• Title/Summary/Keyword: commercial layer

Search Result 653, Processing Time 0.026 seconds

Numerical Study on the 300 MW Shell-type One-stage Entrained Flow Coal Gasifier Apllied with 4-Layer Slagging Model (4-Layer Slagging Model을 적용한 300 MW급 Shell형 1단 분류층 석탄 가스화기 전산수치해석)

  • Hong, Jung-Woo;Jeong, Hyo-Jae;Song, Ji-Hoon;Hwang, Jung-Ho
    • Journal of the Korean Society of Combustion
    • /
    • v.17 no.1
    • /
    • pp.1-11
    • /
    • 2012
  • A slag building simplified model was developed to determine wall heat flux of a Shell 300 MW coal gasifier. In the model 4 layers(particulate, sintered, molten slag, solidified slag) were considered and mass conservation and energy balance were used to obtain each slag layer's thickness and surface temperature. Thermo-chemical and fluid charateristics of the gasifier were studied with and without considering the slag model using commercial CFD code FLUENT. Consideration of the slag layer did not affect syn-gas mole fractions. However, the slag layer caused to increase the exit gas temperature by about 50 K.

Effects of Emulsifiers on the Properties of White Layer Cakes Prepared from Geurumil Flour (그루밀가루의 White Layer Cake 적성과 유화제 첨가 효과)

  • 경문식;장학길;이영택
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.30 no.5
    • /
    • pp.877-881
    • /
    • 2001
  • A domestic wheat variety (Geurumil flour) was evaluated for the properties of white layer cake, and compared to a commercial soft wheat flour. Geurumil flour contained more protein, ash, and lipid contents than commercial soft wheat flour. Very little difference in cake batter pH was observed between soft wheat flour and Geurumil flour, and the addition of emulsifiers tended to decrease the pH of Geurumil cake batter The specific gravity of the cake batter was lower in Geurumil flour than in soft wheat flour, and decreased effectively by the addition of emulsifiers due to batter aeration. Specific loaf volume was influenced by the addition of emulsifiers and demonstrated the highest values at the level of 1 ~ 2%. Addition of Ester-400 (monoglyceride) showed better cake properties in terms of volume, symmetry and uniformity index than sucrose-fatty acid ester did, and thus appeared to be more effective in improving baking performance. The changes in firmness of cakes during storage at $25^{\circ}C$ were observed, and Ester-400 showed some Positive effects on retarding cake staling.

  • PDF

The Organic-Inorganic Hybrid Encapsulation Layer of Aluminium Oxide and F-Alucone for Organic Light Emitting Diodes

  • Gwon, Deok-Hyeon;Seong, Myeong-Mo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.374-374
    • /
    • 2012
  • Nowadays, Active Matrix Organic Light-Emitting Diodes (AM-OLEDs) are the superior display device due to their vivid full color, perfect video capability, light weight, low driving power, and potential flexibility. One of the advantages of AM-OLED over Liquid Crystal Display (LCD) lies in its flexibility. The potential flexibility of AM-OLED is not fully explored due to its sensitivity to moisture and oxygen which are readily present in atmosphere, and there are no flexible encapsulation layers available to protect these. Therefore, we come up with a new concept of Inorganic-Organic hybrid thin film as the encapsulation layer. Our Inorganic layer is Al2O3 and Organic layer is F-Alucone. We deposited these layers in vacuum state using Atomic Layer Deposition (ALD) and Molecular Layer Deposition (MLD) techniques. We found the results are comparable to commercial requirement of 10-6 g/m2 day for Water Vapor Transmission Rate (WVTR). Using ALD and MLD, we can control the exact thin film thickness and fabricate more dense films than chemical or physical vapor deposition methods. Moreover, this hybrid encapsulation layer potentially has both the flexibility of organic layers and superior protection properties of inorganic layer.

  • PDF

Frictional Characteristics of Zn-Fe Alloy Electroplated Steel Sheets (Zn-Fe합금전기도금강판의 마찰특성)

  • 김영근;김명수
    • Journal of Surface Science and Engineering
    • /
    • v.28 no.1
    • /
    • pp.14-22
    • /
    • 1995
  • The effects of iron content in coated layer, surface roughness and lubricants on the formability of commercial Zn-Fe alloy electroplated steel sheets used for automotive bodies were investigated. The higher the iron content in deposit, the lower the friction coefficient of Zn-Fe alloy electroplated steel sheets. The surface roughness of coated layer hardly influenced the frictional characteristics. The formability of Zn-Fe alloy electroplated steel sheets was found to be more affected by the lubricant than by iron content in Zn-Fe alloy electrodeposit.

  • PDF

Comparison of the Impact of an Optimized Ice Cooling Vest and a Paraffin Cooling Vest on Physiological and Perceptual Strain

  • zare, Mansoor;dehghan, Habibollah;yazdanirad, Saeid;khoshakhlagh, Amir hossein
    • Safety and Health at Work
    • /
    • v.10 no.2
    • /
    • pp.219-223
    • /
    • 2019
  • Background: Ice cooling vests can cause tissue damage and have no flexibility. Therefore, these two undesirable properties of ice cooling vest were optimized, and the present study was aimed to compare the impact of the optimized ice cooling vest and a commercial paraffin cooling vest on physiological and perceptual strain under controlled conditions. Methods: For optimizing, hydrogel was used to increase the flexibility and a layer of the ethylene vinyl acetate foam was placed into the inside layer of packs to prevent tissue damage. Then, 15 men with an optimized ice cooling vest, with a commercial paraffin cooling vest, and without a cooling vest performed tests including exercise on a treadmill (speed of 2.8 km/hr and slope of %0) under hot ($40^{\circ}C$) and dry (40 %) condition for 60 min. The physiological strain index and skin temperature were measured every 5 and 15 minutes, respectively. The heat strain score index and perceptual strain index were also assessed every 15 minutes. Results: The mean values of the physiological and perceptual indices differed significantly between exercise with and without cooling vests (P < 0.05). However, the difference of the mean values of the indices except the value of the skin temperature during the exercises with the commercial paraffin cooling vest and the optimized ice cooling vest was not significant (P > 0.05). Conclusions: The optimized ice cooling vest was as effective as the commercial paraffin cooling vest to control the thermal strain. However, ice has a greater latent heat and less production cost.

Evaluation of the Filtration Efficiency and Facial Inhalation Resistance of Various Commercial Masks (시중에 판매되는 다양한 비인증 마스크의 분진 포집효율과 안면부 흡기저항 평가)

  • Kang, Sohyun;Kim, Soomin;Yoon, Chung Sik;Lee, Kiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.3
    • /
    • pp.292-301
    • /
    • 2021
  • Objectives: Wearing medical masks has been recommended since the declaration of coronavirus disease-19 (COVID-19) as a pandemic disease. Certified medical masks are evaluated according to filtration efficiency and facial inhalation resistance. However, some people use non-certified common masks. This study aimed to evaluate various non-certified commercial masks based on the certification criteria for medical masks. Methods: Twenty mask products (three anti-droplet, three disposable dental, eight fashion, three cotton, and three children's masks) were selected. For performance evaluation, filtration efficiency and facial inhalation resistance tests were conducted. The evaluation method followed the certification method for KF-certified masks of the Ministry of Food and Drug Safety (MFDS) and the N95 respirator of the National Institute for Occupational Safety and Health (NIOSH). Results: None of the 20 masks met the KF94 certification standard set by the MFDS. Four and three masks respectively met the KF80 certification standard and the N95 standard of NIOSH. Filtration efficiency was significantly higher in three-layer masks than in single layer masks. Pleated-type masks had higher filtration efficiency than cone-type masks. There was no correlation between the structure of masks and facial inhalation resistance. Conclusion: While no masks complied with the KF94 certification standard, a few masks met the KF80 and the N95 certification standards of NIOSH. Although some people wear non-certified commercial masks, protection from aerosols is not guaranteed by such masks. Evaluation of the protection efficiency of non-certified mask against microbiological infection is needed for the prevention of infectious disease.

Relation of Luminance by Insulator and Phosphor Layer with Thin Type (형광층 및 절연층의 두께에 의한 휘도특성)

  • 박수길;조성렬;손원근;박대희;이주성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.85-88
    • /
    • 1998
  • Light-emitting diode(LEDs), diode arrays, and phosphor display panels are finding increased use in a variety of commercial applications. Present and anticipated application of these devices include solid state indicator(e.g., digital clocks, meter readout) and display systems(e.g., instrument panels, TV display), the application being determined by the light -output capability and size availability(cost) of the particular device. In this work, Phosphor based on ZnS:Cu are used. Relation by luminance with the thickness of insulating layer and phosphor layer are discussed. Increased thickness of insulating layer are stable on voltage to 300V. By considering thickness and voltage, optimal structure and thickness are investigated. Also in order to maximize even surface emission, various sieving process are introduced. Very similar phosphor particle size is selected. Luminance by various wave intensity is also investigated. 150cd/m$^2$ luminance are investigated in stable voltage and frequency.

  • PDF

A GIS, GPS, Database, Internet GIS $software{\copyright}$ The First Arabian GIS $Software\copyright}$

  • El-Shayal, Mohamed El-Sayed
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.695-697
    • /
    • 2006
  • Elshayal $Smart{\copyright}$ software is an almost First Arabian GIS $software{\copyright}$ which completely developed by Arabian developers team and independent of any commercial software package. The software current Features are View and Edit shape files, build new layers, add existing layers, remove layers, swap layers, save layers, set layer data sources, layer properties, zoom in & zoom out, pan, identify, selecting features, invert selection, show data table, data query builder, location query builder, build network, find shortest path, print map, save map image, copy map image to clipboard, save project map, edit move vertex, edit move features, snap vertexes, set vertex XY, move settings, converting coordinate system, applying VB script, copy selected features to another layer, move selected features to another layer, delete selected features, edit data table, modify table structure, edit map features, drawing new features, GPS tracking, 3D view, etc... The software expected Features are: Viewing raster image and image geo-referencing, read other map formats such as DXF Format and Tiger Line Format.

  • PDF

A Strady-State One-Dimensional Analysis of an Oxygen Electrode in Stationary and Flowing Liquid (정체 및 유동액체에서 산소전극의 안정상태 일차원적 해석)

  • 김태진
    • KSBB Journal
    • /
    • v.4 no.2
    • /
    • pp.150-156
    • /
    • 1989
  • The chaacterisitics of a commercial membrance-coverd electrode in air-saturated saline solution were investigated in terms of a steadystate one-dimensional model. The electrode system miiersed in an aqueous medium consists of three layers: an external concentration boundary layer, a membrance, and an inner electrolyte layer. The membrance can be permeabld to the water and impermeable to the ionic species. In stationary midium, the water migrates from the external medium to the inner electrolyte layer until a thermodynamic equilibrium is reached. In a following midium, however, there is a reverse direction of water movement due to the hyrodynamic pressure differential until both thickness of the electrolyte layer and the membrance are equal.

  • PDF