• Title/Summary/Keyword: collecting efficiency

Search Result 374, Processing Time 0.028 seconds

The Study on the Efficacy of Herbal Plant Extracts by the Part and Solvent Extraction (약용식물의 부위별 및 추출용매에 따른 효능 연구)

  • Kim, Hyung-Dong;Kim, Sang-Jin
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.33 no.2
    • /
    • pp.127-135
    • /
    • 2007
  • This study was to evaluate the efficiency of different solvent systems to extract active ingredients from different parts of medicinal plants used as oriental medicinal herb in the cosmetic industry. We tested efficacies related to the antioxidative effects and UV absorption of herbal extracts as complex of active ingredients, not each single ingredient. When extracting medicinal plant which is used effective medicine, we should consider the collecting conditions like collecting time, place, part and extracting conditions like solvent, temperature, time, and etc. Among them, extraction solvent and collecting part are very important factors for the efficacy. As increased interest in medicinal plants, more intensive studies on collecting conditions and extracting processes were needed for the developments in the herbal ingredient industry. We evaluated the efficiency of different solvent systems to extract active ingredients from different parts of plants (Terminalia chebula, Syzygium aromaticum, Paeonia lactiflora, Morus alba, Scutellaria baicalensis) widely used as medicine and food. As results, we found that proper condition can make better data and decrease the required quantity.

Rig Tester Development for the Performance Validation of a Piston Oil Cooling Gallery (피스톤 오일 냉각 유로의 성능 검증을 위한 리그 시험기 개발)

  • Chun, Sang-Myung;Lee, Jeong-Keun;Joo, Dae-Heon;Ryu, Kwan-Ho;Ha, Dae-Hong
    • Tribology and Lubricants
    • /
    • v.25 no.6
    • /
    • pp.387-398
    • /
    • 2009
  • The operation condition of recently designed pistons for high power and high speed diesel engine become more severe due to the increment of combustion pressure and temperature. So, in order to overcome high temperature, the application of the mono-metal cast aluminum alloy piston featuring an enclosed cast-in open cooling gallery has increased. In this research, it is developed a PCJ (piston cooling jet) rig tester, described the test procedure and validated the performance of sample piston cooling gallery design. Then the test rig will be used for developing the design technology of piston cooling gallery. The test rig is composed with oil reservoir and pumping system, oil jet system, piston fixing and moving system, collecting oil measuring system, and data measuring and recording system. It will be measured collecting efficiencies under conditions of a few piston positions, oil jet pressures and oil viscosities for a piston cooling gallery. Furthermore, the PCJ rig tester will be used for the optimum design of the oil cooling gallery which being applied to increase the cooling efficiency of pistons in diesel engines satisfying the EURO V emission regulation and the more.

Convergent Study on the Hydro-Gas Reforming Cyclo-Incinerator (물 가스 개질 고속선회 소각로에 관한 융합연구)

  • Han, Doo-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.10
    • /
    • pp.231-236
    • /
    • 2020
  • A water reforming reaction high-speed turning incinerator test facility was prepared. The reforming reaction chamber and the combustion chamber were directly connected. The incinerator and dust collecting device were integrated and made into a double bulkhead type air cooling structure. The blower is built into the dust collector to improve spatial efficiency. An axial flow type multi-stage dust collector was applied by collecting dust by using a plurality of dust collecting bins attached to the side of the dust collecting part. As a result of measuring dioxin among the exhausted gases, results below the standard value were obtained. As a result of measuring exhaust gas and heavy metals, results were obtained below the environmental standard.

An advanced study of multi-stage type hydrocyclone dust collector for fish egg collecting using Visualization (가시화기법을 이용한 다단형 하이드로 사이클론 어란 (魚卵) 집진장치의 개선에 관한 연구)

  • CHOI, Eunhee;PYEON, Yongbeom;LEE, Seung-heon;LEE, Kyounghoon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.53 no.4
    • /
    • pp.404-412
    • /
    • 2017
  • A centrifugal cyclone dust collecting apparatus includes a hydro cyclone dust collecting apparatus for separating solid or liquid using liquid or suspension as a medium. In this study, the formation mechanism and improvement of air core and inner air layer were confirmed through Particle Image Velocimetry. These results showed that the modified experimental model was designed in the conventional method suitable for the separation of juvenile fish and eggs. The inlet speed of the multi-stage hydrocyclone dust collector, which can increase the inlet velocity and minimize floatage in the turbulence chamber, was increased from 0.15 to 0.30 m/s. As a result, the air core was stably formed, the inner air layer was increased with increasing speed. In addition, the dust collecting efficiency of egg and juvenile fish was 97.8% on average, It can infer that this system confirmed the ability to efficiently collect particles of $40{\mu}m$ or more.

Evaluation of Particle Collection Efficiency in a Wet Electrostatic Precipitator Using an Electrosprayed Discharge Electrode (정전분무 방전극을 이용한 습식 전기집진장치의 미세먼지 집진효율 평가)

  • Kim, Hong-Jik;Kim, Jong-Hyeon;Kim, Jong-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.6
    • /
    • pp.530-537
    • /
    • 2015
  • The wet electrostatic precipitator (wet ESP) is an effective control device which removes submicron particles reentrained in a collection plate and water soluble gas. However, its collection efficiency decreases, as its operation is subject to water-induced distortion of the collection electrode. In order to make up for the limitation, we modified the wet ESP system by installing electrosprayed discharge electrodes. The modified wet ESP system can wash both the collection plate and discharge electrode. As a result, we were able to fabricate a compact wet ESP with a small specific collecting area ($0.18m^2(m^3/min)$) that can accomplish a high collection efficiency of fine particles (97.1%). In addition, the device obtained a relatively low specific corona power of approximately $10W/(m^3/min)$.

A Customized Cleaning Agent for the Maintenance of Electric Fume Collector Used for the Purification of Effluent Gas from the Textile Industry (섬유산업 배기가스 정화용 Electric Fume Collector 설비의 유지보수를 위한 맞춤형 세정제)

  • Kim, Hotae;Yoo, Hwang-Yooll;Jeon, Koung Min;Song, Doori;Kim, Jin-Bae
    • Applied Chemistry for Engineering
    • /
    • v.29 no.2
    • /
    • pp.229-236
    • /
    • 2018
  • A customized cleaning agent was investigated for improving the performance decreased by the pollution of collecting plates in an electric fume collector (EFC) which was developed and applied for the purification of effluent gas including oil mist from the textile industry. The pollutants on the surface of collecting plates were blackened by the condensation of oil mist for a long time and difficult to remove by general cleaning agents. The composition of an optimized cleaning agent consisted of alkali, alcohol, glycol and non-ionic surfactant sources was determined by considering the pollutant properties and effect on the damage of the basic metal of collecting plate and so on. The developed cleaning agent solution diluted by 9.1% was applied to the field test, and also the pollutants strongly adhered on collecting plate surfaces were successfully removed by a simple spraying method. The effluent gas purification efficiency of EFC increased significantly by cleaning of collecting plates.

Analyzing the Efficiency of Regional Medical Resource Uses for Foreign Patient Care (외국인 환자 진료를 위한 지역별 의료자원 이용의 효율성 분석)

  • Cha, Sun-Mi;Lee, Kwang-Soo
    • The Korean Journal of Health Service Management
    • /
    • v.7 no.3
    • /
    • pp.225-235
    • /
    • 2013
  • This study purposed to analyze the productivity of regional medical capacity in attracting medical tourist between 2009 and 2011. Data envelopment analysis (DEA) and Malmquist productivity index (MPI) were applied to test the productivity and changes in study periods. The DEA model included a number of doctors, nurses, and beds as input factors, and a number of inpatient and outpatient, and hospital income as output factors. The result of the study were as follow. Jeju had efficiency value of 1 for three years. Seoul, Busan, Daegu, Daejeon, Ulsan, Gyeonggi, Gangwon, Jeonnam, Gyeongbuk, and Gyeongnam showed an increasing trend of efficiency value over three years. Seoul had the efficiency value, 1, in 2011. But, Incheon, Gwangju showed decreasing efficiency score during the study period. MPI showed overall productivity decrease during the period. Further studies will be needed by collecting more time-series data.

High-Efficiency Polymer-Titanium Oxide Hybrid Solar Cells

  • Lee, Kwang-Hee
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.186-186
    • /
    • 2006
  • We report a new architecture for high efficiency polymer solar cells introducing a new concept of 'optical spacer' with new material. By implementing a novel solution-based titanium oxide ($TiO_{x}$) layer between the active layer and the electron collecting Al electrode, we invented a way to increase ${\sim}50\;%$ in power conversion efficiency compared to conventional polymer solar cells. Now the new devices exhibit ${\sim}6\;%$ power conversion efficiency, which is the highest value reported to date for a polymer based photovoltaic cell. The $TiO_{x}$ layer increases the efficiency by modifying the spatial distribution of the light intensity inside the device, thereby creating more photogenerated charge carriers in the bulk heterojunction layer.

  • PDF

A Study on the Development of Thin ESP for High Efficient Air-conditioner (공조용 박형 전기집진장치 개발에 관한 연구)

  • Hong, Yeong-Gi;Sin, Su-Yeon;Jo, Jeong-Su;Park, Jeong-Hu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.1
    • /
    • pp.34-38
    • /
    • 1999
  • In order to develop a thin type ESP(Electrostatic Precipitator) for high efficient air-conditioner with low concentration of ozone generation, collecting electrode spacing should be narrower than that from Deutsch formula and minimizes discharge current in ionizer. In this paper, the effect of applied voltage on the precipitation efficiency and ozone concentration of scroll type ESP was studied. As a result, precipitation efficiency(one pass) was improved by about 30[%] from increment of collector voltage(3.5[㎸]). Precipitation efficiency was increased with increasing ionizer voltage. And after some point, the efficiency was saturated. At the point, voltage and ionizer current was 5.2[㎸] and 95$[\muA]$ per meter respectively. At these applied voltage conditions, ozone concentration was saturated about 0.01[ppm] after 3 hours in 23$[m^3]$ closed room test.

  • PDF

Flow visualization of PM preprocessing system using the small scale gascyclone precipitator (소형 가스사이클론 집진장치를 이용한 PM 전처리 시스템의 유동 가시화)

  • YANG, Yongsu;LEE, Kyounghoon;JO, Hyeonjeong
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.52 no.3
    • /
    • pp.263-270
    • /
    • 2016
  • This study is aimed to design the mechanical gascyclone precipitator with an outstanding collection efficiency as one of ways to reduce exhaust gas of small-scale vessels. It estimated fine particles generated from diesel engines which has become one of the biggest environmental issues currently. Specifically, it quantitatively analyzed the flowing process from the cyclone gas exit; a duct via part to the collecting part of Cylindrical lower using DPIV (Digital Particle Image Velocimetry). Since the gas inlet height part became wider the previous theoretical dimensions, internal fluid characteristics of cyclone where the speed of internal swirl had been slow were investigated by temporary streamline of fine particles at $14-20{\mu}m$. The results showed that collecting efficiency was three times higher than the conical type utilized previously. In addition, this study supplemented imprecision problems from the previous theoretical equation and CFD interpretation with an experimental method. It also provided a basic data to design the cyclone precipitator by size of diesel engines for vessels.