• Title/Summary/Keyword: computed tomography, CT

검색결과 2,625건 처리시간 0.025초

Application of Dual-Energy Spectral Computed Tomography to Thoracic Oncology Imaging

  • Cherry Kim;Wooil Kim;Sung-Joon Park;Young Hen Lee;Sung Ho Hwang;Hwan Seok Yong;Yu-Whan Oh;Eun-Young Kang;Ki Yeol Lee
    • Korean Journal of Radiology
    • /
    • 제21권7호
    • /
    • pp.838-850
    • /
    • 2020
  • Computed tomography (CT) is an important imaging modality in evaluating thoracic malignancies. The clinical utility of dual-energy spectral computed tomography (DESCT) has recently been realized. DESCT allows for virtual monoenergetic or monochromatic imaging, virtual non-contrast or unenhanced imaging, iodine concentration measurement, and effective atomic number (Zeff map). The application of information gained using this technique in the field of thoracic oncology is important, and therefore many studies have been conducted to explore the use of DESCT in the evaluation and management of thoracic malignancies. Here we summarize and review recent DESCT studies on clinical applications related to thoracic oncology.

외국의 컴퓨터 단층촬영 장치의 방어시설 문헌 조사 (Reviews of Radiation Protection and Shielding for Computed Tomography in Foreign Countries)

  • 장건호;양달모;성동욱;이광용;김혁주
    • 한국의학물리학회지:의학물리
    • /
    • 제19권4호
    • /
    • pp.276-284
    • /
    • 2008
  • 전 세계적으로 컴퓨터 단층 촬영 장치(Computed Tomography, CT)의 임상 적용이 환자의 질병의 조기 진단에 매우 중요하게 사용되고 있으며 사용 빈도 또한 매년 급증하고 있다. 새로운 종류의 CT 장치들이 병변을 조기 진단하기 위하여 개발되고 있다. 이 방사선 발생 장치에 의한 환자나 작업 종사자들의 방사선 피폭이 불가피 할 수도 있다. 국내에서는 CT 장치에 대한 구체적인 방사선 방어나 방사선 시설에 대한 구체적인 규정이 확립되어 있지 않다. 본 논문에서는 국내에서의 CT 사용시설에 대한 방사선 방어 시설과 사용 기준에 대한 규정 마련에 토대를 이루기 위하여 외국에서의 CT 장비에 대한 방사선 방어 및 방사선 차폐에 대한 규정을 조사하였다. 조사방법으로는 구글 검색을 이용한 특정 키워드 검색과 방사선 관련 업무를 수행하는 특정 웹사이트를 직접 검색하는 방법을 사용하였다. 검색결과 캐나다, 미국, 영국 등의 국가에서 국가의 실정에 맞는 가이드라인을 사용하고 있었으나, 아직 이중 에너지 CT에 대한 가이드라인은 없는 것으로 나타났다. 한국에서도 국내 실정에 적합한 CT 장비에서의 방사선 방어, 차폐, 환자나 작업종사자 및 일반인에 대한 방사선 피폭에 대한 가이드라인의 설정이 필요하다고 생각된다.

  • PDF

안와파열골절의 수술결과 평가에서 두 단면의 CT영상 필요성 (Need of Two Planes of CT Scan for Evaluation of Orbital Blowout Fracture Reconstruction)

  • 이수향;범진식;김양우
    • Archives of Plastic Surgery
    • /
    • 제32권2호
    • /
    • pp.194-198
    • /
    • 2005
  • In many reports on the reconstruction of an orbital blowout fracture, CT(computed tomography) imaging has been used for postoperative evaluation. However, in most cases, only one plane of the CT scan was presented, which may not be sufficient for accurate evaluation. This study reviewed the CT scans presented in the related 49 articles (56 cases), and investigated our patients (150 cases) to investigate where were the most frequent unfavorable reconstructions, and to determine which planes should be presented for accurate evaluation. One plane of the CT scan was presented in 70% of the cases. On the other hand, 30% of the cases presented two planes of the CT scans. In our cases, the most prevalent sites for an unfavorable reconstruction were the posterior portion of the inferior wall, and the posterior and the inferior portion of the medial wall. In order to accurately evaluate an orbital wall reconstruction, at least two planes of a CT scan are needed. For an inferior wall evaluation, both the middle and the posterior planes of the coronal section or both the coronal and the sagittal sections are necessary. In addition, for the medial wall evaluation, both the axial and the coronal sections or both the middle and the posterior planes of the coronal section are required.

Neonatal Intracranial Ischemia and Hemorrhage : Role of Cranial Sonography and CT Scanning

  • Khan, Imran Ahmad;Wahab, Shagufta;Khan, Rizwan Ahmad;Ullah, Kkram;Ali, Manazir
    • Journal of Korean Neurosurgical Society
    • /
    • 제47권2호
    • /
    • pp.89-94
    • /
    • 2010
  • Objective : To evaluate the role of cranial sonography and computed tomography in the diagnosis of neonatal intracranial hemorrhage and hypoxic-ischemic injury in an Indian set-up. Methods : The study included 100 neonates who underwent cranial sonography and computed tomography (CT) in the first month of life for suspected intracranial ischemia and hemorrhage. Two observers rated the images for possible intracranial lesions and a kappa statistic for interobserver agreement was calculated. Results : There was no significant difference in the kappa values of CT and ultrasonography (USG) for the diagnosis of germinal matrix hemorrhage/intraventricular hemorrhage (GMH/IVH) and periventricular leucomalacia (PVL) and both showed good interobserver agreement. USG, however detected more cases of GMH/IVH (24 cases) and PVL (19) cases than CT (22 cases and 16 cases of IVH and PVL, respectively). CT had significantly better interobserver agreement for the diagnosis of hypoxic ischemic injury (HII) in term infants and also detected more cases (33) as compared to USG (18). CT also detected 6 cases of extraaxial hemorrhages as compared to 1 detected by USG. Conclusion : USG is better modality for imaging preterm neonates with suspected IVH or PVL. However, USG is unreliable in the imaging of term newborns with suspected HII where CT or magnetic resonance image scan is a better modality.

3차원 X-ray CT 영상을 이용한 화성암 불균질 지수와 역학적 특성과의 상관관계에 대한 연구 (A Study on Correlation between Heterogeneity Index and Mechanical Properties of Igneous Rocks using 3D X-ray Computed Tomography Image)

  • 정연종;김광염;윤태섭
    • 터널과지하공간
    • /
    • 제27권5호
    • /
    • pp.333-342
    • /
    • 2017
  • 본 연구에서는 국내의 다양한 화성암에 대해 내부구조의 불균질성을 정량화하고, 이와 탄성파속도 및 점하중강도간의 상관관계를 분석하였다. 3차원 X-ray Computed Tomography(CT)를 통해 암석 시편 내부 구조에 대한 정보를 획득하였으며, 3차원 영상에 통계적 기법을 적용하여 뷸균질성 대표계수(representative unit length, LR)를 계산하였다. 또한 암석의 탄성파 속도 및 점하중강도와 LR간의 상관관계로부터 암석의 역학적 특성치를 예측하는 추정식을 제안하였다. 본 연구에서 제안한 방법을 통해 3차원 X-ray 영상에 기반한 내부 특성 분석값을 이용해 실내실험을 수행하지 않고도 암석의 역학적 물성을 평가할 수 있는 간접적인 인자를 도출할 수 있는 가능성을 확인하였다.

비수도권(非首都圈) 지역(地域)에서의 전신용(全身用) X선(線) CT의 이용(利用) (Utilization of Body Computed Tomography Scanners in Non-Metropolitan Area)

  • 박영선
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제8권2호
    • /
    • pp.29-45
    • /
    • 1985
  • Computed Tomography Scanner (CT) is highly expensive in operation as well as purchasing. That reason may cause not only to increase the burden of patients but also to waste the capital resources leading to financial difficulties. However the numbers of CT installed throughout the country is increasing, because of efficiency in medical care, patient's concern, competitions among the hospitals within the same area. In the non-Metropolitan area the scanners were expected to be less utilized and less profitable. Nine hospitals equipped with the CT were studied on the utilization of that equipment during the period from November 1984 to February 1985 in non-Metropolitan area and break-even point in one hospital was analyzed for estimating profitabilities. The results were as follows ; 1. Among those nine hospitals, four hospitals had less than 400 beds, which is one of the restrictive minimum standards on the installation of Whole-body Computed Tomography Scanner. 2. The operating time during the normal operation period was longer than those of any other studies, but the accumulated down time was also longer than those of any other studies. The average number of scanning per week for each CT was 45, while the estimated number of for the break-even point was 56.7 cases. 3. When the downtime was excluded in calculating the average operation would be much closer to the cases for the break-even point. Therefore the break-down of the equipment was to be a main cause of the low profitability. 4. The average scanning rate for head area was 33.6%, however three of the nine hospitals showed about 20%. 5. If scanning ratio for the body parts excepting head was increased, the number of scanning for the break-even point would be diminished. 6. The small size hospital especially located near the Metropolitan area showed largest loss in the CT operation. In purchasing the highly expensive equipments in hospitals, demand should be taken into account and planning is recommended.

  • PDF

정상 혈청 크레아티닌을 가진 응급실 환자에서의 조영제 연관 신증 (Nephropathy related to computed tomography in emergency department patients with serum creatinine <1.5 mg/dL)

  • 김종하;박신률;김종근
    • Journal of Yeungnam Medical Science
    • /
    • 제32권2호
    • /
    • pp.90-97
    • /
    • 2015
  • Background: Contrast-induced nephropathy (CIN) can cause serious adverse effects. To reduce the occurrence of CIN related computed tomography (CT) in emergency patients, we assessed the respective roles of serum creatinine (SCr) alone and estimated glomerular filtration rate (eGFR) as an early predictor for CIN related CT. Methods: For patients with SCr <1.5 mg/dL who underwent CT in emergency department (ED) between September 2012 and October 2013, we assessed the prevalence of CIN and its adverse effects. The Modification of Diet in Renal Disease Study (MDRD) and Cockcroft-Gault (CG) formula was used for the calculation of eGFR. Practical calculation was performed by electronic medical record (EMR) system for MDRD and internet calculating service for CG. And we investigated the prevalence of CIN in eGFR $<60mL/min/1.73m^2$ before CT. Results: A total of 1,555 patients were enrolled. The prevalence of CIN after CT was 4.6% and it showed correlation with renal deterioration, increased in-hospital mortality, and prolonged hospitalization. Despite baseline SCr <1.5 mg/dL, among enrolled patients, 11.3% as MDRD equation and 29.5% as CG formula were $<60mL/min/1.73m^2$ and in this condition, the prevalence of CIN was significantly high (odds ratio was 2.87 [1.64-5.02] as MDRD equation and 2.03 [1.26-3.29] as CG formula). Conclusion: Just SCr <1.5mg/dL was not appropriate to recognize preexisting renal insufficiency, but eGFR using MDRD equation was useful in predicting the risk of CIN related CT in ED. Using EMR, calculation of eGFR can be easier and more convenient.

중증외상환자 CT 검사 시 검사보조자의 방사선피폭 경감을 위한 융합적 망토 차폐체의 유용성 연구 (A study on the usefulness of a fusion model designed cloak shield to reduce the radiation exposure of the assistant during CT of severely injured patient)

  • 서선열;한만석;김창규;전민철;김용균;김갑중
    • 한국융합학회논문지
    • /
    • 제8권9호
    • /
    • pp.211-216
    • /
    • 2017
  • 중증외상 환자 CT(Computed Tomography)검사 시 검사 보조자의 방사선 피폭경감을 위하여 새로운 융합적 모델의 망토 차폐체를 제작하여 그 유용성을 평가하고자 한다. 실험 방법으로 뇌혈관 CT 검사와 동일한 조건에서 두부 팬텀과 인체 팬텀을 이용하여 기존 차폐체와 새롭게 개발된 망토 차폐체를 이용하여 심장, 양쪽 액와부 그리고 갑상샘 부위를 유리선량계로 피폭선량을 측정하였다. 새롭게 개발된 차폐체가 기존의 차폐체 보다 방사선 차폐율이 심장 61.9 %, 좌측액와부 46.2 %, 우측액와부 69.8 %, 그리고 갑상샘 71.1 % 로 각각 높게 측정되었다. 새롭게 개발된 망토 차폐체가 방사선 피폭을 감소시키는데 매우 유용하며 향후 새롭게 개발된 융합적 모델의 망토 차폐차가 방사선 피폭을 감소시키는데 있어 큰 기여를 할 것으로 판단된다.

Tc-99m hydroxymethylene diphosphonate scintigraphy, computed tomography, and magnetic resonance imaging of osteonecrosis in the mandible: Osteoradionecrosis versus medication-related osteonecrosis of the jaw

  • Ogura, Ichiro;Sasaki, Yoshihiko;Sue, Mikiko;Oda, Takaaki;Kameta, Ayako;Hayama, Kazuhide
    • Imaging Science in Dentistry
    • /
    • 제49권1호
    • /
    • pp.53-58
    • /
    • 2019
  • Purpose: To present characteristic findings of Tc-99m hydroxymethylene diphosphonate (HMDP) scintigraphy, computed tomography (CT), and magnetic resonance (MR) imaging for osteonecrosis in the mandible, especially osteoradionecrosis(ORN) and medication-related osteonecrosis of the jaw(MRONJ). Materials and Methods: Thirteen patients with MRONJ and 7 patients with ORN in the mandible underwent Tc-99m HMDP scintigraphy, CT, and MR imaging (T1-weighted images[T1WI], T2-weighted images[T2WI], short inversion time inversion recovery images[STIR]), diffusion-weighted images[DWI], and apparent diffusion coefficient [ADC] mapping). The associations of scintigraphy, CT, and MR imaging findings with MRONJ and ORN were analyzed using the chi-square test with the Pearson exact test. Results: Thirteen patients with MRONJ and 7 patients with ORN in the mandible showed low signal intensity on T1WI and ADC mapping, high signal intensity on STIR and DWI, and increased uptake on scintigraphy. Periosteal bone proliferation on CT was observed in 69.2% of patients with MRONJ(9 of 13) versus 14.3% of patients with ORN(1 of 7)(P=0.019). Conclusion: This study presented characteristic imaging findings of MRONJ and ORN on scintigraphy, CT, and MR imaging. Our results suggest that CT can be effective for detecting MRONJ and ORN.

Physiologic Cervical Alignment Change between Cervical Spine X-ray and Computed Tomography

  • Lee, Ho Jin;Kim, Il Sup;Hong, Jae Taek
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권5호
    • /
    • pp.784-790
    • /
    • 2021
  • Objective : The purpose of this study was to investigate the correlations among various radiological parameters used to determine cervical alignment from cervical spine radiographs (X-CS) and cervical spine computed tomography (CT-CS), both within and between modalities. Methods : This study included 168 patients (≤60 years old) without a definite whole spine deformity who underwent CT-CS and X-CS. We measured occipital slope (O-s), C1 slope, C2 slope, C7 slope, sella turcica - C7 sagittal vertical axis (StC7-SVA), spino-cranial angle, T1 slope, and C27-SVA. We calculated the O-C2 angle, O-C7 angle, and C2-7 angle from the measured parameters and conducted correlation analyses among multiple parameters. Results : The intrinsic correlation features among multiple cervical parameters were very similar for both X-CS and CT-CS. The two SVA parameters (C27-SVA and StC7-SVA) were mainly influenced by the upper cervical slope parameters (r=|0.13-0.74|) rather than the lower slope cervical parameters (r=|0.08-0.13|). The correlation between X-CS and CT-CS for each radiological parameter was statistically significant (r=0.26-0.44) except for O-s (r=0.10) and StC7-SVA (r=0.11). Conclusion : The correlation patterns within X-CS and CT-CS were very similar in this study. The correlation between X-ray and CT was statistically significant for most radiological parameters, and the correlation score increased when the horizontal gaze was consistently maintained. The lower cervical parameters were not statistically associated with translation-related parameters (C2-7 SVA and StC7-SVA). Therefore, the upper cervical segment may be a better predictor for determining head and neck translation.