Assessment of Breast Volume Change after Transverse Rectus Abdominis Myocutaneous Flap

  • Park, Sang Uk;Shim, Jeong Su
    • Archives of Plastic Surgery
    • /
    • v.39 no.6
    • /
    • pp.631-635
    • /
    • 2012
  • Background The evaluation of a breast after breast reconstruction depends on a surgeon's subjective criteria. We used computed tomography (CT) scans to obtain an objective evaluation of the postoperative results by measuring the breast volume of patients who had undergone breast reconstruction using pedicled transverse rectus abdominis myocutaneous (TRAM) flaps. This research will help in the objective postoperative evaluation of reconstructed breasts, and also in the preoperative flap size designs. Methods A total of 27 patients underwent breast reconstruction using pedicled TRAM flaps after mastectomy from September 2007 to July 2010. Of these, 10 patients who were followed up and underwent CT scans 2 or more times during the follow-up period were included in this study. We evaluated the change in breast volume over time using CT scans, and the interval breast volume change between CT scans. Results All of the 10 patients' reconstructed breasts showed a volume decrease over time. The breast volume changes in the intervals between CT scans were as follows: 5.65% decrease between the first CT and second CT scan, 2.3% decrease between the second CT and third CT scan, (statistically significant) and 1.89% decrease between the third CT and forth CT scan. (not statistically significant). Conclusions This research shows the possibility of objectively evaluating the postoperative breast volume changes. The findings will be helpful in designing the size of TRAM flaps to use on defects after mastectomy. Based on these results, we should also closely observe the reconstructed breast volume for at least 2 years.

A CT study of the prevalence of carotid artery calcification in dental patients (치과환자에서 경동맥 석회화 유발율에 대한 전산화단층사진 연구)

  • Yoon Suk-Ja;Lee Jae-Seo;Yoon Woong
    • Imaging Science in Dentistry
    • /
    • v.36 no.3
    • /
    • pp.151-155
    • /
    • 2006
  • Purpose : Stroke is one of the leading causes of death in Korea. Atherosclerotic disease in the carotid artery bifurcation is the most common cause of stroke. The carotid artery calcification is easily appreciated by CT (Computed tomography). CT is often taken in a dental hospital for the diagnosis of inflammation, injury, cyst or tumor on maxillofacial region. However, there was no report of carotid artery calcification on CT in dental patients. This study was to determine the prevalence of carotid artery calcification on CT in dental patients. Materials and Methods : The presence of carotid artery calcification was evaluated by an experienced radiologist on CT scans of 287 patients (166 males, 121 females, average age 42, range 6 to 86 years) and the medical history of the patient and the interpretation of CT were reviewed. Results : Carotid artery calcification was detected on CT scans of 57 patients (19.8%; 35 males, 22 females). All the male patients with carotid artery calcification were older than 50, and all the female patients with carotid artery calcification were older than 60. Among the 57 patients, 10 had Diabetes mellitus, 20 had cardiovascular disease, 3 had history of stroke and 3 underwent radiation therapy for head and neck cancer. Carotid artery calcification was not included in the interpretation of CT of dental patients except one patient. Conclusion : The prevalence of carotid artery calcification on CT of dental patients was about 20% in this study. Carotid artery calcification should be included in the interpretation of CT of dental patients.

  • PDF

Magnification Device of Computed Tomography in Radiation Therapy Planning (방사선치료계획을 위한 진단용 CT 영상의 확대장치)

  • Yoon, Sei-Chul;Kim, Jong-Woo;Bahk, Yong-Whee
    • Radiation Oncology Journal
    • /
    • v.4 no.2
    • /
    • pp.179-181
    • /
    • 1986
  • Computed tomography (CT) adds a new dimension in the study of body contour, organs, and tissues as well as various pathologic conditions. This modality provides a great degree of accuracy in radiation therapy Planning (RTP). However, CT images are usually taken on a small reduced format so that possible errors can be made during inputting the CT data into an automatic planner. Authors have designed a simple inexpensive magnifying device of CT images to obviate errors created by reduced image.

  • PDF

Estimating Organ Doses from Pediatric Cerebral Computed Tomography Using the WAZA-ARI Web-Based Calculator

  • Etani, Reo;Yoshitake, Takayasu;Kai, Michiaki
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.1
    • /
    • pp.1-7
    • /
    • 2021
  • Background: The use of computed tomography (CT) device has increased in the past few decades in Japan. Dose optimization is strongly required in pediatric CT examinations, since there is concern that an unreasonably excessive medical radiation exposure might increase the risk of brain cancer and leukemia. To accelerate the process of dose optimization, continual assessment of the dose levels in actual hospitals and medical facilities is necessary. This study presents organ dose estimation using pediatric cerebral CT scans in the Kyushu region, Japan in 2012 and the web-based calculator, WAZA-ARI (https://waza-ari.nirs.qst.go.jp). Materials and Methods: We collected actual patient information and CT scan parameters from hospitals and medical facilities with more than 200 beds that perform pediatric CT in the Kyushu region, Japan through a questionnaire survey. To estimate the actual organ dose (brain dose, bone marrow dose, thyroid dose, lens dose), we divided the pediatric population into five age groups (0, 1, 5, 10, 15) based on body size, and inputted CT scan parameters into WAZA-ARI. Results and Discussion: Organ doses for each age group were obtained using WAZA-ARI. The brain dose, thyroid dose, and lens dose were the highest in the Age 0 group among the age groups, and the bone marrow and thyroid doses tended to decrease with increasing age groups. All organ doses showed differences among facilities, and this tendency was remarkable in the young group, especially in the Age 0 group. This study confirmed a difference of more than 10-fold in organ doses depending on the facility and CT scan parameters, even when the same CT device was used in the same age group. Conclusion: This study indicated that organ doses varied widely by age group, and also suggested that CT scan parameters are not optimized for children in some hospitals and medical facilities.

Relationship between Incidental Abnormalities on Screening Thoracic Computed Tomography and Mortality: A Long-Term Follow-Up Analysis

  • Jong Eun Lee;Won Gi Jeong;Hyo-Jae Lee;Yun-Hyeon Kim;Kum Ju Chae;Yeon Joo Jeong
    • Korean Journal of Radiology
    • /
    • v.23 no.10
    • /
    • pp.998-1008
    • /
    • 2022
  • Objective: The present study aimed to assess the relationship between incidental abnormalities on thoracic computed tomography (CT) and mortality in a general screening population using a long-term follow-up analysis. Materials and Methods: We retrospectively collected the medical records and CT images of 840 participants (mean age ± standard deviation [SD], 58.5 ± 6.7 years; 564 male) who underwent thoracic CT at a single health promotion center between 2007 and 2010. Two thoracic radiologists independently reviewed all CT images and evaluated any incidental abnormalities (interstitial lung abnormality [ILA], emphysema, coronary artery calcification [CAC], aortic valve [AV] calcification, and pulmonary nodules). Kaplan-Meier analysis with log-rank and z-tests was performed to assess the relationship between incidental CT abnormalities and all-cause mortality in the subsequent follow-up. Cox proportional hazards regression was performed to further identify risk factors of all-cause mortality among the incidental CT abnormalities and clinical factors. Results: Among the 840 participants, 55 (6%), 171 (20%), 288 (34%), 396 (47%), and 97 (11%) had findings of ILA, emphysema, CAC, pulmonary nodule, and AV calcification, respectively, on initial CT. The participants were followed up for a mean period ± SD of 10.9 ± 1.4 years. All incidental CT abnormalities were associated with all-cause mortality in univariable analysis (p < 0.05). However, multivariable analysis further revealed fibrotic ILA as an independent risk factor for all-cause mortality (hazard ratio, 2.52 [95% confidence interval, 1.02-6.22], p = 0.046). ILA were also identified as an independent risk factor for lung cancer or respiratory disease-related deaths. Conclusion: Incidental abnormalities on screening thoracic CT were associated with increased mortality during the long-term follow-up. Among incidental CT abnormalities, fibrotic ILA were independently associated with increased mortality. Appropriate management and surveillance may be required for patients with fibrotic ILA on thoracic CT obtained for general screening purposes.

Semiautomatic Three-Dimensional Threshold-Based Cardiac Computed Tomography Ventricular Volumetry in Repaired Tetralogy of Fallot: Comparison with Cardiac Magnetic Resonance Imaging

  • Hyun Woo Goo
    • Korean Journal of Radiology
    • /
    • v.20 no.1
    • /
    • pp.102-113
    • /
    • 2019
  • Objective: To assess the accuracy and potential bias of computed tomography (CT) ventricular volumetry using semiautomatic three-dimensional (3D) threshold-based segmentation in repaired tetralogy of Fallot, and to compare them to those of two-dimensional (2D) magnetic resonance imaging (MRI). Materials and Methods: This retrospective study evaluated 32 patients with repaired tetralogy of Fallot who had undergone both cardiac CT and MRI within 3 years. For ventricular volumetry, semiautomatic 3D threshold-based segmentation was used in CT, while a manual simplified contouring 2D method was used in MRI. The indexed ventricular volumes were compared between CT and MRI. The indexed ventricular stroke volumes were compared with the indexed arterial stroke volumes measured using phase-contrast MRI. The mean differences and degrees of agreement in the indexed ventricular and stroke volumes were evaluated using Bland-Altman analysis. Results: The indexed end-systolic (ES) volumes showed no significant difference between CT and MRI (p > 0.05), while the indexed end-diastolic (ED) volumes were significantly larger on CT than on MRI (93.6 ± 17.5 mL/m2 vs. 87.3 ± 15.5 mL/m2 for the left ventricle [p < 0.001] and 177.2 ± 39.5 mL/m2 vs. 161.7 ± 33.1 mL/m2 for the right ventricle [p < 0.001], respectively). The mean differences between CT and MRI were smaller for the indexed ES volumes (2.0-2.5 mL/m2) than for the indexed ED volumes (6.3-15.5 mL/m2). CT overestimated the stroke volumes by 14-16%. With phase-contrast MRI as a reference, CT (7.2-14.3 mL/m2) showed greater mean differences in the indexed stroke volumes than did MRI (0.8-3.3 mL/m2; p < 0.005). Conclusion: Compared to 2D MRI, CT ventricular volumetry using semiautomatic 3D threshold-based segmentation provides comparable ES volumes, but overestimates the ED and stroke volumes in patients with repaired tetralogy of Fallot.

Bone height measurements of implant sites : Comparison of panoramic radiography and spiral computed tomography (임플란트 매식부의 고경 평가 : 파노라마 촬영법과 나선형 전산화 단층촬영법의 계측 비교)

  • Cho Bong-Hae
    • Imaging Science in Dentistry
    • /
    • v.32 no.2
    • /
    • pp.61-66
    • /
    • 2002
  • Purpose: To compare the bone height of implant sites measured using panoramic radiography and spiral CT. Materials and Methods : The available bone height was determined for 263 maxillary and mandibular implant sites in 59 patients. Distortion was calculated using the metal bar for the panoramic radiographs. Results: Significant differences in mean bone height between the two imaging modalities were found in maxillary and mandibular anterior regions (p<0.05). The mean difference in bone height recorded by the two techniques was smallest in the maxillary and mandibular molar areas (0.8 mm), and greatest in the mandibular anterior region (1.3 mm). With the exception of the mandibular anterior region, ninety percent of all the sites showed measurement differences within 2 mm. Conclusion: A safety margin of 2 to 3 mm is called for when utilizing panoramic radiography, otherwise additional imaging modality such as computed tomography is necessary to obtain accurate measurements.

  • PDF

Cone-beam computed tomography: Time to move from ALARA to ALADA

  • Jaju, Prashant P.;Jaju, Sushma P.
    • Imaging Science in Dentistry
    • /
    • v.45 no.4
    • /
    • pp.263-265
    • /
    • 2015
  • Cone-beam computed tomography (CBCT) is routinely recommended for dental diagnosis and treatment planning. CBCT exposes patients to less radiation than does conventional CT. Still, lack of proper education among dentists and specialists is resulting in improper referral for CBCT. In addition, aiming to generate high-quality images, operators may increase the radiation dose, which can expose the patient to unnecessary risk. This letter advocates appropriate radiation dosing during CBCT to the benefit of both patients and dentists, and supports moving from the concept of "as low as reasonably achievable" (ALARA) to "as low as diagnostically acceptable" (ALADA).

Analysis of Secondary Battery Based on Image Processing of Computed Tomography (CT 기반 영상처리를 이용한 이차전지의 분석)

  • Jea-Seok Oh;Sang-Yeol Lee;Yoon-Gi Yang;Keun-Ho Rew
    • Journal of Information Technology Applications and Management
    • /
    • v.29 no.6
    • /
    • pp.13-21
    • /
    • 2022
  • In this study, we presented a method to inspect the mechanical defects of 4680 type lithium-ion batteries through image processing method. The raw X-ray images are filtered with CLAHE, then Radon inverse transformations are calculated to reconstruct 3D computed tomography of the battery. Using Haar-cascade, the ROI is targeted automatically, and the template matchings are applied twice. The variations of contrast between template and background show the appropriate values for detecting tabs. It was shown that the proposed algorithm can detect all the tab inside the battery and the distances between tabs. Finally, we successfully found the geometrical defects of battery.

Computer-Aided Diagnosis in Chest CT (흉부 CT에 있어서 컴퓨터 보조 진단)

  • Goo, Jin Mo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.57 no.6
    • /
    • pp.515-521
    • /
    • 2004
  • With the increasing resolution of modern CT scanners, analysis of the larger numbers of images acquired in a lung screening exam or diagnostic study is necessary, which also needs high accuracy and reproducibility. Recent developments in the computerized analysis of medical images are expected to aid radiologists and other healthcare professional in various diagnostic tasks of medical image interpretation. This article is to provide a brief overview of some of computer-aided diagnosis schemes in chest CT.