• Title/Summary/Keyword: computed tomography image

Search Result 974, Processing Time 0.034 seconds

The evaluation of properties for radiation therapy techniques with flattening filter-free beam and usefulness of time and economy to a patient with the radiation therapy (Flattening filter-free beam을 이용한 방사선 치료 기법의 특성 및 환자의 시간적.경제적 유용성 평가)

  • Goo, Jang Hyeon;Won, Hui Su;Hong, Joo Wan;Chang, Nam Jun;Park, Jin Hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.363-368
    • /
    • 2014
  • Purpose : The aim of this study was to appraise properties for radiation therapy techniques and effectiveness of time and economy to a patient in the case of applying flattening filter-free (3F) and flattening filter (2F) beam to the radiation therapy. Materials and Methods : Alderson rando phantom was scanned for computed tomography image. Treatment plans for intensity modulated radiation therapy (IMRT), volumetric modulated arc therapy (VMAT) and stereotactic body radiation therapy (SBRT) with 3F and 2F beam were designed for prostate cancer. To evaluate the differences between the 3F and 2F beam, total monitor units (MUs), beam on time (BOT) and gantry rotation time (GRT) were used and measured with $TrueBeam^{TM}$ STx and Surveillance And Measurement (SAM) 940 detector was used for photoneutron emitted by using 3F and 2F. To assess temporal and economical aspect for a patient, total treatment periods and medical fees were estimated. Results : In using 3F beam, total MUs in IMRT plan increased the highest up to 34.0% and in the test of BOT, GRT and photoneutron, the values in SBRT plan decreased the lowest 39.8, 38.6 and 48.1%, respectively. In the temporal and economical aspect, there were no differences between 3F and 2F beam in all of plans and the results showed that 10 days and 169,560 won was lowest in SBRT plan. Conclusion : According as the results, total MUs increased by using 3F beam than 2F beam but BOT, GRT and photoneutron decreased. From above the results, using 3F beam can decrease intra-fraction setup error and risk of radiation-induced secondary malignancy. But, using 3F beam did not make the benefits of temporal and economical aspect for a patient with the radiation therapy.

The Role and Efficacy of Diagnostic Laparoscopy to Detect the Peritoneal Recurrence of Gastric Cancer (복막 전이가 의심되는 위암 환자에서 진단적 복강경 검사의 의의와 역할)

  • Song, Sun-Choon;Lee, Sang-Lim;Cho, Young-Kwan;Han, Sang-Uk
    • Journal of Gastric Cancer
    • /
    • v.9 no.2
    • /
    • pp.51-56
    • /
    • 2009
  • Purpose: Peritoneal recurrence has been reported to be the most common form of recurrence of gastric cancer. Peritoneal recurrence can generally be suggested by several types of image studies and also if there is evidence of ascites or Bloomer's rectal shelf. It can be confirmed by explorative laparotomy, but diagnostic laparoscopy is a good alternative method and laparoscopic surgery has also been widely used. We reviewed and analyzed the ability of diagnostic laparoscopy to detect peritoneal recurrence or carcinomatosis, and especially for gastric cancer. Materials and Methods: We performed a retrospective review the 45 gastric cancer patients who were operated via diagnostic laparoscopy between 2004. 2. and 2009. 3. We analyzed the perioperative clinical characteristics and the accuracy of the diagnostic methods. Results: The study groups included 14 patients who had confirmed gastric cancer, but they suspected to have carcinomatosis, and 31 patients who had previously underwent gastric resection, but they suspected to have recurrence. The mean operation time was $44.1\pm26.9$ minutes and the mean postoperative hospital stay was $2.7\pm2.8$ days. There was one case of operation-related complication and no postoperative mortality occurred. The sensitivities for detecting peritoneal recurrence or carcinomatosis were 92.1% for diagnostic laparoscopy, 29.7% for detecting ascites and rectal shelf on the physical examination, 86.5% for abdominal computed tomography, 69.2% for PET CT and 18.8% for CEA. Conclusion: Diagnostic laparoscopy does not require a long operation time or a long hospital stay, and it showed a low complication rate in our study. It has high sensitivity for detecting peritoneal recurrence of gastric cancer. It can be an alternative diagnostic confirmative method and it is useful for deciding on further treatment.

  • PDF

Assessment of Viability in Regional Myocardium with Reversed Redistribution by Thallium Reinjection in Patients with Acute Myocardial Infarction (급성심근경색 환자에서 역재분포를 보인 심근의 Thallium 재주사에 의한 생존능의 평가)

  • Yoon, Seok-Nam;Park, Chan-H.;Pai, Moon-Sun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.6
    • /
    • pp.509-515
    • /
    • 1998
  • Purpose: The aim of this study was to evaluate whether T1-201 reinjection distinguishes viable from non-viable myocardium in patients with reverse redistribution after acute myocardial infarction. Materials and Methods: We studied 42 patients with acute myocardial infarction (age, $55{\pm}12$ years). Eighteen (43%) out of 42 showed reverse redistribution on dipyridamole stress-4 hour redistribution T1-201 single photon emission computed tomography (SPECT). T1-201 reinjection was performed at 24 hours. Reverse redistribution was defined as worsening of perfusion defect at 4 hour delayed scan. All patients underwent follow-up echocardiography in 4 months to assess regional wall motion improvement. T1-201 uptake on reinjection images were analyzed for the prediction of myocardial wall motion improvement. Results: Of 36 segments with reverse redistribution, 17 segments showed normal wall motion on echocardiography, while 19 segments showed wall motion abnormalities. Of 19 the segments with reverse redistribution, 11 (58%) showed enhanced uptake after 24 hour reinjection. Myocardial wall motion was improved in 10 of 11 segments (90%) with enhanced uptake on reinjection. Wall motion improvement was not seen in 5 of 8 segments (63%) without enhanced thallium uptake. When myocardial viability was assessed by the uptake on reinjection image, nine of 10 segments (90%) with normal or mildly decreased uptake showed improved wall motion. Wall motion was not improved in 5 of 9 segments (16%) with severely decreased uptake. Conclusion: In patients with acute myocardial infarction, T1-201 reinjection imaging on myocardial segments with reverse redistribution has a high positive predictive value in the assessment of myocardial viability.

  • PDF

Effect of Noise on Density Differences of Tissue in Computed Tomography (컴퓨터 단층촬영의 조직간 밀도차이에 대한 노이즈 영향)

  • Yang, Won Seok;Son, Jung Min;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.403-407
    • /
    • 2018
  • Currently, the highest cancer death rate in Korea is lung cancer, which is a typical cancer that is difficult to detect early. Low-dose chest CT is being used for early detection, which has a greater lung cancer diagnosis rate of about three times than regular chest x-ray images. However, low-dose chest CT not only significantly reduces image resolution but also has a weak signal and is sensitive to noise. Also, air filled lungs are low-density organs and the presence of noise can significantly affect early diagnosis of cancer. This study used Visual C++ to set a circle inside a large circle with a density of 2.0, with a density of 1.0, which is the density of water, in which five small circle of mathematics have different densities. Gaussian noise was generated by 1%, 2%, 3%, and 4% respectively to determine the effect of noise on the mean value, the standard deviation value, and the relative noise ratio(SNR). In areas where the density difference between the large and small circles was greatest in the event of 1 % noise, the SNR in the area with the greatest variation in noise was 4.669, and in areas with the lowest density difference, the SNR was 1.183. In addition, the SNR values can be seen to be high if the same results are obtained for both positive and negative densities. Quality was also clearly visible when the density difference was large, and if the noise level was increased, the SNR was reduced to significantly affect the noise. Low-density organs or organs in areas of similar density to cancers, will have significant noise effects, and the effects of density differences on the probability of noise will affect diagnosis.

Experiences of the First 130 Patients in Gangnam Severance Hospital (강남세브란스병원 토모테라피를 이용한 치료환자의 130예 통계분석 및 경험)

  • Ha, Jin-Sook;Jeon, Mi-Jin;Kim, Sei-Joon;Kim, Jong-Dae;Shin, Dong-Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.45-53
    • /
    • 2008
  • Purpose: We are trying to analyze 130 patients' conditions by using our Helical Tomotherapy, which was installed in our center in Oct. 2007. We will be statistically approach this examination and analyze so that we will be able to figure out adaptive plans according to the change in place of the tumor, GTV (gross tumor volume), total amount of time it took, vector (${\upsilon}=\surd$x2+y2+z2) and the change in size of the tumor. Materials and Methods: Objectives were the patients who were medicated with Tomotherapy in our medical center since Oct. 2007 August 2008. The Average age of the patients were 53 years old (Minimum 25 years old, Maximum 83 years old). The parts of the body we operated were could be categorized as Head&neck (n=22), Chest (n=47), Abdomen (n=25), Pelvis (n=11), Bone (n=25). MVCT had acted on 2702 times, and also had acted on our adaptive plan toward patients who showed big difference in the size of tumor. Also, after equalizing our gained MVCT and kv-CT we checked up on the range of possible mistake, using x, y, z, roll and vector. We've also investigated on Set-up, MVCT, average time of operation and target volume. Results: Mean time on table was 22.8 minutes. Mean treatment time was 13.26 minutes. Mean correction (mm) was X=-0.7, Y=-1.4, Z=5.77, roll=0.29, vector=8.66 Head&neck patients had 2.96 mm less vector value in movement than patients of Chest, Abdomen, Bone. In increasing order, Head&neck, Bone, Abdomen, Chest, Pelvis showed the vector value in movement. Also, there were 27 patients for adaptive plan, 39 patients, who had long or multiple tumor. We could know that When medical treatment is one cure plan, it takes 32 minutes, and when medical treatment is two cure plan, it takes 40 minutes that one medical treatment takes 21 minutes, and the other medical treatment takes 19 minutes. Conclusion:With our basic tools, we could bring more accurate IMRT with MVCT. Also, through our daily image, we checked up on the change in tumor so that adaptive plan could work. It was made it possible to take the cure of long or multiple tumor, the cure in a nearby OAR, and the complicated cure that should make changes of gradient dose distribution.

  • PDF

CT Measurement of Diameter and Dimension of the Trachea in Normal Korean Adults (흥부 전산화단층촬영을 이용한 한국성인의 기관내경과 단면적의 측정)

  • Han, Jae-Youl;Kim, Kwang-Ho;Lee, Gun;Kim, Hyung-Jin;Cho, Soon-Koo;Sun, Kyung
    • Journal of Chest Surgery
    • /
    • v.34 no.7
    • /
    • pp.534-538
    • /
    • 2001
  • Background: Knowledge of size and morphology of the normal trachea is important for airway management and tracheal reconstruction. Conventional radiography is a simple method used to measure the tracheal diameter, but it is not accurate because of the artifacts related to image magnification and overlapping by the shoulder. The purpose of this study was to provide the normal values of the tracheal size and anatomy in Korean adults using Computerized Topography. Material and Method: There were 43 men and 34 women included in this study. They were divided into three age groups(group 1, 20-39 years ; group 2, 40-59 yeas , groups 3, $\geq$60 years). The anteroposterior and transverse diameters and cross - sectional areas of the trachea were measured at the level of the thoracic inlet(Level 1) and the aortic arch(Level 2). These values obtained at each level were compared between age groups and sexes. Result: In 43 men, the anteroposterior / transverse diameters(mean SD in millimeters) of the trachea at levels 1 and 2 were 19.95$\pm$2.99 / 17.72$\pm$2.13 and 19.77$\pm$2.57 / 18.02$\pm$2.19, respectively. In 34 women, those values at levels 1 and 2 were 15.56$\pm$2.12 / 14.18$\pm$2.07 and 15.35$\pm$1.82 / 15.00$\pm$1.60, respectively. At both levels, the anteroposterior and transverse diameters were significantly greater in men than in women (p<0.05). The cross-sectional area of the trachea at levels 1 and 2 were 279.14$\pm$61.37 / 281.93$\pm$63.97 $\textrm{mm}^2$ in men and 173.29$\pm$35.81 / 181.88$\pm$34.74 in women, respectively. They also showed significantly greater values in men than in women(P<0.05). There was no significant difference in diameters and cross-sectional areas of the trachea between age groups. Conclusion: There are significant differences in the internal diameter and cross- sectional area of the trachea between men and women in normal Korean adults, while the age difference was insignificant. We believed CT is a relatively accurate and safe way to measure the internal diameter and cross-sectional areas of the trachea.

  • PDF

Usefulness of $^{99m}Tc$-labeled RBC Scan and SPECT in the Diagnosis of Head and Neck Hemangiomas (두경부 혈관종 진단시 $^{99m}Tc$-RBC Scan and SPECT 검사의 유용성)

  • Oh, Shin-Hyun;Roh, Dong-Wook;Ahn, Sha-Ron;Park, Hoon-Hee;Lee, Seung-Jae;Kang, Chun-Goo;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.39-43
    • /
    • 2008
  • Purpose: There are various methods to diagnose hemangioma, such as ultrasonography (US), computed tomography (CT), magnetic resonance imaging (MRI) and nuclear medicine. However, by development of SPECT imaging, the blood-pool scan using $^{99m}Tc$-labeled red blood cell has been used, because it was non-invasive and the most economical method. Therefore, in this study, we proposed that the usefulness of $^{99m}Tc$-RBC scan and SPECT of the head and neck to diagnose unlocated hemangiomas. Materials and Methods: $^{99m}Tc$-RBC scan and SPECT was performed on 6 patients with doubtful hemangioma (4 person, head; 1 person, neck; 1 person, another). We labeled radiopharmaceutical using modified in vivo method and then, centrifuged it to remove plasma. After a bolus injection of tracer, dynamic perfusion flow images were acquired. Then, anterior, posterior, both lateral static blood-pool images were obtained as early and 4 hours delayed. SPECT was progressed 64 projections per 30 seconds. Each image was interpreted by physicians, Nuclear medicine specialist, and technologist blinded to patient's data. Results: In 5 patients of all the radioactivity of doubtful site didn't change in flow images, but, in blood-pool, delayed and SPECT images, it was increased. So, it was a typical hemangioma finding. The size of lesion was over 2 cm, and it could discriminate as comparing to the delayed and SPECT imaging. On the other hand, in 1 patient, the radioactivity was increased in blood-pool images, but, not in delayed and SPECT images, so, it was proved no hemangioma. Conclusion: Using $^{99m}Tc$-RBC Scan and SPECT, we could diagnose the hemangiomas in head and neck, as well as, liver, more non-invasive, economical, and easy. Therefore, it considered that $^{99m}Tc$-RBC scan and SPECT would offer more useful information for diagnosis of hemangioma, rather than otherimaging such as US, CT, MRI.

  • PDF

Evaluation of Target Position's Accuracy in 2D-3D Matching using Rando Phantom (인체팬톰을 이용한 2D-3D 정합시 타켓위치의 정확성 평가)

  • Jang, Eun-Sung;Kang, Soo-Man;Lee, Chul-Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.33-39
    • /
    • 2009
  • Purpose: The aim of this study is to compare patient's body posture and its position at the time of simulation with one at the treatment room using On-board Imaging (OBI) and CT (CBCT). The detected offsets are compared with position errors of Rando Phantom that are practically applied. After that, Rando Phantom's position is selected by moving couch based on detected deviations. In addition, the errors between real measured values of Rando Phantom position and theoretical ones is compared. And we will evaluate target position's accuracy of KV X-ray imaging's 2D and CBCT's 3D one. Materials and Methods: Using the Rando Phantom (Alderson Research Laboratories Inc. Stanford. CT, USA) which simulated human body's internal structure, we will set up Rando Phantom on the treatment couch after implementing simulation and RTP according to the same ways as the real radioactive treatment. We tested Rando Phantom that are assumed to have accurate position with different 3 methods. We measured setup errors on the axis of X, Y and Z, and got mean standard deviation errors by repeating tests 10 times on each tests. Results: The difference between mean detection error and standard deviation are as follows; lateral 0.4+/-0.3 mm, longitudinal 0.6+/-0.5 mm, vertical 0.4+/-0.2 mm which all within 0~10 mm. The couch shift variable after positioning that are comparable to residual errors are 0.3+/-0.1, 0.5+/-0.1, and 0.3+/-0.1 mm. The mean detection errors by longitudinal shift between 20~40 mm are 0.4+/-0.3 in lateral, 0.6+/-0.5 in longitudinal, 0.5+/-0.3 in vertical direction. The detection errors are all within range of 0.3~0.5 mm. Residual errors are within 0.2~0.5 mm. Each values are mean values based on 3 tests. Conclusion: Phantom is based on treatment couch shift and error within the average 5mm can be gained by the diminution detected by image registration based on OBI and CBCT. Therefore, the selection of target position which depends on OBI and CBCT could be considered as useful.

  • PDF

Evaluation of the accuracy of two different surgical guides in dental implantology: stereolithography fabricated vs. positioning device fabricated surgical guides (제작방법에 따른 임플란트 수술 가이드의 정확성비교: stereolithography와 positioning device로 제작한 수술 가이드)

  • Kwon, Chang-Ryeol;Choi, Byung-Ho;Jeong, Seung-Mi;Joo, Sang-Dong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.271-278
    • /
    • 2012
  • Purpose: Recently implant surgical guides were used for accurate and atraumatic operation. In this study, the accuracy of two different types of surgical guides, positioning device fabricated and stereolithography fabricated surgical guides, were evaluated in four different types of tooth loss models. Materials and methods: Surgical guides were fabricated with stereolithography and positioning device respectively. Implants were placed on 40 models using the two different types of surgical guides. The fitness of the surgical guides was evaluated by measuring the gap between the surgical guide and the model. The accuracy of surgical guide was evaluated on a pre- and post-surgical CT image fusion. Results: The gap between the surgical guide and the model was $1.4{\pm}0.3mm$ and $0.4{\pm}0.3mm$ for the stereolithography and positioning device surgical guide, respectively. The stereolithography showed mesiodistal angular deviation of $3.9{\pm}1.6^{\circ}$, buccolingual angular deviation of $2.7{\pm}1.5^{\circ}$ and vertical deviation of $1.9{\pm}0.9mm$, whereas the positioning device showed mesiodistal angular deviation of $0.7{\pm}0.3^{\circ}$, buccolingual angular deviation of $0.3{\pm}0.2^{\circ}$ and vertical deviation of $0.4{\pm}0.2mm$. The differences were statistically significant between the two groups (P<.05). Conclusion: The laboratory fabricated surgical guides using a positioning device allow implant placement more accurately than the stereolithography surgical guides in dental clinic.

Automatic Fracture Detection in CT Scan Images of Rocks Using Modified Faster R-CNN Deep-Learning Algorithm with Rotated Bounding Box (회전 경계박스 기능의 변형 FASTER R-CNN 딥러닝 알고리즘을 이용한 암석 CT 영상 내 자동 균열 탐지)

  • Pham, Chuyen;Zhuang, Li;Yeom, Sun;Shin, Hyu-Soung
    • Tunnel and Underground Space
    • /
    • v.31 no.5
    • /
    • pp.374-384
    • /
    • 2021
  • In this study, we propose a new approach for automatic fracture detection in CT scan images of rock specimens. This approach is built on top of two-stage object detection deep learning algorithm called Faster R-CNN with a major modification of using rotated bounding box. The use of rotated bounding box plays a key role in the future work to overcome several inherent difficulties of fracture segmentation relating to the heterogeneity of uninterested background (i.e., minerals) and the variation in size and shape of fracture. Comparing to the commonly used bounding box (i.e., axis-align bounding box), rotated bounding box shows a greater adaptability to fit with the elongated shape of fracture, such that minimizing the ratio of background within the bounding box. Besides, an additional benefit of rotated bounding box is that it can provide relative information on the orientation and length of fracture without the further segmentation and measurement step. To validate the applicability of the proposed approach, we train and test our approach with a number of CT image sets of fractured granite specimens with highly heterogeneous background and other rocks such as sandstone and shale. The result demonstrates that our approach can lead to the encouraging results on fracture detection with the mean average precision (mAP) up to 0.89 and also outperform the conventional approach in terms of background-to-object ratio within the bounding box.