• 제목/요약/키워드: commercial pipe

검색결과 193건 처리시간 0.027초

표면 조도와 곡률 반경에 대한 U-자관 압력 손실의 상관관계 (THE CORRELATION OF PRESSURE DROP FOR SURFACE ROUGHNESS AND CURVATURE RADIUS IN A U-TUBE)

  • 박정후;장세명;이신영;장강원
    • 한국전산유체공학회지
    • /
    • 제20권1호
    • /
    • pp.39-46
    • /
    • 2015
  • In this research, we studied the pressure drop affecting on the internal surface roughness and the curvature radius of a U-tube, which is used for the cooling system in PWR(Pressurized Water Reactor). Using ANSYS-FLUENT, a commercial code based on CFD(Computational Fluid Dynamics) technique, we compared a Moody chart with the Darcy friction factor changed by a range of various surface roughness and Reynolds numbers of a straight pipe model. We studied the effect giving variation about a range of various surface roughness and the curvature radius of the full scale U-tube model. The material of the heat transfer tube is Inconel 690 used in the steam generator. We compared the velocity distribution of selected 4 locations, and derived the correlation between the surface roughness and the pressure drop for the U-tube of each representative curvature radius using the linear regression method.

Reynolds 방정식과 Hagen-Poiseuille 방정식의 연성해석을 통한 재순환홀을 갖는 유체동압베어링의 해석 (Coupled Analysis of the Fluid Dynamic Bearings with the Recirculation Channel by Solving the Reynolds and Hagen-Poiseuille Equations)

  • 강치호;장건희;정연하
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.760-767
    • /
    • 2014
  • This paper proposes a method to calculate pressure and flow of the fluid dynamic bearings (FDBs) with a recirculation channel (RC) by solving the Reynolds and the Hagen-Poiseuille equations at the same time. The Hagen-Poiseuille equation is one-dimensional equation which describes the flow in a circular pipe such as the RC. This research developed a finite element program to solve the Reynolds and the Hagen-Poiseuille equation together. The proposed method was applied to calculate the pressure and flow of the FDBs which are composed of grooved or plain journal and thrust bearings, and RC. To verify the proposed method, it also developed a finite volume model of the FDBs, and pressure and flow were calculated by the commercial CFD solver. They agree well with the pressure and flow calculated by the proposed method. Finally, this research investigated the characteristics of the FDBs due to the radius change of the RC.

  • PDF

질량 이동 모사 프로그램 개발을 위한 골드심 이동 패쓰웨이의 이해와 활용 (Understanding and Their Application of GoldSim Transport Pathways to Mass Trasport Simulation)

  • 이연명;정종태
    • 방사성폐기물학회지
    • /
    • 제12권2호
    • /
    • pp.135-151
    • /
    • 2014
  • 상용의 GoldSim과 GoldSim 이동 모듈 (GoldSim Transport Module; GTM)을 이용하여 방사성폐기물 처분시스템과 같이 복잡한 질량 이동 시스템을 신뢰성 있고 효율적으로 모사할 수 있다. 그러나 GTM의 특성을 보다 정확하게 이해하여야 이를 사용하여 실제 처분시스템의 안전성 평가 프로그램을 개발할 때 발생할 수 있는 오류를 피할 수 있다는 것을 인지하는 것이 중요하다. 이를 위하여 GTM에서 다양하게 제공되는 요소 (element) 중, 질량 이동 모사에 유용한 Transport pathway의 특징에 대하여 소개하고, 방사성폐기물 처분시스템 안전성 평가를 위해 시스템 내 핵종의 거동과 같은 질량 이동 모사에서 이에 대한 올바른 활용 방안을 제시하였다.

PCM을 활용한 구체축열시스템의 축열 및 방열 특성 연구 (Study on the Characteristics of Thermal Output and Thermal Storage in a Thermally Activated Building System with Phase Change Material)

  • 이현화;이수진;송진희;김수민;임재한;송승영
    • 설비공학논문집
    • /
    • 제25권12호
    • /
    • pp.647-653
    • /
    • 2013
  • TABS (Thermally Activated Building System) has recently applied by huge commercial buildings, airports, and convention centers in Europe. TABS provides night-time thermal storage by heating or cooling. The embedded water-based heating and cooling system uses the high thermal inertia of concrete in the building construction, in which a heating or cooling pipe is embedded. The aim of this study is to analyze the thermal storage and thermal output of TABS applied with PCM (Phase Change Material). To achieve this, prototypes of TABS and the thermal properties of various PCMs were investigated. By using the simulation program Physibel Voltra 6.0 W, the thermal storage and thermal output were evaluated according to a heating and cooling operation schedule.

공기 유압식 브레이크 라인 파손 사례 및 파손 분석 연구 (A Case Study on Failure and Analysis of Air Over Hydraulic Brake Line)

  • 박정만;박종진
    • 자동차안전학회지
    • /
    • 제12권2호
    • /
    • pp.47-55
    • /
    • 2020
  • In this case study, the brake line failure of air over hydraulic(AOH) brake system is described. AOH brake system is applied to commercial vehicles between 5 to 8 tons. It consists of a hydraulic system using compressed air and operates the air master to form hydraulic pressure to transfer braking power to the wheels. When the brake lines of the system applied to vehicles with high load capacity are damaged, the braking force of one shaft is lost, and the braking distance increases rapidly, leading to a big accident. Failure of the brake line occurs due to various causes such as road surface fragmentation, corrosion of the line, and aged deterioration of air brake hose. The braking force could be decreased even when a very small break in the form of a pin-hole occurs. However, it is difficult to find a part where the thickness of the line is thin due to stone pecking or corrosion generated in the pin-hole formed on the brake line located under the lower part of the vehicle by the sensory evaluation or the conventional braking force test. Accordingly, it is necessary to analyze the condition and cause of the failure of the brake line more precisely when the accident investigation of the heavy vehicles, and also to examine the necessity of the advanced test for the aged brake line.

냉이온수기 냉각시스템에 관한 열유동 해석 (Thermal-flow Analysis of the Cooling System in the Medicated Water Electrolysis Apparatus)

  • 전성오;이상준;이종철;김윤제
    • 한국유체기계학회 논문집
    • /
    • 제14권3호
    • /
    • pp.33-38
    • /
    • 2011
  • Medicated water electrolysis apparatus, which electrolyzes water into acidic water and alkaline water, was in the spotlight as becoming known the effect of alkaline water. It is known as good for health as removing active oxygen in the human's body and promoting digestion. But, the customers could not get that desired water temperature because these apparatuses are directly connected with a water pipe. So, the cooling system was developed for controlling the temperature of the alkaline water. One of the typical way is to store water in water tank and control the temperature. But, in this way, storing water can be polluted impurities coming from outside. For protecting this pollution, the cooling system based on indirect heat exchange method through phase change between water and ice was developed. In this study, we have calculated efficiency of the cooling system with phase change by experiment and commercial CFD(Computational Fluid Dynamics) code, ANSYS CFX. To consider the effect of latent heat that is generated by melting ice, we have simulated two phase numerical analyses used enthalpy method and found the temperature, velocity, and ice mass distribution for calculating the efficiency of cooling. From the results of numerical analysis, we have obtained the relationship between the cooling efficiency and each design factor.

차대동력계를 이용한 대형 디젤 차량의 매연 배출 특성 연구 (A Study on the Characteristics of Smoke Emissions from Heavy Duty Diesel Vehicles Using a Chassis Dynamometer)

  • 진광석;이충훈
    • 한국안전학회지
    • /
    • 제24권4호
    • /
    • pp.1-10
    • /
    • 2009
  • The characteristics of smoke emissions from diesel heavy duty vehicles which weigh over 5.5 tons was investigated by driving the vehicles with both the Lugdown 3 modes in the chassis dynamometer and tree accelerating mode under no load. The vehicles include commercial vehicles such as bus, microbus, trucks and specialized vehicles, etc. The total numbers of the vehicles tested were 200. The light extinction method was used to measure the smoke emissions from the vehicles tail pipe. The values of the smoke emissions in the tree accelerating mode showed $0{\sim}20%$ band nearly independent of both the mileage and year of production of the tested vehicles, while those in the Lugdown 3 modes showed $0{\sim}99%$ of wide band. The correlation coefficients between the values of the smoke emissions with both the Lugdown 3 modes and the free acceleration mode were 0.12, 0.08, 0.12, respectively. The inspection with Lugdown 3 modes is better one than that with tree acceleration from the point of exact inspection of the diesel vehicles' smoke emission.

급기가 되는 이중바닥 구조체의 열 성능 평가 (Estimation of the thermal performance on the double slab floor with supplying air)

  • 차광석;박명식;이대우;남우동
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.866-871
    • /
    • 2006
  • Recently according to the fashion of well-being, the case study of under floor heating system type for residential space is increasing. Specially double slab floor system can make several roles as reducing the acoustic noises and also supplying fresh air through the gap. So in present study floor heating performance was examined with various location of the space in the case of floor supply air and ceiling supply air. In both cases return air went out through ceiling opening. As one of the result is that when using the heat pipe type floor heating system the temperature difference between supply and return water was $15.2^{\circ}C$, but in case of commercial type floor heating system the temperature difference was $5.3^{\circ}C$ when the supply water temperature was $50^{\circ}C$.

  • PDF

아라미드 섬유강화 및 고무조성에 따른 콘크리트 도킹호스의 파열압력과 내마모도 특성 (Characteristics of Burst Pressure and Abrasion Resistance of Concrete Hose with Aramid Fiber Reinforcement and Rubber Composition)

  • 김용환;이승환;성일경;이여울;강명창
    • 한국기계가공학회지
    • /
    • 제17권6호
    • /
    • pp.105-110
    • /
    • 2018
  • A concrete docking hose of pump car's boom pipe line have been used in many construction sites. They are long structures with continuous cornering, similar to a trunk of the elephant, characterized by a very high pressure resistance of 20MPa. They need flexible materials and structure in order to move the hose smoothy. But commercial concrete hose is hard to handle and heavy owing to adaption of steel reinforcement. In this study, it is tried an experimental approach to the characteristic of inner rubber layer and abrasion resistance. Also, we are investigated the bursting pressure according to the reinforcement of the hose and propose the usefulness of the hose reinforced with high strengthened aramid fiber.

Low-frequency modes in the fluid-structure interaction of a U-tube model for the steam generator in a PWR

  • Zhang, Hao;Chang, Se-Myong;Kang, Soong-Hyun
    • Nuclear Engineering and Technology
    • /
    • 제51권4호
    • /
    • pp.1008-1016
    • /
    • 2019
  • In the SG (steam generator) of PWR (pressurized water reactor) for a nuclear plant, hundreds of U-shaped tubes are used for the heat exchanger system. They interact with primary pressurized cooling water flow, generating flow-induced vibration in the secondary flow region. A simplified U-tube model is proposed in this study to apply for experiment and its counterpart computation. Using the commercial code, ANSYS-CFX, we first verified the Moody chart, comparing the straight pipe theory with the results derived from CFD (computational fluid dynamics) analysis. Considering the virtual mass of fluid, we computed the major modes with the low natural frequencies through the comparison with impact hammer test, and then investigated the effect of pump flow in the frequency domain using FFT (fast Fourier transform) analysis of the experimental data. Using two-way fluid-structure interaction module in the CFD code, we studied the influence on mean flow rate to generate the displacement data. A feasible CFD method has been setup in this research that could be applied potentially in the field of nuclear thermal-hydraulics.