• 제목/요약/키워드: column-tree type

검색결과 13건 처리시간 0.021초

컬럼-트리 형식 철골모멘트 접합부의 모델링 변수제안 (Modeling Parameters for Column-Tree Type Steel Beam-Column Connections)

  • 안희태;김태완;유은종
    • 한국지진공학회논문집
    • /
    • 제27권1호
    • /
    • pp.59-68
    • /
    • 2023
  • The column-tree type steel beam-column connections are commonly used in East Asian countries, including Korea. The welding detail between the stub beam and column is similar to the WUF-W connection; thus, it can be expected to have sufficient seismic performance. However, previous experimental studies indicate that premature slip occurs at the friction joints between the stub and link beams. In this study, for the accurate seismic performance evaluation of column-tree type moment connections, a moment-slip model was proposed by investigating the previous test results. As a result, it was found that the initial slip occurred at about 25% of the design slip moment strength, and the amount of slip was about 0.15%. Also, by comparing the analysis results from models with and without the slip element, the influence of slip on the performance of overall beam-column connections was examined. As the panel zone became weaker, the contribution of slip on overall deformation became greater, and the shear demand for the panel zone was reduced.

Cyclic testing of weak-axis column-tree connections with formation of plastic hinge at beam splice

  • Oh, Keunyeong;Chen, Liuyi;Hong, Sungbin;Yang, Yang;Lee, Kangmin
    • Earthquakes and Structures
    • /
    • 제8권5호
    • /
    • pp.1039-1054
    • /
    • 2015
  • The purpose of this study was to evaluate the seismic performance of weak-axis column-tree type connections used in steel moment frames. These connections are composed of a shop-welded and fieldbolted steel structure and can improve welding quality. On this basis, column-tree type connections are widely used in steel moment resisting frames in Korea and Japan. In this study, splices designed with a semirigid concept regarding the seismic performance of column-tree connections were experimentally evaluated. The structures can absorb energy in an inelastic state rather than the elastic state of the structures by the capacity design method. For this reason, the plastic hinge might be located at the splice connection at the weak-axis column-tree connection by reducing the splice plate thickness. The main variable was the distance from the edge of the column flange to the beam splice. CTY series specimens having column-tree connections with splice length of 600 mm and 900 mm were designed, respectively. For comparison with two specimens with the main variable, a base specimen with a weak-axis column-tree connection was fabricated and tested. The test results of three full-scale test specimens showed that the CTY series specimens successfully developed ductile behavior without brittle fracture until 5% story drift ratio. Although the base specimen reached a 5% story drift ratio, brittle fracture was detected at the backing bar near the beam-to-column connection. Comparing the energy dissipation capacity for each specimen, the CTY series specimens dissipated more energy than the base specimen.

반복재하 실물대 실험에 의한 컬럼-트리(Column-Tree) 형식 철골 모멘트 접합부의 내진거동 연구 (Cyclic Seismic Testing of Full-Scale Column-Tree Type Steel Moment Connections)

  • 이철호;박종원
    • 한국강구조학회 논문집
    • /
    • 제10권4호통권37호
    • /
    • pp.629-639
    • /
    • 1998
  • 본 연구에서는 반복재하 실물대 실험에 의해 철골 모멘트접합부(column-tree 형식)의 내진거동을 평가하였다. 시험체는 $H-600{\times}200$ (보) 및 $H-400{\times}400$ (기둥) 계열의 SS41 (SS400) 압연형강으로 제작되었으며 보에 대한 패널존의 상대강도를 실험의 주요변수로 고려하였다. 본 실험결과에 의할 때 패널존의 강도가 클수록 열등한 내진성능을 보였다. 시험체의 모멘트 접합부에서 접합부의 파괴 이전까지 발휘된 총소성회전각은 1.8 (% rad)에서 3 (% rad) 범위에 있었다. 시험체의 접합부는 보플랜지 열영향부의 파단 또는 기둥플랜지 두께방향의 뽑힘으로 인하여 파괴되었다. 비록 제한된 실험자료이긴 하나 본 연구의 결과는 보에만 항복을 유발하는 것 보다는 패널존의 항복도 허용하는 것이 접합부의 전체적 소성변형능력을 높이는데 유리할 것임을 시사한다. 이러한 실험결과를 역학적으로 설명할 수 있는 모델도 제시하고자 하였다.

  • PDF

Cyclic testing of weak-axis steel moment connections

  • Lee, Kangmin;Li, Rui;Jung, Heetaek;Chen, Liuyi;Oh, Kyunghwan
    • Steel and Composite Structures
    • /
    • 제15권5호
    • /
    • pp.507-518
    • /
    • 2013
  • The seismic performance of six types of weak-axis steel moment connections was investigated through cyclic testing of six full-scale specimens. These weak-axis moment connections were the column-tree type, WUF-B type, FF-W type, WFP type, BFP-B type and DST type weak-axis connections. The testing results showed that each of these weak-axis connection types achieved excellent seismic performance, except the WFP and the WUF-B types. The WFP and WUF-B connections displayed poor seismic performance because a fracture appeared prematurely at the weld joint due to stress concentrations. The column-tree type connection showed the best seismic behavior such that the story drift ratio could reach 5%.

A new replaceable fuse for moment resisting frames: Replaceable bolted reduced beam section connections

  • Ozkilic, Yasin O.
    • Steel and Composite Structures
    • /
    • 제35권3호
    • /
    • pp.353-370
    • /
    • 2020
  • This paper describes a new type of replaceable fuse for moment resisting frames. Column-tree connections with beam splice connections are frequently preferred in the moment resisting frames since they eliminate field welding and provide good quality. In the column-tree connections, a part of the beam is welded to the column in the shop and the rest of the beam is bolted with the splice connection in the field. In this study, a replaceable reduced beam section (R-RBS) connection is proposed in order to eliminate welding process and facilitate assembly at the site. In the proposed R-RBS connection, one end is connected by a beam splice connection to the beam and the other end is connected by a bolted end-plate connection to the column. More importantly is that the proposed R-RBS connection allows the replacement of the damaged R-RBS easily right after an earthquake. Pursuant to this goal, experimental and numerical studies have been undertaken to investigate the performance of the R-RBS connection. An experimental study on the RBS connection was used to substantiate the numerical model using ABAQUS, a commercially available finite element software. Additionally, five different finite element models were developed to conduct a parametric study. The results of the analysis were compared in terms of the moment and energy absorption capacities, PEEQ, rupture and tri-axiality indexes. The design process as well as the optimum dimensions of the R-RBS connections are presented. It was also demonstrated that the proposed R-RBS connection satisfies AISC criteria based on the nonlinear finite element analysis results.

Effect of bolted splice within the plastic hinge zone on beam-to-column connection behavior

  • Vatansever, Cuneyt;Kutsal, Kutay
    • Steel and Composite Structures
    • /
    • 제28권6호
    • /
    • pp.767-778
    • /
    • 2018
  • The purpose of this study is to investigate how a fully restrained bolted beam splice affects the connection behavior as a column-tree connection in steel special moment frames under cyclic loading when located within the plastic hinge zone. The impacts of this attachment in protected zone are observed by using nonlinear finite element analyses. This type of splice connection is designed as slip-critical connection and thereby, the possible effects of slippage of the bolts due to a possible loss of pretension in the bolts are also investigated. The 3D models with solid elements that have been developed includes three types of connections which are the connection having fully restrained beam splice located in the plastic hinge location, the connection having fully restrained beam splice located out of the plastic hinge and the connection without beam splice. All connection models satisfied the requirement for the special moment frame connections providing sufficient flexural resistance, determined at column face stated in AISC 341-16. In the connection model having fully restrained beam splice located in the plastic hinge, due to the pretension loss in the bolts, the friction force on the contact surfaces is exceeded, resulting in a relative slip. The reduction in the energy dissipation capacity of the connection is observed to be insignificant. The possibility of the crack occurrence around the bolt holes closest to the column face is found to be higher for the splice connection within the protected zone.

약축 보-기둥 접합부의 경제성에 관한 연구 (A Study on the Economy of Weak-Axis Beam-to-Column Connections)

  • 박종원;강승민;오용준
    • 한국강구조학회 논문집
    • /
    • 제19권6호
    • /
    • pp.663-670
    • /
    • 2007
  • 국내의 경우 철골 보-기둥의 접합부에 브라켓 형식이 널리 사용되고 있다. 본 연구에서는 브라켓 형식의 접합부에서 약축방향의 접합부를 대상으로 접합부의 디테일을 바꿈으로서 보다 경제적이면서 동시에 기존의 접합 디테일을 사용한 접합부와 구조적으로 유사한 성능을 발휘할 수 있는 접합부를 개발하였다. 접합 디테일을 다르게 한 4개의 접합부를 제안하고 이에 대해 경제성을 비교하였다. 또한 제안된 접합형식의 구조적 성능을 검증하기 위해 기존 접합 디테일을 포함하여 총 다섯 개의 시험체를 제작하고 이에 대한 최대내력 실험연구를 수행하였다. 4개의 제안된 접합형식 모두 기존의 접합형식에 비해 경제적인 것으로 나타났으며 최대내력 실험의 경우 한 접합형식을 제외하고 모두 보의 소성모멘트를 발휘할 수 있었으며 기존의 접합형식과 유사한 충분한 변형특성을 발휘할 수 있는 것으로 나타났다.

기계학습 기반 철근콘크리트 기둥에 대한 신속 파괴유형 예측 모델 개발 연구 (Machine Learning-Based Rapid Prediction Method of Failure Mode for Reinforced Concrete Column)

  • 김수빈;오근영;신지욱
    • 한국지진공학회논문집
    • /
    • 제28권2호
    • /
    • pp.113-119
    • /
    • 2024
  • Existing reinforced concrete buildings with seismically deficient column details affect the overall behavior depending on the failure type of column. This study aims to develop and validate a machine learning-based prediction model for the column failure modes (shear, flexure-shear, and flexure failure modes). For this purpose, artificial neural network (ANN), K-nearest neighbor (KNN), decision tree (DT), and random forest (RF) models were used, considering previously collected experimental data. Using four machine learning methodologies, we developed a classification learning model that can predict the column failure modes in terms of the input variables using concrete compressive strength, steel yield strength, axial load ratio, height-to-dept aspect ratio, longitudinal reinforcement ratio, and transverse reinforcement ratio. The performance of each machine learning model was compared and verified by calculating accuracy, precision, recall, F1-Score, and ROC. Based on the performance measurements of the classification model, the RF model represents the highest average value of the classification model performance measurements among the considered learning methods, and it can conservatively predict the shear failure mode. Thus, the RF model can rapidly predict the column failure modes with simple column details.

고력볼트 접합이음 철골보의 탄소성거동 (Elasto-Plastic Behavior of Steel Beams with High Strength Bolted Splices)

  • 최성모;김진호;노원경
    • 한국강구조학회 논문집
    • /
    • 제15권5호통권66호
    • /
    • pp.531-539
    • /
    • 2003
  • 노스리지 지진 발생시 구조체 손상이 발생했던 현장용접 모멘트골조와 달리 기둥-보 브라켓형식의 모멘트골조에는 지진의 영향을 조정하고 감소시키는 도구(tool)가 바로 보에 이음부(splice)이다. 지진발생 중에 보의 이음부는 연성의 퓨즈(fuse)로서 작용할 수 있고, 골조에 발생할 수 있는 흼모멘트를 포함한 힘의 크기를 제한할 수 있다. 국내에서는 모멘트 골조의 대부분이 기둥-보 브라켓 형식으로 이루어진다. 본 논문에서는 이음하지 않은 H형강보를 제작하여 단순가력 실험을 수행하였고, 고력볼트를 이용하여 전강도설계된 실물실험체와 플랜지볼트 열수를 각각 75%, 50% 및 0%로 줄여서 이음부를 제작한 H형강 보를 단순가력 실험을 수행하였다. 이들 실험을 통해 기둥-보 브라켓형식의 모멘트 골조에서 보의 이음부(Beam Splice)가 악보(Week Beam)의 임계위치(Critical Point)로서 작용할 수 있는 가능성을 타진하고자 하는 연구에 기초자료를 제공하는 것이 본 연구의 목적이다.

과수재배용 온실의 구조유형과 설계요소 분석 (Analysis of Structural Types and Design Factors for Fruit Tree Greenhouses)

  • 남상운;고기혁
    • 생물환경조절학회지
    • /
    • 제22권1호
    • /
    • pp.27-33
    • /
    • 2013
  • 본 연구는 과수재배 시설의 표준화 및 환경조절기술개발을 위한 기초자료로 제공하는 것을 목적으로 과수재배용 온실의 실태를 조사하여 구조유형과 설계요소를 분석하고, 기상재해에 대한 안전성과 구조 및 환경관리에 대한 개선방안을 검토하였다. 시설재배 면적이 가장 많은 5개 품목 중 주로 제주도에서 재배되고 있는 감귤과 현재 재배온실을 찾을 수 없는 단감을 제외한 포도, 배 및 복숭아재배 온실을 연구대상으로 하였다. 감귤과 포도재배 온실은 꾸준히 증가하고 있으나 저장시설의 발달로 배와 단감재배 온실은 감소하고 있는 추세이다. 앞으로는 비가림 효과가 크고 저장성이 떨어지는 품목을 중심으로 과수재배 온실의 변화가 예상된다. 조사대상 온실 중 배 재배 온실과 복숭아재배 대형 단동온실을 제외하고는 대체로 보급형 온실의 규격을 따르고 있으며, 재배작목별로 특성화된 온실은 없는 것으로 나타났다. 과수재배 온실의 대부분은 농촌진흥청과 농림수산식품부에서 고시한 농가보급형 모델이나 내재해형 모델의 부재규격을 따르고 있었다. 기초는 대부분 콘크리트 기초를 사용하고 있었으며, 배 재배 온실의 경우에는 내재해형 모델보다 두꺼운 단면의 기둥을 사용하고, 강판을 기둥의 하단에 용접하여 매설한 형태의 특수한 기초를 적용하고 있었다. 조사대상 온실의 구조적 안전성을 검토한 결과 대부분 안전하였으나 김천과 천안의 포도재배 온실, 남원과 천안의 복숭아재배 온실에서 적설에 불안전한 것으로 나타났고, 남원의 복숭아재배 온실은 풍속에 대한 안전성도 부족한 것으로 나타났다. 또한 채소재배 온실을 복숭아재배로 전용한 온실의 경우 적설과 풍하중 모두 상당히 불안정한 것으로 나타났다. 과수의 수형, 수고 및 재식간격을 고려하여 과수 재배 온실의 적정규격을 검토한 결과 포도재배 온실은 폭 7.0~8.0m, 측고 2.5~2.8m가 적당하고, 배와 복숭아재배 온실은 폭 6.0~7.0m, 측고 3.0~3.3m 정도가 적당한 것으로 판단된다.