• 제목/요약/키워드: concentration measuring test

검색결과 214건 처리시간 0.024초

3D-ESPI 시스템을 이용하여 결정된 응력집중계수가 피로수명에 미치는 영향에 관한 연구

  • 김성찬
    • 선박안전
    • /
    • 제12권
    • /
    • pp.36-43
    • /
    • 2003
  • Fatigue life estimation by the theoretical stress concentration factors are, in general, considerably different from test results. And in calculating stress concentration factor, it is very difficult to consider actual geometry and material property which are the notch shapes, imperfections or defects of materials such as porosities inclusions and casting defects, etc. Therefore, the paper deals with the experimental method to find out the more exact stress concentration factors by measuring the strain distributions on each specimen by 3D-ESPI(Electronic Speckle Pattern Interferometry) System. Then the fatigue lives are compared between theoretical calculations using stress concentration factors determined by 3D-ESPI system and fatigue test results

  • PDF

가스보일러 배기통 이탈에 의한 CO가스 누출확산 실험 및 수치해석 (EXPERIMENTAL AND COMPUTATIONAL PREDICTION OF CONCENTRATION OF CARBON MONOXIDE GAS RELEASED FROM EXHAUST TUBE OF GAS BOILER)

  • 강승규;최경석;윤준용
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.172-175
    • /
    • 2008
  • In the last five years, 45 people died and 104 were wounded because of carbon monoxide poisoning accident. CO poisoning accident is higher than any other gas accident in the rate of deaths/incidents. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread of CO gas released from leakage hole of exhaust tube was analyzed by computational flow modeling and concentration measuring test. CO gas leaked form exhaust tube in a building was highest concentrated near the ceiling and formed the circular currents along the walls. Through these experiments and simulation, the reasonable installation location of CO alarm was made certain and suggested.

  • PDF

연소로 내 2차공기의 주유동 수직방향 선회분사로 인한 선회류가 스월수에 따른 가스 체류시간과 혼합 특성에 미치는 영향 (Effect of Swirling Flow by Normal Injection of Secondary Air on the Gas Residence Time and Mixing Characteristics in a Combustor)

  • 박상욱;전병일;류태우;황정호
    • 대한기계학회논문집B
    • /
    • 제30권1호
    • /
    • pp.48-56
    • /
    • 2006
  • We investigated gas residence time and mixing characteristics due to various swirl numbers generated by normal injection of secondary air to a lab-scale cylinderical combustor. The residence time was estimated by measuring the temporal pressure difference which was caused by deposition of test particles on a filter media after the injection by a syringe. The mixing characteristics were evaluated by standard deviation value of test gas concentration at different measuring points. The test gas concentration was detected by a gas analyzer. The swirl number of $20{\sim}30$ for ${\theta}=5^{\circ}$ caused long residence time enough to improve mixing characteristics. Numerical calculations were also carried out to understand physical meanings of the experimental results.

흡수용액의 In-line 농도측정을 위한 기초연구 (A Preliminary Study on the In-line Concentration Measurement of Absorbent Solution)

  • 민병혁;황덕용;정시영;구기갑
    • 설비공학논문집
    • /
    • 제15권2호
    • /
    • pp.152-158
    • /
    • 2003
  • Titration method is one of the widely used methods for the concentration measurement of absorbent ammonia/water. However, this method is inconvenient because the solution should be extracted for the measurement. Moreover, significant error can be introduced by the evaporation of ammonia during the sampling and measuring procedure. In this study a reliable in-line concentration measurement method was proposed. To prove the validity of the concept, a measuring apparatus was designed, built, and tested with water. It is found that the location of flow inlet and exit is important in the measurement accuracy. The flow inlet and exit located in the middle of the test cell showed the best result. By the error analysis, it is expected that the ammonia concentration can be measured within the error of $\pm$0.18% assuming the error of 0.1 K in temperature measurement and 0.1 g in weight measurement.

3D-ESPI 시스템을 이용하여 결정된 응력집중계수가 피로수명에 미치는 영향에 관한 연구 (A Study on the Effect of Stress Concentration Factor Determined by 3D-ESPI System on the Fatigue Life)

  • 김경수;심천식
    • 한국해양공학회지
    • /
    • 제16권1호
    • /
    • pp.46-51
    • /
    • 2002
  • Fatigue life estimation by the theoretical stress concentration factors are, in general, considerably different from test results. And in calculating stress concentration factor, it is very difficult to consider actual geometry and material property which are the notch shapes, imperfections or defects of materials such as porosities inclusions and casting defects, etc. Therefore, the paper deals with the experimental method to find out the more exact stress concentration factors by measuring the strain distributions on each specimen by 3D-ESPI(Electronic Speckle Pattern Interferometry) System. Then the fatigue lives are compared between theoretical calculations using stress concentration factors determined by 3D-ESPI system and fatigue test results.

대체냉매 R-407C와 R-410A를 사용하는 냉동시스템의 오일농도 예측에 관한 연구 (A study on prediction of oil concentration in the R-407C and R-410A refrigeration system)

  • 이종문;김창년;박영무
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.384-390
    • /
    • 1999
  • A vibrating U-Tube decimeter has been evaluated as a sensor for measuring the concentration of oil in the liquid line of a refrigeration system. Calibration and performance tests were conducted under simulated liquid-line conditions for R-407C/POE oil and R-410A/POE oil mixtures in oil concentration from 0 to 15 weight percent. Test temperatures ranged from 20 to 5$0^{\circ}C$. As a result of test, oil concentration correlations are presented in terms of specific gravity at each constant temperature. These equations enable to predict the oil concentration without any extraction of the mixture, and can be applied for R-407C/POE oil and R-410A/POE oil mixtures.

  • PDF

할론대체물질의 새로운 불꽃소화농도 측정장치에 관한 연구 (A Study on the Measurement of Flame Extinguishing Concentration of Halon Alternatives by New Test Equipment)

  • 김재덕;임종성;이윤우;이윤용
    • 한국화재소방학회논문지
    • /
    • 제8권1호
    • /
    • pp.3-8
    • /
    • 1994
  • A new test system was established to measure the flame extinguishing concentration of Halon alternatives. The main characteristic of this system is to use the solid paraffin with a wick instead of liquid fuel, such as n-Heptane. Our results showed that the extinguishing concentration of compounds was lower than that of other existing data, but the trend was consistent with others. The flame extinguishing concentration of all tested compounds were not almost effected by gas flow velocity. The system produces good reliable data with a minimum error for measuring the flame extinguishing concentration. Therefore our new system can be utilized as a standard equipment to evaluate Halon alternatives.

  • PDF

랩스케일 정삼투실험을 통한 정삼투막의 수투과도 평가 (Evaluation of water permeability of forward osmosis membranes using osmotically driven membrane test)

  • 이준서;김수한
    • 상하수도학회지
    • /
    • 제30권4호
    • /
    • pp.417-425
    • /
    • 2016
  • Desalination is a key technology to overcome water shortage problem in a near future. High energy consumption is an Achilles' heel in desalination technology. Osmotically driven membrane processes like forward osmosis(FO) was introduced to address this energy issue. Characterizing membrane properties such as water permeability(A), salt permeability(B), and the resistance to salt diffusion within the support layer($K_{ICP}$) are very important to predict the performance of scaled-up FO processes. Currently, most of researches reported that the water permeability of FO membrane was measured by reverse osmosis(RO) type test. Permeating direction of RO and FO are different and RO test needs hydraulic pressure so that several problems can be occurred(i.e. membrane deformation, compaction and effect of concentration polarization). This study focuses on measuring water permeability of FO membrane by FO type test results in various experimental conditions. A statistical approach was developed to evaluate the three FO membrane properties(A, B, and $K_{ICP}$) and it predicted test result by the internal and external concentration polarization model.

Design of User Concentration Classification Model by EEG Analysis Based on Visual SCPT

  • Park, Jin Hyeok;Kang, Seok Hwan;Lee, Byung Mun;Kang, Un Gu;Lee, Young Ho
    • 한국컴퓨터정보학회논문지
    • /
    • 제23권11호
    • /
    • pp.129-135
    • /
    • 2018
  • In this study, we designed a model that can measure the level of user's concentration by measuring and analyzing EEG data of the subjects who are performing Continuous Performance Test based on visual stimulus. This study focused on alpha and beta waves, which are closely related to concentration in various brain waves. There are a lot of research and services to enhance not only concentration but also brain activity. However, there are formidable barriers to ordinary people for using routinely because of high cost and complex procedures. Therefore, this study designed the model using the portable EEG measurement device with reasonable cost and Visual Continuous Performance Test which we developed as a simplified version of the existing CPT. This study aims to measure the concentration level of the subject objectively through simple and affordable way, EEG analysis. Concentration is also closely related to various brain diseases such as dementia, depression, and ADHD. Therefore, we believe that our proposed model can be useful not only for improving concentration but also brain disease prediction and monitoring research. In addition, the combination of this model and the Brain Computer Interface technology can create greater synergy in various fields.

서방출형 이산화염소 가스 젤팩의 미생물 살균 시험 (Sterilization Test of Microorganisms of Slow-released ClO2 Gas Gel-Pack)

  • 이경행;김홍길
    • 한국식품영양학회지
    • /
    • 제31권2호
    • /
    • pp.308-312
    • /
    • 2018
  • Even though chlorine dioxide ($ClO_2$) is utilized in a pre-treatment due to its effective sterilizing activity for microorganisms and its safety for food, it has a limitation in maintaining freshness of the food product. In this study, a low-concentration $ClO_2$ gas was produced in a packaging form of air-permeable gel pack so that it could be released continuously over several days. The amount of $ClO_2$ gas emission and microbial inactivation effect against foodborne pathogens were measured during the release of $ClO_2$ gas. As a result of measuring the change of color in order to confirm whether the chlorine dioxide gas was eluted in the form of a sustained release, the yellowness was significantly higher at higher gel pack concentration and higher value during storage periods. The slow-released $ClO_2$ gel-pack showed clear inactivation effect against Escherichia coli and Staphylococcus aureus with 99.9% inactivation efficiency. As a result of measuring the sterilization effect of Listeria monocytogenes by the concentration of chlorine dioxide gas, the sterilization effect was increased as the concentration was increased. Therefore, the slow-released $ClO_2$ gel-pack is feasible to apply for industry usages.