• Title/Summary/Keyword: color imaging

Search Result 405, Processing Time 0.023 seconds

Image Quality Evaluation and Tolerance Analysis for Camera Lenses with Diffractive Element

  • Lee, Sang-Hyuck;Jeong, Ho-Seop;Jin, Young-Su;Song, Seok-Ho;Park, Woo-Je
    • Journal of the Optical Society of Korea
    • /
    • v.10 no.3
    • /
    • pp.105-111
    • /
    • 2006
  • A novel image quality evaluation method, which is based on combination of the rigorous grating diffraction theory and the ray-optic method, is proposed. It is applied for design optimization and, tolerance analysis of optical imaging systems implementing diffractive optical elements (DOE). The evaluation method can predict the quality and resolution of the image on the image sensor plane through the optical imaging system. Especially, we can simulate the effect of diffraction efficiencies of DOE in the camera lenses module, which is very effective for predicting different color sense and MTF performance. Using this method, we can effectively determine the fabrication tolerances of diffractive and refractive optical elements such as the variations' in profile thickness, and the shoulder of the DOE, as well as conventional parameters such as decenter and tilt in optical-surface alignments. A DOE-based 2M-resolution camera lens module designed by the optimization process based on the proposed image quality evaluation method shows ${\sim}15%$ MTF improvement compared with a design without such an optimization.

IMS High-z Quasar Survey - Faint z~6 Quasar Candidates in IMS Fields

  • Kim, Yongjung;Im, Myungshin;Jeon, Yiseul
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.72.4-73
    • /
    • 2015
  • Over the last decade, more than 50 quasars have been discovered at redshift about 6 when reionization of the universe occurred. However, most of them are luminous quasars (zAB < 21 mag), implying that such a biased quasar sample, which cannot represent the entire population of quasars at z~6, is not enough to understand the properties of quasars in the early universe. Recently, we have been performing the Infrared Medium-deep Survey (IMS), a moderately wide (120 deg2) and deep (JAB ~ 22.5 - 23 mag) near-infrared imaging survey. Combining this with the optical (ugriz) imaging data from the CFHT Legacy Survey (CFHTLS), we have identified more than 10 faint quasar candidates at z~6 in the IMS field by using multiple color selection criteria. From now on, we will perform spectroscopic confirmations of these faint quasar candidates with IMACS on the Magellan Baade Telescope at Las Campanas Observatory and GMOS on the Gemini South Telescope at Gemini Observatory. The confirmed quasars will be used to constrain the faint-end slope of the quasar luminosity function at z~6 and calculate the ratio of quasar ionizing flux to required flux for reionization of the universe. Moreover, these confirmed quasars will be followed up with near-infrared spectroscopy to determine their black hole masses and Eddington ratios to check the rapidness of their growth.

  • PDF

Automatic Estimation of Artemia Hatching Rate Using an Object Discrimination Method

  • Kim, Sung;Cho, Hong-Yeon
    • Ocean and Polar Research
    • /
    • v.35 no.3
    • /
    • pp.239-247
    • /
    • 2013
  • Digital image processing is a process to analyze a large volume of information on digital images. In this study, Artemia hatching rate was measured by automatically classifying and counting cysts and larvae based on color imaging data from cyst hatching experiments using an image processing technique. The Artemia hatching rate estimation consists of a series of processes; a step to convert the scanned image data to a binary image data, a process to detect objects and to extract their shape information in the converted image data, an analysis step to choose an optimal discriminant function, and a step to recognize and classify the objects using the function. The function to classify Artemia cysts and larvae is optimally estimated based on the classification performance using the areas and the plan-form factors of the detected objects. The hatching rate using the image data obtained under the different experimental conditions was estimated in the range of 34-48%. It was shown that the maximum difference is about 19.7% and the average root-mean squared difference is about 10.9% as the difference between the results using an automatic counting (this study) and a manual counting were compared. This technique can be applied to biological specimen analysis using similar imaging information.

A study on assessment of bone mass from aluminum-equivalent image by digital imaging system (디지털 영상 시스템을 이용한 알루미늄 당량화상에 의한 골량 측정에 관한 연구)

  • Kim Jin-Soo;Choi Eui-Hwan;Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.1
    • /
    • pp.87-97
    • /
    • 1997
  • The purpose of this study was to evaluate the method for quantitative assessment of bone mass from aluminum-equivalent value of hydroxyapatite by using digital imaging system consisted of Power Macintosh 7200/120, 15-inch color monitor, and GT-9000 scanner with transparency unit. After aluminum-equivalent image made from correlation between aluminum thickness and grey scale, the accuracy of conversion to mass from aluminum-equivalent value was evaluated. Measured bone mass was compared with converted bone mass from aluminum-equivalent value of hydroxyapatite block by correlation formula between aluminum-equivalent value of hydroxyapatite block and hydroxyapatite mass. The results of this study were as follow; 1. Correlation between aluminum thickness and grey level for obtaining aluminum-equivalent image was high positively associated(r²=0.99). Converted masses from aluminum-equivalent value were very similar to measured masses. There was, statistically, no significant difference(P<0.05) between them 2. Correlation between hydroxyapatite aluminum-equivalent and hydroxyapatite mass was shown to linear relation (r²=0.95). 3. Converted masses from aluminum-equivalent value of 3 dry mandible segments were similar to measured masses. The difference between the exposure directions was not significantly different(P<0.05).

  • PDF

DIT(Digital Imaging Technician) System Design (DIT 시스템 설계)

  • Kang, Jae-Ung;Kim, Young-Jo;Kim, Yong-Jun;Nam, Yun-Dong;Seo, Min-Cheol;Sung, Si-Won;Lee, Sang-Un
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2017.11a
    • /
    • pp.146-148
    • /
    • 2017
  • 기술의 발전에 따라 촬영기기 및 영상장비들의 성능이 비약적으로 향상되고, 본격적인 UHD(Ultra High Definition) 시대가 맞이하여 자연스럽게 소비자들은 더 나은 화질을 요구하고 많은 콘텐츠업체들은 초고화질기술을 적용시킨 작품을 제작하고 있다. 또한, 고품질 콘텐츠에 대한 요구 뿐 만 아니라 데이터 관리(Data Management) 및 색보정(Calibration) 등 이와 관련된 기술의 중요도 증가되고 있다. 따라서 본 논문은 DIT(Digital Imaging Technician) 작업을 차량 내에서 할 수 있도록 특수제작 된 차량을 제작함으로써 현장에서 실시간으로 컬러 그레이딩(Color Grading), 데이터 관리(Data Management) 업무를 수행하여 업무 효율성을 높이고 제작편의성을 증대하고자 한다. 컬러 그레이딩과 데이터 관리라는 요소들이 현재 방송분야보다는 영화와 관련한 분야에서 많이 사용되지만 UHD 시대가 열리는 미래의 방송환경에서는 방송에서도 중요한 요소가 되고 있다.

  • PDF

Autofocus Tracking System Based on Digital Holographic Microscopy and Electrically Tunable Lens

  • Kim, Ju Wan;Lee, Byeong Ha
    • Current Optics and Photonics
    • /
    • v.3 no.1
    • /
    • pp.27-32
    • /
    • 2019
  • We present an autofocus tracking system implemented by the digital refocusing of digital holographic microscopy (DHM) and the tunability of an electrically tunable lens (ETL). Once the defocusing distance of an image is calculated with the DHM, then the focal plane of the imaging system is optically tuned so that it always gives a well-focused image regardless of the object location. The accuracy of the focus is evaluated by calculating the contrast of refocused images. The DHM is performed in an off-axis holographic configuration, and the ETL performs the focal plane tuning. With this proposed system, we can easily track down the object drifting along the depth direction without using any physical scanning. In addition, the proposed system can simultaneously obtain the digital hologram and the optical image by using the RGB channels of a color camera. In our experiment, the digital hologram is obtained by using the red channel and the optical image is obtained by the blue channel of the same camera at the same time. This technique is expected to find a good application in the long-term imaging of various floating cells.

A New Instrument for Measuring the Optical Properties of Wide-field-of-view Virtual-reality Devices

  • Ahn, Hee Kyung;Lim, Hyun Kyoon;Kang, Pilseong
    • Current Optics and Photonics
    • /
    • v.6 no.4
    • /
    • pp.392-399
    • /
    • 2022
  • Light-measuring devices (LMDs) are frequently used to measure luminance and color coordinates of displays. However, it is very difficult to use a conventional LMD for measuring the optical properties of virtual-reality (VR) devices with a wide field of view (FOV), because of their confined spaces where the entrance pupil of a LMD is located. In this paper, a new LMD that can measure the optical properties of wide-FOV VR devices, without physical conflict with the goggles of the VR device, is proposed. The LMD is designed to fully satisfy the requirements of IEC 63145-20-10, and a pivot-point correction method for the LMD is applied to improve its accuracy. To show the feasibility of the developed LMD and the correction method, seven VR devices with wide FOV are measured with it. From the results, all of them are successfully measured without any physical conflict, and a comparison to their nominal values shows that the FOVs have been properly measured.

Searching for Dwarf Galaxies in Deep Images of NGC 1291 obtained with KMTNet

  • Byun, Woowon;Kim, Minjin;Sheen, Yun-Kyeong;Park, Hong Soo;Ho, Luis C.;Lee, Joon Hyeop;Jeong, Hyunjin;Kim, Sang Chul;Park, Byeong-Gon;Seon, Kwang-Il;Ko, Jongwan
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.38.3-38.3
    • /
    • 2019
  • We present newly discovered dwarf galaxy candidates in deep wide-field images of NGC 1291 obtained with KMTNet. We identify 15 dwarf galaxy candidates by visual inspection within the virial radius of NGC 1291. Using imaging simulations, we demonstrate that our imaging data is complete up to 26 mag arcsec-2 or -10 abs.mag with > 70% of the completeness rate. We also apply automated detection method to find the dwarfs. However, the completeness and the reliability are relatively low compared to the visual inspection. We find that structural and photometric properties of dwarf candidates such as effective radius, central surface brightness, Sérsic index, and absolute magnitude appear to be consistent with those of known dwarf galaxies in nearby groups and clusters, except for color. NGC 1291, residing in a relatively isolated environment, tends to accompany bluer dwarf galaxies (≃0.58) than those in denser environment. It shows that the quenching of dwarfs is susceptible to the environment.

  • PDF

Three-dimensional assessment of condylar surface changes and remodeling after orthognathic surgery

  • Lee, Jung-Hye;Lee, Woo-Jin;Shin, Jae-Myung;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.46 no.1
    • /
    • pp.25-31
    • /
    • 2016
  • Purpose: This study was performed to evaluate condylar surface changes and remodeling after orthognathic surgery using three-dimensional computed tomography (3D CT) imaging, including comparisons between the right and left sides and between the sexes. Materials and Methods: Forty patients (20 males and 20 females) who underwent multi-detector CT examinations before and after surgery were selected. Three-dimensional images comprising thousands of points on the condylar surface were obtained before and after surgery. For the quantitative assessment of condylar surface changes, point-to-point (preoperative-to-postoperative) distances were calculated using 3D processing software. These point-to-point distances were converted to a color map. In order to evaluate the types of condylar remodeling, the condylar head was divided into six areas (anteromedial, anteromiddle, anterolateral, posteromedial, posteromiddle, and posterolateral areas) and each area was classified into three types of condylar remodeling (bone formation, no change, and bone resorption) based on the color map. Additionally, comparative analyses were performed between the right and left sides and according to sex. Results: The mean of the average point-to-point distances on condylar surface was $0.11{\pm}0.03mm$. Bone resorption occurred more frequently than other types of condylar remodeling, especially in the lateral areas. However, bone formation in the anteromedial area was particularly prominent. No significant difference was found between the right and left condyles, but condylar surface changes in males were significantly larger than in females. Conclusion: This study revealed that condylar remodeling exhibited a tendency towards bone resorption, especially in the lateral areas. Condylar surface changes occurred, but were small.

Color Correction Method for High Dynamic Range Image Using Dynamic Cone Response Function (동적 원추 세포 응답을 이용한 높은 동적 폭을 갖는 영상 색상 보정 방법)

  • Choi, Ho-Hyoung;Yun, Byoung-Ju
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.9
    • /
    • pp.104-112
    • /
    • 2012
  • Recently, the HDR imaging technique that mimics human eye is incorporated with LCD/LED display devices to deal with mismatch between the real world scene and the displayed image. However, HDR image has a veiling glare limit as well as a scale of the local contrast problem. In order to overcome these problems, several color correction methods, CSR(center/surround Retinex), MSR (Multi-Scale Retinex), tone-mapping method, iCAM06 and so on, are proposed. However, these methods have a dominated color throughout the entire resulting image after performing color correction. Accordingly, this paper presents a new color correction method using dynamic cone response function. The proposed color correction method consists of tone-mapping and dynamic cone response. The tone-mapping is obtained by using a linear interpolation between chromatic and achromatic. Thereafter, the resulting image is processed through the dynamic cone response function, which estimates the dynamic responses of human visual system as well as deals with mismatch between the real scene image and the rendered image. The experiment results show that the proposed method yields better performance of color correction over the conventional methods.