• 제목/요약/키워드: comfortable indoor-temperature

검색결과 81건 처리시간 0.03초

평균피부온도 분석을 통한 수면시 쾌적 실내 온도조건에 관한 연구 (Study on Comfortable Room Temperature using Mean Skin Temperature analysis in Sleeping)

  • 김동규;정용현
    • 수산해양교육연구
    • /
    • 제19권2호
    • /
    • pp.161-167
    • /
    • 2007
  • It is necessary to control the room temperature for comfortable and deep sleep during a tropical night. We need to investigate thermal transport and parameter between human and environment for comfortable sleep. Therefore this study is performed to evaluate the comfortable room temperature based on the change of skin temperature under variations in thermal conditions and several reports. Five female subjects of 20~22 years with similar sleeping pattern were participated for the experiment. The subjects arrived in chamber at 9 pm and adapted to thermal circumstances during 2 hours. The sensors was sticked in body for skin temperatures. If subjects fall asleep in chamber, lights off and then sleep during 8 hours.As results, indoor temperature range for comfort sleep was $23.9{\sim}28.4^{\circ}C$ based on comfort mean skin temperature. But considering transition of time, minimum indoor temperature was $21.6^{\circ}C$, $22.9^{\circ}C$, $24.1^{\circ}C$, $23.9^{\circ}C$ and maximum indoor temperature was $28.2^{\circ}C$, $30.1^{\circ}C$.

남한의 하계 인체보온치수에 따른 쾌적 실내온도 분포의 특성 (The Characteristics of Comfortable Indoor-Temperature Distribution according to Summer Clo-Unit in South Korea)

  • 강철성
    • 한국지역지리학회지
    • /
    • 제11권5호
    • /
    • pp.383-390
    • /
    • 2005
  • 인체보온지수와 열 평형식을 이용하여 남한의 하계 쾌적 실내온도 분포 특성을 분석하였다. 6월 하순은 $16{\sim}21^{\circ}C$, 7월 중순은 $18{\sim}23^{\circ}C$, 8월 상순은 $18{\sim}24^{\circ}C$의 분포를 나타낸다. 5월 하순에 대관령 지역과 남부 내륙지역이 비교적 인체보온지수 값이 높게 나타나 쾌적 실내온도가 다른 지역에 비해 낮게 나타나고 있는데, 이는 지형적 영향으로 기온저하와 풍속의 증가로 나타나는 현상이다. 7월 중순과 8월 상순은 매우 유사한 분포패턴이 나타나며, 대관령 지역을 중심으로 남서 내륙지역으로 등온선이 만곡하고, 이 중심축을 제외한 나머지 지역은 인체보온지수 값이 낮게 나타나, 쾌적 실내온도가 비교적 높게 나타난다. 그 원인은 장마 이후의 고온다습한 북태평양 기단의 영향을 받고 강한 일사를 받아 지면 복사열을 방출하기 때문이다.

  • PDF

안면 피부온도를 활용한 PMV 지표 기반 쾌적환경 조성의 타당성 연구 (The Validation Study of Shaping Comfortable Environments Based on the PMV Index Using Facial Skin Temperature)

  • 김보성;민윤기;신에스더;김진호
    • 감성과학
    • /
    • 제16권3호
    • /
    • pp.311-318
    • /
    • 2013
  • 본 연구는 인간의 생리적 지표 중 하나인 안면 피부온도를 활용하여 PMV 지표 값에 기반하여 조성된 쾌적/불쾌 실내 환경을 적절하게 구분할 수 있는지 그 타당성을 살펴보고자 하였다. 이를 위해 쾌적 실내 환경에 해당되는 PMV 지표 값을 기준으로 물리적 환경을 쾌적 실내 환경과 불쾌한 실내 환경으로 각각 구분하고, 구분된 환경내에서 재실자의 안면 피부온도를 측정하였다. 그 결과, PMV 지표 값으로 구분된 쾌적 실내 환경과 불쾌한 실내 환경에서의 재실자의 안면 피부온도가 서로 차이를 보이는 것으로 나타났다. 이는 안면 피부온도가 PMV 지표에 기반한 쾌적한 실내 환경 조성에 있어 활용될 수 있음을 시사한다. 그러나 쾌적한 실내 환경에 비해 불쾌한 실내 환경에서 안면 피부온도가 낮게 나타나는 결과를 통해 오히려 PMV 지표 값에 기반을 두고 조성되는 쾌적/불쾌환경이 타당하지 않을 수 있음도 시사한다.

  • PDF

교육시설의 실내환경 특성 분석에 관한 연구 (초등학교의 열 및 음환경 실측조사에 의한 사례연구) (Analysis of the Indoor Environmental Characteristics of Educational Facilities (Case Study of Thermal and Acoustical Environment of Elementary School by Field Measurement))

  • 조민관
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.59-65
    • /
    • 2007
  • This study is to propose the basic data for deciding remodeling of wornout educational facilities. In order of it, the indoor environmental standard, the actual conditions of thermal environment and sound insulation of walls were examined through field measurement in the subjected open elementary school(J school) and modernization model of elementary school(Y school) which they are located in Seoul. As the result, standard for indoor environmental factors of educational facilities which is established by Ministry of Education is not subdivided into indoor environmental performances considering usages and characteristics of classrooms for comfortable indoor environment. The vertical temperature difference in general classroom and in open classroom showed to be $11.2^{\circ}C$ and $12.1^{\circ}C$ respectively, while indoor temperature of special classroon was, on the whole, higher than that of any other classroom due to its specific heat flux of wall materials. The sound insulation performance of the masonry brick wall of classroom satisfied the minimum standard of AIJ, Architectural Institute of Japan, in the open elementary school and the modernization model of elementary school. That is to say, the movable partition wall between the classroom and the corridor disturbed students in their class in the open school.

지열히트펌프를 이용한 습식.건식 바닥난방 성능평가 연구 (A Study on Comparison of Capacity between Wet.Dry Floor Heating Systems Using Geothermal Heat Pump)

  • 이병두;이세진;이대우;오성해;남우동
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.567-570
    • /
    • 2009
  • The present study conducted comparative evaluation of wet dry floor heating systems using geothermal heat pump. Circulation hot water from geothermal heat pump which is $10{\sim}15^{\circ}C$ lower than that from boiler was used. In order to access indoor temperature ($25^{\circ}C$) it took 74 minutes for dry type and 247 minutes for wet type. Average floor temperature was $23.89^{\circ}C$ for wet type and $32.66^{\circ}C$ for dry type. Energy saving rate gradually increased by 66% after 138 minutes. In the results, for floor heating system using low temperature circulation water, wet type was not enough to meet stable and comfortable radiant floor heating due to low floor temperature and access time to indoor set temperature. While dry type was practicable for stable floor heating due to fast rise of indoor set temperature and comfortable floor temperature.

  • PDF

불균등 복사공간의 쾌적온도범위 설정에 관한 연구 (A Study on the Establishment of the Optimal Temperature Limits for Man's Thermal Comfort in an Asymmetric Radiant Space)

  • 손장열;공성훈;윤용진
    • 대한설비공학회지:설비저널
    • /
    • 제14권3호
    • /
    • pp.187-199
    • /
    • 1985
  • The low-temperatured radiant heating System like a panel heating system is recognized as nice means to make comfortable indoor environment. Perhaps, 'Ondol' would be a typical example of the Panel heating system. Nevertheless. Occupants in a radiantly heated Space which has an asymmetric radiant field may feel thermally discomfort due to the asymmetric radiation. The aim of this Study is to suggest the fundamental technical data for establishing Standards of thermally comfortable environment when designing a radiant heating System. Thermal distribution of indoor environment and the skin temperature of the occupants were measured at experimental room in KIER (Korea Institute of Energy and Resources). Whole/Regional thermal and comfort Sensation votes of the occupants were taken simultaneously in order to investigate the relationships between thermal environmental factor and the occupants' responses. The effect of an asymmetric radiation on thermal environment and the occupants' responses was analyzed by using a v.r.t.(vector radiant temperature). By this means, the thermally neutral limits for the ambient air temperature and the floor surface temperature by the occupants' responses were Obtained. And the recommended temperature limits of the indoor surface were derived from the experimental work and the theory of radiant and will provide thermal neutrality for man without any discomfort on the part of the body.

  • PDF

도시가스 사용 주택의 동절기 실내온열환경 평가 (Evaluation of Indoor Thermal Environment of Houses using for heating in winter)

  • 박석봉;이현우
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.125-131
    • /
    • 2005
  • This study identified satisfaction with gas heating and indoor thermal environment, targeting houses using gases for heating. 1) Thermal environment is relatively satisfactory except that indoor humidity is low. 2) A question that indoor temperature has to be decreased for saving energy was given and about two thirds of the respondents answered that temperature has to be lowered. When they were asked how to save energy 57% answered that they put on more clothes and 27% answered that they lower indoor temperature If consistent promotion on energy saving is implementer it's believed that energy can be effectively saved. 3) People wear simple clothes when they stay indoor because they think it is comfortable. However, for energy saving. they gave to wear warm clothes though they stay indoor.

전통온돌방의 실내온열환경 및 온열감에 관한 연구 (Evaluation of Indoor Thermal Environment and Thermal Sensation in Traditional Ondol Room)

  • 김난행;손장열
    • 한국주거학회논문집
    • /
    • 제15권2호
    • /
    • pp.19-25
    • /
    • 2004
  • The aim of the research was to evaluate the characteristics of indoor thermal environment and thermal sensation in the traditional Ondol room. Indoor thermal factors including air temperature, operative temperature, floor surface temperature, relative humidity, PMV, OT were measured, and survey was carried out to understand subjective responses of resident's related to indoor thermal environment in Ondol room. The analysed houses are: the Chung hyo dang(the head house of Ryu family in Andong) and the Pyeung won jung(the traditional house in Yesan). The purpose of the survey was to know the relationship between resident's sensation and thermal environmental indicators such as air temperature, relative humidity, floor surface temperature, OT. The experimental results have pointed out how Ondol room may lead to comfortable and uniform indoor thermal environments.

컴퓨터를 이용한 가정용 냉방기기의 실내쾌적조건 조절에 관한 실험적 연구 (An Experimental Study on the Comfortable Room Control Conditioning Using Personal Computer)

  • 조진호;이대우
    • 대한설비공학회지:설비저널
    • /
    • 제17권4호
    • /
    • pp.442-447
    • /
    • 1988
  • To keep comfortable indoor condition, the existing air conditioning system is controlled by the ON/OFF temperature controller. The PID control unit is developed to control temperature and humidity simultaneously, and the Air-conditioning control system is transferred from the ON/OFF temperature controller to the PID control unit for experiment. As a result of this experiment, the PID control unit reduced energy consumption compared with the ON/OFF control unit.

  • PDF

동계 이중외피와 내부식재에 의한 실내 온도 특성에 관한 연구 (The Characteristics of the winter season window and indoor temperature due to the indoor plant)

  • 윤영일;조주영
    • KIEAE Journal
    • /
    • 제15권5호
    • /
    • pp.107-112
    • /
    • 2015
  • Purpose: This study desires to investigate an effect of indoor temperature, humidity, and illuminance targeting a planting system of double-skin facade and cavity space adjacent to the outside within a certain period of winter. Through this, the study suggests a basic material about an energy conservation effect of double window system using planting to reduce heating load of a building in winter, so desires to contribute to indoor thermal comfort effect and illuminance correction study of double window and indoor plant. Method: Considering effects such as day and night climatic elements and air conditions in winter, illuminance measurement was conducted through a double-skin facade of space, a subject of the measurement, on the basis of practical residence time of a resident, and this study analyzed characteristics of indoor illuminance about this. The study measured and compared a change of insolation, dry-bulb temperature, and relative humidity at each indoor-outdoor measuring point, so measured and compared characteristics of an indoor temperature effect by elements of double-skin facade and indoor plant. Result: Through this study, the researcher could determine that indoor plant within double window in winter not only blocks solar radiation but also photosynthesizes, so is somewhat disadvantageous to winter thermal comfort reducing heating load. In addition, solar radiation going through interior plays a role to bring down somewhat high humidity to about 50% of reasonable humidity, so plays a direct role of maintenance of comfortable indoor space. Although there are effects such as blocking of solar radiation and temperature reduction, this has a positive influence on humidity control and proper illuminance distribution. The researcher could determine that illuminance, temperature, and humidity by solar radiation penetration for the whole measuring time play a role to supplement indoor environment mutually.