• 제목/요약/키워드: computed tomography image

검색결과 980건 처리시간 0.031초

Perceptually Enhanced Matching을 사용한 삼차원 의학영상 Fractal Coding (Three Dimensional Fractal Coding of Medical Images with Perceptually Enhanced Matching)

  • 신흥식;안창범
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 춘계학술대회
    • /
    • pp.131-134
    • /
    • 1995
  • A three dimensional fractal coding with a perceptually enhanced matching is proposed. Since most of medical images (e.g. computed tomography or magnetic resonance image) have three dimensional character, the searching region is extended to adjacent slices. For perceptually enhanced matching, a high frequency booster filter is used for prefiltering of the original image, and the least mean square error matching is applied to this edge enhanced image rather than the original image. From the simulation with the magnetic resonance images ($255{\times}255$, 8bits/pixel). the proposed algorithm provides excellent image quality with compression rations higher than 10. Compared to existing fractal coding the algorithm also provides better subjective image quality with higher compression ratio.

  • PDF

Sparse-View CT Image Recovery Using Two-Step Iterative Shrinkage-Thresholding Algorithm

  • Chae, Byung Gyu;Lee, Sooyeul
    • ETRI Journal
    • /
    • 제37권6호
    • /
    • pp.1251-1258
    • /
    • 2015
  • We investigate an image recovery method for sparse-view computed tomography (CT) using an iterative shrinkage algorithm based on a second-order approach. The two-step iterative shrinkage-thresholding (TwIST) algorithm including a total variation regularization technique is elucidated to be more robust than other first-order methods; it enables a perfect restoration of an original image even if given only a few projection views of a parallel-beam geometry. We find that the incoherency of a projection system matrix in CT geometry sufficiently satisfies the exact reconstruction principle even when the matrix itself has a large condition number. Image reconstruction from fan-beam CT can be well carried out, but the retrieval performance is very low when compared to a parallel-beam geometry. This is considered to be due to the matrix complexity of the projection geometry. We also evaluate the image retrieval performance of the TwIST algorithm -sing measured projection data.

Assessment of bifid and trifid mandibular canals using cone-beam computed tomography

  • Rashsuren, Oyuntugs;Choi, Jin-Woo;Han, Won-Jeong;Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • 제44권3호
    • /
    • pp.229-236
    • /
    • 2014
  • Purpose: To investigate the prevalence of bifid and trifid mandibular canals using cone-beam computed tomography (CBCT) images, and to measure their length, diameter, and angle. Materials and Methods: CBCT images of 500 patients, involving 755 hemi-mandibles, were used for this study. The presence and type of bifid mandibular canal was evaluated according to a modified classification of Naitoh et al. Prevalence rates were determined according to age group, gender, and type. Further, their diameter, length, and angles were measured using PACSPLUS Viewer and ImageJ 1.46r. Statistical analysis with chi-squared and analysis of variance (ANOVA) tests was performed. Results: Bifid and trifid mandibular canals were found in 22.6% of the 500 patients and 16.2% of the 755 sides. There was no significant difference between genders and among age groups. The retromolar canal type accounted for 71.3% of the identified canals; the dental canal type, 18.8%; the forward canal type, 4.1%; and the trifid canal type, 5.8%. Interestingly, seven cases of the trifid canal type, which has been rarely reported, were observed. The mean diameter of the bifid and trifid mandibular canals was 2.2 mm and that of the main mandibular canal was 4.3 mm. Their mean length was 16.9 mm; the mean superior angle was $149.2^{\circ}$, and the mean inferior angle was $37.7^{\circ}$. Conclusion: Bifid and trifid mandibular canals in the Korean population were observed at a relatively high rate through a CBCT evaluation, and the most common type was the retromolar canal. CBCT is suggested for a detailed evaluation of bifid and trifid mandibular canals before mandibular surgery.

Use of Reference Ear Plug to improve accuracy of lateral cephalograms generated from cone-beam computed tomography scans

  • Hwang, Hyeon-Shik;Lee, Kyung-Min;Uhm, Gi-Soo;Cho, Jin-Hyoung;McNamara, James A. Jr.
    • 대한치과교정학회지
    • /
    • 제43권2호
    • /
    • pp.54-61
    • /
    • 2013
  • Objective: The purpose of this study was to evaluate the effectiveness of the use of Reference Ear Plug (REP) during cone-beam computed tomography (CBCT) scan for the generation of lateral cephalograms from CBCT scan data. Methods: Two CBCT scans were obtained from 33 adults. One CBCT scan was acquired using conventional methods, and the other scan was acquired with the use of REP. Virtual lateral cephalograms created from each CBCT image were traced and compared with tracings of the real cephalograms obtained from the same subject. Results: CBCT scan with REP resulted in a smaller discrepancy between real and virtual cephalograms. In comparing the real and virtual cephalograms, no measurements significantly differed from real cephalogram values in case of CBCT scan with REP, whereas many measurements significantly differed in the case of CBCT scan without REP. Conclusion: Measurements from CBCT-generated cephalograms are more similar to those from real cephalograms when REP are used during CBCT scan. Thus, the use of REP is suggested during CBCT scan to generate accurate virtual cephalograms from CBCT scan data.

Comparison of 2 root surface area measurement methods: 3-dimensional laser scanning and cone-beam computed tomography

  • Tasanapanont, Jintana;Apisariyakul, Janya;Wattanachai, Tanapan;Sriwilas, Patiyut;Midtbo, Marit;Jotikasthira, Dhirawat
    • Imaging Science in Dentistry
    • /
    • 제47권2호
    • /
    • pp.117-122
    • /
    • 2017
  • Purpose: The aim of this study was to compare the use of 3-dimensional (3D) laser scanning and cone-beam computed tomography (CBCT) as methods of root surface measurement. Materials and Methods: Thirty teeth (15 maxillary first premolars and 15 mandibular first premolars) from 8 patients who required extractions for orthodontic treatment were selected. Before extraction, pre-treatment CBCT images of all the patients were recorded. First, a CBCT image was imported into simulation software (Mimics version 15.01; Materialise, Leuven, Belgium) and the root surface area of each tooth was calculated using 3-Matic (version 7.01, Materialise, Leuven, Belgium). After extraction, all the teeth were scanned and the root surface area of each extracted tooth was calculated. The root surface areas calculated using these 2 measurement methods were analyzed using the paired t-test (P<.05). Correlations between the 2 methods were determined by calculating the Pearson correlation coefficient. The intraclass correlation coefficient(ICC) was used to assess intraobserver reliability. Results: The root surface area measurements ($230.11{\pm}41.97mm^2$) obtained using CBCT were slightly greater than those ($229.31{\pm}42.46mm^2$) obtained using 3D laser scanning, but not significantly (P=.425). A high Pearson correlation coefficient was found between the CBCT and the 3D laser scanner measurements. The intraobserver ICC was 1.000 for 3D laser scanning and 0.990 for CBCT. Conclusion: This study presents a novel CBCT approach for measuring the root surface area; this technique can be used for estimating the root surface area of non-extracted teeth.

급성 족근과 골절 환자에서 시행한 컴퓨터 단층촬영 영상의 유용성 (Usefulness of Computed Tomography in Patients with Acute Malleolar Fracture)

  • 전숙하;배서영;안수형;정형진;우승훈
    • 대한족부족관절학회지
    • /
    • 제19권4호
    • /
    • pp.156-160
    • /
    • 2015
  • Purpose: We compared plain radiographs with computed tomography (CT) images to evaluate the usefulness of preoperative CT in acute ankle malleolar fracture in terms of accuracy of diagnosis and planning of operative strategy. Materials and Methods: A retrospective analysis was conducted on 210 cases of malleolar fracture treated at our institute for which plain radiograph and CT were obtained preoperatively. Observers had reviewed plain radiographs and recorded fracture classification, anatomical diagnosis, extent and configuration of fractures and then subsequently reviewed CT images. Records from each image were compared and information regarding the differences in fractures was assessed. Results: Fractures were notably changed in appearance in 88 cases (41.9%) and diagnosis changed in 30 cases (14.3%). According to the change of diagnosis and fracture appearances, the operative strategy was changed in 15 cases (7.1%) including incision, order of reduction, and target of fixation. Conclusion: CT could be a useful adjunctive imaging tool in addition to the plain radiograph in planning of operative treatment for acute malleolar fracture in terms of estimating exact configuration, extent of fractures and even newly revealed hidden fractures.

Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography

  • Sabban, Hanadi;Mahdian, Mina;Dhingra, Ajay;Lurie, Alan G.;Tadinada, Aditya
    • Imaging Science in Dentistry
    • /
    • 제45권2호
    • /
    • pp.73-80
    • /
    • 2015
  • Purpose: This study evaluated the effect of various head orientations during cone-beam computed tomography (CBCT) image acquisition on linear measurements of potential implant sites. Materials and Methods: Six dry human skulls with a total of 28 implant sites were evaluated for seven different head orientations. The scans were acquired using a Hitachi CB-MercuRay CBCT machine. The scanned volumes were reconstructed. Horizontal and vertical measurements were made and were compared to measurements made after simulating the head position to corrected head angulations. Data was analyzed using a two-way ANOVA test. Results: Statistical analysis revealed a significant interaction between the mean errors in vertical measurements with a marked difference observed at the extension head position (P<0.05). Statistical analysis failed to yield any significant interaction between the mean errors in horizontal measurements at various head positions. Conclusion: Head orientation could significantly affect the vertical measurements in CBCT scans. The main head position influencing the measurements is extension.

Detection of furcation involvement using periapical radiography and 2 cone-beam computed tomography imaging protocols with and without a metallic post: An animal study

  • Salineiro, Fernanda Cristina Sales;Gialain, Ivan Onone;Kobayashi-Velasco, Solange;Pannuti, Claudio Mendes;Cavalcanti, Marcelo Gusmao Paraiso
    • Imaging Science in Dentistry
    • /
    • 제47권1호
    • /
    • pp.17-24
    • /
    • 2017
  • Purpose: The purpose of this study was to assess the accuracy, sensitivity, and specificity of the diagnosis of incipient furcation involvement with periapical radiography (PR) and 2 cone-beam computed tomography (CBCT) imaging protocols, and to test metal artifact interference. Materials and Methods: Mandibular second molars in 10 macerated pig mandibles were divided into those that showed no furcation involvement and those with lesions in the furcation area. Exams using PR and 2 different CBCT imaging protocols were performed with and without a metallic post. Each image was analyzed twice by 2 observers who rated the absence or presence of furcation involvement according to a 5-point scale. Receiver operating characteristic (ROC) curves were used to evaluate the accuracy, sensitivity, and specificity of the observations. Results: The accuracy of the CBCT imaging protocols ranged from 67.5% to 82.5% in the images obtained with a metallic post and from 72.5% to 80% in those without a metallic post. The accuracy of PR ranged from 37.5% to 55% in the images with a metallic post and from 42.5% to 62.5% in those without a metallic post. The area under the ROC curve values for the CBCT imaging protocols ranged from 0.813 to 0.802, and for PR ranged from 0.503 to 0.448. Conclusion: Both CBCT imaging protocols showed higher accuracy, sensitivity, and specificity than PR in the detection of incipient furcation involvement. Based on these results, CBCT may be considered a reliable tool for detecting incipient furcation involvement following a clinical periodontal exam, even in the presence of a metallic post.

The Clinical Analysis of the Nasal Septal Cartilage by Measurement Using Computed Tomography

  • Hwang, So Min;Lim, On;Hwang, Min Kyu;Kim, Min Wook;Lee, Jong Seo
    • 대한두개안면성형외과학회지
    • /
    • 제17권3호
    • /
    • pp.140-145
    • /
    • 2016
  • Background: The nasal septal cartilage is often used as a donor graft in rhinoplasty operations but can vary widely in size across the patient population. As such, preoperative estimation of the cartilaginous area is important for patient counseling as well as operating planning. We aim to estimate septal cartilage area by using facial computed tomography (CT) studies. Methods: The study was performed using facial CT images taken from 200 patients between January 2012 to July 2015. Using the mid-sagittal image, the boundary of cartilaginous septum was delineated from soft tissue using the mean difference in signal intensity (or brightness). The area within this boundary was calculated. The calculated area for septal cartilage was then compared across age groups and sexes. Results: Overall, the mean area of nasal septal cartilage was $8.18cm^2$ with the maximum of $12.42cm^2$ and the minimum of $4.89cm^2$. The cartilage areas were measured to be larger in men than in women (p<0.05). The area decreased with advancing age (p<0.05). Conclusion: Measuring the size of septal cartilage using brightness difference is more precise and reliable than previously reported methods. This method can be utilized as the standard for prevention of postoperative complication.

하악 전돌증 환자에서 전산화 단층 촬영을 이용한 하악관의 해부학적 위치에 관한 연구 (STUDY ON THE ANATOMICAL POSITION OF MANDIBULAR CANAL USING COMPUTED TOMOGRAPHY IN MANDIBULAR PROGNATHISM PATIENTS)

  • 이동현;김재원;이수연;김재현;안상헌;이상한;장현중
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제31권6호
    • /
    • pp.510-518
    • /
    • 2009
  • Purpose: In this study, we analyzed and compared the anatomical position of the mandibular canal in normal occlusion and mandibular prognathism patients. Patients and Methods: Computed tomography image from 58 patients were divided into normal occlusion group and mandibular prognathism group, and each measurement were taken in the each measuring points(2nd premolar, 1st molar, 2nd molar, 3rd molar, ramus). Measurements were statistically analyzed by student's t-test. Results: BC (Thickness of the buccal cortex) value was 2.3~2.7 mm, CB (Distance from the canal to the lingual aspect of the buccal cortex) value was 1.3~4.3 mm, MC (Diameter of the canal) value was 3.2~3.8 mm, LI (Distance from the canal to the lingual aspect of the lingual cortex) value was 2.0~3.7 mm, TM (Thickness of the total mandible) value was 9.5~12.9 mm and CM (Distance from the canal to the inferior border of the mandible) value was 6.9~17.5 mm. Conclusion: In the comparison between two groups, there was statistically significant difference in CB value of 2nd, 3rd molar between normal occlusion and mandibular prognathism, and other value in the rest of the measuring points didn't show statistically significant difference.