• 제목/요약/키워드: communication module

검색결과 2,089건 처리시간 0.038초

Development of Remote Control and Monitoring System for HID Street-lamp Based on Low Cost Zigbee Communication Network (저 가격형 Zigbee 통신 네트워크 기반 HID 가로등의 원격 제어 및 감시 시스템 개발)

  • Chung, Wan-Sup;Kim, Yang-Bae;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • 제63권2호
    • /
    • pp.69-73
    • /
    • 2014
  • In this paper, remote control and surveillance monitoring system of HID street-lamp using low-cost type of Zigbee communication module was developed. A plurality of capacitors with different capacity are attached to magnetic ballast for HID lamps. Changes in the amount of illumination can be adjusted by the changes in capacity so that the electric energy can be reduced. In Zigbee communication module, a ATmega128L microprocessor is used and in main CPU, ARM9 Core is used to construct a low-cost smart system. In surveillance monitoring systems, the system was configured to remote monitoring of presence of error in the lamp abnormalities, the status of leakage current and abnormalities of ballasts and capacitors and the validity of the proposed empirical experiment was confirmed.

The Implementation of SEED Cipher Algorithm Test Module Applied CMVP Test (CMVP 테스트를 적용한 SEED 암호 알고리즘 모듈 구현)

  • Park, Seong-Gun;Jeong, Seong-Min;Seo, Chang-Ho;Kim, Il-Jun;Shin, Seung-Jung;Kim, Seok-Woo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 한국정보처리학회 2003년도 춘계학술발표논문집 (하)
    • /
    • pp.1937-1940
    • /
    • 2003
  • 정보보호 평가는 크게 시스템 평가인 CC(Common Criteria)평가와 암호모듈 평가인 CMVP(Cryptographic Module Validation Program)평가로 나눌 수 있다. 본 논문은 국내 표준 암호 알고리즘 SEED를 북미의 CMVP의 3가지 블록 알고리즘 시험방법인 KAT(Known Answer Test), MCT(Monte C미개 Test), MMT(Multi-block Message Test)를 JAVA환경에 적용하여 시범 구현하였다. 테스트 방법으로 CMVP의 MOVS, TMOVS, AESAVS를 선정하여 FIPS 표준을 적용하였다. 구현 환경으로는 JCE기반의 Cryptix를 채택하여 CMVP의 블록 암호 알고리즘 테스트 시스템 중 일부를 구현하였다.

  • PDF

Data Conversion and Transmission Method for heterogeneous industrial device communication (이기종 산업기기 통신을 위한 데이터 변환 및 전송 방법)

  • Eum, Sang-hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 한국정보통신학회 2017년도 추계학술대회
    • /
    • pp.277-278
    • /
    • 2017
  • Recently, many industrial instruments face the problem of protocol compatibility with the external monitoring and control system. This paper implemented a protocol conversion algorithm for industrial monitoring about communication Data. This algorithm is supported programmable method by user. we experimented the protocol conversion by communication gateway module using implemented algorithm, and obtained good results.

  • PDF

A Protocol Conversion Algorithm for Monitoring of Industrial Communication Data (산업용 통신 데이터의 모니터링을 위한 프로그램 가능한 프로토콜 변환 알고리즘)

  • Eum, Sang-hee;Lee, Byong-hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 한국정보통신학회 2016년도 추계학술대회
    • /
    • pp.283-284
    • /
    • 2016
  • Recently, many industrial instruments face the problem of protocol compatibility with the external monitoring and control system. This paper implemented a protocol conversion algorithm for monitoring of industrial communication Data. This algorithm is supported programmable method by user. we experimented the protocol conversion by communication gateway module using implemented algorithm, and obtained good results.

  • PDF

A Study of Standard Diagnostic Communications Modules for ECU Diagnostic Communications (ECU 진단통신을 위한 표준 진단통신 모듈 연구)

  • Chang, Moon-Soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 한국정보통신학회 2022년도 춘계학술대회
    • /
    • pp.507-509
    • /
    • 2022
  • In order to collect vehicle internal diagnostic data, it is necessary to collect diagnostic data of ECU (Electronic Control Unit) included in various automotive parts. Diagnostic communication can be used to collect diagnostic data of ECU. In this paper, the method of collecting diagnostic data according to ECU function through standard diagnostic communication and the diagnostic communication module were analyzed. Among the standard modules of AUTOSAR, a standard for automotive electronics used by many automobile manufacturers, the diagnostic communication module was studied, and the process of diagnostic data processing through ECU was studied.

  • PDF

A Scheme on Internet-based Checking for Variant CNC Machines in Machine Shop

  • Kim, Dong-Hoon;Kim, Sun-Ho;Koh, Kwang-Sik
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1732-1737
    • /
    • 2004
  • This paper proposes Internet-based checking technique for machine-tools with variant CNC (Computerized Numerical Controller). According to the architecture of CNC, CNC is classified into two types such as CAC (Closed Architecture Controller) which is conventional CNC, and OAC (Open Architecture Controller) which is a recently introduced PC-based controller. CAC has a closed architecture and it is dependent on CNC vender specification. Because of this, it has been very difficult for users to implement an application programs in CNC domain. Therefore, an additionally special module is required for Internet-based application such as remote checking. In this case, web I/O embedded module can be efficiently applied for Internet-based checking. The module is directly attached to TCP/IP network for communication. In order to obtain the monitoring data of CNC machines, the I/O signals of the module are assigned to PLC (Programmable Logic Controller) input and output (I/O) signals within CNC domain. On the other hand, OAC has a PC-based open architecture and an additional module is not necessary for the connection with external site. Because of this, a simple DAU is just used for signal sensing and data acquisition without additional communication modules. For Internet-based remote checking of machine-tools with OAC, a user-defined daemon and application programs are implemented as the form of internal function within the PC-based controller. Internet communication is performed between the daemon program in CNC domain and web script programs in external server. Checking points defined in this research are classified into two categories such as structured point and operational point. The formal includes the vibration of bearing, temperature of spindle unit and another periodical management. And the latter includes oil checking, clamp locking/unlocking and machining on/off status.

  • PDF

Design and Implementation of a System Call Interface for Supporting File Partial Encryption (파일 부분 암호화 지원을 위한 시스템 호출의 설계 및 구현에 관한 연구)

  • Seo, Hye-In;Kim, Eun-Gi
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • 제22권3호
    • /
    • pp.557-567
    • /
    • 2018
  • There are currently various file encryption solutions for encrypting and storing files on disk. However, the existing file encryption solutions handle encryption and decryption all at once by file or directory. In this paper, we propose a system call supporting partial encryption function of the file. The user sets the encryption information with the system call interface at a portion where encryption of the file data is desired. And then the user writes file data, the data is encrypted and stored. Also if the user sets decryption information and reads the file data, the necessary part is decrypted by applying the set information. For the proposed system call, It consists of inspection module, management module, encryption module, decryption module, and HMAC module as per required system call. And it was implemented on the Linux environment. Also the operation of implemented system call was verified on the development board, and the performance was analyzed by measuring performance speed.

Design and Implementation of Cattle Estrus Detection System based on Wireless Communication and Internet of Things (무선 통신과 사물인터넷 기반의 소 발정 관찰 시스템 설계 및 구현)

  • Lee, Ha-Woon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • 제13권6호
    • /
    • pp.1309-1316
    • /
    • 2018
  • Cattle estrus detection system based on Internet of Things is designed and implemented by using Arduino pro-mini, gyroscope, acceleration sensor, bluetooth master and slave module. The implemented system measures cattle's moving and the measured data are transmitted to the computer connected to RX module by bluetooth TX module. They are plotted in 2-dimensional graph on the computer monitor and the number of transition at each sensor axis are calculated from the graph. The detected and gathered data from the system are analyzed by the proposed algorithm to decide which cows are in the estrus or not. The method to apply bluetooth scatternet is shown and the proposed system can be used to increase the success rate of artificial insemination in normal estrus by detecting the cow's behaviors such as the number of jumping. In this paper, the implemented cattle behavior detecting the system(TX module) are strapped on cattle's leg and it measures the cattle behaviors for determining where that a cattle is estrus or not by the proposed algorithm.

Effects of Glass Texturing Structure on the Module Efficiency of Heterojunction Silicon Solar Cells

  • Park, Hyeongsik;Lee, Yoo Jeong;Shin, Myunghun;Lee, Youn-Jung;Lee, Jaesung;Park, Changkyun;Yi, Junsin
    • Current Photovoltaic Research
    • /
    • 제6권4호
    • /
    • pp.102-108
    • /
    • 2018
  • A glass-texturing technique was developed for photovoltaic (PV) module cover glass; periodic honeycomb textures were formed by using a conventional lithography technique and diluted hydrogen fluoride etching solutions. The etching conditions were optimized for three different types of textured structures. In contrast to a flat glass substrate, the textured glasses were structured with etched average surface angles of $31-57^{\circ}$, and large aspect ratios of 0.17-0.47; by using a finite difference time-domain simulation, we show that these textured surfaces increase the amount of scattered light and reduce reflectance on the glass surface. In addition, the optical transmittance of the textured glass was markedly improved by up to 95% for wavelengths ranging from 400 to 1100 nm. Furthermore, applying the textured structures to the cover glass of the PV module with heterojunction with intrinsic thin-layer crystalline silicon solar cells resulted in improvements in the short-circuit current density and module efficiency from 39 to $40.2mA/cm^2$ and from 21.65% to 22.41%, respectively. Considering these results, the proposed method has the potential to further strengthen the industrial and technical competitiveness of crystalline silicon solar cells.

A Study on the Sensor Module System for Real-Time Risk Environment Management (실시간 위험환경 관리를 위한 센서 모듈시스템 연구)

  • Cho, Young Chang;Kwon, Ki Jin;Jeong, Jong Hyeong;Kim, Min Soo
    • Journal of IKEEE
    • /
    • 제22권4호
    • /
    • pp.953-958
    • /
    • 2018
  • In this study, a portable detection system was developed that can detect harmful gas and signals simultaneously in an enclosed space of industrial sites and underground facilities. The developed system is a sensor module for gas detection, a patch type 1 channel small ECG sensor, a module for three-axial acceleration detection sensor, and a system for statistics. In order to verify the performance of the system modules, the digital resolution, signal frequency, output voltage, and ultra-small modules were evaluated. As a result of the performance of the developed system, the digital resolution was 300 (rps) and the signal amplification gain was 500 dB or more, and the ECG module was manufactured with $50mm{\times}10mm{\times}10mm$ to increase patch utilization. It is believed that the product of this research will be valuable if it is used as an IoT-based management system for real-time monitoring of industrial workers.