• 제목/요약/키워드: column-tree

검색결과 93건 처리시간 0.027초

Cyclic testing of weak-axis column-tree connections with formation of plastic hinge at beam splice

  • Oh, Keunyeong;Chen, Liuyi;Hong, Sungbin;Yang, Yang;Lee, Kangmin
    • Earthquakes and Structures
    • /
    • 제8권5호
    • /
    • pp.1039-1054
    • /
    • 2015
  • The purpose of this study was to evaluate the seismic performance of weak-axis column-tree type connections used in steel moment frames. These connections are composed of a shop-welded and fieldbolted steel structure and can improve welding quality. On this basis, column-tree type connections are widely used in steel moment resisting frames in Korea and Japan. In this study, splices designed with a semirigid concept regarding the seismic performance of column-tree connections were experimentally evaluated. The structures can absorb energy in an inelastic state rather than the elastic state of the structures by the capacity design method. For this reason, the plastic hinge might be located at the splice connection at the weak-axis column-tree connection by reducing the splice plate thickness. The main variable was the distance from the edge of the column flange to the beam splice. CTY series specimens having column-tree connections with splice length of 600 mm and 900 mm were designed, respectively. For comparison with two specimens with the main variable, a base specimen with a weak-axis column-tree connection was fabricated and tested. The test results of three full-scale test specimens showed that the CTY series specimens successfully developed ductile behavior without brittle fracture until 5% story drift ratio. Although the base specimen reached a 5% story drift ratio, brittle fracture was detected at the backing bar near the beam-to-column connection. Comparing the energy dissipation capacity for each specimen, the CTY series specimens dissipated more energy than the base specimen.

Cyclic testing of steel column-tree moment connections with various beam splice lengths

  • Lee, Kangmin;Li, Rui;Chen, Liuyi;Oh, Keunyeong;Kim, Kang-Seok
    • Steel and Composite Structures
    • /
    • 제16권2호
    • /
    • pp.221-231
    • /
    • 2014
  • The purpose of this study was to evaluate the cyclic behavior of steel column-tree moment connections used in steel moment resisting frames. These connections are composed of shop-welded stub beam-to-column connection and field bolted beam-to-beam splice. In this study, the effects of beam splice length on the seismic performance of column-tree connections were experimentally investigated. The change of the beam splice location alters the bending moment and shear force at the splice, and this may affect the seismic performance of column-tree connections. Three full-scale test specimens of column-tree connections with the splice lengths of 900 mm, 1,100 mm, and 1,300 mm were fabricated and tested. The splice lengths were roughly 1/6, 1/7, 1/8 of the beam span length of 7,500 mm, respectively. The test results showed that all the specimens successfully developed ductile behavior without brittle fracture until 5% radians story drift angle. The maximum moment resisting capacity of the specimens showed little differences. The specimen with the splice length of 1,300 mm showed better bolt slip resistance than the other specimens due to the smallest bending moment at the beam splice.

컬럼-트리 형식 철골모멘트 접합부의 모델링 변수제안 (Modeling Parameters for Column-Tree Type Steel Beam-Column Connections)

  • 안희태;김태완;유은종
    • 한국지진공학회논문집
    • /
    • 제27권1호
    • /
    • pp.59-68
    • /
    • 2023
  • The column-tree type steel beam-column connections are commonly used in East Asian countries, including Korea. The welding detail between the stub beam and column is similar to the WUF-W connection; thus, it can be expected to have sufficient seismic performance. However, previous experimental studies indicate that premature slip occurs at the friction joints between the stub and link beams. In this study, for the accurate seismic performance evaluation of column-tree type moment connections, a moment-slip model was proposed by investigating the previous test results. As a result, it was found that the initial slip occurred at about 25% of the design slip moment strength, and the amount of slip was about 0.15%. Also, by comparing the analysis results from models with and without the slip element, the influence of slip on the performance of overall beam-column connections was examined. As the panel zone became weaker, the contribution of slip on overall deformation became greater, and the shear demand for the panel zone was reduced.

반복재하 실물대 실험에 의한 컬럼-트리(Column-Tree) 형식 철골 모멘트 접합부의 내진거동 연구 (Cyclic Seismic Testing of Full-Scale Column-Tree Type Steel Moment Connections)

  • 이철호;박종원
    • 한국강구조학회 논문집
    • /
    • 제10권4호통권37호
    • /
    • pp.629-639
    • /
    • 1998
  • 본 연구에서는 반복재하 실물대 실험에 의해 철골 모멘트접합부(column-tree 형식)의 내진거동을 평가하였다. 시험체는 $H-600{\times}200$ (보) 및 $H-400{\times}400$ (기둥) 계열의 SS41 (SS400) 압연형강으로 제작되었으며 보에 대한 패널존의 상대강도를 실험의 주요변수로 고려하였다. 본 실험결과에 의할 때 패널존의 강도가 클수록 열등한 내진성능을 보였다. 시험체의 모멘트 접합부에서 접합부의 파괴 이전까지 발휘된 총소성회전각은 1.8 (% rad)에서 3 (% rad) 범위에 있었다. 시험체의 접합부는 보플랜지 열영향부의 파단 또는 기둥플랜지 두께방향의 뽑힘으로 인하여 파괴되었다. 비록 제한된 실험자료이긴 하나 본 연구의 결과는 보에만 항복을 유발하는 것 보다는 패널존의 항복도 허용하는 것이 접합부의 전체적 소성변형능력을 높이는데 유리할 것임을 시사한다. 이러한 실험결과를 역학적으로 설명할 수 있는 모델도 제시하고자 하였다.

  • PDF

내부점방법을 위한 초마디 열촐레스키 분해의 실험적 고찰 (Experimental Study on Supernodal Column Choleksy Factorization in Interior-Point Methods)

  • 설동렬;정호원;박순달
    • 경영과학
    • /
    • 제15권1호
    • /
    • pp.87-95
    • /
    • 1998
  • The computational speed of interior point method depends on the speed of Cholesky factorization. The supernodal column Cholesky factorization is a fast method that performs Cholesky factorization of sparse matrices with exploiting computer's characteristics. Three steps are necessary to perform the supernodal column Cholesky factorization : symbolic factorization, creation of the elimination tree, ordering by a post-order of the elimination tree and creation of supernodes. We study performing sequences of these three steps and efficient implementation of them.

  • PDF

A new replaceable fuse for moment resisting frames: Replaceable bolted reduced beam section connections

  • Ozkilic, Yasin O.
    • Steel and Composite Structures
    • /
    • 제35권3호
    • /
    • pp.353-370
    • /
    • 2020
  • This paper describes a new type of replaceable fuse for moment resisting frames. Column-tree connections with beam splice connections are frequently preferred in the moment resisting frames since they eliminate field welding and provide good quality. In the column-tree connections, a part of the beam is welded to the column in the shop and the rest of the beam is bolted with the splice connection in the field. In this study, a replaceable reduced beam section (R-RBS) connection is proposed in order to eliminate welding process and facilitate assembly at the site. In the proposed R-RBS connection, one end is connected by a beam splice connection to the beam and the other end is connected by a bolted end-plate connection to the column. More importantly is that the proposed R-RBS connection allows the replacement of the damaged R-RBS easily right after an earthquake. Pursuant to this goal, experimental and numerical studies have been undertaken to investigate the performance of the R-RBS connection. An experimental study on the RBS connection was used to substantiate the numerical model using ABAQUS, a commercially available finite element software. Additionally, five different finite element models were developed to conduct a parametric study. The results of the analysis were compared in terms of the moment and energy absorption capacities, PEEQ, rupture and tri-axiality indexes. The design process as well as the optimum dimensions of the R-RBS connections are presented. It was also demonstrated that the proposed R-RBS connection satisfies AISC criteria based on the nonlinear finite element analysis results.

후지모리 테루노부 건축의 돌출기둥에 관한 연구 (A Study on the Piercing Column of Terunobu Fujimori Architecture)

  • 김현섭
    • 건축역사연구
    • /
    • 제21권6호
    • /
    • pp.35-44
    • /
    • 2012
  • This paper aimed at investigating into the origin and meaning of the Japanese architect Terunobu Fujimori's 'piercing column', and drew a conclusion as follows. First, the piercing column that made its first appearance in his architect debut work Jinchokan Moriya Historical Museum (1991) was conceived unexpectedly from pencil lines on a sketch that went through over the building's roof. And the tree-like natural treatment of the column's surface was influenced by Takamasa Yoshizaka's description of a Mongolian mud-house. Second, most of piercing columns in his later works have nothing to do with a structural role as in Jinchokan, but were designed for a visual effect and as a symbolic gesture. Again, they allude to a tree in nature through a roughly peeling treatment of the surface. Third, considering his ideas in History of Humankind and Architecture (2005), his column could be related to a universal origin of architecture and a symbol of the sun-god faith, and in particular to independent columns of Japanese Shito shrines, such as 'Onbashira' in Suwa and 'Iwanebashira' in Izumo. That is to say, the Fujimori column is a medium that implies the animistic nature-faith of Japan. Nevertheless, Fujimori's naturalism hints at a disquieting quality through an intentional artificiality and a provocative conflict between structure and finish of a building, which might be one aspect of the modern condition, 'uncanny'.

나무구조를 갖는 네트워크상에서의 제한용량이 있는 입지설정문제에 관한 연구 (A Study for a Capacitated Facility Location Problem on a Tree Structured Network)

  • 조건
    • 대한산업공학회지
    • /
    • 제27권3호
    • /
    • pp.250-259
    • /
    • 2001
  • Given a tree structured network in which each node has its own demand and also stands for a candidate location of a potential facility, such as plant or warehouse, a capacitated facility location problem on the network (CFLPOT) is to decide capacitated facility locations so that the total demand occurred on the network can be satisfied from those facilities with the minimum cost. In this paper, we first introduce a mixed integer programming formulation for CFLPOT with two additional assumptions, the indivisible demand assumption and the contiguity assumption and then show that it can be reformulated as a tree partitioning problem with an exponential number of variables. We then show that it can be solved in O($n^2b$) time by utilizing the limited column generation method developed by Shaw (1993), where n is the total number of nodes in the network and b is the maximum facility capacity. We also develop a depth-first dynamic programming algorithm with a running time of O(nb) for finding the locally maximal reduced cost which plays an important role in the limited column generation method. Finally, we implement our algorithms on a set of randomly generated problems and report the computational results.

  • PDF

Effect of bolted splice within the plastic hinge zone on beam-to-column connection behavior

  • Vatansever, Cuneyt;Kutsal, Kutay
    • Steel and Composite Structures
    • /
    • 제28권6호
    • /
    • pp.767-778
    • /
    • 2018
  • The purpose of this study is to investigate how a fully restrained bolted beam splice affects the connection behavior as a column-tree connection in steel special moment frames under cyclic loading when located within the plastic hinge zone. The impacts of this attachment in protected zone are observed by using nonlinear finite element analyses. This type of splice connection is designed as slip-critical connection and thereby, the possible effects of slippage of the bolts due to a possible loss of pretension in the bolts are also investigated. The 3D models with solid elements that have been developed includes three types of connections which are the connection having fully restrained beam splice located in the plastic hinge location, the connection having fully restrained beam splice located out of the plastic hinge and the connection without beam splice. All connection models satisfied the requirement for the special moment frame connections providing sufficient flexural resistance, determined at column face stated in AISC 341-16. In the connection model having fully restrained beam splice located in the plastic hinge, due to the pretension loss in the bolts, the friction force on the contact surfaces is exceeded, resulting in a relative slip. The reduction in the energy dissipation capacity of the connection is observed to be insignificant. The possibility of the crack occurrence around the bolt holes closest to the column face is found to be higher for the splice connection within the protected zone.

A New Mathematical Formulation for Generating a Multicast Routing Tree

  • Kang, Jang-Ha;Kang, Dong-Han;Park, Sung-Soo
    • Management Science and Financial Engineering
    • /
    • 제12권2호
    • /
    • pp.63-69
    • /
    • 2006
  • To generate a multicast routing tree guaranteeing the quality of service (QoS), we consider the hop constrained Steiner tree problem and propose a new mathematical formulation for it, which contains fewer constraints than a known formulation. An efficient procedure is also proposed to solve the problem. Preliminary tests show that the procedure reduces the computing time significantly.