• 제목/요약/키워드: commercial power

검색결과 2,022건 처리시간 0.032초

상용차를 위한 무시동 에어컨 압축기용 공진형 DC/DC 컨버터 개발 (Development of the Anti-Start Air Conditioner Compressor Resonant DC/DC Converter for Commercial Vehicle)

  • 한근우;김성곤;정영국;임영철
    • 전력전자학회논문지
    • /
    • 제19권6호
    • /
    • pp.557-563
    • /
    • 2014
  • This study deals with a resonant converter of an anti-start air conditioner compressor for commercial vehicles. The anti-start air conditioner compressor must generally have a high current, high efficiency, a low volume, and a low weight. To reduce the switching losses and voltage and current stresses of the device, the anti-start air conditioner compressor applies the full-bridge L-C resonant converter topology. Hardware parameters are designed to have a wide voltage range, and the switching frequency range of the L-C resonant converter is determined. Simulation is implemented using PSIM and an experiment is performed to verify the proposed converter.

고밀도 팽창흑연 성형품의 내열 특성에 관한 연구(1) (A Study on Thermostable Property of High Density Graphites Products with Expanded Graphite(1))

  • 신영우
    • 동력기계공학회지
    • /
    • 제9권4호
    • /
    • pp.148-154
    • /
    • 2005
  • Thermostable property is one of most important characteristics of graphite. Commercial graphites sheet from expanded graphite is using for high-temperature elements. Nowadays the new plant with high performance is developed in field of chemical industries, so the need of graphites is increasing rapidly. In this paper, the thermostable properties of newly developed graphite products with high density is investigated. I introduced the graphite material which developed for these heat tests by NGF method in order to test thermostable properties by comparing to the results of the commercial graphite sheet from expanded graphite in same condition. Through measuring the weight reducing ratio with various specimens in some conditions, I investigated the thermostable characteristics of these materials. It is verified that the graphite products by NGF method has almost same or superior thermostable properties comparing with that of commercial graphite sheet. Also the graphite products by NGF method have possibility of being better in thermostable properties.

  • PDF

풍력단지 제어를 위한 생산가능 출력에 대한 연구 (Study on the Available Power of a Wind Turbine for Wind Farm Control)

  • 오용운;백인수;남윤수;라요한
    • 한국태양에너지학회 논문집
    • /
    • 제34권1호
    • /
    • pp.1-7
    • /
    • 2014
  • A study on the available power of a wind turbine to be used for wind farm control was performed in this study, To accurately estimate the available power it is important to obtain a suitable wind which represents the three dimensional wind that the wind turbine rotor faces and also used to calculate the power. For this, two different models, the equivalent wind and the wind speed estimator were constructed and used for dynamic simulation using matlab simulink. From the comparison of the simulation result with that from a commercial code based on multi-body dynamics, it was found that using the hub height wind to estimate available power from a turbine results in high frequency components in the power prediction which is, in reality, filtered out by the rotor inertia. It was also found that the wind speed estimator yielded less error than the equivalent wind when compared with the result from the commercial code.

상용 휴대형 멀티미디어 재생기 전력소모 패턴 분석 (Analysis of Power Consumption Patterns for Commercial Portable Multimedia Players)

  • 남영진;양은주;이종열;김성률;서대화
    • 한국산업정보학회논문지
    • /
    • 제12권3호
    • /
    • pp.95-103
    • /
    • 2007
  • 데이터, 비디오, 오디오 등에 대한 디지털 컨버전스 추세와 함께, 최근 휴대용 멀티미디어 재생기(PMP)가 점차 대중화되고 있다. PMP는 DSP, 보다 큰 LCD 스크린, 하드디스크 등이 장착되는 이유로 다른 휴대형 장치들에 비해서 효과적인 전력관리에 대한 필요성이 강조되고 있다. 본 논문에서는 데이터수집 장치를 기반으로 한 하드웨어/소프트웨어기반 전력 측정 시스템 구축에 대해서 설명하고, PMP에서 발생하는 부팅, 동영상 재생, 다양한 비디오 코딩 방식 적용과 같은 다양한 사건 실행시의 전력소모 패턴을 측정하고 분석한다. 분석 결과는 저전력 PMP 장치를 설계하기 위한 유용한 정보를 제공한다.

  • PDF

상용차용 캐빈냉방기의 전산 열유동 해석 (Computational Thermal Flow Analysis of a Cabin Cooler for a Commercial Vehicle)

  • 김장권;오석형
    • 동력기계공학회지
    • /
    • 제16권2호
    • /
    • pp.17-23
    • /
    • 2012
  • The steady three-dimensional computational thermal flow analysis using standard k-${\varepsilon}$ turbulence model was carried out to investigate the heat transfer characteristics of a cabin cooler for a commercial vehicle. The heat exchanging method of this cabin cooler is to use the cooling effect of a thermoelectric module. In view of the results so far achieved, the air system resistance of a cabin cooler is about 12.4 Pa as a static pressure, and then the operating point of a cross-flow fan considering in this study is formed in the comparatively low flowrate region. The air temperature difference obtained from the cold part of an thermoelectric module is about $26^{\circ}C$, and the cooling water temperature difference obtained from the hot part of an thermoelectric module is about $3.5^{\circ}C$.

상용주파주의 LC공진을 이용한 단상고역률정류회로 (A single-phase high-power-factor rectifier using LC resonance in commercial frequenc)

  • 김주용;이상현;김영문;이현우;서기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.204-206
    • /
    • 2002
  • For small capacity rectifier circuits such as these for consumer electronics and appliances. capacitor input type rectifier circuits are generally used Consequently. various harmonics generated within the power system become a serious Problem. Various studies of this effect have been presented previously. However. most of these employ switching devices, such as FETs and the like. The absence of switching devices makes systems more tolerant to over -load, and brings low radio noise benefits. We propose a power factor correction scheme using a LC resonant in commercial frequency without switching devices. In this method. It makes a sinusoidal wave by widening conduction period using the current resonance in commercial frequency. Hence, the harmonic characteristics can be significantly improved. where the lower order harmonics. such as the fifth and seventh orders are much reduced. The result are confirmed by the theoretical and expermental implementations.

  • PDF

상용차 캐빈 내의 열전모듈에 의한 열유동 수치해석 (Numerical Analysis on the Thermal Flow by a Thermoelectric Module within the Cabin of a Commercial Vehicle)

  • 김장권;오석형
    • 동력기계공학회지
    • /
    • 제16권5호
    • /
    • pp.47-54
    • /
    • 2012
  • The steady three-dimensional numerical analysis on the thermal flow using standard k-${\varepsilon}$ turbulence model was carried out to investigate the air cooling effect of a cooler on the cabin for a commercial vehicle. Here, the heat exchanging method of this cabin cooler uses the cooling effect of a thermoelectric module. In consequence, the air system resistance of a cooler within the cabin is about 12.1 Pa as a static pressure, and then the operating point of a virtual cross-flow fan considering in this study is formed in the comparatively low flowrate region. The discharging air temperature of a cooler is about $14{\sim}15^{\circ}C$. Moreover, the air cooling temperature difference obtained under the outdoor cabin temperature of $40^{\circ}C$ shows about $7{\sim}9^{\circ}C$ in a driver resting space and about $9{\sim}14^{\circ}C$ in the front of a driver's seat including the space of a driver's foot.

저온 플라즈마 공정을 이용한 상용설비의 배연가스 처리 기술개발 (Technical Development of Flue Gas Control at Commercial Plant Using the Non-thermal Plasma Process)

  • 유정석;백민수;김태희;김정일;김유석;최석호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.939-944
    • /
    • 2001
  • For the application of simultaneous $DeSO_{2}\;&\;DeNO_{x}$ equipment using non-thermal plasma process to the industrial and power plants, the many types of plasma device and process were studied. The e-beam and pulsed plasma corona discharge process are outstanding for the study to apply commercial large-scale plant from among these. In this paper, non-thermal plasma of technical trends and the characteristics of system developed by Doosan heavy industries & construction Co., Ltd. are explained. We have researched pulsed plasma corona discharge process since 1994. At the basis of reasonable results for the pilot plant, we constructed the demonstration plant at a domestic coal-fired power plant in 1999, as the previous step for commercial use. In near future, enough information about designs and costs of commercial-size system will be obtained.

  • PDF

환경경영에서 건강신념모델을 이용한 병원환경이 대응성과 건강가치성을 통해 예방행동에 미치는 영향 (Effects of hospital environment using health belief model in environmental management on preventive behaviors through responsiveness and health value)

  • 장국현;황찬규;송영우
    • 디지털산업정보학회논문지
    • /
    • 제12권3호
    • /
    • pp.231-257
    • /
    • 2016
  • Several efforts to replace the use of existing fossil energy resources have already been made around the world. As a result, a new industry of renewable energy has been created, and efficient energy distribution and storage has been promoted intensively. Among the newly explored renewable energy sources, the most widely used one is solar energy generation, which has a high market potential. An energy storage system (ESS) is a system as required. In this paper, the design and implementation of an ESS for the efficient use of power in stand-alone street lights is presented. In current ESS applied to stand-alone street lights, either 12V~24V DC (from solar power) or 110V~220V AC (from commercial power) is used to recharge power in systems with lithium batteries. In this study, an ESS that can support both solar power and commercial power was designed and implemented; it can also perform emergency recharge of portable devices from solar powered street lights. This system can maximize the scalability of ESSes using lithium batteries with efficient energy conversion, with the advantage of being an eco-friendly technology. In a ripple effect, it can also be applied to smart grids, electric vehicles, and new, renewable storage markets where energy storage technology is required.