• 제목/요약/키워드: column effect

검색결과 2,091건 처리시간 0.025초

고탄수화물 식이 투여 마우스에서 상엽 컬럼분획물의 ${\alpha}$-glycosidase 활성에 미치는 영향 (Effect of Mori Folium Column Fraction on Intestinal ${\alpha}$-glycosidase Activity in Mice Administered with a High Carbohydrate-Containing Diet)

  • 정성현;김미선;조여원
    • 약학회지
    • /
    • 제41권4호
    • /
    • pp.484-491
    • /
    • 1997
  • The effect of prolonged treatment with Mori Folium column fraction(MFCF) on intestinal ${\alpha}$-glycosidase activity has been studied in mice made hyperglycemic and hyperinsulinemic by feeding a high carbohydrate-containing diet. Mice were treated for 10 week with or without MFCF, added to the high carbohydrate-containing diet at 50mg/100g food. While MFCF had no effect on body weight, it prevented the rise in glycemia and insulinemia. Maltase, sucrase and lactase activities were measured in intestinal homogenates of proximal, middle and distal segments of jejunoileum. Following 10 week of MFCF administration, MFCF significantly induced all three enzyme activities especially at middle and distal segments. The mechanisms responsible for these changes and their potential biochemical implications remain to be determined.

  • PDF

Investigation of shear strength models for exterior RC beam-column joint

  • Parate, Kanak;Kumar, Ratnesh
    • Structural Engineering and Mechanics
    • /
    • 제58권3호
    • /
    • pp.475-514
    • /
    • 2016
  • Various models have been proposed by several researchers for predicting the exterior RC beam-column joint shear strength. Most of these models were calibrated and verified with some limited experimental database. From the models it has been identified that the joint shear strength majorly depends on ten governing parameters. In the present paper, detailed investigation of twelve analytical models for predicting shear strength of exterior beam-column joint has been carried out. The study shows the effect of each governing parameter on joint shear strength predicted by various models. It has been observed that the consensus on effect of few of the governing parameters amongst the considered analytical models has not been attained. Moreover, the predicted joint strength by different models varies significantly. Further, the prediction of joint shear strength by these analytical models has also been compared with a set of 200 experimental results from the literature. It has been observed that none of the twelve models are capable of predicting joint shear strength with sufficient accuracy for the complete range of experimental results. The research community has to reconsider the effect of each parameters based on larger set of test results and new improved analytical models should be proposed.

Seismic retrofit of a soft first story structure considering soil effect

  • Michael Adane;Jinkoo Kim
    • Earthquakes and Structures
    • /
    • 제24권5호
    • /
    • pp.345-352
    • /
    • 2023
  • This paper studied the effect of soil-structure interaction (SSI) on the seismic response and retrofit of a reinforced concrete structure with a soft-first story for different soil types. A 5-story structure built on a 30m deep homogeneous soil mass was considered as a case study structure, and steel column jacketing and steel bracing were chosen as seismic retrofit methods. Seismic responses of a fixed-base and a flexible base structure subjected to seven scaled earthquake records were obtained using the software OpenSees to investigate the effect of soil on seismic response and retrofit. The nonlinearBeamColumn elements with the fiber sections were used to simulate the nonlinear behavior of the beams and columns. Soil properties were defined based on shear wave velocity according to categorized site classes defined in ASCE-7. The finite element model of the soil was made using isoparametric four-noded quadrilateral elements and the nonlinear dynamic responses of the combined system of soil and structure were calculated in the OpenSees. The analysis results indicate that the soil-structure interaction plays an important role in the seismic performance and retrofit of a structure with a soft-first story. It was observed that column steel jacketing was effective in the retrofit of the model structure on a fixed base, whereas stronger retrofit measures such as steel bracing were needed when soil-structure interaction was considered.

Leipholz 기둥의 안정성에 미치는 자유단의 탄성구속과 말단질량의 영향 (Influence of Elastic Restraints and Tip Mass at Free End on stability of Leipholz Column)

  • 윤한익;박일주;진종태;김영수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1996년도 춘계학술대회논문집; 부산수산대학교, 10 May 1996
    • /
    • pp.309-315
    • /
    • 1996
  • An analysis is presented on the stability of elastic cantilever column subjected to uniformly distributed follower forces as to the influence of the elastic restraints and a tip mass at the free end. The elastic restraints are formed by both the translational and the rotatory springs. For this purpose, the governing equations and boundary conditions are derived by using Hamilton's principle, and the critical flutter loads and frequencies are obtained from the numerical evaluation of the eigenvalue functions of this elastic system. The added tip mass increases as a whole the critical flutter load in this system, but the presence of its moment of inertia of mass has a destabilizing effect. The existence of the translational and rotatory spring at the free end increases the critical flutter load of the elastic cantilever column. Nevertheless their effects on the critical flutter load are not uniform because of their coupling. The translational spring restraining the end of cantilever column decreases the critical flutter load by coupling with a large value of tip mass, while by coupling with the moment of inertia of tip mass its effect on the critical flutter load is contrary. The rotatory spring restraining the free end of cantilever column increases the critical flutter load by coupling with the tip mass, but decreases it by coupling with the moment of inertia of tip mass.

  • PDF

가변 수주진동장치를 이용한 고효율 파력발전에 관한 연구 (Studies on Variable Liquid-Column Oscillator for High Efficiency Floating Wave Energy Conversion System)

  • 양동순;조병학
    • 한국해양공학회지
    • /
    • 제23권5호
    • /
    • pp.15-24
    • /
    • 2009
  • The results of a simulation study of variable liquid column oscillations in U-tanks with a novel control scheme are presented. The configuration under investigation is analogous to that of the tuned liquid-column damper used to suppress oscillatory motion in large structures like tall buildings and cargo ships. However, by virtue of an adequate controller, the response of amplitude of the U-tanks becomes larger in a desired frequency range. The motion of wave energy conversion system equipped with a variable liquid column oscillator is described by a series of nonlinear differential equations. The equations describe the motion of body under ocean wave excitation, and the motion of liquid with an air-spring effect caused by the compression and expansion of air in vertical liquid columns and air chambers. It is shown that the effect of the air-spring has a vital role to maintain the natural frequency of oscillation in the system to synchronize with the frequency of the ocean wave, thus the system provides the most effective mode for energy extraction from the ocean.

고성능 콘크리트를 충전한 각형강관 기둥의 구조적 거동 특성에 관한 연구 -재하조건별 거동특성- (A study on the Properties for Structural Behavior of High-Performance Concrete Filled Square Steel Tube Columns -The Behavior Properties by Loading Conditions-)

  • 박정민;이승조;김화중
    • 한국강구조학회 논문집
    • /
    • 제10권2호통권35호
    • /
    • pp.177-186
    • /
    • 1998
  • 콘크리트 충전 강관 기둥은 동일 단면의 비충전 강관 기둥에 비해 압축 내력이 우수하며 충전 콘크리트에 의한 강성의 향상, 국부좌굴 보강 효과에 의한 인성의 향상 등과 같은 구조적으로 우수한 점이 많다. 그러나. 강관과 충전 콘크리트의 상호작용 효과, 응력 분담율, 콘크리트의 파괴 양상 등에 대해서는 불분명한 점들이 많다. 본 연구는 일련의 실험을 통하여 고강도 콘크리트 충전 강관 기둥에 대해 재하 조건에 따른 구조적인 거동 특성에 대해 고찰하였다. 특히, 본 연구에서는 재하조건에 따른 강관과 콘크리트의 응력 분담율, 충전 콘크리트의 파괴 양상등에 대해 조사 하였다.

  • PDF

스톤컬럼 공법의 지내력 증진 효과에 대한 연구 (The Study of Improvement Effect of Ground Settlements and Bearing Capacity by Stone Columns)

  • 박상국;이송
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권4호
    • /
    • pp.123-132
    • /
    • 2008
  • 스톤컬럼 공법의 침하량 저감과 지지력 증진 효과를 파악하고자 연약한 준설매립 지반에 쇄석재료와 슬래그 재료를 이용하여 시험시공 후 지하수위계측 및 현장시험을 진행하였다. 현장실험 결과, 지지력 증진 및 침하량 저감 효과가 파악되었으며 상재하중 없이도 지하수위는 저하되는 양상을 보였다. 이는 스톤컬럼 공법이 밀도증가 측면과 더불어 액상화 저항에 우수함을 나타낸다. 일반적인 이론식을 이용하여 원지반 및 복합지반에 대한 침하량과 지지력 산정 결과, 스톤컬럼 공법은 2.7~5.7배의 지지력 증진 효과와 2~3.5배의 침하량 저감 효과가 있는 것으로 판단되었다.

내부 구속 중공 CFT 기둥의 비선형 해석 (Nonlinear Analysis of Internally Confined Hollow CFT Columns)

  • 한택희;원덕희;강영종
    • 한국강구조학회 논문집
    • /
    • 제23권4호
    • /
    • pp.439-454
    • /
    • 2011
  • 내부구속 중공 콘크리트 충전 강관(ICH CFT: Internally Confined Hollow Concrete Filled Tube) 기둥의 비선형 해석모델을 제안하고 기존 연구자의 실험 결과를 이용하여 검증하였다. 제안된 모델은 콘크리트의 구속효과와 재료비선형성을 고려하였다. 검증결과, 제안된 해석 모델은 ICH CFT 기둥의 거동을 예측하는데 합리적이고 신뢰할 수 있는 결과를 보여주었다. 제안된 모델을 이용하여 매개변수 연구를 수행하였으며, 기둥의 거동에 영향을 미치는 주요인자로서 콘크리트의 강도, 중공비, 내부강관의 두께를 매개변수로 선택하였다. 해석결과, 콘크리트 강도와 내부강관의 두께는 기둥의 축강도와 모멘트 저항능력에 큰 영향을 주었으나, 중공비의 변화는 축강도에만 영향을 미치는 결과를 보여주었다.

Influence of slenderness on axially loaded square tubed steel-reinforced concrete columns

  • Yan, Biao;Gan, Dan;Zhou, Xuhong;Zhu, Weiqing
    • Steel and Composite Structures
    • /
    • 제33권3호
    • /
    • pp.375-388
    • /
    • 2019
  • This paper aims to investigate the axial load behavior and stability strength of square tubed steel-reinforced concrete (TSRC) columns. Unlike concrete filled steel tubular (CFST) column, the outer steel tube of a TSRC column is mainly used to provide confinement to the core concrete. Ten specimens were tested under axial compression, and the main test variables included length-to-width ratio (L/B) of the specimens, width-to-thickness ratio (B/t) of the steel tubes, and with or without stud shear connectors on the steel sections. The failure mode, ultimate strength and load-tube stress response of each specimen were summarized and analyzed. The test results indicated that the axial load carried by square tube due to friction and bond of the interface increased with the increase of L/B ratio, while the confinement effect of tube was just the opposite. Parametric studies were performed through ABAQUS based on the test results, and the feasibility of current design codes has also been examined. Finally, a method for calculating the ultimate strength of this composite column was proposed, in which the slenderness effect on the tube confinement was considered.

An approach for partial strengthening of circular RC columns using outer steel tube

  • Hwang, Ju-young;Kwak, Hyo-Gyoung
    • Steel and Composite Structures
    • /
    • 제38권6호
    • /
    • pp.739-749
    • /
    • 2021
  • This paper introduces an improved design equation to evaluate the resisting capacity of circular reinforced concrete (RC) columns partially strengthened with outer steel tube. When RC column members are required to be strengthened according to the change in the loadings considered and/or the deterioration progress in columns, wrapping up RC column with steel circular tube, which takes the form of concrete filled steel tube (CFST), has been popularly considered because of its structural advantage induced from the confinement effect. However, the relatively high construction cost of steel tube is restricting its use to the required region, while deriving the shape of a partial CFST column. To evaluate the resisting capacity of a partial CFST column, numerical analyses need to be performed, and a numerical model proposed in the previous study for the numerical analysis of full CFST columns is used to conduct parametric studies for the introduction of a design equation. The bond-slip effect developed along the interface between the in-filled concrete and the exterior steel tube is taken into consideration and the validity of the numerical model has been established through correlation studies between experimental data and numerical results for partial CFST circular columns. Moreover, parametric studies make it possible to introduce a design equation for determining the optimum length of outer steel tube which produces partial CFST circular columns.