• Title/Summary/Keyword: common ground

Search Result 670, Processing Time 0.027 seconds

Damage potential of earthquake records for RC building stock

  • Ozmen, Hayri Baytan;Inel, Mehmet
    • Earthquakes and Structures
    • /
    • v.10 no.6
    • /
    • pp.1315-1330
    • /
    • 2016
  • This study investigates ground motion parameters and their damage potential for building type structures. It focuses on low and mid-rise reinforced concrete buildings that are important portion of the existing building stock under seismic risk in many countries. Correlations of 19 parameters of 466 earthquake records with nonlinear displacement demands of 1056 Single Degree of Freedom (SDOF) systems are investigated. Properties of SDOF systems are established to represent RC building construction practice. The correlation of damage and ground motion characteristics is examined with respect to number of story and site classes. Equations for average nonlinear displacement demands of considered RC buildings are given for some of the ground motion parameters. Velocity related parameters are generally found to have better results than the acceleration, displacement and frequency related ones. Correlation of the parameters may be expected to decrease with increasing intensity of seismic event. Velocity Spectrum Intensity and Peak Ground Velocity have been found to have the highest correlation values for almost all site classes and number of story groups. Common parameter of Peak Ground Acceleration has lower correlation with damage when compared to them and some other parameters like Effective Design Acceleration and Characteristic Intensity.

MULTIVARIATE JOINT NORMAL LIKELIHOOD DISTANCE

  • Kim, Myung-Geun
    • Journal of applied mathematics & informatics
    • /
    • v.27 no.5_6
    • /
    • pp.1429-1433
    • /
    • 2009
  • The likelihood distance for the joint distribution of two multivariate normal distributions with common covariance matrix is explicitly derived. It is useful for identifying outliers which do not follow the joint multivariate normal distribution with common covariance matrix. The likelihood distance derived here is a good ground for the use of a generalized Wilks statistic in influence analysis of two multivariate normal data.

  • PDF

A Study on Lightning Overvoltage Characteristics of Grounding Systems in Underground Distribution Power Cables

  • Jung, Chae-Kyun;Jung, Yeon-Ha;Kang, Ji-Won
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.628-634
    • /
    • 2014
  • This paper investigates the transient characteristics of grounding systems used in under-ground distribution power cables. Recently, two kinds of grounding system are used for underground distribution cables in Korea. The first one is conventional multi-point grounding system, the other is newly proposed non-bundled common grounding system. The non-bundled common grounding system has an advantage the decreasing the power loss due to decrease of the shield circulation current. In this paper, the lightning overvoltage induced in neutral wire (in case of non-bundled common grounding system, overvoltage between opened neural wires and grounding in each phase) of these two kinds of grounding systems are estimated and compared by field tests and EMTP simulations. The EMTP simulation methods are firstly verified by comparison of measurement and simulation. Finally, the insulation level against lightning is expected by EMTP simulation results using verified model.

A Comparative Study of the Co management of Fishery Right by Fisheries Cooperatives - Centered on the Management of Fishing Ground through Eochon-gye - (수산업협동조합의 어업권관리기능에 대한 비교 연구 -어촌계의 어장관리활동을 중심으로-)

  • 최정윤
    • The Journal of Fisheries Business Administration
    • /
    • v.29 no.2
    • /
    • pp.21-46
    • /
    • 1998
  • The government is largely responsible for preventing “the tragedy of the common property”, but fisherman's effort fer an autonomous fishery control is equally required. Especially in these days of EEZ such self- regulated fishery management system should be developed and cared for as well. This study aimed to explore a proper management system for coastal fishing ground that now requires the responsible fisheries management by investigating and analysing more drastically the managerial functions of fishery right by Eochon-Gye(the smallest unit of fisheries cooperative based on a fishing village), a typical fishery producer's organization in Korea. This study also included such contents as (1) an understanding of fishery producer's organization, (2) the utilization and management system of coastal fishing ground, (3) the actual condition of fishing right distribution in Korea, (4) the fishery right management and activity of Eochon-Gye, (5) the operation and distinctive feature of fishery right in Japan, (6) the intervention and limit of fishery producer's organization for fishing ground management function, and (7) summary and proposal. We made all Eochon-Gye of the whole country an object of this study and carried out an investigation into Eochon-Gye through a questionnaire. We extracted 359 Eochon-Gye, 20% of the total 1,719 Eochon-Gye as a random sample and investigated these regions through a questionnaire by mail. The contents of the questions consist of 40 items, including six categories about the organization of eochon-gye, and fishing ground management and activities.

  • PDF

A Analysis of DC Control Circuit Transient and a Study of Auxiliary Relay Design Compatability in the Power Plant (발전소 직류 제어회로 과도현상 분석 및 보조계전기 선정 적합성 검토)

  • Seon, Hyun-Gyu;Hong, Young-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1948_1949
    • /
    • 2009
  • All the power generating station require dc auxiliary power systems to operate those dc components that must be available if a loss of ac power occur. Some examples of such components are auxiliary motors, circuit breakers, relays and solenoids. The dc source may be one common battery for both power and control or two separate batteries; one for power and another for control. Typically, a dc auxiliary power system is designed as an ungrounded system, instead of grounded system, so that a low-resistance ground fault on one of its two polarities will not affect the operation of the system, thus increasing system reliability and continuity of service. A ground detector should provide a high polarity-to-ground resistance so that a single ground fault occurring on the system will not affect the operation of that system. Sensitive relays have been known to energize momentarily while the cable and capacitive charge to ground shifts[1]. A power station had experienced this kind of incident and performed root cause analysis based on PC based simulation program known as PSpice. This simulation showed adapted relays on the system energize momentarily and design criteria on this relay should be corrected.

  • PDF

An Analysis Model of the Secondary Tunnel Lining Considering Ground-Primary Support-Secondary Lining Interaction (지반-1차지보재-2차라이닝의 상호작용을 고려한 터널 2차라이닝 해석모델)

  • 서성호;장석부;이상덕
    • Tunnel and Underground Space
    • /
    • v.12 no.2
    • /
    • pp.107-114
    • /
    • 2002
  • It is the common practice to over design the reinforcement for the secondary tunnel lining due to the lack of rational insight into the ground loosening loads. and due to the conservative application of the empirical design methods. The main loads of the secondary lining are the ground Loosening loads and the ground water pressure, and the ground load is critical in the reinforcement design of the secondary lining in the case of drained tunnel. If the external load is absent around a tunnel, the reasons of the load far secondary tunnel lining are the deterioration of the primary supports such as shotcrete, steel rib, and rockbolts. Accordingly, the analysis method considering the ground-primary supports-secondary lining interaction should be required tar the rational design of the secondary tunnel lining. In this paper, the interaction was conceptually described by the simple mass-spring model and the load transfer from the ground and primary supports to the secondary lining is showed by the ground-primary supports-secondary lining reaction curves fur the theoretical solution of a circular tunnel. And also, the application of this proposed model to numerical analysis is verified in order to check the potential far the tunnel with the complex analysis conditions.

Genetic Features of Lung Adenocarcinoma with Ground-Glass Opacity: What Causes the Invasiveness of Lung Adenocarcinoma?

  • Kim, Dohun;Lee, Jong-Young;Yoo, Jin Young;Cho, Jun Yeun
    • Journal of Chest Surgery
    • /
    • v.53 no.5
    • /
    • pp.250-257
    • /
    • 2020
  • Background: Lung adenocarcinoma (LUAD) with ground-glass opacity (GGO) can become aggravated, but the reasons for this aggravation are not fully understood. The goal of this study was to analyze the genetic features and causes of progression of GGO LUAD. Methods: LUAD tumor samples and normal tissues were analyzed using an Illumina HiSeq 4000 system. After the tumor mutational burden (TMB) was calculated, the identified mutations were classified as those found only in GGO LUAD, those present only in nonGGO LUAD, and those common to both tissue types. Ten high-frequency genes were selected from each domain, after which protein interaction network analysis was conducted. Results: Overall, 227 mutations in GGO LUAD, 212 in non-GGO LUAD, and 48 that were common to both tumor types were found. The TMB was 8.8 in GGO and 7.8 in non-GGO samples. In GGO LUAD, mutations of FCGBP and SFTPA1 were identified. FOXQ1, IRF5, and MAGEC1 mutations were common to both types, and CDC27 and NOTCH4 mutations were identified in the non-GGO LUAD. Protein interaction network analysis indicated that IRF5 (common to both tissue types) and CDC27 (found in the non-GGO LUAD) had significant biological functions related to the cell cycle and proliferation. Conclusion: In conclusion, GGO LUAD exhibited a higher TMB than non-GGO LUAD. No clinically meaningful mutations were found to be specific to GGO LUAD, but mutations involved in the epithelial-mesenchymal transition or cell cycle were found in both tumor types and in non-GGO tissue alone. These findings could explain the non-invasiveness of GGO-type LUAD.

Autilization and management of common octopus (Octopus minor) resources in the Tando bay on the southwest coast of Korea (한국 탄도만 낙지자원의 이용과 관리)

  • Oh, Taeg-Yun;Kim, Joo-Il;Seo, Young-Il;Lee, Sun-Kil;Cho, Mun-Seung;Joo, Hyun;Jeong, Sun-Beom
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.47 no.1
    • /
    • pp.18-26
    • /
    • 2011
  • This study is to contribute to income growth of fishermen by the common octopus fishery characterized in the Tando Bay on the southwest coast of Korea. This area is engaged in Longline fishing (301 persons), Shovel fishing (196 persons), Trap fishing (14 persons) and Torch light fishing (40 persons) in 2008. Population who is joined in the spring becomes main fishery target population of longline fishery in the fall because entering fishing ground in August, and is joined in the fall becomes main fishery target population of longline fishery in the spring because entering fishing ground in December. Average size of common octopus examined by longline 6.26cm, 5.82cm for Shovel fishing, 8.09cm for trap, and expressed big difference by fishery. It needs necessary various kinds of Octopus resource management actions and methods in continuous use. Specially, Fishing force increased by fishing automation system, so the reduction of fishing force is needed to increased by fishing force. Government support and fishermen's self-conscious of resource management is needed.

Aeronautical Link Availability Analysis for the Multi-Platform Image & Intelligence Common Data Link (다중 플랫폼 영상정보용 공용 데이터링크의 링크 가용도 성능 분석)

  • Ryu, Young-Jae;Ryu, Jung-Hun;Pak, Ui-Young
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37C no.10
    • /
    • pp.965-976
    • /
    • 2012
  • Multi-Platform Image and Intelligence Common data link(MPI-CDL) systems are designed to transmit the imaginary and signal intelligence data at an aeronautical to ground line of sight(LOS) link. This paper proposes a method to predict a link availability and analyzes the required link margin to satisfy a given link availability for MPI-CDL systems. To estimate a link availability the proposed method applies the conditional probability so that both a rain attenuation and a multipath fading are considered simultaneously. Link margins to meet the link availability for MPI-CDL systems are calculated according to an operating environment including frequencies, flight altitudes and transmission ranges. The required link margins for actual unmanned air vehicle systems are also given by simulation results.

A Study on the Effective Surge Protection Method from Induced Lightning Surge to Improve Isolate Grounding to Common Grounding (낙뢰 Surge 방호를 위한, 독립접지를 공통접지로 개선하는 효율적인 방법에 대한 연구)

  • Woo, Jea-Wook
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2013.10a
    • /
    • pp.215-218
    • /
    • 2013
  • This paper proposes the effective method to improve the protection from induced lightning surge by making common grounding from individual grounding. Common grounding under equipotential principle is more effective than individual grounding for lightning surge protection, and so common grounding is indicated as international technical standard under the AC power supply system with neutral line. So, this paper is to propose the effective way of induced lightning surge protection method for currently installed power supply system which has no neutral grounded line and individual grounding which are weak for lightning surge protection. This proposal can improve the power supply system as has neutral line, and improve the grounding system to common grounding system. And also this paper proposes to make effective equipotential system with voltage variable shunting devices for lightning surge protection.

  • PDF