• Title/Summary/Keyword: concentric arrangement winding

Search Result 4, Processing Time 0.015 seconds

Comparison of Reciprocal and Concentric Winding Arrangement of HTS Transformer (고온초전도 변압기의 교호 배치 권선과 동심형 배치 권선의 비교)

  • Kim, Sung-Hoon;Kim, Woo-Seok;Lee, Sang-Jin;Park, Kyeong-Dal;Joo, Hyeong-Gil;Hong, Gye-Won;Han, Jin-Ho;Hahn, Song-yop;Park, Chan-Bae
    • Progress in Superconductivity
    • /
    • v.5 no.1
    • /
    • pp.61-64
    • /
    • 2003
  • In HTS transformer with double pancake windings, the perpendicular component of leakage magnetic flux density ($B_{r}$ ) applied to HTS tapes of double pancake windings of HTS transformer acts as a cause to decrease the critical current in HTS tape. So, in this paper, HTS transformer with reciprocal arrangement winding is designed. And in order to investigate the$ B_{r}$ applied to HTS windings, the 2-D non-linear electromagnetic analysis of HTS transformer is performed by using the OPERA 2D. The maximum $B_{r}$ applied to winding of HTS transformer is 0.112 T and the characteristics of HTS transformer were also obtained. But in this type of winding arrangement, reciprocal arrangement, the generated ac-loss to the HTS windings is very high because of the applied $B_{r}$ to HTS windings. Therefore, in order to reduce the generated ac-loss to the HTS windings, the new design of HTS transformer with concentric winding arrangement is presented in this paper and the 2-D non-linear electromagnetic analysis and the ac-loss for HTS transformer with the concentric winding arrangement is also carried out.

  • PDF

Fabrication and Characteristic Tests of a 1 MVA Single Phase HTS Transformer with Concentrically Arranged Windings

  • Kim, S.H.;Kim, W.S.;Choi, K.D.;Joo, H.G.;Hong, G.W.;Han, J.H.;Lee, H.G.;Park, J.H.;Song, H.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.4
    • /
    • pp.37-40
    • /
    • 2004
  • A 1 MV A single phase high temperature superconducting (HTS) transformer was manufactured and tested. The rated voltages of primary and secondary of the HTS transformer are 22.9 kV and 6.6 kV respectively. BSCCO-2223 HTS tape was used for HTS windings of 1 MV A HTS transformer. In order to reduce AC loss generated in the HTS winding, the type of concentric arrangement winding was adopted to a 1 MV A HTS transformer. Single HTS tape for primary windings and 4 parallel HTS tapes for secondary windings were used considering the each rated current of the HTS transformer. A core of HTS transformer was fabricated as a shell type core made of laminated silicon steel plate. And a GFRP cryostat with a room temperature bore was also manufactured. The characteristic tests of 1 MV A HTS transformer were performed such as no load test, short circuit test and several insulation tests at 65 K using sub-cooled liquid nitrogen. From the results of tests, the validity of design of HTS transformer was ascertained.