• 제목/요약/키워드: colorimeter

검색결과 220건 처리시간 0.026초

High Spatial Resolution Optical Characterization of LCDs and their Components

  • Boher, P.;Bignon, T.;Leroux, Thierry
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.859-862
    • /
    • 2008
  • We present a new tool to measure precisely the emissive properties of displays at the pixel level with submicrometric spatial resolution. It is useful to check the technological defects and their impact on the emissive properties of the displays. Backlight films and transflective and reflective displays are measured.

  • PDF

P108-Improving the accuracy of colorimeters for display measurements applications

  • Luet, Mathieu;Leroux, Thierry;Curt, Jean-Noel;Horain, David
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.122-126
    • /
    • 2002
  • Measuring color precisely requires the use of a colorimeter whose spectral response is as close as possible to the CIE response. Some techniques such as the NIST 4-color method can improve the precision. but under given conditions, the results can be worse.

  • PDF

부피팽창률법을 이용한 활엽수 열처리 목재의 섬유포화점 측정 (FSP Mesurement of Heat-treated Hardwoods Using Volumetric Swelling Method)

  • 이승진;강석구;강춘원;강호양
    • 한국가구학회지
    • /
    • 제23권2호
    • /
    • pp.163-168
    • /
    • 2012
  • Specimens of seven hardwood species were heat-treated at three temperature levels of 170, 190 and $210^{\circ}C$. Their FSP's were measured by the volumetric swelling method and compared with the control's. Within a species the FSP decreases as the temperature of heat treatment increases. The FSP's of the controls range from 26.1 to 29.6%, while those of the specimens heat-treated at $210^{\circ}C$ from 16.9 to 21.8%. There were no difference of basic density between the heat-treated and control specimens. The color indexes of ash and beech specimens were measured using a colorimeter. It was revealed that the temperature of heat treatment affected on the color more than the treatment time.

  • PDF

열처리에 의한 청변균 변색 소나무 판재의 재색 변화 (Effect of Heat Treatment on the Color Change of Blue-Stained Pinus densiflora Boards)

  • 이원희;임호묵;강호양
    • 한국가구학회지
    • /
    • 제25권4호
    • /
    • pp.319-324
    • /
    • 2014
  • Red pine is a popular species for making a cutting board in Korea, but easily sap stained. Heat treatment could improve its quality by darkening and equalizing the color of sap stained wood. The color change of sap stained red pine boards was investigated by heat treatment at $190^{\circ}C$. It was observed that the color of heat treated boards got darker and it made the color of sap stain vanished. A colorimeter was used to measure color indexes. It was revealed that the values of the lightness ($L^*$) and the yellowness ($b^*$) decreased as heat treatment repeated while the values of the redness ($a^*$) increased. The average of the color difference (${\Delta}E^*$) between the control and 1st heat treated boards was 16.1, which could be expressed as 'Extremely different' while that between the 1st and 2nd heat treated boards was 8.3, which could be expressed as 'Considerably different'. The fact that heat treatment equalized the color of boards was confirmed by a statistical analysis.

  • PDF

Assessment methods for evaluating the whitening effect of cosmetics on human skin

  • Kim, Youn-Soo
    • 대한화장품학회지
    • /
    • 제28권3호
    • /
    • pp.63-90
    • /
    • 2002
  • 멜라닌의 정량은 인체에서 화장품의 미백효과를 평가하기 위한 가장 좋은 방법이지만 인체의 멜라닌 측정을 위한 높은 정확성을 가진 non-invasive방법은 아직 확립되지 않은 실정이다. 피부에서 화장품의 미백효과는 피부색의 밝기로 나타낼 수 있으므로 화장품의 미백효력 평가를 위한 재현성있는 방법으로는 피부색측정을 하는 것이 합리적이다 이에 colorimeter, mexameter와 전문가의 육안평가같은 여러 기기나 분석법이 사용되었다. 이 강연에서는 미백효과에 대한 평가를 위한 다양한 평가방법에 대해 자세히 보고하고 각 방법에 대하여 토의하게 될 것이다 그리고 간단히 임상시험에 대한 결과를 보고하고 마지막으로 melanocyte를 정량하는 새로운 non-invasive방법에 대한 model을 제시하려고 한다.

플라즈마 디스플레이 패널에서 비접촉식 칼라 검사를 위한 칼라 보정 방법 (Color Compensation Method for Non-Contact Color Inspection on Plasma Display Panel)

  • 도현철;김우섭;진성일;태흥식
    • 대한전자공학회논문지SP
    • /
    • 제41권5호
    • /
    • pp.71-75
    • /
    • 2004
  • 본 논문에서는 플라즈마 디스플레이 패널 생산 공정에서 카메라를 이용한 검사장비와 색차계를 이용한 검사장비 사이의 색차를 줄이기 위한 칼라 보정 방법을 제안한다. 칼라 보정 행렬은 두 장비에서 RGB 원색과 기준백색의 색도좌표로 획득한 RGB에서 XYZ 변환 행렬들 사이의 관계를 이용함으로써 구성할 수 있다. 제안한 칼라 보정 방법이 적용된 비접촉식 칼라 검사장비가 다양한 테스트 칼라에 대하여 영역 칼라 CCD 카메라에 의해 획득된 색도좌표를 색차계에 의해 측정된 색도좌표로 만족스럽게 보정됨을 실험결과에서 확인할 수 있다.

Calibration for Color Measurement of Lean Tissue and Fat of the Beef

  • Lee, S.H.;Hwang, H.
    • Agricultural and Biosystems Engineering
    • /
    • 제4권1호
    • /
    • pp.16-21
    • /
    • 2003
  • In the agricultural field, a machine vision system has been widely used to automate most inspection processes especially in quality grading. Though machine vision system was very effective in quantifying geometrical quality factors, it had a deficiency in quantifying color information. This study was conducted to evaluate color of beef using machine vision system. Though measuring color of a beef using machine vision system had an advantage of covering whole lean tissue area at a time compared to a colorimeter, it revealed the problem of sensitivity depending on the system components such as types of camera, lighting conditions, and so on. The effect of color balancing control of a camera was investigated and multi-layer BP neural network based color calibration process was developed. Color calibration network model was trained using reference color patches and showed the high correlation with L*a*b* coordinates of a colorimeter. The proposed calibration process showed the successful adaptability to various measurement environments such as different types of cameras and light sources. Compared results with the proposed calibration process and MLR based calibration were also presented. Color calibration network was also successfully applied to measure the color of the beef. However, it was suggested that reflectance properties of reference materials for calibration and test materials should be considered to achieve more accurate color measurement.

  • PDF

저가형 요분석 시스템의 다중 광 검출 모듈개발 (Development of multi-colorimeter module for low-cost urinalysis strip readers)

  • 예수영;전용욱;정도운;전계록;노정훈
    • 센서학회지
    • /
    • 제17권5호
    • /
    • pp.387-395
    • /
    • 2008
  • An optic module system is developed adopting multiple colorimetry units for the measurement of multi-pad urinalysis dipsticks. Multiple photometry system instead of moving mechanisms has the advantages of system reliability and simplicity as well as economic aspects due to the recent development of economic color light emitting diodes and stable photo sensors. An integration amplifier with programmable integration time, a current source circuit with selectable and stable current settings were connected through analog multiplexers to thirty light emitting diodes for illumination and ten photo transistors for reading each strip pad. All the circuits are controlled by a microprocessor through a simple set of serial communication commands. The detect ability is eighteen times better than the minimum color difference of the test grading which is 0.013 in urobilinogen in the color space defined in this paper.

30% 과산화수소를 함유한 전문가 미백제의 효용성 평가 (A CLINICAL EVALUATION OF EFFICACY OF AN OFFICE BLEACHING GEL CONTAINING 30% HYDROGEN PEROXIDE)

  • 김신영;박재억;김창현;양성은
    • Restorative Dentistry and Endodontics
    • /
    • 제35권1호
    • /
    • pp.40-50
    • /
    • 2010
  • 30% 과산화수소를 함유한 전문가 미백제인 레메화이트(Remewhite, Remedent Inc., Deurle, Belgium)를 시험군 피험자 31명, 시험용 미백제에서 과산화수소를 제외한 동일한 제재를 대조약으로 대조군 피험자 31명에게 1일 3회씩, 2차례에 걸쳐서 시행하였다. 미백의 임상적 효용성은 Colorimeter, Vitapan classical shade guide를 이용하여 전체 색변화량$({\Delta}E^*)$을 측정하였다. 14주 후와 26주 후의 색변화량을 측정하여 군 간 색변화량을 비교하였고, 각 군 내에서의 색변화량도 비교하여 다음과 같은 결론을 얻었다. 1. Colohmeter를 이용한 평가시에 시험군에서 전체 색변화량$({\Delta}E^*)$은 대조군에 비해 통계적으로 유의한 차이를 보였고, Vitapan classical shade guide를 이용한 평가시에는 통계적으로 유의한 차이를 나타내지 않았다(p < 0.05). 2. 시간이 지남에 따라 색 복원 현상이 나타남에도 불구하고 미백 시행 14주 후와 26주 후에도 미백의 효과가 유지된다고 할수 있다. 3. Colohmeter를 이용한 평가시에 Vitapan classical shade guide를 이용한 평가시보다 작은 색변화량을 더 정확하게 측정할 수 있다.

시판차류제품(市販茶類製品)의 Hunter-Lab Tristimulus Colorimeter에 의한 색상(色相) 평가(評價) (Color Evaluation of Commercial Dehydrated Tea-products by Hunter-Lab Tristimulus Colorimeter)

  • 박길동;최진호;성현순
    • 한국식품영양과학회지
    • /
    • 제11권1호
    • /
    • pp.25-30
    • /
    • 1982
  • 시판차류기호식품(市販茶類嗜好食品)의 관능적(官能的) 평가(評價)와 이들 제품(製品)의 품질관리적(品質管理的) 측면(側面)에서 중요시되는 색도(色度)의 지표(指標)를 조사코저 Hunter-lab tristimulus colormeter를 이용(利用)하여 제품(製品)의 입도(粒度), 밀도(密度), 및 탈흡습(脫吸濕)이 색도(色度)에 미치는 영향을 조사하였다. 1. 제품(製品) 사이에는 입도(粒度)의 크기와 색도(色度)에서 특별한 유사성(有意性)이 인정되지 않았으며, 홍삼정분(紅蔘精粉)의 경우 입도(粒度)가 작아질수록 L,a,b 치(値)가 증가하고, X,Y,Z 치(値)에서는 X, Y 치(値)는 증가하는 경향이었으나 Z 치(値)는 일정치 않았다. 2. 시판차류기호식품(市販茶類嗜好食品) L치(値) 범위는 32.8$\sim$48.0이었고 a 치(値)는 3.9$\sim$10.4, b 치(値)는 5.6$\sim$18.0이었으며 대부분의 제품(製品)이 주황색색소계(朱黃色色素系)에 속하는 것으로 나타났다. 3. 제품(製品)의 밀도(密度)는 0.232$\sim$0.898 g/ml의 범위 내에 있었으며 밀도가 클수록 L치(値)가 가하는 경향이었다. 4. 제품별(製品別) a/b치(値)는 생강차를 제외하고 0.61$\sim$0.98의 범위 내에 집중되어 있었으며 총색도(總色度)의 차(差)($\Delta$E) 및 채색도(彩色度)의 차(差)($\Delta$C)가 작은 제품(製品)일수록 색상(色相)의 안정성(安定性)이 인정되었다. 5. 각제품(各製品) 사이에는 흡습(吸濕) 및 탈습(脫濕)에 의한 색상변화(色相變化)는 유의성이 없었다. 6. 광파장(光波長)에 따른 제품별색도(製品別色度)는 생강차, 쌍화차 및 탱이 녹적색계색소(綠赤色系色素)가 가장 높아 녹적색색소계(綠赤色色素系)인 반면 다른 차류제품(茶類製品)은 X,Y,Z 치(値)가 거의 비슷한 경향을 나타냈다.

  • PDF