Development of a dose estimation code for BNCT with GPU accelerated Monte Carlo and collapsed cone Convolution method

  • Lee, Chang-Min;Lee Hee-Seock
    • Nuclear Engineering and Technology
    • /
    • 제54권5호
    • /
    • pp.1769-1780
    • /
    • 2022
  • A new method of dose calculation algorithm, called GPU-accelerated Monte Carlo and collapsed cone Convolution (GMCC) was developed to improve the calculation speed of BNCT treatment planning system. The GPU-accelerated Monte Carlo routine in GMCC is used to simulate the neutron transport over whole energy range and the Collapsed Cone Convolution method is to calculate the gamma dose. Other dose components due to alpha particles and protons, are calculated using the calculated neutron flux and reaction data. The mathematical principle and the algorithm architecture are introduced. The accuracy and performance of the GMCC were verified by comparing with the FLUKA results. A water phantom and a head CT voxel model were simulated. The neutron flux and the absorbed dose obtained by the GMCC were consistent well with the FLUKA results. In the case of head CT voxel model, the mean absolute percentage error for the neutron flux and the absorbed dose were 3.98% and 3.91%, respectively. The calculation speed of the absorbed dose by the GMCC was 56 times faster than the FLUKA code. It was verified that the GMCC could be a good candidate tool instead of the Monte Carlo method in the BNCT dose calculations.

방사선치료계획시스템의 Collapsed Cone Convolution 선량계산 알고리듬을 이용한 빔 모델링의 정확성 평가 (Evaluation of Beam Modeling Using Collapsed Cone Convolution Algorithm for Dose Calculation in Radiation Treatment Planning System)

  • 정주영;조웅;김민주;이정우;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제23권3호
    • /
    • pp.188-198
    • /
    • 2012
  • 본 연구의 목적은 국내 개발된 치료계획장치(Treatment Planning System, TPS)인 CorePLAN$^{TM}$에서의 빔 모델링을 기반으로 하는 Collapsed Cone Convolution (CCC) 선량 계산 알고리듬의 정확성을 평가하는 것이다. 여러 셋업 조건에 따라 빔 모델을 TPS에 생성하였고, 6 MV와 15 MV 광자 에너지에 대하여 $50{\times}50{\times}50cm^3$의 물 팬톰 내에서 CCC 알고리듬을 사용하여 선량 계산을 하였다. 대상 조사면은 $4{\times}4cm^2$, $6{\times}6cm^2$, $10{\times}10cm^2$, $20{\times}20cm^2$, $30{\times}30cm^2$$40{\times}40cm^2$을 대상으로 하였고, 각각에 대하여 열린 조사면과 쐐기 조사면으로 구분하였다. 생성된 빔 모델들은 측정된 데이터와 계산된 데이터의 심부선량백분율(Percent depth dose, PDD)과 선량프로파일(lateral profile)을 비교하여 모든 깊이에서도 잘 맞는지 평가하였다. 측정된 방사선량과 CorePLAN$^{TM}$에서 CCC 알고리듬을 이용하여 계산된 방사선량은 PDD에 있어 build-up 영역을 제외하고 열린 조사면은 최대 2%, 쐐기 조사면는 최대 3% 이내로 일치하였다. 선량프로파일은 조사면 내 영역에서는 1%, 반음영 영역에서는 4% 이내로 일치함을 확인하였다. 모든 조사면에서 반음영을 제외한 $10{\times}10cm^2$에서 최대 $40{\times}40cm^2$까지의 선량프로파일에 대하여 측정된 방사선량과 계산된 방사선량이 3% 이내로 일치하였다. 반면에, 열린 조사면에 비하여 쐐기 조사면에서 선량 차이가 뿔(horn) 영역의 가장자리에서 4%까지 높게 나타났다. 본 연구 결과에서 보여주는 선량 차이는 일부 영역을 제외하고 국제 기준에 적합한 결과값을 보였다. 선량 차이가 크게 발생하는 영역은 임상적으로 중요성이 크지 않은 표면 영역임을 감안할 때, 임상에서의 활용이 가능하리라 기대된다.

Feasibility Study of Mobius3D for Patient-Specific Quality Assurance in the Volumetric Modulated Arc Therapy

  • Lee, Chang Yeol;Kim, Woo Chul;Kim, Hun Jeong;Lee, Jeongshim;Huh, Hyun Do
    • 한국의학물리학회지:의학물리
    • /
    • 제30권4호
    • /
    • pp.120-127
    • /
    • 2019
  • Purpose: This study was designed to evaluate the dosimetric performance of Mobius3D by comparison with an aSi-based electronic portal imaging device (EPID) and Octavius 4D, which are conventionally used for patient-specific prescription dose verification. Methods: The study was conducted using nine patients who were treated by volumetric modulated arc therapy. To evaluate the feasibility of Mobius3D for prescription dose verification, we compared the QA results of Mobius3D to an aSi-based EPID and the Octavius 4D dose verification methods. The first was the comparison of the Mobius3D verification phantom dose, and the second was to gamma index analysis. Results: The percentage differences between the calculated point dose and measurements from a PTW31010 ion chamber were 1.6%±1.3%, 2.0%±0.8%, and 1.2%±1.2%, using collapsed cone convolution, an analytical anisotropic algorithm, and the AcurosXB algorithm respectively. The average difference was found to be 1.6%±0.3%. Additionally, in the case of using the PTW31014 ion chamber, the corresponding results were 2.0%±1.4%, 2.4%±2.1%, and 1.6%±2.5%, showing an average agreement within 2.0%±0.3%. Considering all the criteria, the Mobius3D result showed that the percentage dose difference from the EPID was within 0.46%±0.34% on average, and the percentage dose difference from Octavius 4D was within 3.14%±2.85% on average. Conclusions: We conclude that Mobius3D can be used interchangeably with phantom-based dosimetry systems, which are commonly used as patient-specific prescription dose verification tools, especially under the conditions of 3%/3 mm and 95% pass rate.

불균질부 방사선치료 시 계획 선량의 정확성 평가 (Evaluation of Planning Dose Accuracy in Case of Radiation Treatment on Inhomogeneous Organ Structure)

  • 김찬용;이제희;곽용국;하민용
    • 대한방사선치료학회지
    • /
    • 제25권2호
    • /
    • pp.137-143
    • /
    • 2013
  • 목 적: 불균질부를 포함하고 있는 치료부위의 치료계획 시 불균질 경계면에서의 TPS상 선량분포와 phantom을 이용하여 측정된 실제 선량분포를 비교하여 그 차이를 알아보고자 한다. 대상 및 방법: 4 cm 두께의 solid water phantom 사이에 폐와 유사한 밀도를 가진 8 cm 두께의 cork (density: 0.23 $g/cm^2$)를 위치시켜 phantom을 제작하여 CT 영상을 획득하였으며, 본원에서 사용하고 있는 Pinnacle 치료계획 시스템의 Collapsed-cone(CC) convolution 선량계산 알고리즘을 이용하여 6/15 MV 광자선으로 치료 계획된 선량분포와 실제 phantom에 EBT2 필름을 삽입해 측정한 선량을 비교 평가하였다. 또한 실제 폐암 환자와 유사한 치료계획을 비교하기 위해 Phantom 내부에 치료하고자 하는 종양부위(target volume)로 가정한 파라핀($3{\times}3{\times}3$ cm)을 Location "A" (일반조직과 떨어져있는 가상의 종양: 섬모델)와 Location "B" (일반조직과 붙어있는 가상의 종양: 반도모델)에 삽입하여 CT scan 후 치료계획을 시행하였다. 선량계획과 동일한 조건으로 Phantom을 set-up 후 Phantom의 paraffin target volume 경계면 A (Ant방향), B (Rt방향), C (Post 방향) point에 필름을 삽입하고 방사선을 조사하여 측정된 선량을 TPS선량과 비교평가 하였다. 결 과: 불균질 phantom을 이용한 계획선량과 측정선량과의 차이는 solid water와 cork 경계면을 제외한 부분에서 선량차이가 크지 않았지만 밀도가 급격히 변화하는 첫 번째 구간과 두 번째 구간에서 -5.4%~-12.6%의 선량감소를 보였다. 또한 paraffin target을 삽입한 실험에서는 Location "A"의 경우 실제 측정선량이 A, B, C point에서 각각 -2.5~-4.7%, -2.3~-2.8%, -4.5~-8.8%의 낮은 선량을 나타냈으며, Location "B"의 경우에도 A, B, C point에서 각각 0.08~5.27%, -3.17~-4.74%, -7.86~-11.56%의 선량 차이를 나타내었다. 결 론: 이번 연구의 결과 불균질부 내에서의 치료계획 시스템의 계획된 선량과 실제 측정된 선량에 오차의 가능성이 확인되었다. 급속도로 발전하고 있는 방사선 치료기술과 그만큼 정밀함을 요하는 치료계획 시 이러한 가능성에 대해 인지하고 선량검증에 대한 여러 방법들을 연구하고 개발하는 것이 치료의 발전과 필수적으로 동반되어야 할 것이며 본원에서도 이번 연구를 통해 치료계획 시 발생할 수 있는 변수에 대해서 더 주의 깊게 판단하고 적용할 수 있을 것으로 사료된다.