• Title/Summary/Keyword: complex vibration test

Search Result 133, Processing Time 0.031 seconds

Reliability of High Temperature and Vibration in Sn3.5Ag and Sn0.7Cu Lead-free Solders (Sn3.5Ag와 Sn0.7Cu 무연솔더에 대한 고온 진동 신뢰성 연구)

  • Ko, Yong-Ho;Kim, Taek-Soo;Lee, Young-Kyu;Yoo, Sehoo;Lee, Chang-Woo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.19 no.3
    • /
    • pp.31-36
    • /
    • 2012
  • In this study, the complex vibration reliability of Sn-3.5Ag and Sn-0.7Cu having a high melting temperature was investigated. For manufacturing of BGA test samples, Sn-3.5Ag and Sn-0.7Cu balls were joined on BGA chips finished by ENIG and the chips were mounted on PCB finished OSP by using reflow process. For measuring of resistance change during complex vibration test, daisy chain was formed in the test board. From the results of resistance change and shear strength change, the reliability of two solder balls was compared and evaluated. During complex vibration for 120 hours, Sn-0.7Cu solder was more stable than Sn-3.5Ag solder in complex vibration test.

Testing for Identification of Dynamic Properties of Viscoelastic Material Subject to Large Static Deformation (정적 대변형을 받고 있는 점탄성 재료의 동적 물성치 규명 시험)

  • 이완술;이호정;조지현;김진성;윤성기;김광준
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.2
    • /
    • pp.132-143
    • /
    • 2003
  • Viscoelastic components for vibration isolation or shock absorption in automobiles, machines and buildings are often subject to a high level of static deformation. From the dynamic design point of view, it is requisite to predict dynamic complex stiffness of viscoelastic components accurately and efficiently. To this end, a systematic procedure for complex modulus measurement of the viscoelastic material under large static deformation is often required in the industrial fields. In this paper, dynamic test conditions and procedures for the viscoelastic material under small oscillatory load superimposed on large static deformation are discussed. Various standard test methods are investigated in order to select an adequate test methodology. The influence of fixed boundary condition in the compression tests upon complex stiffness are investigated and an effective correction technique is proposed. Then the uniaxial tension and compression tests are performed and its results are compared with analysis results from conventional constitutive models.

Analysis of the Friction Induced Instability of Disc Brake using Distributed Parameter Model (분포매개변수를 이용한 디스크 브레이크의 마찰기인 불안정성 해석)

  • 차병규;조용구;오재응
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.601-606
    • /
    • 2004
  • This paper deals with friction-induced vibration of disc brake system under constant friction coefficient. A linear, lumped and distributed parameter model to represent the floating caliper disc brake system is proposed. The complex eigenvalues are used to investigate the dynamic stability and in order to verify simulations which are based on the theoretical model, the experimental modal test and the dynamometer test are performed. The comparison of experimental and theoretical results shows a good agreement and the analysis indicates that mode coupling due to friction force is responsible for disc brake squeal. And squeal type instability is investigated by using the parametric analysis. This indicates parameters which have influence on the propensity of brake squeal. This helped to validate the analysis model and establish confidence in the analysis results. Also they may be useful during system development or diagnostic analysis.

  • PDF

Analysis of the Friction Induced Instability of Disc Brake Using Distributed Parameter Model (분포매개변수를 이용한 디스크 브레이크의 마찰기인 불안정성 해석)

  • 차병규;조용구;홍정혁;이유엽;이정윤;오재응
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.8
    • /
    • pp.702-708
    • /
    • 2004
  • This paper deals with friction-induced vibration of disc brake system under constant friction coefficient. A linear, lumped and distributed parameter model to represent the floating caliper disc brake system is proposed. The complex eigenvalues are used to investigate the dynamic stability and in order to verify simulations which are based on the theoretical model, the experimental modal test and the dynamometer test are performed. The comparison of experimental and theoretical results shows a good agreement and the analysis indicates that mode coupling due to friction force is responsible for disc brake squeal. And squeal type Instability is Investigated by using the parametric analysis. This indicates parameters which have influence on the propensity of brake squeal. This helped to validate the analysis model and establish confidence in the analysis results. Also they may be useful during system development or diagnostic analysis.

Experimental Performance Verification of Energy-Harvesting System Using the Micro-vibration of the Spaceborne Cryocooler (우주용 냉각기의 미소진동을 이용한 에너지 수확 시스템의 실험적 성능검증)

  • Jung, Hyunmo;Kwon, Seongcheol;Oh, Hyunung
    • Journal of Aerospace System Engineering
    • /
    • v.10 no.3
    • /
    • pp.15-22
    • /
    • 2016
  • The on-board appendages of satellites with mechanical moving parts such as the fly-wheel, the control-moment gyro, the cryocooler, and the gimbal-type directional antenna can generate an undesirable micro-vibration disturbance, which is one of the main causes of the image-quality degradation that affects high-resolution observation satellites. Consequently, the isolation of the micro-vibration issue has always been considered as salient, and the micro-vibration is therefore the focus of this study wherein a complex system that can provide the dual functions of a guaranteed vibration-isolation performance and electrical energy harvesting is proposed. The vibration-isolation and energy-harvesting performances of the complex system are predicted through a numerical analysis based on the characteristics that are obtained from component-level tests. In addition, the effectiveness of the complex system that is proposed in this study is verified through an assembly-level functional-performance test.

A Study on an Optimal Design & Manufacture of Vibration Test Fixture(l) (진동시험 치구의 최적설계 및 제작에 관한 연구(I))

  • Kim, Do-Young;Nam, Gung-Suk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.6 no.3
    • /
    • pp.46-59
    • /
    • 1989
  • The purpose of test fixture is to mechanically couple energy from a shaker into a test specimen. And then it is necessary to design a fixture of shich the fundamental natural frequency is over than one half times as high as the highest frequency of interest. But the dynamic behavior of vibration test fixture is usually different from, often far different from, what has been calculated. In this paper, the optimal dimensionless frequency parameter, ${lambda}$'s, are calculated from the test results of a various and complex shaped fixtures.

  • PDF

The Grid Strap Vibration Characteristics of the 5×5 Nuclear Fuel Mock-up (5×5 핵연료 모의 집합체의 지지격자 스트랩 진동특성)

  • Kim, Kyoung-Hong;Park, Nam-Gyu;Kim, Kyoung-Ju;Suh, Jung-Min
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.7
    • /
    • pp.619-625
    • /
    • 2012
  • Since the fuel is always exposed to turbulent flow, the grid strap shows flow induced vibration characteristics that impact on the nuclear fuel soundness. The dynamic behavior of grids in nuclear fuels is quite complex, since two pairs of spring and dimple support are contacted with rods by friction in the limited space. This paper focuses on investigation of the grid strap(test fuel strap, TFS) vibration in one cell. TFS consists of a single spring and double dimples. To identify the grid strap vibration, modal analysis of the strap is performed using finite element method(FEM). Modal testing on a $5{\times}5$ grid structure without rods is performed. The modal testing results are compared to analytic results. In addition, random test considering rod effect is performed about a $5{\times}5$ grid with rods under real contact condition in the air. Finally, the strap vibration of a $5{\times}5$ fuel bundle in investigation of flow induced vibration(INFINIT) facility is measured in real fluid velocity condition without heating. It is shown that modal frequencies from the test are almost equal to those peak frequencies in the INFINIT test.

An Experimental Study on the Establishment of Indoor Noise Criteria - Focused on Korean Complex Building- (실내 소음기준 설정에 관한 실험적 연구 -동일 건물내 사업장을 중심으로-)

  • Lee, Tai-Gang;Kook, Chan;Jang, Gil-Soo;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.9-12
    • /
    • 2008
  • There are many place of business in complex building, and recently claims of noise have increased in those buildings. It is most desirable reducing the noise problems to establish the noise criteria considering the noise source and the receiving place of business, which are derived from the dose-response of noise and results of the actual condition. The degree of response to the transmission noise could be changed with background noise level in the receiving stores. In this research, the subjective evaluation for three different background level in receiving place of business or rooms were investigated from subjective tests. The eight business sound source including aerobic music were used for the test.

  • PDF

A Performance Analysis and Experiment of Viscous Torsional Vibration Damper for High Speed Engine Shaft System (고속엔진축계용 점성 비틀림진동감쇠기의 성능해석 및 실험)

  • Yang, B.S.;Jeong, T.Y.;Kim, K.D.;Kim, D.J.
    • Journal of Power System Engineering
    • /
    • v.1 no.1
    • /
    • pp.98-105
    • /
    • 1997
  • In general, crankshafts which are used in internal combustion reciprocating engines are subjects to high torsional vibration. Therefore, a damper is often used to minimize the torsional vibration in reciprocating engines. In this paper, in order to investigate damping performance of viscous damper, the real effective viscosity and complex damping coefficient of silicone oil, and the effective inertia moment of inertia ring are calculated considering the relative motion between damper casing and inertia ring. Based on these results multi-cylinder shaft is modeled into equivalent 2-degree of freedom system and optimum condition is estimated by calculating the amplification factor of viscous damper. Also the test damper was manufactured according to the result of theoretical investigation, the performance and durability was ascertained through experimental examination.

  • PDF

A Development of a Variable Dynamic Force Type Exciter for Modal Test of a Large Structure (대형구조물 동특성 실험을 위한 가변 동하중 가진 시스템 개발)

  • Son, S.W.;Lee, H.G.;Choi, C.H.;Kang, D.E.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.826-831
    • /
    • 2002
  • In order to investigate the dynamic characteristics of real structure, many dynamic engineer had been interested in modal test however it is not easy to perform dynamic test of large structure because of many difficulties such as unsatisfied excitation force in global mode frequency range, measurement of dynamic force and so on. Therefore. new type vibration exciter with variable stiffness support system and dynamic force was developed to provide a improved experimental environment for a large and complex structure. The developed exciter improved from two viewpoint, dynamic performance and utility convenience. its characteristics was shown in this paper.

  • PDF