• Title/Summary/Keyword: cold temperature dry

Search Result 166, Processing Time 0.031 seconds

Overwintering Capacity Affected by Seeding Time and Method of Chinese Milk Vetch, Astragalus sinicus L., in Upland Field

  • Lee Ji Hyun;Kang Byeung Hoa;Shim Sang In
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.50 no.2
    • /
    • pp.67-72
    • /
    • 2005
  • Overwintering capacity, closely related to winter hardiness, of Chinese milk vetch planted with different sowing times and sowing practices was investigated to improve the incorporation into cropping system in Korea. The tolerance to low temperature was evaluated with $LT_50$ using leaf disc leaching method. Dry weight of CMV was reduced remarkably with delayed planting from Sep. 5 to Oct. 20. The differences in tolerance to freezing temperature were not conspicuous among CMV genotypes, however, the differences between genotype (collections at different regions) were due to the plant architecture, mainly to the leaf angle. The crouching genotype collected at central region of Korean peninsula, which showed excellent freezing tolerant, has planophile leaves. The feature of internal constituents of CMV genotypes did not show any noticeable differences with respect to the freezing tolerance which evaluated by leaf disc leaching experiment. To overcome the poor overwintering capacity, tolerant genotype should be developed by selection with considering the plant architecture. The reduction of CMV growth during overwintering period was ameliorated with furrow-sowing under late-sown condition, therefore, when the CMV is inevitably sown late after recommended time, the seeds should be sown on furrow to overcome the cold stress.

Vitrification of Simulated Combustible Dry Active Wastes in a Pilot Facility

  • Yang, Kyung-Hwa;Park, Seung-Chul;Lee, Kyung-Ho;Hwang, Tae-Won;Maeng, Sung-Jun;Shin, Sang-Woon
    • Nuclear Engineering and Technology
    • /
    • v.33 no.4
    • /
    • pp.355-364
    • /
    • 2001
  • In order to evaluate and finally optimize the vitrification condition for combustible dry active waste (DAW), dust and gas generation characteristics were investigated for PE, cellulose, and mixed waste Tests were conducted by varying the operation variables such as melter configuration, excess oxygen amount, and waste feeding rate. Results showed that dust generation characteristics were affected by the operation parameters and the melter's configuration is the dominant one. For all tested DAWs, dust generation was reduced by increasing the waste feeding rate and the excessive oxygen amount in the melter. Among waste types, dust amount was decreased by the order of mixed wastes, PE, and cellulose. Other parameters such as temperature variation and operation time have also affected the dust generation. The optimum condition for the DAW vitrification was determined as the melter's configuration equipped for minimizing the waste dispersion with 20 kg/h of waste feeding rate and 100% of excessive oxygen supply. CO gas concentration in the off-gas was immediately influenced by the combustion state in the melter, but showed similar trend as the dust generation. For the NOx production during the vitrification process, thermal NOx, which is generated from the Post Combustion Chamber (PCC), rather than fuel NOx was assumed to be dominant. The gas cleaning of efficiencies of the PCC, wet scrubber, and Selective Catalytic Reduction system (SCR) were found to be high enough to keep the concentration of pollutants (CO, NOx, SOx, HCI) in the stack below their relevant emission limits.

  • PDF

Germination and Growth Performance of A Native Threatened Tree Species Quercus gomeziana A. Camus in Nursery Stage: Case of Bangladesh

  • Nandi, Rajasree;Dey, Soma;Hossain, Mohammed Kamal
    • Journal of Forest and Environmental Science
    • /
    • v.36 no.1
    • /
    • pp.1-6
    • /
    • 2020
  • This study was conducted to investigate the effect of different pre-sowing treatments of seeds on germination and growth performance of native threatened tree species Quercus gomeziana A. Camus at the nursery of Chittagong University, Bangladesh. Furthermore, seedling growth attributes under different doses of fertilizer (urea) was also experimented to find the best dose of fertilizer on this tree species at the nursery stage for better field level growth. Seeds were placed to six pre-sowing treatments e.g. control (PT0), treated with sand paper rubbing (PT1), nicking (PT2), seeds immersed in cold water for 48 hours (PT3), seeds immersed in cold water for 7 days (PT4) and seeds sown at propagator house with increased temperature (PT5). It was found from the study that germination was started earlier (at 31 days) in treatments sand paper rubbing (PT1) and nicking (PT2). The highest germination percentage (93%) was in PT1 followed by 86% in seeds immersed in cold water for 7 days (PT4) and 80% in PT0 (control). Germination percentage was observed least (63%) in PT2 even though germination started earlier. For fertilizer dose experiment to seedlings at the nursery level, treatment FT1: 100 kg/ha (0.33679 g urea/pot/seedling) comparing with other treatments FT0: 0 kg/ha (Control), FT2: 200 kg/ha (0.67358 g urea/pot/seedling), FT3: 300 kg/ha (1.01037 g urea/pot/seedling) showed better performance in case of collar diameter (6.74 mm), number of leaves, shoot dry weight (19.74), total dry weight (28.16 g), total fresh weight (67.96 g), volume index (3904.82), sturdiness (127.69). Finally, it can be concluded that Quercus gomeziana seedlings revealed better performances under the treatment FT1 in growth and biomass production. Findings of this study will be helpful to take decision on organic fertilizer dose application to seedlings of Q. gomeziana for large scale plantation and conservation of this species.

Winter Indoor Thermal Environment Status of Nursery Rooms in Workplace Daycare Centers in Jeju Island (제주지역 직장어린이집 보육실의 겨울철 실내온열환경 실태)

  • Kim, Bong-Ae;Ko, Youn-Suk
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.33 no.12
    • /
    • pp.81-90
    • /
    • 2017
  • This study was conducted to investigate the thermal environment status of nursery rooms in workplace daycare centers in Jeju and propose measures to improve their indoor physical thermal environment. For this purpose, measurements were performed in the winter indoor physical environment of 51 nursery rooms in 11 workplace daycare centers and a psychological evaluation survey on the thermal environment of nursery rooms was conducted for 70 nursery teachers. The investigation was carried out over 11 days in January 2017. The results are as follow. The average indoor temperature of the nursery rooms was $21.3^{\circ}C$($18.7-23.8^{\circ}C$) and the indoor temperatures of 47 nursery rooms (92.9%) were higher than the environmental hygiene management standard for domestic school facilities ($18-20^{\circ}C$). The average relative humidity was 33.9% (16.4-56.0%), and 37 nursery rooms (86.3%) showed a lower average relative humidity than the standard (40-70%). The average absolute humidity was $9.1g/m^3$ ($4.7-13.6g/m^3$), which was lower than the standard for preventing influenza ($10g/m^3$). When the indoor temperature and humidity of the nursery rooms were compared with international standards, it was found that 85% or more of the 51 nursery rooms maintained appropriate indoor temperatures, but 40-50% of the nursery rooms maintained a low humidity condition. Therefore, they need to pay attention to maintaining the appropriate humidity of the nursery room to keep the children healthy. The average indoor temperature of the nursery rooms showed a weak negative correlation with the average relative humidity. The indoor temperature had a significant effect on the relative humidity: a higher indoor temperature resulted in lower relative humidity. Regarding the fluctuations in the average indoor temperature of the nursery rooms during the day, in daycare centers that used floor heating, the indoor temperature gradually increased form the morning to the afternoon and tended to decrease during lunch time and the morning and afternoon snack times, due to ventilation. The daycare centers that used both floor heating and ceiling-type air conditioners showed a higher indoor temperature and greater fluctuations in temperature compared to the daycare centers that used floor heating only. In the survey results, the average value of the whole body thermal sensation was 3.0 (neutral): 32 respondents (62.7%) answered, "Neutral", Which was the largest number, followed by 21 respondents (30%) who answered, "Slightly hot" and 17 respondents (24.2%) who answered, "Slightly cold." Twenty-nine respondents answered, "Slightly dry," which was the largest number, followed by 28 respondents (54.9%) who answered, "Neutral" and 10 respondents (19.6%) who answered, "Dry." The total number of respondents who answered, "Slightly dry" or "Dry" was large at 39 (56.4%), which suggests the need for indoor environment management to prevent a low-humidity environment. To summarize the above results about the thermal environment of nursery rooms, as the indoor temperature increased, the relative humidity decreased. This suggests the effect of room temperature on the indoor relative humidity; however, frequent ventilations also greatly decrease the relative humidity. Therefore, the ventilation method and the usage of air conditioning systems need to be re-examined.

Yield Comparison Simulation between Seasonal Climatic Scenarios for Italian Ryegrass (Lolium Multiflorum Lam.) in Southern Coastal Regions of Korea (우리나라 남부해안지역에서 이탈리안 라이그라스에 대한 계절적 기후시나리오 간 수량비교 시뮬레이션)

  • Kim, Moonju;Sung, Kyung Il
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.42 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • This study was carried out to compare the DMY (dry matter yield) of IRG (Italian ryegrass) in the southern coastal regions of Korea due to seasonal climate scenarios such as the Kaul-Changma (late monsoon) in autumn, extreme winter cold, and drought in the next spring. The IRG data (n = 203) were collected from various Reports for Collaborative Research Program to Develop New Cultivars of Summer Crops in Jeju, 203 Namwon, and Yeungam from the Rural Development Administration - (en DASH). In order to define the seasonal climate scenarios, climate variables including temperature, humidity, wind, sunshine were used by collected from the Korean Meteorological Administration. The discriminant analysis based on 5% significance level was performed to distinguish normal and abnormal climate scenarios. Furthermore, the DMY comparison was simulated based on the information of sample distribution of IRG. As a result, in the southern coastal regions, only the impact of next spring drought on DMY of IRG was critical. Although the severe winter cold was clearly classified from the normal, there was no difference in DMY. Thus, the DMY comparison was simulated only for the next spring drought. Under the yield comparison simulation, DMY (kg/ha) in the normal and drought was 14,743.83 and 12,707.97 respectively. It implies that the expected damage caused by the spring drought was about 2,000 kg/ha. Furthermore, the predicted DMY of spring drought was wider and slower than that of normal, indicating on high variability. This study is meaningful in confirming the predictive DMY damage and its possibility by spring drought for IRG via statistical simulation considering seasonal climate scenarios.

Trend Analysis of GPS Precipitable Water Vapor Above South Korea Over the Last 10 Years

  • Sohn, Dong-Hyo;Cho, Jung-Ho
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.3
    • /
    • pp.231-238
    • /
    • 2010
  • We analyzed global positioning system (GPS)-derived precipitable water vapor (PWV) trends of the Korea Astronomy and Space Science Institute 5 stations (Seoul, Daejeon, Mokpo, Milyang, Sokcho) where Korea Meteorological Administration meteorological data can be obtained at the same place. In the least squares analysis, the GPS PWV time series showed consistent positive trends (0.11 mm/year) over South Korea from 2000 to 2009. The annual increase of GPS PWV was comparable with the 0.17 mm/year and 0.02 mm/year from the National Center for Atmospheric Research Earth Observing Laboratory and Atmospheric InfraRed Sounder, respectively. For seasonal analysis, the increasing tendency was found by 0.05 mm/year, 0.16 mm/year, 0.04 mm/year in spring (March-May), summer (June-August) and winter (December-February), respectively. However, a negative trend (-0.14 mm/year) was seen in autumn (September-November). We examined the relationship between GPS PWV and temperature which is the one of the climatic elements. Two elements trends increased during the same period and the correlation coefficient was about 0.8. Also, we found the temperature rise has increased more GPS PWV and observed a stronger positive trend in summer than in winter. This is characterized by hot humid summer and cold dry winter of Korea climate and depending on the amount of water vapor the air contains at a certain temperature. In addition, it is assumed that GPS PWV positive trend is caused by increasing amount of saturated water vapor due to temperature rise in the Korean Peninsula. In the future, we plan to verify GPS PWV effectiveness as a tool to monitor changes in precipitable water through cause analysis of seasonal trends and indepth/long-term comparative analysis between GPS PWV and other climatic elements.

Principal Component Analysis Based Ecosystem Differences between South and North Korea Using Multivariate Spatial Environmental Variables (다변량 환경 공간변수 주성분 분석을 통한 남·북 생태계 차이)

  • Yu, Jaeshim;Kim, Kyoungmin
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.18 no.4
    • /
    • pp.15-27
    • /
    • 2015
  • The objectives of this study are to analyze the quantitative ecological principal components of Korean Peninsula using the multivariate spatial environmental datasets and to compare the ecological difference between South and North Korea. Ecological maps with GIS(Geographical Information System) are constructed by PCA(Principal Component Analysis) based on seventeen raster(cell based) variables at 1km resolution. Ecological differences between South and North Korea are extracted by Factor Analysis using ecosystem maps masked from Korean ones. Spatial data include SRTM(Shuttle Radar Topography Mission), Temperature, Precipitation, SWC(Soil Water Content), fPAR(Fraction of Photosynthetically Active Radiation) representing for a productivity, and SR(Solar Radiation), which all cover Korean peninsula. When it performed PCA, the first three scores were assigned to red, green, and blue color. This color triplet indicates the relative mixture of the seventeen environmental conditions inside each ecological region. The first red one represents for 'physiographic conditions' worked by high elevation and solar radiation and low temperature. The second green one stands for 'seasonality' caused by seasonal variations of temperature, precipitation, and productivity. The third blue one means 'wetness condition' worked by high value such as precipitation and soil water contents. FA extraction shows that South Korea has relatively warm and humid ecosystem affected by high temperature, precipitation, and soil water contents whereas North Korea has relatively cold and dry ecosystem due to the high elevation, low temperature and precipitation. Results would be useful at environmental planning on inaccessible land of North Korea.

The Effects of Major Climatic Factors on Barely Response to NPK Fertilizers (대맥(大麥)의 NPK 비료응수(應酬)에 미치는 주요기상인자(主要氣象因子)들의 영향(影響)에 관(關)하여)

  • Park, Nae Jung;Lee, Choon Soo;Ryu, In Soo;Park, Chon Suh;Kim, Yung Sup
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.6 no.2
    • /
    • pp.129-136
    • /
    • 1973
  • In order to study the effects of climatic factors on barley responses to NPK fertilizers, the responses under the conditions of cold, moisture and drought damages and in different temperature regions, Nothern, Central, and Southern, which were devided according to average temperature for growing season of barley (from Nov. to May) were investigated from the results of NPK experiments which were carried out from Nov., 1965 to May 1969. The relationships between occurrence rate of cold, moisture, and drought damages and average or average lowest temperature in winter (Dec., Jan., and Feb), and the amount of precipitation in spring (Mar., Apr,. and May) were also investigated. 1. The lower the average lowest temperature, the higher the occurrence rate of cold damage of barley. When affected by cold damage, barley responded more significantly to P and K fertilizers. 2. The more the amount of precipitation in spring, the more the moisture damage and the less the drought damage. Damage from both moisture and drought were the lowest at 280mm. Since the average precipitation in spring in Korea is 230mm, drought damage is always more problem in terms of occurrence of damage, but total yield reduction is greater by moisture damage. 3. When affected by moisture damage, barley responded more to P and K fertilizers. In case of drought damage, only response to K was recognizable. 4. The reductions of barley yield due to cold, moisture, and drought damages were in average 31 (29-33), 42, and 19(12-25)%, respectively. 5. Average barley responses to NPK fertilizers were 44(34-58), 19(5-38), and 9(1-34)%, respectively by percent responses with regard to maximum possible yields. 6. Responses to nitrogen increased as the sunshine hours increased. Under dry condition, the response increased as the precipitation increased. However if the amount of precipitation was excessive or too little, the response was dropped markedly. 7. The responses to P and K were higher in North than South to the same degree. As the average temperature for growing season of barley (from Nov. to May) increased by $1^{\circ}C$, the percent responses to both P and K increased by 4.3%.

  • PDF

Growth and Dry Matter Accumulation in Different Ecotypes of Soybeans (Glycine max. L.) (생태형이 다른 대두품종의 생육 및 건물축적)

  • 정길웅
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.33 no.2
    • /
    • pp.174-181
    • /
    • 1988
  • A comparison was made the differences of growth and some yield components of two soybean ecotypes (summer and two autumn types) at different planting dates (15 April, 15 May, and 15 June) and also made the different patterns of dry matter accumulation of one summer type and two autumn types of soybeans at Agricultural Experiment Farm, College of Agriculture, Dankook University, Cheonan City, in 1987. [Planting date experiment] Days to emergence of four varieties were observed no difference. and, therefore, it was speculated that field observation of the difference of cold tolerence between varieties was difficult. Shortening rate of flowering clays as planting dates delayed was no different between two ecotypes, summer vs. autumn types of soybean. Summer types, DN82029-3 and ES18085-1, were observed not greater difference of days to maturity between early and late planting dates as compared with that of autumn types, Changyeobkong and Paldalkong. At late planting, summer types were observed more to hasten days to ripening due to high temperature in late growing season than that of autumn types. This caused to decrease somewhat greater rate of some yield componments, and finally yield as planting date delayed. As compared to autumn types, summer types, DN82029-3 and ES18085-1 showed longer stem height and lower airdry weight at late planting. [Dry matter accumulation pattern] Stem elongation after flowering of three varieties, DN82029-3, Changyeobkong and Danyeobkong, ranged 17 to 32 cm and increment of leaf area index 0.83-1.53. DN82029-3 reached 49 days faster in maximum total dry weight than that of autumn types, Changyeobkong and Danyeobkong. However. maximum total dry weight of DN82029-3 showed 50% to autumn types. At 15 May planting, summer type, day-neutrality, transfered faster into reproductive growth phase without enough growth of vegetative growth and also hastened ripening days, and thus lower dry matter accumulation and finally lower yield.

  • PDF

A Study on the Residual Surfactants and the Microbial Contaminants on Stainless dishes (서울지역 일부 급식학교 편식기 중 합성세제 잔류양 및 미생물 오염도에 관한 연구)

  • 황순녀
    • Journal of Food Hygiene and Safety
    • /
    • v.8 no.4
    • /
    • pp.241-249
    • /
    • 1993
  • This study was performed to investigate the remainity of synthetic surfactant (LAS) by HPLC and the microbial contamination on stainless steel dishes. For the maintenance and the improvement of school lunch program's safety, the remainity of synthetic surfactants (LAS) on stainless steel dishes washed with auto dishwasher was investigated by HPLC, and the microbial contamination on same dishes was surveyed. The results were as follows: (1) The remainity of synthetic surfactant (LAS) a) The residue of LAS was very small because of the repeated washing of dishes by strong pressurized water. b) The remainity range of LAS on stainless steel dishes was 2.1~7.2 $\mu\textrm{g}$/dish. The remainity of general surfactants was higher in cold water then warm water. The amount of residual general surfatants was 5.95 $\mu\textrm{g}$/dish in cold water, and 2.95 $\mu\textrm{g}$/dish in warm water. There was no difference of the remainity of special surfactants by water temperature. The amount of residual surfactants was 3.9 $\mu\textrm{g}$/dish. c) There was no difference of residue amount by washing times. (2) The microbial contamination after washing with general surfactants. 1) The mean MPN of E. coli was 203(53~345) on 1 hr, 19(6~28) on 2 hrs, in cold water, and 1100(only 1 dish of 1 school) on 1 hr, 24(6~42) on 2hrs. 2) After washing with general surgactants the mean of contamination by general microbials was 956(25~2300)on 1 hr, 694(45~2500) on 2 hrs. in cold water and 803(5~2300) on 1 hr, 671(5~2500)on 2 hrs. After washing with special surfactants the mean of contamination by general microbials was 788(136~2900) on 1 hr, 1122(15~3000) on 2 hrs, in cold water and 537(5~2000) on 1 hr, 88(15~150) on 2 hrs in warm water. (3) Like the results of this study, the good washing methods of stainless steel dishes for school luch program were as follows. First, for washing stainless steel dishes, the use of special surfactants was recommended at 30~4$0^{\circ}C$ water. Second, at 7$0^{\circ}C$ water, the rinsing of dishes was recommended. Third, the final rinsing at 8$0^{\circ}C$ combined with simple disinfection and dry was recommended.

  • PDF