• 제목/요약/키워드: composite data point

검색결과 124건 처리시간 0.025초

An analytical approach of behavior change for concrete dam by panel data model

  • Gu, Hao;Yang, Meng;Gu, Chongshi;Cao, Wenhan;Huang, Xiaofei;Su, Huaizhi
    • Steel and Composite Structures
    • /
    • 제36권5호
    • /
    • pp.521-531
    • /
    • 2020
  • The behavior variation of concrete dam is investigated, based on a new method for analyzing the data model of concrete dam in service process for the limitation of wavelet transform for solving concrete dam service process model. The study takes into account the time and position of behavior change during the process of concrete dam service. There is no dependence on the effect quantity for overcoming the shortcomings of the traditional identification method. The panel data model is firstly proposed for analyzing the behavior change of composite concrete dam. The change-point theory is used to identify whether the behavior of concrete dams changes during service. The phase space reconstruction technique is used to reconstruct the phase plane of the trend effect component. The time dimension method is used to solve the construction of multi-transformation model of composite panel data. An existing 76.3-m-high dam is used to investigate some key issues on the behavior change. Emphasis is placed on conversion time and location for three time periods consistent with the practical analysis report for evaluating the validity of the analysis method of the behavior variation of concrete dams presented in this paper.

유전기법을 이용한 복합재료 기지재의 경화 모니터링 (Cure monitoring of a composite matrix by dielectrometry)

  • 여권주;이상관;엄문광;황병선
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2001년도 춘계학술발표대회 논문집
    • /
    • pp.110-113
    • /
    • 2001
  • Dielectrometry has been used to monitor the cure of epoxy resin using composite matrix. In this investigation, physical properties of the mixture of epoxy resin(LY564), bisphenol A type, and cycloaliphatic hardener(HY 2954) were observed. Activation energy at maximum tan $\delta$ and gelation point was determined during isothermal scanning. From IonViscosity data, it was found that vitrification peak after gelation was appeared on slow heating rate. It was also measured that the duration time for full cure was necessary and it was about 24 hr at $145^{\circ}C$. Therefore, epoxy resin used in this research is required the extended time for full cure.

  • PDF

클린룸에서 FFU의 합성소음 예측에 관한 연구 (A Study on the Estimation of Composite Noise in Clean room)

  • 이현남;홍동표;조상준;문인호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.231-235
    • /
    • 2005
  • Recently, some semiconductor and LCD manufacturers require equipment suppliers to serve the data of composite noise for clean room. In this study, we evaluate the composite noise of clean room by numerically and experimentally. The value of experimental result is more higher than calculated one as much as 1$\sim$2dB(A).

  • PDF

A Novel Approach for Well-Test Analysis of Volatile Oil Reservoirs in Two-Phase Flow Conditions

  • Baniasadi, Hamid;Rashidi, Fariborz
    • Korean Chemical Engineering Research
    • /
    • 제57권6호
    • /
    • pp.883-890
    • /
    • 2019
  • Two-phase flow near the wellbore in volatile oil reservoirs causes complications in well test analysis. In this study, the flow behavior of volatile oil reservoirs below the bubble-point pressure and the potential of radial composite model for interpretation of two-phase well test in volatile oil reservoirs was investigated. A radial composite model was used for two-phase well test analysis. A new procedure was developed to interpret well test data and estimate the radius of the two-phase region. The changes in fluid composition near the wellbore during drawdown test were found to increase the saturation pressure, which affects the saturation profile during build-up. Well test results showed that the radial composite method is a powerful tool for well test characterization and estimation of reservoir parameters. The proposed procedure was able to estimate the reservoir parameters and radius of the two-phase region with acceptable accuracy.

The extension of the largest generalized-eigenvalue based distance metric Dij1) in arbitrary feature spaces to classify composite data points

  • Daoud, Mosaab
    • Genomics & Informatics
    • /
    • 제17권4호
    • /
    • pp.39.1-39.20
    • /
    • 2019
  • Analyzing patterns in data points embedded in linear and non-linear feature spaces is considered as one of the common research problems among different research areas, for example: data mining, machine learning, pattern recognition, and multivariate analysis. In this paper, data points are heterogeneous sets of biosequences (composite data points). A composite data point is a set of ordinary data points (e.g., set of feature vectors). We theoretically extend the derivation of the largest generalized eigenvalue-based distance metric Dij1) in any linear and non-linear feature spaces. We prove that Dij1) is a metric under any linear and non-linear feature transformation function. We show the sufficiency and efficiency of using the decision rule $\bar{{\delta}}_{{\Xi}i}$(i.e., mean of Dij1)) in classification of heterogeneous sets of biosequences compared with the decision rules min𝚵iand median𝚵i. We analyze the impact of linear and non-linear transformation functions on classifying/clustering collections of heterogeneous sets of biosequences. The impact of the length of a sequence in a heterogeneous sequence-set generated by simulation on the classification and clustering results in linear and non-linear feature spaces is empirically shown in this paper. We propose a new concept: the limiting dispersion map of the existing clusters in heterogeneous sets of biosequences embedded in linear and nonlinear feature spaces, which is based on the limiting distribution of nucleotide compositions estimated from real data sets. Finally, the empirical conclusions and the scientific evidences are deduced from the experiments to support the theoretical side stated in this paper.

초탄성 복합재의 평균장 균질화 데이터 기반 멀티스케일 해석 (A Data-driven Multiscale Analysis for Hyperelastic Composite Materials Based on the Mean-field Homogenization Method)

  • 김수한;이원주;신현성
    • Composites Research
    • /
    • 제36권5호
    • /
    • pp.329-334
    • /
    • 2023
  • 기존의 멀티스케일 유한요소법(Multiscale finite element, FE2 )은 거시 스케일의 모든 적분점에서 대표 체적요소(representative volume element, RVE)의 미시 경계치 문제를 반복적으로 계산하기 때문에 긴 해석 시간과 많은 데이터 저장 공간을 필요로 한다. 이를 해결하기 위해 본 연구에서 평균장 균질화 데이터 기반 멀티스케일 해석 기법을 개발하였다. 데이터 기반 전산역학(data-driven computational mechanics, DDCM) 해석은 변형률-응력 데이터 셋을 직접적으로 사용하는 모델-프리(model-free)접근 방식이다. 멀티스케일 해석을 수행하기 위해, 평균장 균질화(mean-field homogenization)를 활용하여 복합재의 미세구조에 대한 변형률-응력 데이터베이스(database)를 효율적으로 구축하고, 이를 기반으로 데이터 기반 전산역학 시뮬레이션을 수행하였다. 본 논문에서는 개발한 멀티 스케일 해석 프레임워크(framework)를 예제에 적용하여, 초탄성(hyperelasticity) 복합재의 미세 구조를 고려한 데이터 기반 전산역학 시뮬레이션 결과를 확인하였다. 따라서, 데이터 기반 전산역학 접근 방식을 활용한 멀티스케일 해석기법은 다양한 재료 및 구조에 적용될 수 있으며, 멀티스케일 해석 연구 및 응용 가능성을 열어줄 것으로 기대된다.

Evaluation of multi-lane transverse reduction factor under random vehicle load

  • Yang, Xiaoyan;Gong, Jinxin;Xu, Bohan;Zhu, Jichao
    • Computers and Concrete
    • /
    • 제19권6호
    • /
    • pp.725-736
    • /
    • 2017
  • This paper presents the two-, three-, and four-lane transverse reduction factor based on FEA method, probability theory, and the recently actual traffic flow data. A total of 72 composite girder bridges with various spans, number of lanes, loading mode, and bridge type are analyzed with time-varying static load FEA method by ANSYS, and the probability models of vehicle load effects at arbitrary-time point are developed. Based on these probability models, in accordance to the principle of the same exceeding probability, the multi-lane transverse reduction factor of these composite girder bridges and the relationship between the multi-lane transverse reduction factor and the span of bridge are determined. Finally, the multi-lane transverse reduction factor obtained is compared with those from AASHTO LRFD, BS5400, JTG D60 or Eurocode. The results show that the vehicle load effect at arbitrary-time point follows lognormal distribution. The two-, three-, and four-lane transverse reduction factors calculated by using FEA method and probability respectively range between 0.781 and 1.027, 0.616 and 0.795, 0.468 and 0.645. Furthermore, a correlation between the FEA and AASHTO LRFD, BS5400, JTG D60 or Eurocode transverse reduction factors is made for composite girder bridges. For the two-, three-, and four-lane bridge cases, the Eurocode code underestimated the FEA transverse reduction factors by 27%, 25% and 13%, respectively. This underestimation is more pronounced in short-span bridges. The AASHTO LRFD, BS5400 and JTG D60 codes overestimated the FEA transverse reduction factors. The FEA results highlight the importance of considering span length in determining the multi-lane transverse reduction factors when designing two-lane or more composite girder bridges. This paper will assist bridge engineers in quantifying the adjustment factors used in analyzing and designing multi-lane composite girder bridges.

Marginal and internal fit of nano-composite CAD/CAM restorations

  • Park, So-Hyun;Yoo, Yeon-Jee;Shin, Yoo-Jin;Cho, Byeong-Hoon;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • 제41권1호
    • /
    • pp.37-43
    • /
    • 2016
  • Objectives: The purpose of this study was to compare the marginal and internal fit of nano-composite CAD-CAM restorations. Materials and Methods: A full veneer crown and an mesio-occluso-distal (MOD) inlay cavity, which were prepared on extracted human molars, were used as templates of epoxy resin replicas. The prepared teeth were scanned and CAD-CAM restorations were milled using Lava Ultimate (LU) and experimental nano-composite CAD/CAM blocks (EB) under the same milling parameters. To assess the marginal and internal fit, the restorations were cemented to replicas and were embedded in an acrylic mold for sectioning at 0.5 mm intervals. The measured gap data were pooled according to the block types and measuring points for statistical analysis. Results: Both the block type and measuring point significantly affected gap values, and their interaction was significant (p = 0.000). In crowns and inlays made from the two blocks, gap values were significantly larger in the occlusal area than in the axial area, while gap values in the marginal area were smallest (p < 0.001). Among the blocks, the restorations milled from EB had a significantly larger gap at all measuring points than those milled from LU (p = 0.000). Conclusions: The marginal and internal gaps of the two nano-composite CAD/CAM blocks differed according to the measuring points. Among the internal area of the two nano-composite CAD/CAM restorations, occlusal gap data were significantly larger than axial gap data. The EB crowns and inlays had significantly larger gaps than LU restorations.

구치부 수복용 복합레진의 파괴특성에 관한 Acoustic Emission 연구 (ACOUSTIC EMISSION ANALYSIS FOR FRACTURE CHARACTERISTICS OF DENTAL POSTERIOR COMPOSITES)

  • 박진훈;김교한
    • Restorative Dentistry and Endodontics
    • /
    • 제17권1호
    • /
    • pp.153-165
    • /
    • 1992
  • Dental composite resin is a kind of the particle - reinforced composite material, and is widely used in recent dental restoration of anterior and posterior tooth region. The purpose of this study was to investigate the fracture behaviour according to volume fractions and external findings of the filler particles for better interpretation of the fracture characteristics of posterior dental composite resins by analytic method of fracture mechanics. The plane strain fracture toughness($K_{IC}$) and Acoustic Emission were determined with three - point bending test using the single edge notch specimen according to the ASTM - E399, and its analyzed data was compared with filler volume fractions derived from the standard ashing test and scanning electron fractographs of each specimen including the unfilled experimental resin as a control. The results were that the value of fracture toughness of the composite resin material was in the range from 0.85 MPa$\sqrt{m}$ to 1.60 MPa$\sqrt{m}$ and was higher than the value of the unfilled experimental resin, and the fracture behaviours dervied from Acoustic Emission analysis show prominent differences according to the volume fraction and the size of filler particles used in each composite resin. The degree of resistance against crack propagation seems to be increase and the fractographs demonstrate the high degree of surface roughness and irregularity according with the increase of fracture toughness value.

  • PDF

A COMPARATIVE STUDY BETWEEN DEGREE OF CONVERSION AND FLEXURAL STRENGTH OF COMPOSITE RESINS

  • Lee Seong-Hee;Pae Ahran;Kim Sung-Hun
    • 대한치과보철학회지
    • /
    • 제44권3호
    • /
    • pp.333-342
    • /
    • 2006
  • Statement of problem. Although many studies have been carried out to investigate the correlation between the degree of conversion and the flexural strength of composite resins, there is minimal information in the literature attempting to compare degree of conversion, flexural strength and their correlation between restorative composite resins and flowable composite resins. Purpose. The purposes of this study were to measure the degree of conversion and flexural strength of composite resins with different rheological behavior and to correlate the two properties. Materials and methods. Four restorative (Vit-1-escence, Z-250, Tetric ceram, Esthet-X) and four flowable (Aeliteflo, Admiraflow, Permaflo, Revolution) light-curing composite resins were investigated. The degree of conversion(DC) was analyzed with Fourier transfer infra-red spectroscopy(FTIR) spectrum by a potassium bromide(KBr) pellet transmission method. The spectrum of the unpolymerized specimen had been measured before the specimen was irradiated for 60s with a visible light curing unit. The Poiymerized specimen was scanned for its in spectrum. The flexural strength(FS) was measured with 3-point bending test according to ISO 4049 after storage in water at $37^{\circ}C$ for 24 hours. The data were statistically analyzed by an independent sample t-test and one-way ANOVA at the significance level of 0.05. The dependence of flexural strength on the degree of conversion was also analyzed by regression analysis. Results. Mean DC and FS values ranged from 43% to 61% and from 84.7MPa to 156.7MPa respectively. DC values of the flowable composite resins were significantly higher than those of restorative composite resins (P < 0.05). The FS values of restorative composite resins were greater than those of flowable composite resins. No statistically significant correlation was observed between the DC and the FS tested in any of the composites. The dependence of FS on DC in restorative or flowable composite resins was not significant. Conclusion. It can be concluded that radical polymerization of the organic matrix is not a major factor in determining flexural strength of the commercially available composite resins.