• Title/Summary/Keyword: cold weather condition

Search Result 91, Processing Time 0.023 seconds

A Comparative Experimental Study on Thermal Performance of Box-typed Double Skin and Curtain Wall in Cooling Period (박스형 이중외피와 커튼월의 냉방기 열적성능에 관한 비교실험 연구)

  • Park, Chang-Young;Lee, Keon-Ho;Yoon, Yong-Sang;Choi, Chang-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.2
    • /
    • pp.111-119
    • /
    • 2007
  • The annual mean temperature of South Korea has risen by $1.3^{\circ}C$ for last 100 years by urbanization and industrialization. Especially, the frequency of unusual hot weather in summer increases for a long time and the frequency of unusual cold weather in winter clearly decreases. In recently, The considerable portion of curtain wall system is appled to building skin in domestic. As related to this, the Korea Institute of Construction Technology devised the box typed double skin facade(It is occasionally called as FDFS : Functional Double Facade System) as an alternative that reflects the distinctive local climate and saves cooling energy. Two mock-ups($49m^*4.9m$) applied to single skin(curtain wall) and double skin each were monitored under the outdoor condition. Therefore, the characteristics of natural ventilation and cooling energy consumption of each window had been analyzed in real time. The results of this study are summarized as follow, Analysis of the experiment on an air conditioner: the indoor temperature of the chamber with FDFS is lower than that of the chamber with single skin facades by $3{\sim}6$ degrees(C). A temperature variation of about $1{\sim}2$ degrees between the 0.2m and 1.7m height of the mock-up occurs in FDFS, while that of about maximum 7 degrees occurs in single skin facade at noon with abundant intensity of solar accident. Also, 67 percent of energy consumption for air conditioning has been saved.

Analysis of Heating Load of a Naturally Ventilated Broiler House using BES Simulation (BES 기법을 이용한 자연환기식 육계사의 난방에너지 분석)

  • Hong, S.W.;Lee, I.B.;Hong, H.K.;Seo, I.H.;Hwang, H.S.;Bitog, J.P.;Yoo, J.I.;Kwon, K.S.;Ha, T.H.;Kim, K.S.
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.50 no.1
    • /
    • pp.39-47
    • /
    • 2008
  • Most of the broiler houses in Korea have experienced problems on controlling the environmental conditions such as suitability, stability and uniformity of rearing condition inside the broiler house. It is very critical which if not properly controlled, would cause serious stress on the chickens. It is therefore urgent to develop optimum designs of naturally ventilated broiler house which is appropriate to the four seasons of Korea. Field experiment for this matter is very difficult to conduct due to the unpredictable and uncontrollable weather condition. In this study, the heating load of a naturally ventilated broiler house was calculated using TRANSYS 15 BES program while internal climate and thermal condition were computed using Fluent 6.2. The computed resulted of the conventional ventilation system (A) and upgraded ventilation system (B) (Seo et al, 2007) were compared with each other for cold season. The results of the Building Energy Simulation(BES) indicated that the system B, the upgraded ventilation system made 8% lower total heating load and 47% lower at only the broiler zone compared to the conventional broiler house. Considering the entire broiler house, the existence of middle ceiling made the heating energy 11% lower required than without middle ceiling. Accordingly, the system B with middle ceiling was found to save heating energy by 20% in average. This study showed that the BES program can be a very powerful to effectively compute the energy loads of agricultural building while the energy load is very close related to ventilation efficiency.

Long-term pattern changes of sea surface temperature during summer and winter due to climate change in the Korea Waters

  • In-Seong Han;Joon-Soo Lee;Hae-Kun Jung
    • Fisheries and Aquatic Sciences
    • /
    • v.26 no.11
    • /
    • pp.639-648
    • /
    • 2023
  • The sea surface temperature (SST) and ocean heat content in the Korea Waters are gradually increased. Especially the increasing trend of annual mean SST in the Korea Water is higher about 2.6 times than the global mean during past 55 years (1968-2022). Before 2010s, the increasing trend of SST was led by winter season in the Korea Waters. However, this pattern was clearly changed after 2010s. The increasing trend of SST during summer is higher about 3.9 times than during winter after 2010s. We examine the long-term variations of several ocean and climate factors to understand the reasons for the long-term pattern changes of SST between summer and winter in recent. Tsushima warm current was significantly strengthened in summer compare to winter during past 33 years (1986-2018). The long-term patterns of Siberian High and East Asian Winter Monsoon were definitely changed before and after early- or mid-2000s. The intensities of those two climate factors was changed to the increasing trend or weakened decreasing trend from the distinctive decreasing trend. In addition, the extreme weather condition like the heatwave days and cold spell days in the Korea significantly increased since mid- or late-2000s. From these results, we can consider that the occurrences of frequent and intensified marine heatwaves during summer and marine cold spells during winter in the Korea Waters might be related with the long-term pattern change of SST, which should be caused by the long-term change of climate factors and advection heat, in a few decade.

Period of the Strength Correction of the Concrete with the Temperature Level Based on Meteorological Data (기상자료를 이용한 콘크리트의 단계별 기온보정강도 적응기간 산정)

  • Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.2
    • /
    • pp.107-112
    • /
    • 2008
  • According to Korean Architectural Standard Specification (KASS) , at the design stage of the specified concrete strength, strength correction with each temperature level should be considered to secure required strength at 28 days even in low temperature condition, In this paper, the period for the strength correction at the stage of mixture design of the concrete using ordinary Portland cement(OPC) specified in KASS was determined with each region of south Korea based on the meteorological data of KMA(Korea meteorological administration) by applying KASS-5 regulation. In case of 28 days of strength control age, the period for strength correction with 6MPa was calculated to $50{\sim}60$ days and, with 3 MPa. to around 80 days. The period for the strength correction was shown to be decreased with the rise of altitude. The period to consider the delay of the strength development due to low temperature including the period of cold weather concrete was nearly 7 months around 1 year. References for determining the strength correction factors with each region of south Korea was provided in this paper. Further investigation of strength correction of the concrete containing blended cement is to studied.

A Study on Evaporator Front Air Velocity of Small Refrigeration Ceiling Dehumidifier (소형 냉각식 천정형 제습기의 증발기 전면 풍속에 관한 연구)

  • KIM, Jin-Cheol;JEONG, Kyeong-Tae;KUM, Jong-Soo;KIM, Dong-Gyu
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.4
    • /
    • pp.1107-1113
    • /
    • 2016
  • In the environment with high humidity causes negative influence on human's body and living condition. As the weather gets more humid, people's interest of dehumidifier for household arising recently. The cooling dehumidifier dehumidify the air by using refrigeration cycle technology which means it removes vapor by let the humid air pass through the cold surface. The amount dehumidified of refrigerating method dehumidifier affected by multiple factors. However, the refrigerating method dehumidifier for household in the market controls pass wind velocity technology to adjust the amount of dehumidification. As the pass wind velocity increases, the amount of wind increases hence the heat exchange amount increases accordingly. However, the amount of dehumidification decreases because the temperature difference between the air and vaporization decreases. Therefore, simply by increasing air velocity does not increase the amount of dehumidification. This research examined the effect of air velocity out of all variety of factors to the amount of dehumidification for refrigerating method dehumidifier.

A Study on the Strength Properties and the Temperature Hysteresis of Winter Concrete according to the difference of Curing Method in Mock-up Test (실물대시험에서의 양생방법 차이에 따른 한중콘크리트의 온도이력 및 강도특성에 관한 연구)

  • Won, Cheol;Han, Cheon-Goo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.4
    • /
    • pp.87-94
    • /
    • 2003
  • This study is to investigate the temperature hysteresis and development of compressive strength due to the curing conditions and to evaluate the optimum curing condition of test specimens showing the same development of strength to that of real structures in cold weather. The results of temperature curve with curing conditions in mock-up tests showed the trend of decrease plain concrete with insulation form, plain concrete with heating, concrete with accelerator for freeze protection, and control concrete in turn. The strength development of plain concrete of inside and outside of shelter showed the very slow strength gains due to early freezing, but that of concrete with accelerator for freeze protection showed the gradual increase of strength with time. From this, it is clear that accelerator for freeze protection has the effects of refusing the freezing temperature and accelerating the hardening under low temperature. Strength test results of small specimens embedded in members and located in insulation boxes at the site are similar to that of cores drilled from the members at the same ages, thus it is clear that these curing methods are effective for evaluating in-place concrete strength

Diffusion Simulation Using Envi-Met. in Urban Planetary Boundary Layer (Envi-Met.을 이용한 도심 대기경계층 내 확산장 변화 수치 모의)

  • Choi, Hyun-Jeong
    • Journal of Climate Change Research
    • /
    • v.7 no.3
    • /
    • pp.357-371
    • /
    • 2016
  • Buildings in the city acts as a cause of distorted wind direction, wind speed, causing the stagnation of the air flow. In the recent trend of climate change can not but consider the temperature rise of the urbanization. This study was aimed to analyze the thermal comfort of planetary boundary layer in different artificial constructions areas which has a direct impact on urban climate, and estimating the warming phenomena. Envi-met model was used to consider the urban structure associated with urban growth in order to precisely determine the impact of the building on the city weather condition. The analyzed values of thermal comfort index were temperature, wind speed, horizontal and vertical turbulent diffusivity. In particular, analysis of the PPD(Predicted Percentage of Dissatisfied) represents the human thermal comfort. In this study, by adjusting the arrangement and proportion of the top floor building in the urban it was found that the inflow of the fresh air and cooling can be derived low PPD. Vertical heat flux amount of the city caused by climate change was a factor to form a high potential temperature in the city and the accumulation of cold air does not appear near the surface. Based on this, to make the city effectively respond to climate change may require a long-term restructuring of urban spatial structure and density management.

A Study on the Theory of Latent Qi Wenbing -Focusing on Its Background and Logicality- (역대 복기온병설(伏氣溫病說)에 대한 고찰 -학설의 배경과 논리성을 중심으로-)

  • Yun, Ki-ryoung
    • Journal of Korean Medical classics
    • /
    • v.34 no.2
    • /
    • pp.23-44
    • /
    • 2021
  • Objectives : The theory of Latent Qi Wenbing and its counter-arguments were examined in terms of each argument's theoretical background and logicality. Methods :Arguments for and against the theory of Latent Qi Wenbing in medical texts were examined closely. Results & Conclusions : Each doctor's theory on Latent Qi Wenbing was examined in the following four aspects. First, to what kind of pathogenic qi was the patient exposed during Winter? Second, how did the pathogenic qi affect the body in the time of exposure? Third, how did the latent qi change over the Spring and Summer within the body? Fourth, what kind of weather generates the disease during Spring and Summer? Each argument had different opinions on each aspect. The main argument made against the theory of Latent Qi Wenbing is that it is impossible for the pathogenic qi that initially damaged the body to stay latent until it generates disease after some time. The theory of Latent Qi Wenbing could be assumed to have been created based on situations in which such explanation was adept. Factors that contribute to this theory could be explained through the condition of the healthy qi, state of cultivation during the past season, and constitutional factors.

Thermal Stresses of Roller Compacted Concrete Dam Considering Construction Sequence and Seasonal Temperature (시공단계 및 계절별 온도영향을 고려한 롤러다짐콘크리트댐의 온도응력 해석)

  • Cha, Soo-Won;Jang, Bong-Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.6A
    • /
    • pp.881-891
    • /
    • 2008
  • The purpose of the present study is to investigate the influence of seasonal temperature variation on the thermal stresses in roller compacted concrete dam(RCD) structures. Using the finite element code, DIANA performs 2-D transient temperature and resultant stress analysis for RCD. Time variability of the mesh geometry is considered in order to simulate successive phases of the structure's construction. The main analysis variables are construction sequence, concrete temperature and ambient temperature. The results show principal tensile stress of hot-weathering concrete is higher than that of cold-weathering concrete. In some case the index of thermal cracking excesses 1.0, RCD also needs thermal management on placing temperature according to weather condition.

Characteristic of Temperature History of Slab concrete by the Change of Insulation Curing Material and Difference of Heated cable Power Capacity. (단열양생재 변화 및 열선 전력용량 차이에 따른 슬래브 콘크리트의 온도이력 특성)

  • Jung, Eun-Bong;Ahn, Sang-Ku;Jung, Sang-Hyun;Koh, Kyung-Taek;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.334-336
    • /
    • 2013
  • In this study, the temperature history was evaluated for the improved bubble sheets combining hot wires and PE films, which were developed under the extreme environmental condition of -10℃ and applied on the top surface of slab to prevent initial damage by freezing. Results can be summarized as follows. If improved bubble sheets combining hot wires with different capacity on double and quadruple bubble sheets are used, the temperature history for all materials decreased to 2~3℃ below zero but all test materials except Type 1 secured the accumulative temperature of 45° D·D at 7 days of material age, required for the prevention of initial freezing damage. This indicates the bubble sheets can prevent the initial damage by freezing.

  • PDF