• Title/Summary/Keyword: compensator.

검색결과 1,349건 처리시간 0.027초

Phase Offset Correction using Early-Late Phase Compensation in Direct Conversion Receiver (직접 변환 수신기에서 Early-Late 위상 보상기를 사용한 위상 오차 보정)

  • Kim Young-Wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • 제9권3호
    • /
    • pp.638-646
    • /
    • 2005
  • In recent wireless communications, direct conversion transceiver or If sampling SDR-based receivers have being designed as an alternative to conventional transceiver topologies. In direct conversion receiver a.chitectu.e, the 1.equency/phase offset between the RF input signal and the local oscillator signal is a major impairment factor even though the conventional AFC/APC compensates the service deterioration due to the offset. To rover the limited tracking range of the conventional method and effectively aid compensation scheme in terms of I/Q channel imbalances, the frequency/phase offset compensation in RF-front end signal stage is proposed in this paper. In RF-front end, the varying phase offset besides the fixed large frequency/phase offset are corrected by using early-late phase compensator. A more simple frequency and phase tacking function in digital signal processing stage of direct conversion receiver is effectively available by an ingenious frequency/phase offset tracking method in RF front-end stage.

Analysis of Control Algorithm for Instantaneous Voltage Sag Corrector (순시적인 전압 sag 보상기에 대한 제어 알고리즘의 해석)

  • 이상훈;김재식;최재호
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • 제6권2호
    • /
    • pp.173-179
    • /
    • 2001
  • This paper represents the control algorithm of the instantaneous voltage sag corrector for the power quality enhancement in distribution line. Especially, a novel detection technique of the symmetrical components is proposed for the analysis of the three-phase unbalanced and asymmetrical problems caused by the single line ground fault which is he most frequent event. This proposed method is based on the simple calculation and the control references of the symmetrical components for voltage compensation can be described as dc value without any other phase detection procedure. And also, for the generation of the reference voltages, the UF and MF defined by IEC is considered. Using this proposed control algorithm, the compensator has the fast dynamic characteristics and the THD of the compensated voltage waveform is very low. Finally, the validity of the proposed algorithm is proved by the PSCAD/EMTDC simulation and experimental results.

  • PDF

Liquid Level System Realizing Van de Vusse Reactor Dynamics and its Control Experiments (Van de Vusse 반응기 동특성을 구현하는 액위시스템 및 제어 실험)

  • Lee, Jietae
    • Korean Chemical Engineering Research
    • /
    • 제58권2호
    • /
    • pp.184-189
    • /
    • 2020
  • Van de Vusse reactors show the maximum points in input-output steady state maps and dramatic changes in their dynamic characteristics around those maximum points. According to their operating regions, there appear sign changes in steady state gains and nonlinear characteristics such as non-minimum phase dynamics which cause difficulties in applying controllers. Many nonlinear controllers that are available and newly designed are applied to these Van de Vusse reactor processes and their performances are tested. Reactor examples with real reactions have been reported. However, due to difficulties in constructing and operating chemical reactor systems, they are not adequate to be used for real applications of control experiments and hence most of results are based on simulations studies. Here, we propose a liquid level system that realizes most of the steady state and dynamic characteristics of Van de Vusse reactor, and two nonlinear control methods that can be used as base methods to compare nonlinear controllers newly designed. Liquid level experimental system and two nonlinear control methods are very simple and can be used to test performances of nonlinear controllers in practice.

Variable Passive Compliance Device for Robotic Assembly (조립 로봇용 가변 수동 강성 장치의 설계)

  • Kim, Hwi Su;Park, Dong Il;Park, Chan Hun;Kim, Byung In;Do, Hyun Min;Choi, Tae Yong;Kim, Doo Hyung;Kyung, Jin Ho
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • 제25권6호
    • /
    • pp.517-521
    • /
    • 2016
  • General industrial robots are difficult to use for precision assembly because they are operated based on position control. Their position accuracy is also usually higher than the assembly clearance (several tens of ${\mu}m$). In previous researches, force control was suggested as a robotic assembly solution. However, this method is difficult to apply in reality because of speed and cost problems. The RCC provides high speed, but applications are limited because the compliance is fixed, and it cannot detect an assembly condition during a task. A variable passive compliance device (VPCD) was developed herein. The VPCD can detect the assembly condition during tasks. This device can provide proper compliance for successful assembly tasks. The pneumatic system and the Stewart platform with an LVDT sensor were applied for measuring the displacement and variable compliance, respectively. The concept design and analysis were conducted to prove the effectiveness of the developed VPCD.

DC Motor Drive System Using Model Based Cotroller Design of LabVIEW and Compact RIO (LabVIEW의 모델기반 제어기 설계와 Compact RIO를 이용한 직류전동기 구동 시스템)

  • Ji, Jun-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제9권2호
    • /
    • pp.352-359
    • /
    • 2008
  • This paper presents a controller implementation using model based controller design programs-System Identification Toolkit, Control Design Toolkit, Simulation module. This method is easier and simpler than conventional controller design method. To implement speed control system of DC motor, a CompactRIO, Real-Time(RT) cntroller provided by NI(National Instruments), is used as hardware equipment. Firstly transfer function of DC motor drive system, which was a control target plant, can be acquired through System Identification Toolkit by using test input signal applied to motor and output signal from motor. And designing of pole-zero compensator satisfying desired control response performance through Control Design Toolkit, designed speed control response can be tested through Simulation Module. Finally LabVIEW program is converted to real-time program and downloaded to CompactRIO real-time controller Through experimental results to real DC motor drive system, designed speed control response is compared to simulation results.

Voltage Control of Power System Connected to a Wind Farm by Using STATCOM and Reactive Power Compensators (STATCOM과 조상설비를 이용한 풍력단지가 연계된 전력계통의 전압제어)

  • Seo, Gyu-Seok;Park, Ji-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제16권4호
    • /
    • pp.2737-2743
    • /
    • 2015
  • The wind power plant must be able to produce reactive power at the POI bus of a wind farm connected to power system to keep or control the voltage of POI bus. But, the reactive power capability of wind turbines may not be sufficient to control the voltage of POI bus due to the reactive power losses in connection lines between wind farm and POI bus. The solution of this problem is to install an external STATCOM. The proposed cooperative control method of STATCOM and conventional reactive power compensators such as Switched-shunt and tap changing transformer can control the voltage of POI bus more efficiently. The simulation results are shown that the voltage drop of POI Bus of Test System with the arbitrary load change rate to initial loads is improved more than 60% and the voltage of load bus is maintained more than 95% of rated voltage.

Androgen in the Uterus: A Compensator of Estrogen and Progesterone

  • Cheon, Yong-Pil;Lee, Dong-Mok;Chun, Tea-Hoon;Lee, Ki-Ho;Choi, In-Ho
    • Development and Reproduction
    • /
    • 제13권3호
    • /
    • pp.133-143
    • /
    • 2009
  • Pivotal roles of steroid hormones in uterine endometrial function are well established from the mouse models carrying the null mutation of their receptors. Literally androgen belongs to male but interestingly it also detected in female. The fluctuations of androgen levels are observed during reproductive cycle and pregnancy, and the functional androgen receptor is expressed in reproductive organs including uterus. Using high throughput methodology, the downstream genes of androgen have been isolated and revealed correlations between other steroid hormones. In androgen-deficient mice, uterine responses to exogenous gonadotropins are impaired and the number of pups per litter is reduced dramatically. As expected androgen has important role in decidual differentiation through AR. It regulates specific gene network during those cellular responses. Recently we examined the effects of steroid hormonal complex containing high level of androgen. Interestingly, on the contrary to the androgen-alone administration, the hormonal complex did not disturb the decidual reaction and the pubs did not show any morphological abnormality. It is suspected that the complexity of communication between other steroid hormone and their receptors are the reasons. In summary, androgen exists in female blood and it suggests the importance of androgen in female reproduction. However, the complex interactions with other hormones are not fully understood compared with estrogen and progesterone. The further studies to evaluate the possible role of androgen are needed and important to provide the in vivo rational for the prevention of associated pregnancy complications and help human's health.

  • PDF

The Body-Coupling Compensation in the 2-Gimbaled Seeker for the Homing Guidance of Bank-to-Turn Missile (Bank-to-Turn 유도탄의 호밍유도를 위한 2축 김발형 탐색기 동체운동 상관 보상)

  • Jeong, Sang-Keun;Kim, Eul-Gon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • 제30권6호
    • /
    • pp.101-106
    • /
    • 2002
  • In a bank-to-turn(BTT) missile, if a 2-gimbaled seeker was stabilized using a 2-axis rate gyro mounted along its primary axis, the change of line of sight(LOS) measured by the seeker would be induced by rolling effects due to bank-to-turn(BTT) steering as well as an actual change. It is observed that the body-coupled effects in a homing loop of BTT missile are mainly concerned with the spurious target maneuver and the coupling due to the rate gyro misalignments. In this paper, we formulate a simple linear BTT homing loop model with seeker model including each body-coupling. With the model, we analyze the effects of the couplings on the homing loop stability, and propose a direct linear compensator for the coupling to recover the stability.

The Development of Battery Energy Storage System (전지를 이용한 에너지저장시스템 개발)

  • Ko, Yo;Eom, Young-Chang;Kim, Yun-Ho
    • Journal of Energy Engineering
    • /
    • 제2권1호
    • /
    • pp.104-113
    • /
    • 1993
  • Due to steady increase of electric power demand and decrease of load factor, the economic and reasonable operation of electric power system is necessary. Because of this reason, dispersed battery energy storage system(BESS) with fast response is receiving attractive attention. With these considerations, 20 kVA BESS is designed and tested to investigate the possibility of BESS application to power system. This paper describes the design specifications of simulator and test results. BESS is composed of batteries, conversion equipments, interconnecting equipments to power system, and control parts of the system. The inverter of BESS can carry out two functions as charger and discharger. Also, it can operate as a VAR compensator by four quadrant operation. Since this system is designed as a simulator of MW system, the conceptual design of MW system is possible by using the test result of test system The study of BESS is preliminary stage for the future MW class BESS.

  • PDF

Experimental and numerical study on coupled motion responses of a floating crane vessel and a lifted subsea manifold in deep water

  • Nam, B.W.;Kim, N.W.;Hong, S.Y.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제9권5호
    • /
    • pp.552-567
    • /
    • 2017
  • The floating crane vessel in waves gives rise to the motion of the lifted object which is connected to the hoisting wire. The dynamic tension induced by the lifted object also affects the motion responses of the floating crane vessel in return. In this study, coupled motion responses of a floating crane vessel and a lifted subsea manifold during deep-water installation operations were investigated by both experiments and numerical calculations. A series of model tests for the deep-water lifting operation were performed at Ocean Engineering Basin of KRISO. For the model test, the vessel with a crane control system and a typical subsea manifold were examined. To validate the experimental results, a frequency-domain motion analysis method is applied. The coupled motion equations of the crane vessel and the lifted object are solved in the frequency domain with an additional linear stiffness matrix due to the hoisting wire. The hydrodynamic coefficients of the lifted object, which is a significant factor to affect the coupled dynamics, are estimated based on the perforation value of the structure and the CFD results. The discussions were made on three main points. First, the motion characteristics of the lifted object as well as the crane vessel were studied by comparing the calculation results. Second, the dynamic tension of the hoisting wire were evaluated under the various wave conditions. Final discussion was made on the effect of passive heave compensator on the motion and tension responses.