• Title/Summary/Keyword: column sections

Search Result 258, Processing Time 0.022 seconds

Experimental testing of cold-formed built-up members in pure compression

  • Biggs, Kenneth A.;Ramseyer, Chris;Ree, Suhyun;Kang, Thomas H.-K.
    • Steel and Composite Structures
    • /
    • v.18 no.6
    • /
    • pp.1331-1351
    • /
    • 2015
  • Cold-formed built-up members are compression members that are common in multiple areas of steel construction, which include cold-formed steel joints and stud walls. These members are vulnerable to unique buckling behaviors; however, limited experimental research has been done in this area. Give this gap, experimental testing of 71 built-up members was conducted in this study. The variations of the test specimens include multiple lengths, intermediate welds, orientations, and thicknesses. The experimental testing was devised to observe the different buckling modes of the built-up C-channels and the effects of the geometrical properties; to check for applicability of multiple intermediate welding patterns; and to evaluate both the 2001 and 2007 editions of the American Iron and Steel Institute (AISI) Specification for built-up members in pure compression. The AISI-2001 and AISI-2007 were found to give inconsistent results that at times were un-conservative or overly conservative in terms of axial strength. It was also found that orientation of the member has an important impact on the maximum failure load on the member.

Studies on T-Shaped composite columns consist of multi separate concrete-filled square tubular steel sections under eccentric axial load

  • Rong, Bin;You, Guangchao;Zhang, Ruoyu;Feng, Changxi;Liu, Rui
    • Steel and Composite Structures
    • /
    • v.22 no.2
    • /
    • pp.217-234
    • /
    • 2016
  • In order to investigate mechanical properties and load-bearing capacity of T-shaped Concrete-Filled Square Steel Tubular (TCFST) composite columns under eccentric axial load, three T-shaped composite columns were tested under eccentric compression. Experimental results show that failure mode of the columns under eccentric compression was bending buckling of the whole specimen, and mono column performs flexural buckling. Specimens behaved good ductility and load-bearing capacity. Nonlinear finite element analysis was also employed in this investigation. The failure mode, the load-displacement curve and the ultimate bearing capacity of the finite element analysis are in good agreement with the experimental ones. Based on eccentric compression test and parametric finite element analysis, the calculation formula for the equivalent slenderness ratio was proposed and the bearing capacity of TCFST composite columns under eccentric compression was calculated. Results of theoretical calculation, parametric finite element analysis and eccentric compression experiment accord well with each other, which indicates that the theoretical calculation method of the bearing capacity is advisable.

Comparative numerical analysis for cost and embodied carbon optimisation of steel building structures

  • Eleftheriadis, Stathis;Dunant, Cyrille F.;Drewniok, Michal P.;Rogers-Tizard, William;Kyprianou, Constantinos
    • Advances in Computational Design
    • /
    • v.3 no.4
    • /
    • pp.385-404
    • /
    • 2018
  • The study investigated an area of sustainable structural design that is often overlooked in practical engineering applications. Specifically, a novel method to simultaneously optimise the cost and embodied carbon performance of steel building structures was explored in this paper. To achieve this, a parametric design model was developed to analyse code compliant structural configurations based on project specific constraints and rigorous testing of various steel beam sections, floor construction typologies (precast or composite) and column layouts that could not be performed manually by engineering practitioners. Detailed objective functions were embedded in the model to compute the cost and life cycle carbon emissions of the different material types used in the structure. Results from a comparative numerical analysis of a real case study illustrated that the proposed optimisation approach could guide structural engineers towards areas of the solution space with realistic design configurations, enabling them to effectively evaluate trade-offs between cost and carbon performance. This significant contribution implied that the optimisation model could reduce the time required for the design and analysis of multiple structural configurations especially during the early stages of a project. Overall, the paper suggested that the deployment of automated design procedures can enhance the quality as well as the efficiency of the optimisation analysis.

Production of monoclonal antibody(MAb) for lymphocytes of Korean native cattle 1. MAb to T lymphocytes (한우 림프구에 대한 단일항체 생산 1. T 림프구에 대한 단일항체)

  • Song, Hee-jong;Woon, Jae-ho;Kim, Tae-joong;Chai, Hyo-seok;Hur, Boo-hong;Choi, Min-soon
    • Korean Journal of Veterinary Research
    • /
    • v.35 no.4
    • /
    • pp.769-776
    • /
    • 1995
  • This study was undertaken to develop the monoclonal antibody(MAb) for lymphocytes of Korean native cattle by the cell hybridization of myeloma P3/NS-1/ 1-Ag-4-1 and spleen cells from BALB/c mice hyperimmunized with nylon wool column eluted peripheral T lymphocytes of Korean native cattle. The isotype of MAb KCT-14 against T lymphocyte was mouse $IgG_1$. KCT-14 positivity of mononuclear cells(MNC) from peripheral blood lymphocytes, nylon wool nonadherent and adherent-lymphocytes was 41.7%, 58.4% and 22.6%, respectively. And that of mesenteric lymph node-, spleen and thymus-MNC was 43.3%, 40.2% and 33.6%, respectively. Immunoperoxidase staining of frozen tissue sections showed that the MAb positive cells were located in the medulla of the thymus and in the paracortical area and the mantle zone of the germinal center in the lymph nodes. These results indicated that KCT-14 was one of the MAb for investigate of T lymphocyte subpopulations in the Korean native cattle.

  • PDF

Strength and Initial Stiffness of Composite Beams with a Rectangular Web-Opening (직사각형 웨브 개구부를 가진 합성보의 강도와 초기강성도)

  • 김원기;박노웅;이승준
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.3
    • /
    • pp.55-62
    • /
    • 1999
  • For the efficient performance of steel and composite building structures subjected to strong earthquake, one of current research investigates the cyclic behavior of open-web composite beams. Both experimental test and nonlinear FEM analysis demonstrate their behavior so ductile that four T-sections around the corners of rectangular web-opening develop plastic hinges prior to potential brittle failure at the beam end, i.e. at the column face. This research proposes simplified equations for determining strength and initial stiffness of composite beams with a rectangular web-opening, and compares its results with those of experimental test and nonlinear FEM analysis.

  • PDF

Anchored blind bolted composite connection to a concrete filled steel tubular column

  • Agheshlui, Hossein;Goldsworthy, Helen;Gad, Emad;Mirza, Olivia
    • Steel and Composite Structures
    • /
    • v.23 no.1
    • /
    • pp.115-130
    • /
    • 2017
  • A new type of moment-resisting bolted connection was developed for use in composite steel- concrete construction to connect composite open section steel beams to concrete filled steel square tubular columns. The connection was made possible using anchored blind bolts along with two through bolts. It was designed to act compositely with the in-situ reinforced concrete slab to achieve an enhanced stiffness and strength. The developed connection was incorporated in the design of a medium rise (five storey) commercial building which was located in low to medium seismicity regions. The lateral load resisting system for the design building consisted of moment resisting frames in two directions. A major full scale test on a sub-assembly of a perimeter moment-resisting frame of the model building was conducted to study the system behaviour incorporating the proposed connection. The behaviour of the proposed connection and its interaction with the floor slab under cyclic loading representing the earthquake events with return periods of 500 years and 2500 years was investigated. The proposed connection was categorized as semi rigid for unbraced frames based on the classification method presented in Eurocode 3. Furthermore, the proposed connection, composite with the floor slab, successfully provided adequate lateral load resistance for the model building.

Performance of composite frame consisting of steel beams and concrete filled tubes under fire loading

  • Shariati, Mahdi;Grayeli, Mohammad;Shariati, Ali;Naghipour, Morteza
    • Steel and Composite Structures
    • /
    • v.36 no.5
    • /
    • pp.587-602
    • /
    • 2020
  • In recent years, the composite columns have been widely used in the structures. These columns are mainly used to construct the structures with a large span and high floor height. Concrete filled tubes (CFTs) are a type of composite column, which are popular nowadays due to their numerous benefits. The purpose of this study is to investigate such frames at elevated temperatures. The method used in this research is based on section 2.2 of Eurocode 4. First, for the verification purpose, a comparison was made between the experimental results and the numerical model of the concrete filled tube. Then a composite frame was analyzed under fire temperature with different parameters. The results showed that the failure time decreased with increasing the friction of different models. Moreover, investigation of the concrete moisture content revealed that an increase in the concrete moisture content from 3% to 10% led to extended failure time for different models. For instance, in the second frame model, the failure time has increased up to 8%.

Proposed Limit State Design Method for Encased Composite Columns (매립형 합성기둥의 한계상태설계법 제안)

  • Kim, WonKi
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.4 s.33
    • /
    • pp.523-533
    • /
    • 1997
  • Current limit state design method for encased composite columns contains irrational and uncertain design equations in defining section and material properties of composite members. Through investigating previous research used in formulating the design equation, this paper explores the irrationality and uncertainty such as 1) transformation of yield stress and elastic modulus for composite section, 2) an equation influencing buckling strength in terms of area rather than moment of inertia, and 3) selection of larger radius of gyration between steel and concrete sections. Improving the design equations this paper proposes two design methods which can be directly used in practical design.

  • PDF

Neuroanatomical Localization of Cells Containing Gonadotropin Releasing Hormone mRNA in the Brain of Frog, Rana dvbowskii, by in situ Hybridization (In situ hybridization법에 의한 북방산개구리 뇌에서 GnRH mRNA를 함유한 세포의 분포 연구)

  • 최완성;김정우
    • The Korean Journal of Zoology
    • /
    • v.37 no.3
    • /
    • pp.304-310
    • /
    • 1994
  • Using in situ hybridization, we have mapped the anatomical localization of perikarya containing myNA that codes for sonadotropin releasing hormone (GnRH) in the brains of female frogs, R. dybowskii. DNA olisomers, with sequences complementary to the GnRH portion of pro-GnRH myNA sequence, were synthesized and hybridized to paraformaldehvde-fixed, sagittal sections of the whole brain stem. The distribution of the GnRH mRNA containing cell bodies was similar to that described for GnRH peptide by immunohistochemistrv. That is, cells containing GnRH mRNA were observed in the medial septal area, anterior preoptic area, ventromedial hvpothalamus and infundibular regions. However, another cell groups which contains GnRH mRNAs were also detected by in situ hybridization in the bed nucleus of hippocampal commissure, preoptic area, nucleus infundibularis dorsalis, mesencephalic nuclei and intermediolateral cell column of spinal cord areas. These results demonstrate the feasibility of using in situ hybridization as a strategy to study the distribution of GnRH neurons and the detection of GnRH gene expression in the vertebrates.

  • PDF

An Experimental Study on the Behavior of Reinforced Concrete Columns Subjected to Axial Force and Biaxial Bending (2축 휨과 축력을 동시에 받는 철근콘크리트 기둥에 대한 실험적 연구)

  • 김진근;이상순;이수곤;김선영
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.4
    • /
    • pp.55-62
    • /
    • 1999
  • When stress is beyond elastic limit or cracks occur in a reinforced concrete member subjected to axial force and biaxial bending, curvature about each principal axis of uncracked section is influenced by axial force and bending moments about both major and minor principal axes. It is mainly due to the translation and rotation of principal axes of the cross section after cracking. Recently, by considering these effects, a numerical method predicting the behavior of concrete columns subjected to axial force and biaxial bending was proposed. In this study, in order to verify the proposed numerical method and investigate the effects of cracking on the behavior of reinforced concrete columns, a series of tests were carried out for 16 tied reinforced concrete columns with 100×100 mm square and 200×100 mm rectangular sections under various loading conditions. The angle between the direction of eccentricity and the major principal axis of uncracked section were 0, 30, 40° for the square section and 0, 30, 45, 60, 90° for the rectangular section, respectively. A comparison between numerical predictions and test results shows good agreements in ultimate loads, axial force-lateral deflection relations, and lateral deflection trajectories. It is also found, in this limited investigation, that the ACI's moment magnifier method is conservative in both uniaxial and biaxial loading conditions.