• Title/Summary/Keyword: compare

Search Result 30,684, Processing Time 0.063 seconds

Study on the Evaluation of Renal Function According to Set a Partial Region of Interest in 99mTc-DMSA scan of the Pediatric Patient with a Duplicated Ureter (중복요관을 가진 소아환자의 99mTc-DMSA 검사에서 부분적 관심영역 설정에 따른 신기능 평가에 관한 연구)

  • Nam-Koong, Hyuk;Oh, Shin Hyun;Kim, Jung Yul;Choi, Yoon Jung;Kim, Jae Sam;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.43-47
    • /
    • 2013
  • Purpose: A duplicated ureter is congenital renal malformations with ureter in two. Patients with duplicated ureter are in force to $^{99m}Tc-DMSA$ scan at surgery before and after. In existing examination, at produce result after $^{99m}Tc-DMSA$ scan, didn't compare to upper pole and lower pole with malformed kidney and compared to only relative uptake ratio. Therefore, this study will examine about utility of set a partial region of interest and to functional recovery of renal cell through change of upper pole uptake ratio of malformed kidney by setting each partial region of interest in upper pole and lower pole of malformed kidney in $^{99m}Tc-DMSA$ examination in surgery before and after. Materials and Methods: Pediatric patients with malformed kidney of incomplete duplicated ureter, 15 patients were enrolled in this study. Scanning were scan 3 to 4 hours after injection of $^{99m}Tc-DMSA$ 1.5 ~ 1.9 MBq/kg. Region of interest were each set in normal kidney, upper pole and lower pole with malformed kidney. Region of interest were set with same condition and method to images of surgery before and after that radio technologist 1 person, resident of nuclear medicine 1 person and doctor of urology together. Therefore, this study were compared to uptake ratio (A: B: C) that normal kidney (A), lower pole of malformed kidney (B) and upper pole of malformed kidney (C) about uptake ratio changes of malformed kidney in follow-up examination of surgery before and after. Results: When compared to 15 patients, uptake ratios were increased 7 persons and decreased 8 persons. Among increased 7 persons, it were periods of follow-up examination that 2 persons were 14 months, 4 persons were 12 months and 1 person was 8 months after surgery. Among decreased 8 persons, it were periods of follow-up examination that 4 persons were 12 months 3 persons were 6 months and 1 persons were 4 months after surgery. Conclusion: Existing study could not see the exact uptake ratio changes of malformed kidney because using only the overall Left-Right kidney uptake ratios. But a setting partial region of interest was able to see exactly what changes in the uptake of each upper pole and lower pole of malformed kidney. Because recovery of renal parenchymal cells is difficult in an evaluation of short period of time, follow-up examination should be made in long period of time. How to set up partial region of interest be thought that it would be useful.

  • PDF

Clinical Efficacy of Clomiphene Citrate and Letrozole Combined with Gonadotropins for Superovulation in Patients with Clomiphene-Induced Thin Endometrium (클로미펜에 얇은 자궁내막을 보이는 환자에서 성선자극호르몬 병합 과배란유도시 클로미펜과 레트로졸의 임상적 효용성)

  • Lee, Eun-Joo;Park, Hyun-Jong;Yang, Hyo-In;Lee, Kyung-Eun;Seo, Seok-Kyo;Kim, Hye-Yeon;Cho, Si-Hyun;Choi, Young-Sik;Lee, Byung-Seok;Park, Ki-Hyun;Cho, Dong-Jae
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.36 no.2
    • /
    • pp.111-119
    • /
    • 2009
  • Objective: The aim of this study was to compare the clinical efficacy of clomiphene citrate (CC) and letrozole combined with gonadotropins for controlled ovarian stimulation (COS) in patients with CC-induced thin endometrium Methods: Fifty-one intrauterine insemination cycles performed in patients who previously had a thin endometrium (<8 mm) to ovulation induction using CC were included in this study. A CC 100 mg/day (CC+gonadotropin group, n=26) or letrozole 2.5 or 5 mg/day (letrozole+gonadotropin group, n=25) was administered on day 3~7 of the menstrual cycle, combined with gonadotropins at dose 75~150 IU every other day starting on day 5~7. We compared total dose of gonadotropin used, endometrial thickness, endometrial pattern, number of follicles ${\geq}14\;mm$ on hCG day, pregnancy rate and multiple pregnancy rate between the two groups, which were statistically analyzed using Mann-Whitney U test or Fisher's exact test, where appropriate. Results: There were no significant differences in clinical characteristics such as age, duration of infertility, number of previous IUI cycles, basal serum hormone levels and cause of infertility between the two groups. In both groups, the endometrium was significantly thicker than that of previous ovulation induction cycles using CC. No significant differences were found in the total dose of gonadotropin used, day of hCG administration, the rate of triple endometrium and pregnancy rate. The number of follicles ${\geq}14\;mm$ was significantly lower ($3.7{\pm}1.7$ vs. $2.8{\pm}1.7$, p=0.03) and the endometrium on hCG day was significantly thicker ($7.7{\pm}1.5$ vs. $9.1{\pm}1.7$, p=0.001) in letrozole+gonadotropin group compared to CC+gonadotropin group. Conclusion: The clomiphene citrate and letrozole combined with gonadotropins appear to avoid the undesirable effects on the endometrium frequently seen with CC for ovulation induction. However, in terms of adequate endometrial development or optimal follicular growth, letrozole may be more beneficial than CC for gonadotropin-combined COS in patients with CC-induced thin endometrium. Further prospective randomized controlled studies in a larger scale will be necessary to confirm our findings.

Measurement of the Grafts for the Anterior Cruciate Ligament Reconstruction with Tension Load Technique and Achilles Tendon Autograft using Postoperative Magnetic Resonance Imaging (자가 아킬레스 건과 장력 부하 기법을 이용한 전방십자인대 재건술 후 자기 공명 영상을 이용한 이식건의 평가)

  • Seo, Jai-Gon;Moon, Young-Wan;Yoo, Jae-Chul;Chang, Moon-Jong;Kim, Seung-Yeon;Kim, Mu-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.191-197
    • /
    • 2008
  • Purpose: To evaluate the postoperative magnetic resonance image (MRI) findings of anterior cruciate ligament (ACL) reconstructed with a tension load technique using auto-Achilles tendon, and to compare the results with knees with a native ACL. Materials and Methods: We evaluated 21 postoperative MRI scan of 21 patients (group A) who had undergone ACL reconstruction between January 1995 and November 1996. The control group (group B) consisted of 50 patients whose meniscus tear had been operated by arthroscopy and whose ACL was intact. We measured the orientation of the graft in the sagittal and coronal planes and compared it with that of the native ACL. Results: The mean sagittal angle of the ACL angle in group A ($55.7{\pm}5.6^{\circ}$, range $47.2{\sim}68.8^{\circ}$) was statistically lesser than group B ($58.7{\pm}3.8^{\circ}$, range $50.4{\sim}67.5^{\circ}$) (p=0.036). But there was no statistically significant difference between the two groups with regard to the mean ACL-Blumensaat line angle (group A: $8.1^{\circ}{\pm}4.9^{\circ}$, range $1.7^{\circ}{\sim}22.0^{\circ}$, group B: $8.6^{\circ}{\pm}3.6^{\circ}$, range $2.6^{\circ}-18.1^{\circ}$) and the mean coronal angle of the ACL (group A: $64.9^{\circ}{\pm}9.1^{\circ}$, range $46.9^{\circ}{\sim}76.4^{\circ}$, group B: $65.9^{\circ}{\pm}4.4^{\circ}$, range $57.7^{\circ}{\sim}75.2^{\circ}$)(p=0.88, p= 0.62). In the sagittal plane, the mean center of tibial insertion of the ACL graft in group A ($31.9{\pm}7.1%$, range 22.4-47.9%) was positioned more anteriorly than group B ($37.0{\pm}4.9%$, range $18.5{\sim}44.7%$)(p=0.005). But in the coronal plane, there was no statistically significant difference between the two groups(group A: $46.3{\pm}2.8%$, range $42.1{\sim}52.5%$, group B: $45.7{\pm}2.8%$, range $41.0{\sim}49.1%$)(p=0.392). Conclusion: We performed an ACL reconstruction with the tension load technique using auto-Achilles tendon and we found that the graft orientation in MRI was as good as that of the native ACL.

  • PDF

Studies on the Effect of Feeding Pelleted Diets on Energy Metabolism and Nitrogen Retention in Growing Chickens (Pellet사료(飼料)의 급여(給與)가 병아리의 대사(代謝)에너지와 질소축적(窒素蓄積)에 미치는 영향(影響))

  • Park, Chang Sik;Kwon, Soon Ki;Min, Tae Hyuk
    • Korean Journal of Agricultural Science
    • /
    • v.10 no.2
    • /
    • pp.206-211
    • /
    • 1983
  • This study was carried out to compare the feed utilization between pelleted and all-mash diet of similar composition by growing chickens. Day-old broilers (Hubbard) and egg-type chickens(Hy-line) of commercial strain were employed in this experiment. The results obtained were summarized as follows. 1. The chickens fed pelleted diets were heavier than those of birds fed all-mash diets. The Hubbard broilers and Hy-line chickens fed pelleted diets weighed 2,702g and 812g respectively, at 9 weeks of age. In comparison, the Hubbard broilers and Hy-line chickens fed all-mash diets weighed 2,571g and 777g respectively, at 9 weeks of age. 2. The pellet-fed chickens consumed more feeds than birds fed all-mash diets in both types of strain. Feed efficiencies (gain/feed) of Hubbard and Hy-line chickens were 0.38 and 0.26 in pellet feeding groups, and 0.36 and 0.25 in all-mash feeding groups, respectively. The Hy-line chickens fed pelleted diets drank more water than birds fed all-mash diets. 3. Pellet feeding groups produced more dry matter excreta as compared with all-mash feeding groups, reflecting the pattern of feed consumption by these chickens. Nitrogen retention ratio of the Hubbard and Hy-line chickens were 57-67% and 65-73%, respectively. Chickens fed pelleted diets showed 1-4% higher nitrogen retention than chickens fed all-mash diets. 4. The ME/GE ratio of the Hubbard and the Hy-line at 8 weeks of age were 73.4-74.3% and 82.8-83.8%, respectively. Pellet feeding groups showed 1% higher ME/GE ratio than all-mash feeding groups. 5. The dietary productive energy calculated from respiratory quotient was $94.1-102.6kca/kg^{\frac{3}{4}}$ BW/day in pellet feeding groups. The ratios of PE/GE were 41.3-48.9% in pellet feeding groups and 39.0-45.8% in all-mash feeding groups. 6. It appears that pelleting the all-mash diet increases feed consumption and body weight gain of growing chickens. Feed efficiency and energy utilization were also improved by pelleting process. More research work should be done to establish the relationship clearly between feed pelleting and heat increments.

  • PDF

Prediction of Life Expectancy for Terminally Ill Cancer Patients Based on Clinical Parameters (말기 암 환자에서 임상변수를 이용한 생존 기간 예측)

  • Yeom, Chang-Hwan;Choi, Youn-Seon;Hong, Young-Seon;Park, Yong-Gyu;Lee, Hye-Ree
    • Journal of Hospice and Palliative Care
    • /
    • v.5 no.2
    • /
    • pp.111-124
    • /
    • 2002
  • Purpose : Although the average life expectancy has increased due to advances in medicine, mortality due to cancer is on an increasing trend. Consequently, the number of terminally ill cancer patients is also on the rise. Predicting the survival period is an important issue in the treatment of terminally ill cancer patients since the choice of treatment would vary significantly by the patents, their families, and physicians according to the expected survival. Therefore, we investigated the prognostic factors for increased mortality risk in terminally ill cancer patients to help treat these patients by predicting the survival period. Methods : We investigated 31 clinical parameters in 157 terminally ill cancer patients admitted to in the Department of Family Medicine, National Health Insurance Corporation Ilsan Hospital between July 1, 2000 and August 31, 2001. We confirmed the patients' survival as of October 31, 2001 based on medical records and personal data. The survival rates and median survival times were estimated by the Kaplan-Meier method and Log-rank test was used to compare the differences between the survival rates according to each clinical parameter. Cox's proportional hazard model was used to determine the most predictive subset from the prognostic factors among many clinical parameters which affect the risk of death. We predicted the mean, median, the first quartile value and third quartile value of the expected lifetimes by Weibull proportional hazard regression model. Results : Out of 157 patients, 79 were male (50.3%). The mean age was $65.1{\pm}13.0$ years in males and was $64.3{\pm}13.7$ years in females. The most prevalent cancer was gastric cancer (36 patients, 22.9%), followed by lung cancer (27, 17.2%), and cervical cancer (20, 12.7%). The survival time decreased with to the following factors; mental change, anorexia, hypotension, poor performance status, leukocytosis, neutrophilia, elevated serum creatinine level, hypoalbuminemia, hyperbilirubinemia, elevated SGPT, prolonged prothrombin time (PT), prolonged activated partial thromboplastin time (aPTT), hyponatremia, and hyperkalemia. Among these factors, poor performance status, neutrophilia, prolonged PT and aPTT were significant prognostic factors of death risk in these patients according to the results of Cox's proportional hazard model. We predicted that the median life expectancy was 3.0 days when all of the above 4 factors were present, $5.7{\sim}8.2$ days when 3 of these 4 factors were present, $11.4{\sim}20.0$ days when 2 of the 4 were present, and $27.9{\sim}40.0$ when 1 of the 4 was present, and 77 days when none of these 4 factors were present. Conclusions : In terminally ill cancer patients, we found that the prognostic factors related to reduced survival time were poor performance status, neutrophilia, prolonged PT and prolonged am. The four prognostic factors enabled the prediction of life expectancy in terminally ill cancer patients.

  • PDF

Study of the Impact of Light Through the Vitamin $B_{12}$/Folate Inspection (Vitamin $B_{12}$/Folate 검사 시 빛의 영향에 대한 고찰)

  • Cho, Eun Bit;Pack, Song Ran;Kim, Whe Jung;Kim, Seong Ho;Yoo, Seon Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.162-166
    • /
    • 2012
  • Purpose : Vitamin $B_{12}$ and Folate are for anemia work-up which is well known for its sensitivity of light; the screening manual also specifies to be careful with light conditions. According to this, our laboratory minimized the exposure of light when inspecting the Vitamin $B_{12}$ and Folate, but the exposure cannot be wholly blocked due to other various factors such as when conducting specimen segregation. Thus, this inspection is to identify to what extent light can influence and whether the exclusion of light is mandatory during the Vitamin $B_{12}$/Folate test. Materials and Methods : We have conducted two experiments of identifying the extent of light's influence when conducting the Vitamin $B_{12}$/Folate test and also when specimens are under preservation. These experiments were progressed with various concentrations of patients' specimens which were requested to our hospital in March 2012. The first experiment is to verify the results on Vitamin $B_{12}$/Folate dependent on light exposure during the experiment. In the process, we have compared the results of light exposure/exclusion during the incubation process after the reagent division. The second experiment is about the impact of light exposure on the results on Vitamin $B_{12}$/Folate during the preservation. For 1, 2, 7 days the light on the specimen were wholly blocked and were preserved under $-15^{\circ}C$ temperature refrigeration. Then, we compared the results of light-excluded specimen and the exposed one. Results : When conducting first experiment, there were no noticeable changes in the Standard and specimen's cpm, but for Vitamin $B_{12}$, the average result of specimen exposed to light increased 7.8% compare to that of excluded one's. Furthermore, in the significant level 0.05, the significance probability or the p-value was 0.251 which means it has no impact. For Folate, the result being exposed to light decreased 5.4%, the significance probability was 0.033 which means it has little impact. For the second preservation, the result was dependent on the light exposure. The first day of preservation of Vitamin $B_{12}$, the clinical material exposed to light was 11.6%, second day clinical material exposed to light was 10.8%, seventh day clinical material exposed to light increased 3.8%, the significance probability of the $1^{st}$, $2^{nd}$, $7^{th}$ day is 0.372, 0.033, 0.144 respectively, and which indicates that the $1^{st}$ and $7^{th}$ day seems to have no impact. For Folate's case, the clinical material exposed to light has increased 1.4% but hardly had impact, $2^{nd}$ day clinical material being exposed to light was 6.1%, $7^{Th}$ day clinical material being exposed to light decreased 5.2%. The significance probability of Folate on the $1^{st}$, $2^{nd}$, $7^{th}$ day is 0.378, 0.037, 0.217 respectively, and the $1^{st}$ day and the $7^{th}$ day seems to have no impact. Conclusion : After scrutinizing the impact of light exposure/exclusion, Vitamin $B_{12}$ has no impact, while Folate seems to have no noticeable influence but light exclusion is recommended due to its significance probability of 0.033 when conducting experiment. During the preservation, the $2^{nd}$ day result depend on the light exclusion seems to have impact or influence. However, to consider the complication of the experimental process, the experiment including technical errors is predictable. Hence, it is likely to have no impact of light. Nevertheless, it is recommendable to exclude the light during the long preservation as per the significance probability (p-value) of $1^{st}$ and $7^{th}$ day has been diminished.

  • PDF

The Effect of PET/CT Images on SUV with the Correction of CT Image by Using Contrast Media (PET/CT 영상에서 조영제를 이용한 CT 영상의 보정(Correction)에 따른 표준화섭취계수(SUV)의 영향)

  • Ahn, Sha-Ron;Park, Hoon-Hee;Park, Min-Soo;Lee, Seung-Jae;Oh, Shin-Hyun;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.77-81
    • /
    • 2009
  • Purpose: The PET of the PET/CT (Positron Emission Tomography/Computed Tomography) quantitatively shows the biological and chemical information of the body, but has limitation of presenting the clear anatomic structure. Thus combining the PET with CT, it is not only possible to offer the higher resolution but also effectively shorten the scanning time and reduce the noises by using CT data in attenuation correction. And because, at the CT scanning, the contrast media makes it easy to determine a exact range of the lesion and distinguish the normal organs, there is a certain increase in the use of it. However, in the case of using the contrast media, it affects semi-quantitative measures of the PET/CT images. In this study, therefore, we will be to establish the reliability of the SUV (Standardized Uptake Value) with CT data correction so that it can help more accurate diagnosis. Materials and Methods: In this experiment, a total of 30 people are targeted - age range: from 27 to 72, average age : 49.6 - and DSTe (General Electric Healthcare, Milwaukee, MI, USA) is used for equipment. $^{18}F$- FDG 370~555 MBq is injected into the subjects depending on their weight and, after about 60 minutes of their stable position, a whole-body scan is taken. The CT scan is set to 140 kV and 210 mA, and the injected amount of the contrast media is 2 cc per 1 kg of the patients' weight. With the raw data from the scan, we obtain a image showing the effect of the contrast media through the attenuation correction by both of the corrected and uncorrected CT data. Then we mark out ROI (Region of Interest) in each area to measure SUV and analyze the difference. Results: According to the analysis, the SUV is decreased in the liver and heart which have more bloodstream than the others, because of the contrast media correction. On the other hand, there is no difference in the lungs. Conclusions: Whereas the CT scan images with the contrast media from the PET/CT increase the contrast of the targeted region for the test so that it can improve efficiency of diagnosis, there occurred an increase of SUV, a semi-quantitative analytical method. In this research, we measure the variation of SUV through the correction of the influence of contrast media and compare the differences. As we revise the SUV which is increasing in the image with attenuation correction by using contrast media, we can expect anatomical images of high-resolution. Furthermore, it is considered that through this trusted semi-quantitative method, it will definitely enhance the diagnostic value.

  • PDF

Randomized Trial of Early Versus Late Alternating Radiotherapy/ Chemotherapy in Limited-Disease Patients with Small Cell Lung Cancer (국한성병기 소세포폐암 환자에서 조기 혹은 지연 교대 방사선-항암제치료의 전향적 비교연구)

  • Lee Chang Geol;Kim Joo Hang;Kim Sung Kyu;Kim Sei Kyu;Kim Gwi Eon;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.116-122
    • /
    • 2002
  • Purpose : A randomized prospective study was conducted to compare the efficacy of early or late alternating schedules of radiotherapy, and carboplatin and ifosfamide chemotherapy in patients with limited-disease small cell lung cancer. Materials and Methods: From August 1993 to August 1996, a total of 44 patients with newly diagnosed, limited-disease small cell lung cancer, PS $H0\~2$, wt $loss<10\%$ were enrolled in a randomized trial which compared early alternating radiotherapy (RT)/chemotherapy (CT) and late alternating RT/CT. The CT regimen included ifosfamide $1.5\;g/m^2$ IV, d1-5 and carboplatin AUC 5/d IV, d2 peformed at 4 week intervals for a total of 6 cycles. RT (54 Gy/30 fr) was started after the first cycle of CT (early arm, N=22) or after the third cycle of CT (late arm, N=22) with a split course of treatment. Results : The pretreatment characteristics between the two arms were well balanced. The response rates in the early $(86\%)$ and late $(85\%)$ arm were similar. The median survival durations and 2-year survival rates were 15 months and $22.7\%$ in the early arm, and 17 months and $14.9\%$ in the late arm (p=0.47 by the log-rank test). The two-year progression free survival rates were $19.1\%$ in the early arm and $19.6\%$ in the late arm (p=0.52 by the log-rank test). Acute grade 3 or 4 hematologic and nonhematologic toxicities were similar between the two arms. Eighteen patients $(82\%)$ completed 6 cycles of CT in the early arm and 17 $(77\%)$ in the late arm. Four patients received less than 45 Gy of RT in the early arm and two in the late arm. There was no significant difference in the failure patterns. The local failure rate was $43\%$ in the early arm and $45\%$ in the late arm. The first site of failure was the brain in $24\%$ of the early arm patients compared to $35\%$ in the late arm (p=0.51). Conclusion : There were no statistical differences in the overall survival rate and the pattern of failure between the early and late alternating RT/CT in patients with limited-disease small cell lung cancer.

The studies on wrinkle recovery improvement for silk fabrics (견직물의 방추성 개선연구)

  • 김병호;정진영
    • Journal of Sericultural and Entomological Science
    • /
    • no.11
    • /
    • pp.23-29
    • /
    • 1970
  • This experiment is to improve the wrinkle recovery (W.R.) of silk fabrics. The silk fabrics is creased very well, and the crease is the serious defection of it. This experiment is to improve the nature by use of formaldehyde on fabrics. The reagents used were HCl, CH$_3$COOH, CaC$_2$, HCHO, Na$_2$CO$_3$, NH$_4$OH, NaOH and NaHCO$_3$. The silk fabrics was treated, to compare 1 he influence of conditions, by varying the quantities of reagents and the temperature of solution, and the reaction time. The cotton fabrics and the viscose rayon were sunk with the silk at the same condition to be compared the influence. 1) Those of the most suitable temperature to improve for the better W.R. are 75$^{\circ}C$ for silk, 35-45$^{\circ}C$ for cotton, and no particular temperature under 75$^{\circ}C$ for viscose rayon. 2) The W.R. improvements after treated at the temperature of 1) were 11% for silk and 33.4% for cotton. 3) There are the best treating time for every fabrics. They were 60 to 90 min. for viscose rayon when HAC Ras used for solvent. It took, however, 60min. of the best time for silk, 120 min. for cotton, and 40 min. for viscose rayon when acetic anhydride instead of HAC was used. 4) It was possible to improve 16.6% of W.R. for silk at the most suitable treating time, 25.0% for cotton, and 13.3% for viscose rayon. 5) Acetic anhydride was rather more effective to improve W.R. of both silk and viscose rayon than HAC. 6) Treating time was also shorter in case of using acetic anhydride than HAC. 7) The improvement of W.R. were 8.3% for silk at the 10 to 14 ml. of HCHO the best volume, 21. 5% for cotton at 18m!. of HCHO, and 70% of for viscose rayon at 14 to 18ml. of HCHO. 8) The most effective quantity of HCI is 14 ml. for both silk and cotton. The W.R. improvement of silk was 22.2%, and that of cotton 19.5%. 9) The W.R. of 83.3% the best for silk and 61. 6% for cotton were gained when 4.2gr. of NaHCO$_3$ brings down the percent of W.R. for both silk and cotton. 10) The more NaOH and NH$_4$OH as neutralizing agents, the less effectivity of W.R. until the quantities of the reagents are reached to a special range which are 3. 3m!. for silk and 3.3-6.6 ml. for cotton, and then we can see the W.R. increasing as the quantities of reagents are increased. These facts were evident in case of silk and cotton. We can also see with this fact that the reminder of 〔OH$\^$-/〕 neutralizing 〔CH$\^$+/〕in solution makes it possible to treat formaldehyde on fabrics. 11) Low curing temperature was comparatively better for silk, and high temperature better for cotton. 12) The result of this experiment shows that the Improvement of W.R. for silk was possible to 94% which means 22% W.R. increase compared to the untreated silk. This effect also shows that the improvement to W '||'&'||' W (wash and wear) of silk will be possible.

  • PDF

Studies on Raw Silk Test and Classification Comparative Studies on Winding Test and Classification between Korean and Japanese Method (생사검사방법 및 격부법에 관한 연구 재조검사의 비교연구 (1))

  • 김한수
    • Journal of Sericultural and Entomological Science
    • /
    • no.11
    • /
    • pp.81-86
    • /
    • 1970
  • This report was prepared to compare and analyze the testing method and classification of winding test in Korea to that in Japan, and the obtained results, which had been carried out, in Korea, from Sep. to Nov. in 1968 and in Japan through June in 1968, was as followings. 1. In Korean raw silk, (21 D.) the average number of breaks on winding test showed 5.91 by Korean Method but showed 8.6 by Japanese method and the latter increased to 2.7. On the other hand in Japanese raw silk, it showed 3.6 by Korean method but 4.7 by Japanese method and the latter increased to 1.1. (See Table 2,3) 2. It was seemed the tendency that the lot distribution of breaks number in Korean silk was mostly concentrated to the breaks No. 3,4 and 5(48%) by Korean method but in case of Japanese method to the breaks number 5,6 and 7(36%), and the tendency that the concentration depended mostly on the increased number of breaks. In Japanese raw silk, it was seemed the tendency that the lot distribution of breaks number was mostly concentrated to the breaks number 1. 2, and 3 (55%) by Korean Method but in case of Japanese Method to the breaks number, 2,3 and 4(50%) and the tendency that the concentration was as similar as the above. (See Table 2,3) 3. It was found the tendency that the distribution of breaks number during the open winding test was mostly concentrate red to the average number of breaks not only in Korea but in Japan. The rate 0: non-breaks, however, showed 43% of Japan, to 7% of Korea. (See Table 4) 4. Applying Table 1,2 to the Classification of Korea and Japan, the class distribution by Korean table showed 68% of class 1(6), 22% of cl ass 2(10) and 9% of class 3(15) in Korean silk, while that by Japanese table showed 13% of class 1(4), 56% of class 2(10) and 29% of class 3(18). And then the testing result to be class 1 or 2 by Korean table was. degraded from class 1 to class 2 of 55% and from class 2 to class 3 of 20% down. In Japanese silk, however, the class distribution by Korean table showed 85% of class 1 (4), 10% of class 2(10) and 5% of class 3(18) but that by Japanese table showed 60% of class 1(4), 33% of class 2(10) and 7% of class 3(18). And then there was little difference in the rate of class distribution. 5. Through the above investigation, it was seemed that Japanese classification table was only prepared for the r∼w silk of Japan, considering that the width of class 1(4) in winding table was greatly tighter than that of Korea. Because it was generally evaluated that Korean silk in quality especially in the winding test was better (next to Japan) than any other countries. 6. We could venture to estimate that, applying to Japanese method, the testing result of break number in Korean silk would show from about 6 by Korean method to 9. And then it would be found degrading hi the testing result of winding test increased gradually.

  • PDF