• Title/Summary/Keyword: column web panel

Search Result 15, Processing Time 0.018 seconds

The Structural Behavior of Strong Axis Connections by Type of Weak Axis Connection - In Case of Loading Gravity Load - (약축 접합부 형식에 따른 강축 접합부의 구조적 거동 - 연직하중이 작용하는 경우 -)

  • Kim, Sang Seup;Lee, Do Hyung;Ham, Jeong Tae
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.2 s.69
    • /
    • pp.275-284
    • /
    • 2004
  • The behavior of the connection for beam-to-column weak axis connection and its details should be identified. Thus, each element is considered a panel zone, and the horizontal stiffener's presence or absence and position in bracket-type welding connection are used as variables to compare the behavior of strong axis connection and weak axis connection. In this study, the strength of connection is calculated by substituting the simple beam-strengthened vertical stiffeners for connection in the presence of horizontal stiffeners. In the absence of horizontal stiffeners, the strength of connection can be calculated using local flange bending strength considering local web yielding strength, web crippling, and web buckling strength. The results of the theoretical analysis and experiments are compared.

Flexural bearing capacity of diaphragm-through joints of concrete-filled square steel tubular columns

  • Rong, Bin;Liu, Rui;Zhang, Ruoyu;Chen, Zhihua;Apostolos, Fafitis
    • Steel and Composite Structures
    • /
    • v.20 no.3
    • /
    • pp.487-500
    • /
    • 2016
  • In order to investigate the flexural bearing capacity of panel zone of diaphragm-through joint between concrete filled square steel tubular column and steel beam, four specimens were tested under static tension loads to study the mechanical properties and bearing capacity of diaphragm-through joints with a failure mode of panel zone. Finite element models of these specimens were developed to simulate the test and compare the predicted failure modes, load-displacement curves and bearing capacities with the experimentally observed. It was found that the tensile load from the steel beam flange is mainly shared by the square steel tube and the diaphragm. The diaphragm plastic zone appears along the cross-section lines enclosed by the square steel tube and the influence of steel beam web on the plastic zone of the steel tube is significant and cannot be neglected. Computational models of yield lines on square steel tube and diaphragm are established based on the distribution pattern of the plastic zone, and an analytical method for the evaluation of the bearing capacity of the joint is proposed. The theoretical results and the experimental data are compared and found in good agreement.

The Ultimate Shear Strength of RCS System Beam-Column Joints Considering the Transverse Beam (직교보를 고려한 RCS구조 보-기둥 접합부의 극한전단강도)

  • An, Jae-Hyeok;Park, Cheon-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.3 s.71
    • /
    • pp.158-163
    • /
    • 2005
  • This paper is focusing on the model to predict the ultimate shear strength on joints of composite system (RCS) with reinforced concrete columns and steel beams considering the transverse beam. It reviews the ratio of experimental shear strength to design strength calculated by existing desist equations which are proposed by Kanno, Wight, Noguchi and the rising of strength by the transverse beams. When the shear strength of joints is estimated, it is necessary to do research work for the stress transfer mechanism considering two concrete strut of inner and outer panel by web of the transverse beam. In order to confirm it requires further experimental and analytical study.

Cyclic Loading Test for Composite Beam-Column Joints using Circular CEFT Columns (콘크리트피복 원형충전강관 기둥-강재보 접합부에 대한 반복하중실험)

  • Lee, Ho Jun;Park, Hong Gun;Choi, In Rak
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.6
    • /
    • pp.411-422
    • /
    • 2017
  • In this study, to investigate the seismic performance of beam-column joints using concrete-encased and -filled circular steel tube(CEFT) columns, two types of tests were performed: (1) column - flange tension test and (2) beam - column joint cyclic load test. In column - flange tension test, test parameters were concrete encasement and connection details: flange width and strengthening rebar. Five specimens were tested to investigate the load-carrying capacity and the failure mode. Test results showed that increase of flange width from 200mm to 350mm result in increase of connection strength and stiffness by 61% and 56%, respectively. Structural performances were further improved with addition of tensile rebars by 35% and 92%, respectively. In cyclic loading test, three exterior beam-column joints were prepared. Test parameters were strengthening details including additional tensile rebars, thickened steel tube, and vertical plate connection. In all joint specimens, flexural yielding of beam was occurred with limited damages in the connection regions. In particular, flexural capacity of beam-column joint was increased due to additional load transfer through tube - beam web connection. Also, connection details such as increase of tube thickness and using vertical plate connection were effective in improving the resistance of panel zone.

Cycllic Seismic Testing of Full-Scale RBS (Reduced Beam Section) Steel Moment Connections (RBS 철골모멘트접합부의 내진거동평가를 위한 반복재하 실물대(實物大) 시험)

  • Lee, Cheol Ho;Jeon, Sang Woo;Kim, Jin Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.4
    • /
    • pp.557-566
    • /
    • 2002
  • This paper summarized the results of a full-scale cyclic seismic testing on four reduced beam section (RBS) steel moment connections. Specifically, these tests addressed a bolted web versus a welded web connection and strong versus medium panel zone (PZ) strength as key test variables. Specimens with medium PZ strength were designed to promote balanced energy dissipation from both PZ and RBS regions, in order to reduce the requirement for expensive doubler plates. Both strong and medium PZ specimens with welded web connection were able to provide sufficient connection rotation capacity required of special moment-resisting frames. On the other hand, specimens with bolted web connection performed poorly due to premature brittle fracture of the beam flange at the weld access hole. Unlike the case of web-welded specimens, specimens with cheaper bolted web connection could not transfer the actual plastic moment of the original (or unreduced) beam section to the column. No fracture occurred within the beam groove welds of any connection in this testing program. If fracture within the beam flange groove weld is avoided by using quality welding procedure as in this study, the fracture issue tends to move into the beam flange base metal at the weld access hole. Supporting analytical study was also conducted in order to understand the observed base metal fracture from the engineering mechanics perspective.