• 제목/요약/키워드: compressive strength level

검색결과 495건 처리시간 0.028초

A data mining approach to compressive strength of CFRP-confined concrete cylinders

  • Mousavi, S.M.;Alavi, A.H.;Gandomi, A.H.;Esmaeili, M. Arab;Gandomi, M.
    • Structural Engineering and Mechanics
    • /
    • 제36권6호
    • /
    • pp.759-783
    • /
    • 2010
  • In this paper, compressive strength of carbon fiber reinforced polymer (CFRP) confined concrete cylinders is formulated using a hybrid method coupling genetic programming (GP) and simulated annealing (SA), called GP/SA, and a robust variant of GP, namely multi expression programming (MEP). Straightforward GP/SA and MEP-based prediction equations are derived for the compressive strength of CFRP-wrapped concrete cylinders. The models are constructed using two sets of predictor variables. The first set comprises diameter of concrete cylinder, unconfined concrete strength, tensile strength of CFRP laminate, and total thickness of CFRP layer. The most widely used parameters of unconfined concrete strength and ultimate confinement pressure are included in the second set. The models are developed based on the experimental results obtained from the literature. To verify the applicability of the proposed models, they are employed to estimate the compressive strength of parts of test results that were not included in the modeling process. A sensitivity analysis is carried out to determine the contributions of the parameters affecting the compressive strength. For more verification, a parametric study is carried out and the trends of the results are confirmed via some previous studies. The GP/SA and MEP models are able to predict the ultimate compressive strength with an acceptable level of accuracy. The proposed models perform superior than several CFRP confinement models found in the literature. The derived models are particularly valuable for pre-design purposes.

도시철도 지하구조물 압축강도와 반발경도의 상관관계에 관한 연구 (A Study on Correlation between Compressive Strength and Rebound Hardness of Urban Underground Structures)

  • 최정열;이수재;정지승
    • 문화기술의 융합
    • /
    • 제6권4호
    • /
    • pp.655-661
    • /
    • 2020
  • 본 연구에서는 도시철도 지하구조물을 대상으로 동일위치에서의 콘크리트 코어채취 압축강도와 비파괴시험 반발경도를 측정하여 반발경도 범위별 추정식을 도출하고 반발경도 구간별 실측 콘크리트 코어강도와의 비교를 통해 범위에 따른 추정 압축강도의 적정성을 확인하였다. 연구결과, 가우시안 확률밀도 함수를 이용하여 산출한 반발경도 범위별 평균 압축강도의 선형회귀분석 결과(대표 압축강도 추정식)와 반발경도 범위별 추정식은 실측 콘크리트 코어압축강도 실험결과와 약 3% 이내로 잘 일치하는 것으로 나타났다. 본 연구의 반발경도 범위별 압축강도 추정결과는 추정 압축강도의 오차를 줄이고 높은 신뢰수준을 확보할 수 있을 것으로 분석되었다. 따라서 본 연구에서 제안한 반발경도 측정결과를 이용한 확률적 통계분석결과는 추정식에 따라 상대적으로 편차가 크게 나타나는 반발경도와 콘크리트 압축강도간의 상관관계의 신뢰수준을 확보하는 데에 도움이 될 수 있을 것으로 판단된다.

재생 폐콘크리트의 성능향상에 관한 연구 (Improving Performance of Recycled Waste Concrete)

  • 이봉학;김광우;박제선;김진영
    • 콘크리트학회지
    • /
    • 제7권2호
    • /
    • pp.136-145
    • /
    • 1995
  • 본 연구는 천연 굵은 골재 50%를 재생골재로 대치시켜 제조한 재생콘크리트를 일반 구조물에 사용할 수 있도록 성능을 향상시키기 위한 연구의 일환으로 수행되었다. 쇄석골재 사용시의 배합설계 방법으로 콘크리트를 제조하였고 일반적인 수중양생으로 공시체를 야생하였다. 재생콘크리트의 성능향상을 목적으로 유동화제와 플라이애쉬를 첨가하였다. 압축강도 등 각종 강도와 파괴인성 등을 측정하여 이를 일반콘크리트와 비교한 결과 재생콘크리트는 강도와 탄성계수가 낮고 변형율이 크며 파괴인성도 낮았다. 그러나 유동화제의 사용으로 물-시멘트비를 35%까지 낮추므로써 슬럼프 $16{\pm}2$cm에서 일반 구조물에 소요 압축강도보다 높은$225kg/cm^2$이상의 압축강도를 얻었다. 하지만 재생콘크리트를 일반 구조물에 사용을 위해서는 탄성계수와 변형율에 대한 향상이 필요하다. 또한 플라이애쉬의 사용은 장기 강도 증진 효과를 보이는 반면 강도 저하를 유발했다.

Reliability based partial safety factor of concrete containing nano silica and silica fume

  • Nanda, Anil Kumar;Bansal, Prem Pal;Kumar, Maneek
    • Computers and Concrete
    • /
    • 제26권5호
    • /
    • pp.385-395
    • /
    • 2020
  • The influence of combination of nano silica and silica fume, as partial cement replacement materials, on the properties of concrete has been studied through the measurement of compressive strength. The compressive strength of concrete in terms of mean, standard deviation and with-in-test coefficient of variation related to the variation in the nominated parameters have also been developed. The compressive strength data developed experimentally has been analyzed using normal-probability distribution and partial safety factors of composite concretes have been evaluated by using first order second moment approach with Hasofer Lind's method. The use of Nano silica and silica fume in concrete decreases the partial safety factor of concrete i.e., increase the reliability of concrete. The experimental results show that the properties of concrete having nano silica and silica fume in combination were better than that of a plain concrete. The SEM test results showing the level of Ca(OH)2 in plain concrete and consumption level Ca(OH)2 of concrete containing nano silica & silica fume have also been presented.

복합열화 환경을 받는 콘크리트 시설물을 위한 보수용 폴리머 시멘트 복합체의 내구성능 향상에 관한 연구 (Enhanced Durability Performance of Polymer Modified Cement Composites for Concrete Repair Under Combined Aging Conditions)

  • 원종필;박찬기
    • 한국농공학회논문집
    • /
    • 제47권6호
    • /
    • pp.27-34
    • /
    • 2005
  • The purpose of this study is to improve the durability performance of polymer modified cement composites for repair of concrete under combined aging conditions. The experimental procedure was divided into three parts. First, the replacement level of mineral admixtures in polymer modified cement composites were determined in an experimental study based on a Box Behnken design. Second, the flow value, compressive strength and chloride permeability test of sixteen types of mixtures were conducted. Test results show that the polymer modified cement composites were effected on the improvement of the compressive strength and permeability performance. Third, the effects on the replacement level of silica fume mixture was evaluated by the compressive strength, chloride permeability, chemical resistance and repeated freezing and thawing cycles test. They demonstrated that the polymer modified cement composites using mixture of silica fume, fly ash, and blast furnace slag improved the durability performance.

양생수에 따른 수중불분리콘크리트의 압축강도특성에 관한 실험적 연구 (An Experimental Study on the Characteristics of Compressive Strength of Antiwashout Underwater Concrete with Curing Water)

  • 윤재범;고창섭;김명식;장희석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.135-138
    • /
    • 1999
  • The objective of this study is to investigate the compressive strength property of antiwashout underwater concrete with curing water through experimental researches. Type of casting and curing water(fresh water, sea water) are used as main experimental parameter, additionally a few variables affecting compressive strength property are used ; water-cement ratio (45%, 48%, 50%, 52%, 55%), and unit weight of admixtures (antiwashout underwater agent ; 0.6%, 0.8%, 1.0%, 1.2%, 1.4% of unit weight of water, superplasticizer ; 0.5%, 1.0%, 1.5%, 2.0%, 2.5% of unit weight of cement)) Compressive strength level of antiwashout underwater concrete which was cast and cured in fresh water is higher than other one. Consequently, incremental modulus has to increase when the antiwashout underwater concrete is made use of underwater work from ocean.

  • PDF

경량골재의 표면처리에 따른 콘크리트의 탄산화 저항성에 관한 실험적 연구 (An Experimental Study on Carbonation Resistance of Concrete Depending on Surface Treatment of Lightweight Aggregates)

  • 엄인혁;온재훈;김영수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.89-91
    • /
    • 2012
  • The purpose of this study is to investigate the mechanical property and carbonation resistance of concretes using surface treated lightweight aggregate. In order to evaluate mechanical property and carbonation resistance, slump, compressive strength, and carbonation depth are tested. Slump of concretes using surface treated lightweight aggregate measured 120~125mm, which are lower than slump of NWAC. Compared to compressive strength of NWAC, compressive strength of concretes using surface treated lightweight aggregate showed a level of 82.8~95.9%. In carbonation resistance test, carbonation depth of concretes using surface treated lightweight aggregate measured 10.2~11.3mm, which are lower than carbonation depth of NWAC. As a result, it is found that compressive strength is decreased slightly but carbonation resistance is improved, in case of using surface treated lightweight aggregate.

  • PDF

콘크리트 초기 품질관리를 위한 CIMS의 개발성능 Test (Performance test of Concrete IoT Management System for concrete early-age quality control)

  • 이영준;최윤호;서항구;현승용;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.161-162
    • /
    • 2019
  • The aim of the research is analyzing the performance of the concrete IoT management system invented with similar technique from 'G' company to certify the performance of CIMS. As a results, the compressive strength assessing performance was compared. Since both systems assess concrete compressive strength with maturity method based on measured concrete temperature, both systems measured concrete temperature similarly, and maturity was calculated similarly. Therefore, the assumed compressive strength values were similar for both systems. Therefore, through the test, compressive strength assessing performance of CIMS was considered as a similar level of the 'G' company's system. Furthermore, it is considered that the CIMS has an additional advantage of reusability, adding capability of additional sensor, and wider range of Bluetooth communication.

  • PDF

Effect of temperature on the behavior of self-compacting concretes and their durability

  • Salhi, M.;Li, A.;Ghrici, M.;Bliard, C.
    • Advances in concrete construction
    • /
    • 제7권4호
    • /
    • pp.277-288
    • /
    • 2019
  • The formulation of self-compacting concretes (SCC) and the study of their properties at the laboratory level were currently well mastered. The aim of this work is to characterize SCC under hot climatic conditions and their effects on the properties of fresh and hardened SCC. Particularly, the effect of the initial wet curing time on the mechanical behavior such as the compressive strength and the durability of the SCCs (acid and sulfate attack) as well as the microstructure of SCCs mixtures. In this study, we used two types of cement, Portland cement and slag cement, three water/binder (W/B) ratio (0.32, 0.38 and 0.44) and five curing modes. The obtained results shows that the compressive strength is strongly influenced by the curing methods, 7-days of curing in the water and then followed by a maturing in a hot climate was the optimal duration for the development of a better compressive strength, regardless of the type of binder and the W/B ratio.

Utilisation of glass powder in high strength copper slag concrete

  • Zaidi, Kaleem A.;Ram, Shobha;Gautam, Mukesh K.
    • Advances in concrete construction
    • /
    • 제5권1호
    • /
    • pp.65-74
    • /
    • 2017
  • This study was focused on the use of partial replacement of cement with glass powder in high strength concrete and also copper slag as a partial replacement of coarse sand in concrete. The high strength concrete was prepared with different mineral admixtures like silica fume, fly ash and rice ash husk in different proportions. An experimental investigation has been carried to study about the effect of glass powder on high strength copper slag concrete. The range of glass powder was 10%, 15% and 20% as a replacement of cement. The range of copper slag was 0%, 20%, 40% and 60% as a replacement of natural sand. In addition to the different percentage of fly ash, silica fume, and rice husk ash 5% and 10% was also studied in copper slag concrete. Thus, a total of 51 cubes were casted and compressive strength test was performed on them. The result of the study shows that the value of average compressive strength of concrete after addition of 10%, 15% and 20% of glass powder are 70.47, 72.01 and 73.31 respectively. The value of average compressive strength after addition of 20%, 40% and 60% copper slag as a replacement of sand are 72.18, 74.38 and 73.08 respectively. The value of average compressive strength after addition of 5% and 10% fly ash as a replacement of cement are 71.56 and 73.22. The value of average compressive strength after addition of 5% and 10% silica fume as a replacement of cement are 72.33 and 73.53. The value of average compressive strength after addition of 5% and 10% rice husk ash as a replacement of cement are 72.86 and 69.49. At the level of 20% replacement of cement by glass powder meets maximum strength as compared to that of controlled concrete and copper slag high strength concrete.