• 제목/요약/키워드: collection efficiency

검색결과 958건 처리시간 0.026초

Improvement of a High-volume Aerosol Particle Sampler for Collecting Submicron Particles through the Combined Use of a Cyclone with a Smoothened Inner Wall and a Circular Cone Attachment

  • Okuda, Tomoaki;Isobe, Ryoma
    • Asian Journal of Atmospheric Environment
    • /
    • 제11권2호
    • /
    • pp.131-137
    • /
    • 2017
  • A cyclone is an effective tool to facilitate the collection of aerosol particles without using filters, and in cell exposure studies is able to collect a sufficient amount of aerosol particles to evaluate their adverse health effect. In this study, we examined two different methods to improve the aerosol particle collection efficiency of a cyclone. The individual and combined effects of reducing the surface roughness of the inner wall of the cyclone and of using a circular cone attachment were tested. The collection efficiency of particles of diameter $0.2{\mu}m$ was improved by approximately 10% when using a cyclone with a smoothened inner wall (average roughness $Ra=0.08{\mu}m$) compared with the original cyclone ($Ra=5.1{\mu}m$). A circular cone attachment placed between the bottom section of the cyclone and the top section of a collection bottle, resulted in improved collection of smaller particles without the attachment. The 50% cutoff diameter of the modified cyclone (combined use of smoothened inner wall and attachment) was $0.23{\mu}m$ compared to $0.28{\mu}m$ in the original model. The combined use of these two techniques resulted in improved collection efficiency of aerosol particles.

슬릿 임팩터의 입자 포집 효율에 관한 연구 (An Experimental Study on Particle Collection Efficiency of the Slit Impactor)

  • 황창덕;허재영;김상수
    • 대한기계학회논문집
    • /
    • 제13권4호
    • /
    • pp.689-696
    • /
    • 1989
  • 본 실험에서는 종래와는 달리 먼저 입출구 부분에서 입자분포 측정장치를 이용하여 실험함으로써 여러 가지 입자크기에 대하여 동시에 효율을 구할 수 있는 장치를 구성하고 앞에서 열거한 여러 가지 실험인자중 레이놀즈수와 S/W를 변화시키면 서 일단 슬릿 임팩터(one-stage slit impactor)의 효율을 .root.Stk에 따라 구하여 일단 임팩터 뿐만 아니라 다단 임팩터(multistage impactor)에 대한 설계기초자료를 마련하 고자 한다.

충진층식 세정집진기의 집진특성 실험 (An Experiment on the Particle Collection Characteristics in a Packed Wet Scrubber)

  • 유경훈;노희환;최은수;김종균
    • 설비공학논문집
    • /
    • 제15권4호
    • /
    • pp.305-311
    • /
    • 2003
  • DOP aerosol particles with geometric mean diameter of 0.5-3.0 ${\mu}{\textrm}{m}$, geometric standard deviation of 1.1-1.3 and total number concentration of 1,500-8,000 Particles/㎤ were used to determine collection efficiencies of a packed wet scrubber with respect to particle size. The tested operating variables included air velocity and water injection rate. It was shown from the experimental results that the collection efficiencies increased with increasing water injection rate and decreasing air velocity. Meanwhile, as for the particle size variation, all of the collection efficiency curves increased rapidly between 0.57-1.41${\mu}{\textrm}{m}$ for the range of water injection rate above 30 L/min. It was also seen that the collection efficiency of a packed wet scrubber is mainly governed by the mechanism of inertial impaction.

Hot Cell 내의 고방사능 분진 제거를 위한 사이클론 적용 실험 (Application of Cyclone to Removal of Hot Particulate in Hot Cell)

  • 김계남;이성열;원휘준;정종헌;오원진
    • 방사성폐기물학회지
    • /
    • 제3권1호
    • /
    • pp.67-75
    • /
    • 2005
  • 원자력시설 핫셀 (Hot Cell)내에서 핵종실험 시 발생하는 고방사능 분진(Hot Particulate)의 크기는 0.5300 ${\mu}m$이고 주 핵종은 UO$_2$였다. 핫셀 내의 고방사능 분진을 제거하기 위해 사이클론과 Bag/HEPA필터로 구성된 장치를 고안하였고, 이 장치의 사이클론에 의해 고방사능 분진을 최대로 포집할 수 있는 실험조건을 제시했다. 모의입자의 크기가 클수록 입자의 포집효율은 높았다. 모의 입자의 크기가 5${\mu}m$ 이상일 때, 입자의 포집효율은 $80\%$보다 높았다. 모의 입자의 크기가 1.0 ${\mu}m$ 보다 작을 때, 포집효율은 $70\%$ 보다 작았다. 모의 입자의 유입속도가 12 m/sec보다 클 때, 포집효율은 $70\%$보다 높았다. 그러나 유입속도가 17 m/sec 보다 클 때 포집효율의 증가율은 크지 않았다. 모의입자의 포집효율은 Vortex Finder의 길이가 7.2 cm이하일 때, 길이의 증가와 함께 높아졌지만 7.2 cm 이상일 때는 낮아지기 시작했다. 그러므로 Vortex Finder의 길이가 7.2 cm 일 때, 최대포집효율을 나타냈다. 사이클론 밑에 보조콘 부착 시 모든 속도 범위에서 약 평균 $2\%$ 정도 포집효율이 증가하므로 보조콘 부착효과가 크지 않았다.

  • PDF

2단 평행판 정전식 집진기에서의 입자하전 및 포집 (Particle Charging and Collection in Two-Stage, Parallel-Plate Electrostatic Precipitators)

  • 오명도;유경훈;이준식
    • 대한기계학회논문집
    • /
    • 제18권2호
    • /
    • pp.432-445
    • /
    • 1994
  • From a theoretical analysis point of view, the 2-stage precipitator is decomposed into two units: charging cell and collecting cell. Collection efficiency predictions of the two-stage parallel-plate electrostatic precipitator have been performed theoretically incorporating with the charging and the collecting cells. Particle trajectorise passing the charging cell have been modeled as a simple one. Particle charge distribution at the outlet of the charging cell is calculated through integration of the present unipolar combined charging rate along the entire particle trajectory, and average charge of particles at the outlet of the charging cell is obtained from the particle charge distribution. As for the collecting cell, the diminution of particle concentration along the longitudinal direction of the collecting cell is investigated considering the conventional Deutsch's theory and the laminar theory. One should note that the collection efficiency formula derived is based on monodisperse aerosols. It has been confirmed through the analysis that predictions of particle charge by applying White's unipolar diffusion charging theory overpredict actual cases in the continuum regime, while predictions by Fuch's unipolar diffusion charging theory indicate the reasonable result in the same regime. Theoretical predictions of collection efficiency are also compared with the available experimental results. Comparisons show that the experimental results are consistently located in the collection efficiency region bounded by the two limits, the Deutsch and the laminar collection efficiencies. Finally design parameters of the 2-stage electrostatic precipitator have been investigated systematically through the one-variable-at-a-time method in terms of collection efficiency. Applied voltages on the corona wire of the charging cell and the plate of the collecting cell, and the average air velocity have been selected as the design parameters.

1단 전기 집진기에서 2차 유동이 집진 효율에 미치는 영향 (Effect of Secondary Flows on the Particle Collection Efficiency in Single Stage Electrostatic Precipitator)

  • 이재복;배귀남;황정호
    • 대한기계학회논문집B
    • /
    • 제24권2호
    • /
    • pp.251-259
    • /
    • 2000
  • The ionic wind formed in a nonuniform electric field has been recognized to have a significant effect on particle collection in an electrostatic precipitator(ESP). Under normal operating conditions the effect of ionic wind is not pronounced. However, as the flow velocity becomes smaller, the ionic wind becomes pronounced and induces secondary flow, which has a significant influence on the flow field and the particle collecting efficiency. In this paper, experiments for investigating the effect of secondary flow on collection efficiencies were carried out by changing the flow velocities in 0.2-0.7m/s and the applied voltages in 9-11kV/cm. The particle size distributions and concentrations are measured by DMA and CNC. To analyze the experimental results, numerical analysis of electric filed in ESP was carried out. It shows that particle collection is influenced by two independent dimensionless numbers, $Re_{ehd}\;and\;Re_{flow}$ not by $N_{ehd}$ alone. When $Re_{flow}$, decreases for constant $Re_{ehd}$, the secondary flow prohibits the particle collection. But when $Re_{ehd}$ increases for constant $Re_{flow}$, it enhances the particle collection by driving the particles into the collection region.

이동 전극형 전기집진기의 집진특성에 관한 연구 - II. 펄스 하전 파형 및 분진농도의 영향 - (A Study on the Collection Characteristics of a Moving Electrode Electrostatic Precipitator - II. Effect of Wave Form of Pulse Energization and Dust Concentration -)

  • 김용진;하병길;정상현;홍원석;유주식
    • 설비공학논문집
    • /
    • 제16권10호
    • /
    • pp.908-913
    • /
    • 2004
  • This study investigates the effect of the wave form of pulse energization and dust concentration on the collection characteristics of a moving electrode electrostatic precipitator (MEEP). Under the same specific corona power, the collection efficiency of the MEEP for the lower dust concentration ($2g/m^3$) becomes higher than that for the higher concentration ($10g/m^3$). Both the collection efficiency and specific corona power increase with increasing pulse period for the same value of applied voltage. The collection efficiency of MEEP is higher than that of the conventional fixed plate electrode electrostatic precipitator.

전기집진장치에서 가스의 물리적인 특성에 따른 포집구역내의 입자포집율 연구 (A Study on the Mass Collection Efficiency in Collector Step of Electrostatic Precipitator by Physical Gas Characterization)

  • 하상안;임경택;신남철
    • 한국환경과학회지
    • /
    • 제7권1호
    • /
    • pp.36-40
    • /
    • 1998
  • This study was carried out to investigate the collection Efficiency of mass in collector step at the different of physical gas characterization. This work has focused on the dependence of the collection efficiency of mass in the collector zone of a two-stage set up field with gas temperature T and the dew point tmeperature. To identify the dependence of the mass collection efficiency on the Bounded plate of the collector zone MP.k by the spectre electric resistance of dust $p_e$. and the relative humidify ${\varphi}$, 20 at- tempts have been made with three different gas temperature ($50{\circ}C, 80{\circ}C, 110{\circ}C$) at different dew point. At the specific electric resistance of dust $p_e$=$10^6{\Omega}m$ which relative humidity corresponds to $\phi$ > 15%, a easy rise of the sounded plate secluded dust mass share was measured atwain. As the result of the higher cohesion imprisonment power due to the adsorbtion of particle, the rinse of the relative humidity developed on the particle surface. Therefore, the collection efficiency of mass was not predominant the high temperature T in the collector zone, neither was the pecific ellectric resistance of dust dependent.

  • PDF

방전극 형상 및 여과재에 따른 정전 여과집진장치특성에 관한 연구 (Investigation of Characteristics of Electrostatic Bag Filter with Discharge Electrode Shapes and Filter Properties)

  • 김정일;여석준
    • 한국대기환경학회지
    • /
    • 제14권3호
    • /
    • pp.237-250
    • /
    • 1998
  • In this study, the characteristics of electrostatic bag filter to overcome the main problems such as the high pressure drop and low collection efficiency for submicron particles are investigated with the experimental parameters. Especially, the experiment is carried out focusing on collection efficiency and pressure drop change mechanism as a function of discharge electrode shapes and filter properties, including the applied voltages, filtration velocities and particle concentrations, etc . Results show that the collection efficiency is improved over 30% for the fine particle below 1 pm and pressure drop reduction ratio (PDRR) increases in the following order 4 mm screwy > 4 mm square > 4mm round discharge electrodes . For the filter properties, Nomex is more effective than PE under the influence of electrostatic force. Applying 30 kV for a screwy discharge electrode, higher overall collection efficiency is maintained in spite of the increment of filtration velocity over four times (8 m/min) in comparison with that of 2 m/min and PDRR are highly shown over 80o1o with various filtration velocities, 5, 8, 11 m/min.

  • PDF

석탄연소 보일러용 분진의 전기집진특성 (Electrostatic Precipitation Characteristics of Coal Combustion Boiler)

  • 이태식;분차석;김경석;남창우;이규철
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권6호
    • /
    • pp.475-482
    • /
    • 1999
  • The electrostatic precipitation characteristics of two kinds of fly ashes, one derived from a fluidized bed combustor(FBC), the other from a pulverized coal(PC) fired furnace, have been studied on a pilot plant. Experiments have been carried out to enhance the collection efficiency while changing the operating conditions for two kinds of coal ashes, respectively. It has been shown that collection efficiency is affected by many factors such as shape of the ashes, dust contents, humidity, and temperature, etc. Experimantal results showed that collection efficiency of the FBC ashes was higher than that of the PC fly ash in spite of the small size of the FBC ashes. The experimetal results have been applied to the collection efficiency equations to show that the modified Deutsch equation was well agreed with experiment results if modification parameter k was set to 0.6 for the fluidized bed fly ashes and to 0.43 for the pulverized coal fly ashes.

  • PDF