• 제목/요약/키워드: computer tomography

검색결과 415건 처리시간 0.033초

충돌 제트 분석을 위한 3차원 토모그래피 기법 개발 (Development of Three-dimensional Tomography Technique for Analysis of Impinging Jet)

  • 김용재;안성수;고한서
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 추계학술대회 논문집
    • /
    • pp.34-35
    • /
    • 2004
  • Three dimensional density distributions of impinging and eccentric flames have been investigated by digital speckle tomography. The flames have been ignited by a mixture of butane and air from a circular nozzle and impinged against a plate located at the upper side of the burner exit. For comparison with experimental data, computer synthesized phantoms of impinging and eccentric flames have been reconstructed by a developed three-dimensional multiplicative algebraic reconstruction technique (MART). The advanced reconstruction in the stagnation flow region involved the sharp change of the flow direction and pressure gradient has been developed using a cross-correlation method and new scanning technique for the speckle displacement.

  • PDF

Magnetic Inductance Tomography System을 이용한 대상물체의 위치와 크기 판정 (Detection of Size and Position in Magnetic Inductance Tomography System)

  • 서강;박관수;박은식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1074-1076
    • /
    • 2005
  • Magnetic Inductance Tomography System은 비투자율이 공기보다 큰 대상물체를 외부에서 자기장을 인가하여 자기장의 변화를 자기센서로 측정하여 대상물체의 형상, 위치, 비투자율을 측정하고 판단하는 시스템이다. Magnetic Inductance Tomog-raphy System은 비투자율이 공기보다 큰 대상물체를 외부에서 자기장을 인가하여 자기장의 변화를 자기센서로 측정하여 대상물체의 형상, 위치, 비투자율을 측정하고 판단하는 시스템이다. Magnetic Inductance To-mography System은 대상물체의 위치, 모양, 크기에 따라 자기장의 변화가 달라게 된다. 대상물체를 실시간으로 측정하기 위하여 Magnetic Inductance To-mography System을 자기장 발생부와 신호변환부, 모니터링 부로 구분하여 구축하였다. 또한 대상물체를 위치를 이동시키거나 크기를 변경하여 대상물체의 신호를 해석, 측정하였다.

  • PDF

Computer Tomography

  • 조장희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1981년도 하계 학술회의초록집
    • /
    • pp.29-30
    • /
    • 1981
  • PDF

사각관 이상유동 분석을 위한 전기적 캐패시턴스 토모그라피 코드 개발 (Development of an Electrical Capacitance Tomography Code for Analysis of Two-Phase Flow in the Rectangular Pipe)

  • 이경황;이재영
    • 대한기계학회논문집B
    • /
    • 제29권1호
    • /
    • pp.87-94
    • /
    • 2005
  • A computer code for Electrical Capacitance Tomography (ECT) is developed to sense the cross sectional phase distribution of two-phase flow in the rectangular pipe in which the tomography sensor furnished by the insulated wall, electrodes, and electric field screen. The computer code had two steps for the image reconstruction. In the forward projection step, the sensitivity matrix was constructed based on the electric field calculated by the finite difference method. In the backward projection step, the sensitivity matrix and the measured capacitances were used to reconstruct the cross sectional image. Several algorithms including LBP, TR, ITR, and PLI were employed to find the proper one for the two-phase flow analysis. Since the dielectric constant of the water in two-phase flow is sensitive to the thermal parameter such as, temperature and pressure, the developed code was evaluated to find their accuracy, speed of calculation, and sensitivity to the variation of the dielectric constant. It was found that the iterative methods are superior to the direct methods for the image reconstruction, and the PLI method was the best in the variation of the dielectric constants.

A STUDY ON THE DIMENSIONAL ACCURACY OF MODELS USING 3-DIMENSIONAL COMPUTER TOMOGRAPHY AND 2 RAPID PROTOTYPING METHODS

  • Cho Lee-Ra;Park Chan-Jin;Park In-Woo
    • 대한치과보철학회지
    • /
    • 제39권6호
    • /
    • pp.633-640
    • /
    • 2001
  • Statement of problem. Relatively low success rate of root analogue implant system was supposed to be due to the time duration between extraction and implant installation. The use of three-dimensional computer tomography and the reconstruction of objects using rapid prototyping methods would be helpful to shorten this time. Purpose. This aim of this study was to evaluate the application possibility of the 3-dimensional computer tomography and the rapid prototyping to root analogue implants. Material and methods. Ten single rooted teeth were prepared. Width and height of the teeth were measured by the marking points. This was followed by CT scanning, data conversion and rapid prototyping model fabrication. 2 methods were used; fused deposition modelling and stereolithography. Same width and height of this models were measured and compared to the original tooth. Results. Fused deposition modelling showed an enlarged width and reduced height. The stereolithography showed more exact data compared with the fused deposition modelling. Smaller standard deviation were recorded in the stereolithographic method. Overall width error from tooth to rapid prototyping was 7.15% in fused deposition modelling and 0.2% in stereolithography. Overall height showed the tendency of reducing dimensions. Conclusion. From the results of this study, stereolithography seems to be very predictable method of fabricating root analogue implant.

  • PDF

Micro-CT 활용 콘크리트 내 철근 부식 정량을 위한 실험적 연구 (Corrosion Quantification of Reinforcing Bar in Concrete Using Micro Computer Tomography)

  • 장인동;이종구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.252-253
    • /
    • 2019
  • Corrosion of rebars in reinforced concrete structures is a major factor that shortens the life of the structure. As corrosion progresses, the adhesion between the concrete tissues and the rebar decreases and the cracks in the concrete due to the expansion of the oxide intensify. Although it is necessary to measure corrosion behavior of rebars inside the concrete to measure degradation of structures due to rebar corrosion, no studies have been conducted to measure corrosion of rebars in In-situ state. In this study, corrosion of rebars in reinforced concrete specimens was attempted to be quantified using micro-computer tomography. Since corrosion of concrete takes several months per 10mm of cover, accelerated corrosion techniques were applied. Accelerated corrosion on the specimen was conducted by applying a 10 V magnetic field to the buried rebar and external electrodes with the specimen submerged in a 10% calcium chloride solution. The experiment found that within two weeks, more than 40% of rebar reduction occurred, and the cracks in the radial cracks occurred through the concrete structure, leading to the transfer of the oxide produced through the cracks to the surface of the specimen.

  • PDF

Coronary Artery Stenosis Quantification for Computed Tomography Angiography Based on Modified Student's t-Mixture Model

  • Sun, Qiaoyu;Yang, Guanyu;Shu, Huazhong;Shi, Daming
    • ETRI Journal
    • /
    • 제39권5호
    • /
    • pp.662-671
    • /
    • 2017
  • Coronary artery disease (CAD) is a major cause of death in the world. As a non-invasive imaging modality, computed tomography angiography (CTA) is now usually used in clinical practice for CAD diagnosis. Precise quantification of coronary stenosis is of great interest for diagnosis and treatment planning. In this paper, a novel cluster method based on a Modified Student's t-Mixture Model is applied to separate the region of vessel lumen from other tissues. Then, the area of the vessel lumen in each slice is computed and the estimated value of it is fitted with a curve. Finally, the location and the level of the most stenoses are captured by comparing the calculated and fitted areas of the vessel. The proposed method has been applied to 17 clinical CTA datasets and the results have been compared with reference standard degrees of stenosis defined by an expert. The results of the experiment indicate that the proposed method can accurately quantify the stenosis of the coronary artery in CTA.

전산화단층촬영 영상에서 지방간의 감별진단을 위한 컴퓨터보조진단의 응용 (Application of Computer-Aided Diagnosis for the Differential Diagnosis of Fatty Liver in Computed Tomography Image)

  • 박형후;이진수
    • 한국방사선학회논문지
    • /
    • 제10권6호
    • /
    • pp.443-450
    • /
    • 2016
  • 본 연구는 복부 전산화단층촬영 영상을 이용하여 지방간환자의 영상을 질감특징분석과 ROC curve 분석을 하였으며, 컴퓨터보조진단시스템의 구현을 위한 실험적인 선형 연구로서 전산화단층촬영 영상에서 지방간의 객관적이고 신뢰성 있는 진단 정보를 의사에게 제공하고자 하였다. 실험은 정상 및 지방간 복부 전산화단층촬영 영상을 실험영상으로 하여 설정된 구역에 대한 wavelet 변환을 거쳐 질감의 특징값을 나타내는 6가지 파라미터로 통계적 분석 결과를 나타내었다. 그 결과 엔트로피, 평균밝기, 왜곡도는 90% 이상의 비교적 높은 인식률을 보였고, 대조도, 평탄도, 균일도는 약 70% 정도로 비교적 낮은 인식률을 나타내었다. ROC curve를 이용한 분석에서 6가지의 파라미터 모두 0.900(p=0.0001)이상을 나타내어 질환인식에 의미가 있는 결과를 나타내었다. 또한 6가지 파라미터에서 질환 예측을 위한 cut-off 값을 결정하였다. 이러한 결과는 향후 복부 전산화단층촬영 영상에서 질환 자동검출 및 최종진단의 예비 진단 자료로서 적용 가능할 것이다.