• Title/Summary/Keyword: compression fracture

Search Result 581, Processing Time 0.023 seconds

Impact Damge and Residual Bending Strength of CFRP Composite Laminates Subjected to Impact Loading Fracture Mechanism and Impact Damage of Orthotropy Laminated Plates (충격하중을 받는 CFRP 적층판의 충격손상과 굽힘 잔류강도 직교 이방성 적층판의 충격손상과 파과메카니즘)

  • 심재기;양인영;오택열
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.11
    • /
    • pp.2752-2761
    • /
    • 1993
  • The purpose of this study is to confirm the decreasing problems of residual bending strength, and the fracture machanism experimentally when CFRP composite laminates are subjected to Foreign Object Damage. Composite laminates used for this experiment are CFRP orthotropy laminated plates, which have two-interfaces [O/sub 6//sup o//90/sub 6//sup o/]sub sym/ and four-interfaces [O/sub 3//sup o//90/sub 6//sup o//O/sub 3//sup o]/sub sym/. When the specimen is subjected to transverse impact by a steel ball, the delamination area generated by impact damage is observed by using SAM(Scanning Acoustic Microscope). also, Thefracture surfaces obtained by three-point bending test were observed by using SEM (Scanning Electron Microscope). Then, fracture mechanism was investigated based on the observed delamination area and fracture surface. The results were summarized as follows; (1) It is found that for the specimen with more interface, the critical delamination energy is increased while delamination-development energy is decreased. (2) Residual bending strength of specimen A is greater than that of Specimen B within the impact range of impact energy 1. 65J (impacted-side compression) and 1. 45J (impacted-side tension). On the other hand, when the impact energy is beyond the above ranges, residual bending strength of specimen A is smaller than that of specimen B. (3) In specimen A and B, residual strength of CFRP plates subjected to impact damage is lower in the impacted-side compression than in the impacted-side tension. (4) In the case of impacted-side compression, fracture is propagated from the transverse crack generat-ed near impact point. On the other hand, fracture is developed toward the impact point from the edge of interface-B delamination in the case of impacted-side tension.

Refracture after locking compression plate removal in displaced midshaft clavicle fractures after bony union: a retrospective study

  • Park, Ho-Youn;Kim, Seok-Jung;Sur, Yoo-Joon;Jung, Jae-Woong;Kong, Chae-Gwan
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.2
    • /
    • pp.72-79
    • /
    • 2021
  • Background: A midshaft clavicle fracture is a common fracture that typically responds well to open reduction and internal fixation (ORIF). However, refracture can occur after implant removal (IR). This study aimed to analyze the rate of refracture and related factors after removal of the locking compression plate (LCP) for displaced midshaft clavicle fractures. Methods: We retrospectively reviewed the medical records of 201 patients who had undergone ORIF with LCP for midshaft clavicle fractures after IR after bony union from January 2011 to May 2018 at our institute. We evaluated basic demographic characteristics and radiographic parameters. All patients were treated with an LCP for primary fracture. The patients were divided into two groups: a refracture group that experienced a second fracture within 1 year after IR and a no-fracture group. Results: There were four cases (1.99%) of refracture; three were treated conservatively, while one was treated surgically. All patients achieved bony union. The average interval between refracture and IR was 64 days (range, 6-210 days). There was a significant difference in classification of fractures (AO Foundation/Orthopaedic Trauma Association [AO/OTA] classification) between the two groups. However, other patient demographics and radiographic measurements between refracture and IR, such as bone diameter, showed no significant difference between the two groups. Conclusions: This study showed that one in 50 patients suffered from refracture after removal of the LCP. Thus, if patients desire IR, the surgeon should explain that there is a relatively higher possibility of refracture for cases with simple or segmental fractures than for other types of fracture.

Vertebral Compression Fractures: Distinction Between Benign and Malignant Causes with Tc-99m Labeled Antigranulocyte Antibody Immunoscintigraphy (Tc-99m 표지 항과립구항체 면역신티그라피(Tc-99m labeled antigranulocyte antibody immunoscintigraphy)를 이용한 척추압박골절의 원인질환 감별)

  • Cho, Ihn-Ho;Lee, Hyong-Woo;An, Sang-Ho;Won, Kyu-Chang;Bae, Jang-Ho;Cho, Soo-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.15 no.2
    • /
    • pp.254-262
    • /
    • 1998
  • We evaluated the effectiveness of Tc-99m labeled antigranulocyte antibody immunoscintigraphy in differentiating the causes of vertebral compression fracture. This study involved 16 patients with vertebral compression fracture; 8 were due to trauma or osteoporosis, 3 were due to metastasis and 5 were due to tuberculous spondylitis. We retrospectively analyzed the location and the extent of decreased tracer uptake in tomographic images of Tc-99m labeled antigranulocyte antibody immunoscintigraphy. Eight patients had a 16 vertebral compression fractures due to trauma or osteoporosis, three patients had 3 vertebral compression fractures due to metastasis and 5 patients had 6 vertebral compression fractures due to tuberculous spondylitis. Sixteen vertebral compression fractures by trauma or osteoporosis showed a normal tracer uptake in pedicle, laminar and spinous process, but there was noted with 6 decreased uptake, 8 absence of tracer uptake and 2 normal tracer uptake in the vertebral body. Two vertebral compression fractures by metastasis showed the absence of uptake in vertebral body, pedicle, laminar and spinous process, and one showed an absence of vertebral body and spinous process. Six vertebral compression fractures by tuberculous spondylitis showed the absence of uptake in six compression fractures, the absence of pedicle in five compression fractures. We concluded Tc-99m labeled antigranulocyte antibody immunoscintigraphy may be helpful to differentiate the causes of vertebral compression fractures.

  • PDF

Korean Medicine for Thoracolumbar Compression Fracture in Korean Literature : a Systematic Review (흉요추 압박 골절의 한의학적 치료에 대한 국내 임상 근거 : 체계적 문헌 고찰)

  • Bae, Ji Min;Kim, Dae Hun;Kim, Jae Kyu;Lee, Byung Ryul;Yang, Gi Young;Kim, Kun Hyung
    • Journal of Acupuncture Research
    • /
    • v.32 no.4
    • /
    • pp.147-156
    • /
    • 2015
  • Objectives : This study aims to evaluate the effectiveness and safety of Korean medicine for a thoracolumbar compression fracture. Methods : We searched six Korean databases (DBPIA, Korean Studies Information Service System, Oriental Medicine Advanced Searching Integrated System, National Digital Science Library, Research Information Sharing Service, KoreaMed) (up to June 2015) and the Journal of Korean Acupuncture and Moxibustion Society. Unpublished studies were also searched. Clinical research, other than case reports involving less than 10 patients, were eligible. The effectiveness and safety of Korean Medicine was analyzed. The 'Risk of Bias' was assessed using the 'Risk of Bias' assessment tool for non-randomized studies as well as the Cochrane Collaboration's 'Risk of Bias' tool. Results : We found 12 before-after studies (374 patients). There was no randomized trial. All studies combined at least three different types of Korean medicine treatments. The period of treatment varied between less a week and 154 days. All the included studies reported improvements in pain, functional disability related to lower back pain, global assessment, and benefits in the compression ratio of a fractured vertebrae and skin temperature measured by digital infrared thermal imaging in comparison with the baseline. However, all studies had a high risk of bias and three studies reported mild adverse events. Conclusions : There is no randomized trial for the role of Korean medicine for patients with a thoracolumbar compression fracture. The effectiveness and safety of Korean medicine for this population remains unclear. Findings in this review are seriously biased due to observational design and a high risk of bias included in the studies. Future high-quality randomized trials are warranted.

The Clinical Study on Hua-Tuo-Jia-Ji-Xue(華佗夾脊穴) Acupuncture Treatment of Patient with Thoracolumbar Compression Fracture (흉(胸)·요추압박골절(腰椎壓迫骨折) 환자(患者)의 화타협척혈 침치료(鍼治療)에 대한 임상적 고찰)

  • Song, Won-sub;Hwang, Jae-Yeon;Shin, Young-Il;Lee, Byung-Ryul
    • Journal of Acupuncture Research
    • /
    • v.18 no.4
    • /
    • pp.55-67
    • /
    • 2001
  • Objective : This study was performed to evaluate result of thoracolumbar compression fracture patient treated with Hua-Tuo-Jia-Ji-Xue(華佗夾脊穴) acupuncture. Methods : This clinical study was carried out 50 cases with thoracolumbar compression fracture, who had been admitted from January, 2000 to February, 2001, in the department of acupuncture and moxibustion, Hanseo University Oriental Medical Hospital. We divided two groups; A group, without using Hua-Tuo-Jia-Ji-Xue(華佗夾脊穴) acupuncture and the other group is B group, by using Hua-Tuo-Jia-Ji-Xue(華佗夾脊穴) acupuncture. Results : 1. The distribution of sex and age, 78% were female, and 84% were most above there sixties. 2. In the duration of symptom, the largest group was over 4 weeks. 3. In the distribution of cause, the largest group was "lifting heavy object"(32%) and the next was "slip down"(26%). 4. In the distribution of injured level was L1 body the most(19.6%) and T12 body was the next. 5. In the distribution of clinical symptoms on the admission, the largest group was lumbosacral pain(18%). 6. The result of treatment due to the duration of admission, 17case(34%) was the most above "Fair" during the 2~3 weeks. 7. The result of treatment, Good and Fair were the same in 24case(48%). 8. The duration of treatment was longer in high grade of clinical symptom. 9. B group discharged above good state 60% higher than A group.

  • PDF

Study of the Plating Methods in the Experimental Model of Mandibular Subcondyle Fracture (하악골 과두하부 골절 실험모델에서 견고정을 위한 플레이트 고정방법 연구)

  • Lee, Won;Kang, Dong Hee
    • Archives of Craniofacial Surgery
    • /
    • v.12 no.1
    • /
    • pp.12-16
    • /
    • 2011
  • Purpose: This study examined the biomechanical stability of four different plating techniques in the experimental model of mandibular subcondyle fracture. Methods: Twenty standardized bovine tibia bone samples ($7{\times}1.5{\times}1.0cm$) were used for this study. Each of the four sets of tibia bone was cut to mimic a perpendicular subcondyle fracture in the center area. The osteotomized tibia bone was fixed using one of four different fixation groups (A,B,C,D). The fixation systems included single 2.0 mm 4 hole mini adaption plate (A), single 2.0 mm 4 hole dynamic compression miniplate (B), double fixation with 2.0 mm 4 hole mini adaption plate (C), double fixation with a 2.0 mm 4 hole mini adaption plate and 2.0 mm 4 hole dynamic compression miniplate (D). A bending force was applied to the experimental model using a pressure machine (858 table top system, $MTS^{(R)}$) until failure occurred. The load for permanent deformation, maximum load of failure were measured in the load displacement curve with the chart recorder. Results: Double fixation with a 2.0 mm 4 hole mini adaption plate and a 2.0 mm 4 hole dynamic compression miniplate (D) applied to the anterior and posterior regions of the subcondyle experimental model showed the highest load to failure. Conclusion: From this study, double fixation with an adaption plate and dynamic compression miniplate fixation technique produced the greatest biomechanical stability. This technique may be considered a useful means of fixation to reduce the postoperative internal maxillary fixation period and achieve early mobility of the jaw.

Observation of Mechanical Strength of Materials for Dog Dental Prosthesis Production (중형견(犬) 치과 보철물 제작을 위한 소재의 기계적 강도 관찰)

  • Park, Yujin;Choi, Sungmin
    • Journal of Technologic Dentistry
    • /
    • v.41 no.2
    • /
    • pp.93-100
    • /
    • 2019
  • Purpose: This study is making a dog dental prosthesis using digital dental technology. The mechanical strength of the prosthetic material was observed in terms of compressive strength and fracture pattern. Methods: The experiment was performed using dog mandibular molars. The teeth were scanned and modeled. The specimens were made of zirconia, PMMA and Ni-Cr. The specimens were subjected to a vertical compression test with an artificial cancellous bone in UTM tester. Vertical compressive strength and fracture behavior of specimen were observed. Results: The result of observing the compressive load between specimen and artificial bone were $184.8{\pm}5.7N$ in the zirconia specimen, $185.6{\pm}8.9N$ in the PMMA specimen, and $184.4{\pm}4.0N$ in the Ni-Cr alloy specimen. Compression marks of artificial bones were observed. The fracture strength of specimen was observed. The fracture strength of the zirconia specimen was an average of 1,381.4N. The fracture strength of the PMMA specimen was an average of 572.2N. Conclusion: The crown made of three kinds(zirconia, PMMA, Ni-Cr alloy) of materials has the strength to chew about the artificial bone. zirconia and PMMA have vertical compressive strength applicable to medium dog dental prosthetic materials.

Lumbar Compression Fracture Following Snowboard Injury - Case Report - (스노우 보드 손상에 의한 요추 압박 골절 - 증례 보고 -)

  • Chung, Kook-Jin;Chung, Yung-Khee;Noh, Kyu-Cheol;Hong, Sung-Koo;Yoo, Jung-Han
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.4 no.2
    • /
    • pp.128-132
    • /
    • 2005
  • With the introduction of working 5 days a week, people who are participating in sports activity has been increased so rapidly, therefore sports related injuries also has continued to grow. Among winter sports, snowboard has been gaining popularity among adolescents and young adults. But, snowboard related injuries, especially spinal injuries, has been rarely documented. We report a case of lumbar compression fracture following snowboard injury.

  • PDF

Closed-die Compaction of AZO Powder for FE Simulation of Powder Compaction (압분공정의 유한요소 해석을 위한 AZO 분말의 Closed-die Compaction 실험)

  • Kim, Y.B.;Lee, J.S.;Lee, S.M.;Park, H.J.;Lee, G.A.
    • Transactions of Materials Processing
    • /
    • v.21 no.4
    • /
    • pp.228-233
    • /
    • 2012
  • In this study, powder compaction of AZO (alumina doped zinc oxide) powder was performed with a MTS 810 test system using a cylindrical die having a diameter of 10mm. Pressure-density curves were measured based on the load cell and displacement of the punch. The AZO powder compacts with various densities were formed to investigate the mechanical properties such as fracture stress of the AZO powder as a function of the compact density. Two types of compression tests were conducted in order to estimate the fracture stress using different loading paths: a diameteral compression test and a uniaxial compression test. The pressure-density curves of the AZO powder were obtained and the fracture stress of the compacted powders with various densities was estimated. The results show that the compact pressure dramatically increases as the density increases. Based on the experimental results, calibration of the modified Drucker-Prager/Cap model of the AZO powder for use in FE simulations was developed.

A Study on the Production of Carbon Fiber Composites using Injection-molding Grade Thermoplastic Pellets (사출성형용 열가소성 펠렛을 이용한 탄소섬유 복합소재 제작에 관한 연구)

  • Jeong, E.C.;Yoon, K.H.;Kim, J.S.;Lee, S.H.
    • Transactions of Materials Processing
    • /
    • v.25 no.6
    • /
    • pp.402-408
    • /
    • 2016
  • A manufacturing technology of carbon fiber composites with thermoplastic polymer pellets and continuous woven fiber was investigated using a compression molding process. To secure the impregnation of resin into the porosity of fabric the composite specimens were prepared with general injection-molding grade polypropylene pellets and low viscosity polycarbonate pellets. Tensile tests of polypropylene and polycarbonate composites were performed. Polycarbonate composites showed higher fracture strength than that of polypropylene composites because of the difference of matrix properties. However, the increase rate of strength was lower than that of polypropylene composites due to the difference of coherence between matrix and reinforcement. To investigate the effect of carbon fiber volume fraction on the fracture strength variation polypropylene composites with different volume fraction were compression molded and tensile tests were performed together. It was shown that the fracture strength of the polypropylene composites increased by 3.2, 5.4 and 6.9 times with the increase of carbon fabric volume fraction of 0.256, 0.367, and 0.480, respectively.