• Title/Summary/Keyword: common zero

Search Result 238, Processing Time 0.029 seconds

New Strategy for Eliminating Zero-sequence Circulating Current between Parallel Operating Three-level NPC Voltage Source Inverters

  • Li, Kai;Dong, Zhenhua;Wang, Xiaodong;Peng, Chao;Deng, Fujin;Guerrero, Josep;Vasquez, Juan
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.70-80
    • /
    • 2018
  • A novel strategy based on a zero common mode voltage pulse-width modulation (ZCMV-PWM) technique and zero-sequence circulating current (ZSCC) feedback control is proposed in this study to eliminate ZSCCs between three-level neutral point clamped (NPC) voltage source inverters, with common AC and DC buses, that are operating in parallel. First, an equivalent model of ZSCC in a three-phase three-level NPC inverter paralleled system is developed. Second, on the basis of the analysis of the excitation source of ZSCCs, i.e., the difference in common mode voltages (CMVs) between paralleled inverters, the ZCMV-PWM method is presented to reduce CMVs, and a simple electric circuit is adopted to control ZSCCs and neutral point potential. Finally, simulation and experiment are conducted to illustrate effectiveness of the proposed strategy. Results show that ZSCCs between paralleled inverters can be eliminated effectively under steady and dynamic states. Moreover, the proposed strategy exhibits the advantage of not requiring carrier synchronization. It can be utilized in inverters with different types of filter.

Development of a Zero Velocity Detectable Sensor Algorithm with Dual Incremental Encoders (정지 속도 검출 가능한 이중 증분 엔코더 센서 알고리즘 개발)

  • Lee, Se-Han;Kim, Byoung-Chang
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.1
    • /
    • pp.82-88
    • /
    • 2009
  • The output of the encoder is a digital pulse, which is also easy to be connected to a digital controller. There are various angular velocity detecting methods of M, T, and M/T. Each of them has its own properties. There is a common limitation that the angular velocity detection period is strongly dependent on the destination velocity magnitude in case of ultimate low range. They have ultimately long detection period or cannot even detect angular velocity at near zero velocity. This paper proposes a zero velocity detectable sensor algorithm with the dual encoder system. The sensor algorithm is able to keep detection period moderately at near zero velocity and even detect zero velocity within nominal period. It is useful for detecting velocity in case of changing rotational direction at which there occurs zero velocity. In this paper, various experimental results are shown for the algorithm validity.

A New Active Zero State PWM Algorithm for Reducing the Number of Switchings

  • Yun, Sang-Won;Baik, Jae-Hyuk;Kim, Dong-Sik;Yoo, Ji-Yoon
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.88-95
    • /
    • 2017
  • To reduce common-mode voltage (CMV), various reduced CMV pulse width modulation (RCMV-PWM) algorithms have been proposed, including active zero state PWM (AZSPWM) algorithms, remote state PWM (RSPWM) algorithms, and near state PWM (NSPWM) algorithms. Among these algorithms, AZSPWM algorithms can reduce CMV, but they increase the number of switchings compared to the conventional space vector PWM (CSVPWM). This paper presents a new AZSPWM algorithm for reductions in both the CMV and total number of switchings in BLAC motor drives. Since the proposed AZSPWM algorithm uses only active voltage vectors for motor control, it reduces CMV by 1/3 compared to CSVPWM. The proposed AZSPWM algorithm also reduces the total number of switchings compared to existing AZSPWM algorithms by eliminating the switchings required from one sector to the next. The performance of the proposed algorithm is verified by analyses, simulations, and experimental results.

A Novel Soft Switching PWM·PFC AC·DC Boost Converter

  • Sahin, Yakup
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.256-262
    • /
    • 2018
  • This study introduces a novel Soft Switching (SS) Pulse Width Modulated (PWM) AC-DC boost converter. In the proposed converter, the main switch is turned on with Zero Voltage Transition (ZVT) and turned off with Zero Current Transition (ZCT). The main diode is turned on with Zero Voltage Switching (ZVS) and turned off with Zero Current Switching (ZCS). The auxiliary switch is turned on and off with ZCS. All auxiliary semiconductor devices are turned on and off with SS. There is no extra current or voltage stress on the main semiconductor devices. The majority of switching energies are transferred to the output by auxiliary transformer. Thus, the current stress of auxiliary switch is significantly reduced. Besides, the proposed converter has simple structure and ease of control due to common ground. The theoretical analysis of the proposed converter is verified by a prototype with 100 kHz switching frequency and 500 W output power. Furthermore, the efficiency of the proposed converter is 98.9% at nominal output power.

A Multi-Perspective Framework of Vision Zero: Toward Collaborative Promotion of Safety, Health and Well-Being at Work

  • Alanko, Tommi;Ruotsala, Riikka
    • Safety and Health at Work
    • /
    • v.13 no.3
    • /
    • pp.372-375
    • /
    • 2022
  • In the globalized field of safety, health, and well-being, the need to build multi-stakeholder alliances to find solutions to complex challenges is growing. This requires common ground for collaboration, as well as concepts and tools to grasp and manage the areas of interest. Over recent years, Vision Zero has awakened interest and it continues to evolve into many forms of approaches and initiatives, which provide a strategic direction and practical tools for supporting the development of safety, health, and well-being at work. Consequently, there is a need to build a shared understanding of 'zero'. This article reflects the potential of Vision Zero as a bridging concept and an approach for building multi-stakeholder collaboration. Thus, we present a multi-perspective framework of Vision Zero to support further dialoge and collaboration in joint undertakings.

Suggestion of the Characteristics of Element Technology and the Standard Model through the Comparison of Domestic Zero-energy Houses (국내 에너지제로하우스 비교를 통한 요소기술 특성 및 표준 모델 제시에 관한 연구)

  • Lee, Chung-Kook;Lee, Jeong-Cheol;Kim, Sang-Su;Suh, Seung-Jik
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.2
    • /
    • pp.27-35
    • /
    • 2012
  • Five zero energy house models developed in Korea for the purpose of the energy performance were compared and analyzed in the study. The standard passive house model applying common technology and efficient energy performance elements was proposed. Standard passive house 5 models have been developed commonly aiming at 100% energy saving, applying high-performance and high-efficiency exterior thermal insulation, using 3 low-e coated window system, and targeting average 0.65 ACH to enhance privacy. Energy recovery ventilators and dry and cold radiant heating floor has been partially applied. Eco-design techniques such as the awning device, heat insulating door, using natural light have been used. Solar and geothermal systems as the application of renewable energy technologies have been commonly applied. And fuel cells were applied to a partial model. The standard model based on common technical elements and average performance of each element and obtained from five model analysis has been proposed in the study.

Performance Comparison of Common-Mode Voltage Reduction PWM Methods in Terms of Modulation Index (변조지수에 따른 공통모드 전압 저감 PWM 기법 성능 비교)

  • Heo, Geon;Park, Yongsoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.2
    • /
    • pp.135-140
    • /
    • 2021
  • This study introduces a new pulse width modulation (PWM) method to reduce common-mode voltages (CMVs) and then compares its performance with other reduced CMV-PWM (RCMV-PWM) methods. CMVs should be reduced to ensure the electromagnetic compatibility and safety of grid-connected inverters. RCMV-PWM methods attempt to synthesize voltage references without zero vectors, which cause high CMV peaks. In these methods, the peak-to-peak magnitude of CMVs can be reduced by one-third of the conventional space-vector PWM. The introduced method splits every reference vector into two vectors to avoid the use of zero vectors. The performances of the RCMV-PWM methods are analyzed in accordance with the modulation index through simulation and experiment.

A Switching Technique for Common Mode Voltage Reduction of PWM-Inverter Induction Motor Drive System Using TMS320F240 (TMS320F240을 이용한 PWM 인버터 유도전동기 구동 시스템의 전도노이즈 저감을 위한 스위칭 기법)

  • 박규현;김이훈;원충연;김규식;최세완;함년근
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.89-97
    • /
    • 2003
  • High frequency common mode voltage produced by PWM inverter fed Induction motor is a major cause of conducted EMI, creation motor ground currents, bearing currents and other harmful products. The zero switching states of inverter control invoke large in comparison with the non-zero switching state of Inverter control. We proposed a common mode voltage reduction method based on sinusoidal PWM technique. PWM signal are generated by comparing respective sinusoidal reference signal with three triangular carrier wave displaced of 120$^{\circ}$. Simulation and experimenta1 result show that common mode voltages in the proposed PWM technique are reduced by approximate 66% more than conventional FWM technique.

Development of a High-Resolution Encoder System Using Dual Optical Encoders (이중 광학식 회전 엔코더 구조를 이용한 고정밀도 엔코더 시스템 개발)

  • Lee, Se-Han
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.9
    • /
    • pp.76-85
    • /
    • 2007
  • An optical rotary encoder is easy to implement for automatic control applications. In particular, the output of the encoder has a digital form pulse, which is also easy to be connected to a popular digital controller. By using the encoder, there are various angular velocity detecting methods, M-, T-, and M/T-method. Each of them has a property of its own. They have common limitation that the angular velocity detection period is strongly subject to the destination velocity magnitude in case of ultimate low range. They have ultimate long detection period or cannot even detect angular velocity at near zero velocity. This paper proposes a dual encoder system with two encoders of normal resolution. The dual encoder system is able to keep detection period moderately at near zero velocity and even detects zero velocity within nominal period. It is useful for detecting velocity in case of changing rotational direction at which there occurs zero velocity. In this paper, various experimental results are shown for the dual encoder system validity.

The System Architecture and Standardzation of Production IT Convergence for Smart Factory (스마트공장을 위한 IT 융합 표준화 동향 분석과 시스템 구조)

  • Cha, Suk Keun;Yoon, Jae Young;Hong, Jeong Ki;Kang, Hyun Gu;Cho, Hyeon Chan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.1
    • /
    • pp.17-24
    • /
    • 2015
  • Smart factory requires 4 Zero factors including Zero Waiting-time, Zero Inventory, Zero Defect, Zero Down-time) that needs IT convergence for production resources of 4M1E(Man, Machine, Material, Method, Energy) in real time and event processing in all type of manufacturing enterprises. This paper will be explaining about core emerging production IT convergence technologies including cyber device security, 4M1E integration, real time event driven architecture, common platform of manufacturing standard applications, smart factory to-be model for small and medium manufacturing enterprises.