• Title/Summary/Keyword: computed tomographic equipment

Search Result 7, Processing Time 0.022 seconds

Performance Evaluation of Computed Tomographic Equipment (CT장치의 성능평가에 관한 연구)

  • Han Dong Kyoon;Kim Moon Chan;Yang Han Joon;Ko Shin Kwan
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.27 no.2
    • /
    • pp.66-85
    • /
    • 2001
  • In medical equipments as complex as a computed tomographic equipment, routine quality control procedures are essential to the detection of small pathologic change in soft tissue as well as and the maintenance of optimal image quality. This study was condu

  • PDF

A Study on measurement of scattery ray of Computed Tomography (전산화 단층촬영실의 산란선 측정에 대한 연구)

  • Cho, Pyong-Kon;Lee, Joon-Hyup;Kim, Yoon-Sik;Lee, Chang-Yeop
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.37-42
    • /
    • 2003
  • Purpose : Computed tomographic equipment is essential for diagnosis by means of radiation. With passage of time and development of science computed tomographic was developed time and again and in future examination by means of this equipment is expected to increase. In this connection these authors measured rate of scatter ray generation at front of lead glass for patients within control room of computed tomographic equipment room and outside of entrance door for exit and entrance of patients and attempted to ind out method for minimizing exposure to scatter ray. Material and Method : From November 2001 twenty five units of computed tomographic equipments which were already installed and operation by 13 general hospitals and university hospitals in Seoul were subjected to this study. As condition of photographing those recommended by manufacturer for measuring exposure to sauter ray was use. At the time objects used DALI CT Radiation Dose Test Phantom fot Head (${\oint}16\;cm$ Plexglas) and Phantom for Stomache(${\oint}32\;cm$ Plexglas) were used. For measurement of scatter ray Reader (Radiation Monitor Controller Model 2026) and G-M Survey were used to Survey Meter of Radical Corporation, model $20{\times}5-1800$, Electrometer/Ion Chamber, S/N 21740. Spots for measurement of scatter ray included front of lead glass for patients within control room of computed tomographic equipment room which is place where most of work by gradiographic personnel are carried out and is outside of entrance door for exit and entrance of patients and their guardians and at spot 100 cm off from isocenter at the time of scanning the object. The results : Work environment within computed tomography room which was installed and under operation by each hospital showed considerable difference depending on circumstances of pertinent hospitals and status of scatter ray was as follows. 1) From isocenter of computed tomographic equipment to lead glass for patients within control room average distance was 377 cm. At that time scatter ray showed diverse distribution from spot where no presence was detected to spot where about 100 mR/week was detected. But it met requirement of weekly tolerance $2.58{\times}10^{-5}\;C/kg$(100 mR/week). 2) From isocenter of computed tomographic equipment to outside of entrance door where patients and their guardians exit and enter was 439 cm in average, At that time scatter ray showed diverse distribution from spot where almost no presence was detected to spot with different level but in most of cases it satisfied requirement of weekly tolerance of $2.58{\times}10^{-6}\;C/kg$(100 mR/week). 3) At the time of scanning object amount of scatter ray at spot with 100 cm distance from isocenter showed considerable difference depending on equipments. Conclusion : Use of computed tomographic equipment as one for generation of radiation for diagnosis is increasing daily. Compared to other general X-ray photographing field of diagnosis is very high but there is a high possibility of exposure to radiation and scatter ray. To be free from scatter ray at computed tomographic equipment room even by slight degree it is essential to secure sufficient space and more effort should be exerted for development of variety of skills to enable maximum photographic image at minimum cost.

  • PDF

Performance evaluation of computed tomographic equipment in Korea (국내 CT장치의 성능평가에 관한 연구)

  • Yang, Han-Jun;Go, Sin-Gwan;Park, Jun-Cheol
    • Journal of radiological science and technology
    • /
    • v.25 no.2
    • /
    • pp.83-83
    • /
    • 2002
  • 국내 35개 병원의 44대의 CT장치를 대상으로 CT장치의 성능을 크게 7가지의 항목별로 구분하여 평가한 결과는 다음과 같았다. 물의 평균 CT number는 -18.9HU와 +68.6HU의 범위에 속했으며, 전체 장치의 평균은 $2.4{\pm}13.0\;HU$였다. 물의 평균 CT number의 권장수준을 -6과 +6로 하였을 경우 이에 적합한 장치는 35대(79.5%)였다. Contrast scale은 장치의 종류에 따라 많은 차이를 나타내었으나 평균은 $2.02{\pm}10^{-4}{\sim}1.665{\pm}10^{-5}$이었다. 직선성을 나타내는 상관계수는 0.984에서 0.992의 분포를 나타내었으며 평균은 $0.990{\pm}0.002$였다. 공간분해능은 0.60 m에서 1.25 mm의 분포를 나타내었으며 전체 장치의 65.9%에 해당되는 29대에서 0.75 mm의 공간 해상능을 나타내었다. 대조도 분해능은 3.2 mm(1/8인치)에서 19.1 mm(3/4인치)의 분포를 나타내었으며, 대조도 분해능의 권장수준을 6.4 mm 이하로 하였을 경우 측정 대상장치 44대 중 이에 적합한 장치는 37대(84.1%)였다. 슬라이스 두께의 설정치가 1 mm인 경우 측정치의 평균은 $2.0{\pm}0.6\;mm$이였으며, 설정치가 2 mm와 3 mm인 경우 측정치는 각각 $3.0{\pm}0.7\;mm$$3.5{\pm}0.6\;mm$이였다. 설정치가 5 mm와 7 mm인 경우 측정치는 각각 $5.1{\pm}0.6\;mm$, $7.0{\pm}0.5mm$이였다. 그리고 10 mm의 설정치에서는 $9.8{\pm}0.7\;mm$의 측정치를 나타내었다. 위치잡이용 중심선의 좌우방향의 편차는 -4.7 mm에서 +41.7 mm의 범위였으며, 상하방향의 편차는 -3.7 mm에서 +4.6 mm의 범위였다. 위치잡이용 중심선의 좌우 및 상하방향의 권장수준을 ${\pm}3.0\;mm$${\pm}3.0\;mm$ 이하로 하였을 경우 41대의 측정 대상장치에서 이에 적합한 장치는 33대(80.5 %)였다.

  • PDF

Statistical Methods for Tomographic Image Reconstruction in Nuclear Medicine (핵의학 단층영상 재구성을 위한 통계학적 방법)

  • Lee, Soo-Jin
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.2
    • /
    • pp.118-126
    • /
    • 2008
  • Statistical image reconstruction methods have played an important role in emission computed tomography (ECT) since they accurately model the statistical noise associated with gamma-ray projection data. Although the use of statistical methods in clinical practice in early days was of a difficult problem due to high per-iteration costs and large numbers of iterations, with the development of fast algorithms and dramatically improved speed of computers, it is now inevitably becoming more practical. Some statistical methods are indeed commonly available from nuclear medicine equipment suppliers. In this paper, we first describe a mathematical background for statistical reconstruction methods, which includes assumptions underlying the Poisson statistical model, maximum likelihood and maximum a posteriori approaches, and prior models in the context of a Bayesian framework. We then review a recent progress in developing fast iterative algorithms.

Requirements for Cerebrovascular Surgery in Comprehensive Stroke Centers in South Korea

  • Kim, Tackeun;Oh, Chang Wan;Park, Hyeon Seon;Lee, Kunsei;Lee, Won Kyung;Lee, Heeyoung
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.4
    • /
    • pp.478-484
    • /
    • 2018
  • Objective : Cerebrovascular disease (CVD) was the third most common cause of death in South Korea in 2014. Evidence from abroad suggests that comprehensive stroke centers play an important role in improving the mortality rate of stroke. However, surgical treatment for CVD is currently slightly neglected by national policy, and there is still regional imbalance in this regard. For this reason, we conducted a survey on the necessity of, and the requirements for, establishing regional comprehensive cerebrovascular surgery centers (CCVSCs). Methods : This investigation was performed using the questionnaire survey method. The questionnaire was consisted with two sections. The first concerned the respondent's opinion regarding the current status of demand and the regional imbalance of cerebrovascular surgery in South Korea. The second section asked about the requirements for establishing regional CCVSCs. We sent the questionnaire to 100 board members of the Korean Society of Cerebrovascular Surgeons. Results : Most experts agreed that cerebrovascular surgery patients were concentrated in large hospitals in the capital area, and 83.6% of respondents agreed that it was necessary to alleviate the regional imbalance of cerebrovascular surgery. With regards to personnel, over 90% of respondents answered that at least two neuro-vascular surgeons and two neuro-interventionists are necessary to establish a CCVSC. Regarding facilities, almost all respondents stated that each CCVSC would require a neuro-intensive care unit and hybrid operating room. The survey asked the respondents about 13 specific neurovascular surgical procedures and whether they were necessary for a regional CCVSC. In the questions about the necessity of cerebrovascular surgical equipment, all seven pieces of equipment were considered essential by all respondents. A further five pieces of equipment were considered necessary on site: computed tomographic angiography, magnetic resonance angiography, conventional angiography, surgical microscope, and surgical navigation. Our results may provide a basis for future policy regarding treatment of cerebrovascular disease, including surgery. Conclusion : Raising the comprehensiveness of treatment at a regional level would lower the national disease burden. Policies should be drafted regarding comprehensive treatment including surgery for cerebrovascular disease, and related support plans should be implemented.

Analysis of the Entrance Surface Dose (ESD) and Contrast Usage of Trance Femoral Cerebral Angiography (TFCA) and Cerebral Computed Tomographic Angiography (CCTA) for Cerebrovascular Disease Examining (뇌혈관 질환 검사를 위한 뇌혈관 조영술(TFCA)과 뇌혈관 전산화 단층 촬영 검사(CCTA)의 입사표면선량(ESD) 및 조영제 사용량 분석)

  • Seo, Young-Hyun;Hong, Cheon-Gi;Song, Jong-Nam
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.495-502
    • /
    • 2019
  • A typical cerebrovascular disease among cerebrovascular diseases is vascular diseases such as cerebral infarction, cerebral hemorrhage, cerebral aneurysm, cerebrovascular stenosis. If the disease occurs and causes cerebral damage, it may be difficult to recover completely. So that, Must continue to perform health care through examination early. In particular, Because most cerebrovascular disease examining use radiation equipment and Thus this study was to find out how to select about the optimal examining method and X-ray dose decrease method among different examining method though comparison and analysis for the entrance surface dose (ESD) on cerebrovascular examining with Trance Femoral Cerebral angiography (TFCA) and Cerebral Computed Tomographic Angiography (CCTA). Also, want to find out how to select about the optimal examining method for worried patient that contrast medium side effect though measuring and evaluating for contrast usage. Data were collected from 70 patients (43 males and 27 females) who underwent CCTA at Yeosoo region hospital from June 2018 to December 2018 and 61 patients (34 males and 27 females) who underwent TFCA at Pyeongtaek region hospital from June 2018 to November 2018. ESD analysis method collected retrospective data though M-view and PACS PLUS program, Used contrast usage measuring method did reality measuring method. In the analysis using SPSS, the ESD of TFCA was $245.74{\pm}71.91$, which was $32.05{\pm}7.74$ lower than the dose of $277.79{\pm}79.65$ of CCTA ESD, and statistically significant at t = 3.249, p = 0.017 (p<0.05). As a result of the comparison of the total amount of contrast agent, the mean contrast agent used in TFCA was $55.05{\pm}17.68ml$, which was about 14.95 smaller than the amount of contrast agent used in CCTA, and statistically significant t = -4.548, p<0.001. In conclusion, the ESD of TFCA was statistically significantly lower than that of CCTA, and also the used contrast usage was significantly tiny than that of CCTA. Therefore, Select the method to increase the utilization of TFCA for cerebral disease examining, we can consider X-ray dose decrease method at the same time as to decrease side effect of contrast medium.

Introduction of Hindfoot Coronal Alignment View (후족부 관상면 배열 영상에 대한 고안)

  • Moon, Il-Bong;Jeon, Ju-Seob;Yoon, Kang-Cheol;Choi, Nam-Kil;Kim, Seung-Kook
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.225-228
    • /
    • 2006
  • Purpose: Accurate clinical evaluation of the alignment of the calcaneus relative to the tibia in the coronal plane is essential in the evaluation and treatment of hindfoot pathologic condition. Previously described standard anteroposterior, lateral, and oblique radiographic methods of the foot or ankle do not demonstrate alignment of the tibia relation to the calcaneus in the coronal plane. The purpose of this study was to introduce hindfoot coronal alignment view. Material : 1) Both feet were imaged simultaneously on an elevated, radiolucent foot stand equipment. 2) Both feet stood on a radiolucent platform with equal weight on both feet. 3) Both feet are located foot axis longitudinal perpendicular to the platform. 4) Silhouette tracing around both feet are made, and line is then drawn to bisect the silhouette of the second toe and the outline of the heel. 5) The x-ray beam is angled down approximately $15^{\circ} to $20^{\circ} Result : 1) This image described tibial axis and medial, lateral tuberosity of calcaneus. 2) Calcaneus do not rotated. 3) The view is showed by talotibial joint space. Conclusion: Although computed tomographic and magnetic resonance imaging techniques are capable of demonstrating coronal hindfoot alignment, they lack usefulness in most clinical situations because the foot is imaged in a non-weight bearing position. But hindfoot coronal alignment view is obtained for evaluating position changing of inversion, eversion of the hindfoot and varus, valgus deformity of calcaneus.

  • PDF