• Title/Summary/Keyword: complex signals

Search Result 570, Processing Time 0.028 seconds

A phase synthesis time reversal impact imaging method for on-line composite structure monitoring

  • Qiu, Lei;Yuan, Shenfang
    • Smart Structures and Systems
    • /
    • v.8 no.3
    • /
    • pp.303-320
    • /
    • 2011
  • Comparing to active damage monitoring, impact localization on composite by using time reversal focusing method has several difficulties. First, the transfer function of the actuator-sensor path is difficult to be obtained because of the limitation that no impact experiment is permitted to perform on the real structure and the difficulty to model it because the performance of real aircraft composite is much more complicated comparing to metal structure. Second, the position of impact is unknown and can not be controlled as the excitation signal used in the active monitoring. This makes it not applicable to compare the difference between the excitation and the focused signal. Another difficulty is that impact signal is frequency broadband, giving rise to the difficulty to process virtual synthesis because of the highly dispersion nature of frequency broadband Lamb wave in plate-like structure. Aiming at developing a practical method for on-line localization of impact on aircraft composite structure which can take advantage of time reversal focusing and does not rely on the transfer function, a PZT sensor array based phase synthesis time reversal impact imaging method is proposed. The complex Shannon wavelet transform is presented to extract the frequency narrow-band signals from the impact responded signals of PZT sensors. A phase synthesis process of the frequency narrow-band signals is implemented to search the time reversal focusing position on the structure which represents the impact position. Evaluation experiments on a carbon fiber composite structure show that the proposed method realizes the impact imaging and localization with an error less than 1.5 cm. Discussion of the influence of velocity errors and measurement noise is also given in detail.

Design of a Frequency Offset Corrector and Analysis of Noises due to Quantization Angle in OFDM LAN Systems (OFDM 시스템에서 주파수편차 교정기의 설계와 각도 양자화에 의한 잡음의 분석)

  • 황진권
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.7A
    • /
    • pp.794-806
    • /
    • 2004
  • This paper deals with correction of frequency offset and analysis of quantization angle noise in the IEEE 802.1la OFDM system. The rotation phase per symbol due to the carrier frequency offset is estimated from auto-correlation of the short Preambles, which are over-sampled for the reduction of noise in OFDM signals. The pilot signals are introduced to estimate the rotation phase per OFDM symbol due to estimation error of the carrier frequency offset and the sampling frequency onset. During the estimation and correction of the frequency onsets, a CORDIC processor and a look-up table are used for the conversion between a rotation phase and its complex number. Being calculated by a limited number of bits in the CORDIC processor and the look-up table, the rotation phase and its complex number have quantization angle errors. The quantization errors are analyzed as SNR (signal to noise ratio) due to the quantization bit numbers. The minimum bit number is suggested to meet the specification of IEEE 802.1la properly. Finally, the quantization errors are evaluated through simulations on number of quantization bits and SNR of received signals.

Research on Digital Complex-Correlator of Synthetic Aperture Radiometer: theory and simulation result

  • Jingye, Yan;Ji, Wu;Yunhua, Zhang;Jiang, Changhong;Tao, Wang;Jianhua, Ren;Jingshan, Jiang
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.587-592
    • /
    • 2002
  • A new digital correlator fur an airborne synthetic aperture radiometer was designed in order to replace the conventional analog correlator unit which will become very complicated while the number of channels is increasing. The digital correlator uses digital IQ demodulator instead of the intermediate frequency (IF) phase shifter to make the correlation processing performed digitally at base band instead of analogly at IF. This technique has been applied to the digital receiver in softradio. The down-converted IF signals from each pair of receiver channels become low rate base-band digital signals after under-sampled, Digitally Down-Converted (DDC), decimated and filtered by FIR filters. The digital signals are further processed by two digital multipliers (complex correlation), the products are integrated by the integrators and finally the outputs from the integrators compose of the real part and the imaginary part of a sample of the visibility function. This design is tested by comparing the results from digital correlators and that from analog correlators. They are agreed with each other very well. Due to the fact that the digital correlators are realized with the help of Analog-Digital Converter (ADC) chips and the FPGA technology, the realized volume, mass, power consumption and complexity turned out to be greatly reduced compared with that of the analog correlators. Simulations show that the resolution of ADC has an influence on the synthesized antenna patterns, but this can be neglected if more than 2bit is used.

  • PDF

A Combined QRS-complex and P-wave Detection in ECG Signal for Ubiquitous Healthcare System

  • Bhardwaj, Sachin;Lee, Dae-Seok;Chung, Wan-Young
    • Journal of information and communication convergence engineering
    • /
    • v.5 no.2
    • /
    • pp.98-103
    • /
    • 2007
  • Long term Electrocardiogram (ECG) [1] analysis plays a key role in heart disease analysis. A combined detection of QRS-complex and P-wave in ECG signal for ubiquitous healthcare system was designed and implemented which can be used as an advanced warning device. The ECG features are used to detect life-threating arrhythmias, with an emphasis on the software for analyzing QRS complex and P-wave in wireless ECG signals at server after receiving data from base station. Based on abnormal ECG activity, the server will transfer alarm conditions to a doctor's Personal Digital Assistant (PDA). Doctor can diagnose the patients who have survived from cardiac arrhythmia diseases.

Enhanced least square complex frequency method for operational modal analysis of noisy data

  • Akrami, V.;Zamani, S. Majid
    • Earthquakes and Structures
    • /
    • v.15 no.3
    • /
    • pp.263-273
    • /
    • 2018
  • Operational modal analysis is being widely used in aerospace, mechanical and civil engineering. Common research fields include optimal design and rehabilitation under dynamic loads, structural health monitoring, modification and control of dynamic response and analytical model updating. In many practical cases, influence of noise contamination in the recorded data makes it difficult to identify the modal parameters accurately. In this paper, an improved frequency domain method called Enhanced Least Square Complex Frequency (eLSCF) is developed to extract modal parameters from noisy recorded data. The proposed method makes the use of pre-defined approximate mode shape vectors to refine the cross-power spectral density matrix and extract fundamental frequency for the mode of interest. The efficiency of the proposed method is illustrated using an example five story shear frame loaded by random excitation and different noise signals.

Separation of Seismic Signals using a Polarization Filter based on the Complex Trace Analysis Method (복소트레이스 분극필터를 이용한 다성분 탄성파자료 신호분리)

  • Kim, Ki-Young;Lee, So-Young
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.233-236
    • /
    • 2005
  • Polarization filtering based on the multicomponent complex trace analysis method is performed to reject Rayleigh waves and to enhance S waves. To test the polarization filter, synthetic seismic data were constructed for a simple two-layer model based on the finite difference method. Rayleigh waves with elliptic motion are eliminated effectively and P and S waves with linear motions are well separated each other.

  • PDF

Performance Analysis of Co-Existence of DS-CDMA and TDMA System by Using Complex Multirate Filter Bank in Land Mobile Channel (육상 이동통신 채널에서 복소 다중비율 필터뱅크를 채용한 DS-CDMA/TDMA 공존 시스템의 성능 분석)

  • 우병훈;강희조
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.1
    • /
    • pp.1-7
    • /
    • 2000
  • In this paper, we proposed a complex multirate filter bank(CMRFB) based adaptive notch filtering technique to solve the co-existence narrowband interference problem of DS-CDMA and TDMA systems. We have discussed error performance of co-existence of DS-CDMA and TDMA system by using complex multirate filter bank in land mobile channel and computer simulation results show that the proposed scheme can eliminate the narrowband interference(TDMA signals) effectively.

  • PDF

Separation of Seismic Signals using a Polarization Filter based on the Complex Trace Analysis Method (복소트레이스 분극필터를 이용한 다성분 탄성파자료 신호분리)

  • Kim, Ki-Young;Lee, So-Young
    • Journal of the Korean Geophysical Society
    • /
    • v.8 no.1
    • /
    • pp.35-38
    • /
    • 2005
  • Polarization filtering based on the multicomponent complex trace analysis method is performed to reject Rayleigh waves and to enhance S waves. To test the polarization filter, synthetic seismic data were constructed for a simple two-layer model based on the finite difference method. Rayleigh waves with elliptic motion are eliminated effectively and P and S waves with linear motions are well separated each other.

  • PDF

Complex Bandpass Sampling for SDR front-end (SDR front-end를 위한 Complex Bandpass Sampling)

  • Wang, Hong-Mei;Kim, Jae-Hyung;Kim, Hyung-Jung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.8
    • /
    • pp.1805-1812
    • /
    • 2011
  • Bandpass sampling technique has an advantage that it uses lower sampling frequency than Nyquist criterion. But special care is required in choosing sampling frequency to avoid self-image overlapping in the first Nyquist region. Recently, the second-order BPS techniques which can suppress possible self-image by using an additional ADC and by employing digital signal processing have been proposed. This paper addresses a complex BPS based SDR front-end. Unlike general second-order BPS, it needs simple FIR filter to compensate delay in the second ADC. We show a method to find proper sampling frequencies to down convert RF signals selected by tunable RF filter operating in arbitrary frequency range.

Nonlinear response of complex fluids under LAOS(large amplitude oscillatory shear) flow

  • Ahn, Kyung-Hyun;Kyu Hyun;Nam, Jung-Gun;Manfred Wilhelm;Lee, Seung-Jong
    • Korea-Australia Rheology Journal
    • /
    • v.15 no.2
    • /
    • pp.97-105
    • /
    • 2003
  • In the previous paper (Hyun et al.,2002), we have investigated the shape of storage modulus (G') and loss modulus (G") of complex fluids under large amplitude oscillatory shear (LAOS) flow. As the strain amplitude increases, owever, the stress curve becomes distorted and some important information may be smothered during data processing. Thus we need to investigate the stress data more precisely and systematically. In this work, we have obtained the stress data using high performance ADC (analog digital converting) card, and investigated the nonlinear response of complex fluids, 4wt% xanthan gum (XG), 2 wt% PVA/ 1 wt% Borax, and 1 wt% hyaluronic acid (HA) solutions, using Fourier transformation (FT) rheology. Comparing the strain signals in time domain with FT parameters in frequency domain, we could illustrate the sensitivity and importance of FT rheology. Diverse and unique stress patterns were observed depending on the material system as well as flow environment. It was found that they are not the outcome of experimental deficiency like wall slip but characteristics of the material system. When nonlinear response of complex fluids is analyzed, the intensity and phase angle of higher harmonic contributions should be considered together, and the shape of the stress signal was found to be strongly dependent upon phase angle.ngle.