with those from finite element models. A simplified shear stud model is proposed using a beam element instead of solid elements. It is used in the finite element model analyses of the twin-I girder composite bridge system to relieve the computational efforts of the shear studs. Additionally, a parametric study is developed to find the effects of void size, void spacing, and shear stud diameter and spacing. Finally, the recommendations are given for the design of precast deck using void for twin I-girder bridge systems.

고성능 콘크리트를 활용한 교량 교면포장 기술 (Bridge Deck Overlay Technology Using High Performance Concrete)

  • 박해균;원종필
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.1113-1116
    • /
    • 2008
  • 실리카퓸, 플라이애쉬, 고로슬래등 미분말 혼화재가 포함된 고성능 콘크리트(High Performance Concrete) 교량 바닥판 보호공법은 1980년 초부터 북미를 중심으로 사용되어 왔다. 본 보고서에서는 교량 바닥판 보호를 위한 고성능 콘크리트 적용사례와 고성능 콘크리트를 이용한 두 가지 공법(고성능 콘크리트 교면포장공법, 노출 바닥판 공법)에 대해 소개한다. 위 두 공법은 이미 북미에서 많은 실적을 보유하고 있으며 특히, 실리카퓸과 PVA섬유가 포함된 고성능 콘크리트 교면포장공법은 국내에서도 성공적으로 적용되고 있다. 따라서 본고에서는 기존 아스팔트 재료를 대체할 수 있고, 최근 국내에서도 그 적용성에 대한 관심과 실 시공이 이루어지고 있는 고성능 콘크리트를 이용한 교면포장 (Overlay) 공법 및 노출 바닥판(Full depth) 공법에 대해 소개하고자 한다.

  • PDF

Analysis of effects of shrinkage of concrete added to widen RC girder bridge

  • Madaj, Arkadiusz;Siekierski, Wojciech
    • Computers and Concrete
    • /
    • 제23권5호
    • /
    • pp.329-334
    • /
    • 2019
  • Traffic flow capacity of some old road bridges is insufficient due to limited deck width. In such cases bridge deck widening is a common solution. For multi-girder reinforced concrete (RC) bridges it is possible to add steel-concrete composite girders as the new outermost girders. The deck widening may be combined with bridge strengthening thanks to thickening of the existing deck slab. Joint action of the existing and the added parts of such bridge span must be ensured. It refers especially to the horizontal plane at the interface of the existing slab and the added concrete layer as well as to the vertical planes at the external surfaces of the initially outermost girders where the added girders are connected to the existing bridge span. Since the distribution of the added concrete is non-uniform in the span cross-section the structure is particularly sensitive to the added concrete shrinkage. The shrinkage induces shear forces in the aforementioned planes. Widening of a 12 m long RC multi-girder bridge span is numerically analysed to assess the influence of the added concrete shrinkage. The analysis results show that: a) in the vertical plane of the connection of the added and the existing deck slab the longitudinal shear due to the shrinkage of the added concrete is comparable with the effect of live load, b) it is necessary to provide appropriate longitudinal reinforcement in the deck slab over the added girders due to tension induced by the shrinkage of the added concrete.

Study on seismic strengthening of railway bridge pier with CFRP and concrete jackets

  • Ding, Mingbo;Chen, Xingchong;Zhang, Xiyin;Liu, Zhengnan;Lu, Jinghua
    • Earthquakes and Structures
    • /
    • 제15권3호
    • /
    • pp.275-283
    • /
    • 2018
  • Seismic strengthening is essential for existing bridge piers which are deficient to resist the earthquake. The concrete and CFRP jackets with a bottom-anchoring method are used to strengthen railway bridge piers with low reinforcement ratio. Quasi-static tests of scaled down model piers are performed to evaluate the seismic performance of the original and strengthened bridge pier. The fracture characteristics indicate that the vulnerable position of the railway bridge pier with low reinforcement ratio during earthquake is the pier-footing region and shows flexural failure mode. The force-displacement relationships show that the two strengthening techniques using CFRP and concrete jackets can both provide a significant improvement in load-carrying capacity for railway bridge piers with low reinforcement ratio. It is clear that the bottom-anchoring method by using planted steel bars can guarantee the CFRP and concrete jackets to work jointly with original concrete piers Furthermore, it can be found that the use of CFRP jacket offers advantages over concrete jacket in improving the energy dissipation capacity under lateral cyclic loading. Therefore, the seismic strengthening techniques by the use of CFRP and concrete jackets provide alternative choices for the large numbers of existing railway bridge piers with low reinforcement ratio in China.