• Title/Summary/Keyword: column effect

Search Result 2,088, Processing Time 0.035 seconds

Effect of Mori Folium Column Fraction on Intestinal ${\alpha}$-glycosidase Activity in Mice Administered with a High Carbohydrate-Containing Diet (고탄수화물 식이 투여 마우스에서 상엽 컬럼분획물의 ${\alpha}$-glycosidase 활성에 미치는 영향)

  • Chung, Sung-Hyun;Kim, Mee-Sun;Choue, Rye-Won
    • YAKHAK HOEJI
    • /
    • v.41 no.4
    • /
    • pp.484-491
    • /
    • 1997
  • The effect of prolonged treatment with Mori Folium column fraction(MFCF) on intestinal ${\alpha}$-glycosidase activity has been studied in mice made hyperglycemic and hyperinsulinemic by feeding a high carbohydrate-containing diet. Mice were treated for 10 week with or without MFCF, added to the high carbohydrate-containing diet at 50mg/100g food. While MFCF had no effect on body weight, it prevented the rise in glycemia and insulinemia. Maltase, sucrase and lactase activities were measured in intestinal homogenates of proximal, middle and distal segments of jejunoileum. Following 10 week of MFCF administration, MFCF significantly induced all three enzyme activities especially at middle and distal segments. The mechanisms responsible for these changes and their potential biochemical implications remain to be determined.

  • PDF

Investigation of shear strength models for exterior RC beam-column joint

  • Parate, Kanak;Kumar, Ratnesh
    • Structural Engineering and Mechanics
    • /
    • v.58 no.3
    • /
    • pp.475-514
    • /
    • 2016
  • Various models have been proposed by several researchers for predicting the exterior RC beam-column joint shear strength. Most of these models were calibrated and verified with some limited experimental database. From the models it has been identified that the joint shear strength majorly depends on ten governing parameters. In the present paper, detailed investigation of twelve analytical models for predicting shear strength of exterior beam-column joint has been carried out. The study shows the effect of each governing parameter on joint shear strength predicted by various models. It has been observed that the consensus on effect of few of the governing parameters amongst the considered analytical models has not been attained. Moreover, the predicted joint strength by different models varies significantly. Further, the prediction of joint shear strength by these analytical models has also been compared with a set of 200 experimental results from the literature. It has been observed that none of the twelve models are capable of predicting joint shear strength with sufficient accuracy for the complete range of experimental results. The research community has to reconsider the effect of each parameters based on larger set of test results and new improved analytical models should be proposed.

Seismic retrofit of a soft first story structure considering soil effect

  • Michael Adane;Jinkoo Kim
    • Earthquakes and Structures
    • /
    • v.24 no.5
    • /
    • pp.345-352
    • /
    • 2023
  • This paper studied the effect of soil-structure interaction (SSI) on the seismic response and retrofit of a reinforced concrete structure with a soft-first story for different soil types. A 5-story structure built on a 30m deep homogeneous soil mass was considered as a case study structure, and steel column jacketing and steel bracing were chosen as seismic retrofit methods. Seismic responses of a fixed-base and a flexible base structure subjected to seven scaled earthquake records were obtained using the software OpenSees to investigate the effect of soil on seismic response and retrofit. The nonlinearBeamColumn elements with the fiber sections were used to simulate the nonlinear behavior of the beams and columns. Soil properties were defined based on shear wave velocity according to categorized site classes defined in ASCE-7. The finite element model of the soil was made using isoparametric four-noded quadrilateral elements and the nonlinear dynamic responses of the combined system of soil and structure were calculated in the OpenSees. The analysis results indicate that the soil-structure interaction plays an important role in the seismic performance and retrofit of a structure with a soft-first story. It was observed that column steel jacketing was effective in the retrofit of the model structure on a fixed base, whereas stronger retrofit measures such as steel bracing were needed when soil-structure interaction was considered.

Influence of Elastic Restraints and Tip Mass at Free End on stability of Leipholz Column (Leipholz 기둥의 안정성에 미치는 자유단의 탄성구속과 말단질량의 영향)

  • 윤한익;박일주;진종태;김영수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.309-315
    • /
    • 1996
  • An analysis is presented on the stability of elastic cantilever column subjected to uniformly distributed follower forces as to the influence of the elastic restraints and a tip mass at the free end. The elastic restraints are formed by both the translational and the rotatory springs. For this purpose, the governing equations and boundary conditions are derived by using Hamilton's principle, and the critical flutter loads and frequencies are obtained from the numerical evaluation of the eigenvalue functions of this elastic system. The added tip mass increases as a whole the critical flutter load in this system, but the presence of its moment of inertia of mass has a destabilizing effect. The existence of the translational and rotatory spring at the free end increases the critical flutter load of the elastic cantilever column. Nevertheless their effects on the critical flutter load are not uniform because of their coupling. The translational spring restraining the end of cantilever column decreases the critical flutter load by coupling with a large value of tip mass, while by coupling with the moment of inertia of tip mass its effect on the critical flutter load is contrary. The rotatory spring restraining the free end of cantilever column increases the critical flutter load by coupling with the tip mass, but decreases it by coupling with the moment of inertia of tip mass.

  • PDF

Studies on Variable Liquid-Column Oscillator for High Efficiency Floating Wave Energy Conversion System (가변 수주진동장치를 이용한 고효율 파력발전에 관한 연구)

  • Yang, Dong-Soon;Cho, Byung-Hak
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.5
    • /
    • pp.15-24
    • /
    • 2009
  • The results of a simulation study of variable liquid column oscillations in U-tanks with a novel control scheme are presented. The configuration under investigation is analogous to that of the tuned liquid-column damper used to suppress oscillatory motion in large structures like tall buildings and cargo ships. However, by virtue of an adequate controller, the response of amplitude of the U-tanks becomes larger in a desired frequency range. The motion of wave energy conversion system equipped with a variable liquid column oscillator is described by a series of nonlinear differential equations. The equations describe the motion of body under ocean wave excitation, and the motion of liquid with an air-spring effect caused by the compression and expansion of air in vertical liquid columns and air chambers. It is shown that the effect of the air-spring has a vital role to maintain the natural frequency of oscillation in the system to synchronize with the frequency of the ocean wave, thus the system provides the most effective mode for energy extraction from the ocean.

A study on the Properties for Structural Behavior of High-Performance Concrete Filled Square Steel Tube Columns -The Behavior Properties by Loading Conditions- (고성능 콘크리트를 충전한 각형강관 기둥의 구조적 거동 특성에 관한 연구 -재하조건별 거동특성-)

  • Park, Jung Min;Lee, Sung Jo;Kim, Wha Jung
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.2 s.35
    • /
    • pp.177-186
    • /
    • 1998
  • The concrete filled steel tubular column have to superior in compressive load carrying capacity, compared with same section typed hollow steel tube column, and have many excellent structural properties, such as stiffness improvement by filled concrete, improvement of ductility by reinforced effect of local buckling, and the like. However, it has not clear the effect of interaction between steel tube and filled concrete, stress portion ratio and fracture mechanism of concrete. This study investigated to structural properties for high strength concrete filled steel tube column by loading conditions through a series of experiments. Especially, this study investigated the properties of structural behaviors for concrete filled steel tube column stress ratio by loading conditions and failure mechanism of filled concrete.

  • PDF

The Study of Improvement Effect of Ground Settlements and Bearing Capacity by Stone Columns (스톤컬럼 공법의 지내력 증진 효과에 대한 연구)

  • Park, Sang-Kook;Lee, Song
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.4
    • /
    • pp.123-132
    • /
    • 2008
  • Aseries of in-situ tests and ground water level measurements with stone and slug materials had been conducted to find out effect of ground settlement reduction and bearing capacity improvement by the Stone Column method. As the result of the tests, it was proved that the Stone Column method is effective for reduction of ground settlement and improvement of bearing capacity. In addition the ground water level went down without overburden load. These results show that the Stone Column method is effective for an increase in density and resistance to liquefaction. The results of estimation of ground settlement and bearing capacity by general theoretical equation, it show that the Stone Column method increases bearing capacity by 2.7~5.7 times and decreases ground settlement by 2~3.5 times.

Nonlinear Analysis of Internally Confined Hollow CFT Columns (내부 구속 중공 CFT 기둥의 비선형 해석)

  • Han, Taek-Hee;Won, Deok-Hee;Kang, Young-Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.4
    • /
    • pp.439-454
    • /
    • 2011
  • A nonlinear analysis model for internally confined hollow concrete-filled tube (ICH CFT) columns was suggested and was verified by the test results obtained by the previous researchers. The suggested model considered the confining effect and nonlinearity of concrete. The verified results showed that the suggested model was reasonable and reliable for predicting the behavior of an ICH CFT column. Additionally, a simple parametric study was carried out. The strength of concrete, the hollow ratio of a column, and the thickness of an inner tube were selected as parameters affecting the behavior of an ICH CFT column. The analysis results showed that the concrete strength and the thickness of the inner tube affect the axial strength and moment capacity of the column while the hollow ratio affects only its axial strength.

Influence of slenderness on axially loaded square tubed steel-reinforced concrete columns

  • Yan, Biao;Gan, Dan;Zhou, Xuhong;Zhu, Weiqing
    • Steel and Composite Structures
    • /
    • v.33 no.3
    • /
    • pp.375-388
    • /
    • 2019
  • This paper aims to investigate the axial load behavior and stability strength of square tubed steel-reinforced concrete (TSRC) columns. Unlike concrete filled steel tubular (CFST) column, the outer steel tube of a TSRC column is mainly used to provide confinement to the core concrete. Ten specimens were tested under axial compression, and the main test variables included length-to-width ratio (L/B) of the specimens, width-to-thickness ratio (B/t) of the steel tubes, and with or without stud shear connectors on the steel sections. The failure mode, ultimate strength and load-tube stress response of each specimen were summarized and analyzed. The test results indicated that the axial load carried by square tube due to friction and bond of the interface increased with the increase of L/B ratio, while the confinement effect of tube was just the opposite. Parametric studies were performed through ABAQUS based on the test results, and the feasibility of current design codes has also been examined. Finally, a method for calculating the ultimate strength of this composite column was proposed, in which the slenderness effect on the tube confinement was considered.

An approach for partial strengthening of circular RC columns using outer steel tube

  • Hwang, Ju-young;Kwak, Hyo-Gyoung
    • Steel and Composite Structures
    • /
    • v.38 no.6
    • /
    • pp.739-749
    • /
    • 2021
  • This paper introduces an improved design equation to evaluate the resisting capacity of circular reinforced concrete (RC) columns partially strengthened with outer steel tube. When RC column members are required to be strengthened according to the change in the loadings considered and/or the deterioration progress in columns, wrapping up RC column with steel circular tube, which takes the form of concrete filled steel tube (CFST), has been popularly considered because of its structural advantage induced from the confinement effect. However, the relatively high construction cost of steel tube is restricting its use to the required region, while deriving the shape of a partial CFST column. To evaluate the resisting capacity of a partial CFST column, numerical analyses need to be performed, and a numerical model proposed in the previous study for the numerical analysis of full CFST columns is used to conduct parametric studies for the introduction of a design equation. The bond-slip effect developed along the interface between the in-filled concrete and the exterior steel tube is taken into consideration and the validity of the numerical model has been established through correlation studies between experimental data and numerical results for partial CFST circular columns. Moreover, parametric studies make it possible to introduce a design equation for determining the optimum length of outer steel tube which produces partial CFST circular columns.