• 제목/요약/키워드: cold stratification

검색결과 93건 처리시간 0.023초

온수 추출에 따른 유동 및 혼합 특성에 관한 연구 (A Study on Flow and Mixing Caracteristics according to Hot Water Extraction)

  • 장영근;박이동;김철주;황영규
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1995년도 춘계학술발표회 초록집
    • /
    • pp.53-59
    • /
    • 1995
  • In a hot water extraction process, the flow pattern of upper region in a storage tank is a major reason of mixing between hot water and cold water. In this study, the temperature distribution in a storage tank was measured to predict the flow pattern of upper region, and the degree of stratification was analysed to the variables dominating a extraction process. And also, it was found that the degree of stratification improved expecially in a low flow rate in case of using modified distributor I(DMI) as a outlet port type.

  • PDF

대한해협주변 내부조석의 계절적 변동성: 3차원 고해상도 모델 연구 (Seasonal Variability of Internal Tides around the Korea Strait: 3-D High-resolution Model Simulation)

  • 이현정;이호진;박재훈;하호경
    • Ocean and Polar Research
    • /
    • 제36권1호
    • /
    • pp.1-12
    • /
    • 2014
  • This study investigates spatial and temporal variations in the generation and propagation of internal tides around the Korea Strait using a three-dimensional high resolution model (Regional Ocean Modeling System; ROMS). The model results were verified through comparison with in-situ current measurements from an array of 12 acoustic Doppler current profilers (ADCPs) deployed in the Korea Strait. Fluxes and distributions of internal tidal energy were calculated using simulation results gathered in February and August. Our analyses reveal that energetic semidiurnal internal tides are generated in a region around the Korea Strait shelf break ($35.5^{\circ}N$, $130^{\circ}{\sim}130.5^{\circ}E$), where the strong cross-slope semidiurnal barotropic tidal currents interact with a sudden topographical change. The semidiurnal internal tidal energy generated in summer displays values about twice as large as values in winter. Propagation of semidiurnal internal tides also reveals seasonal variability. In February, most of the semidiurnal internal tides propagate only into the open basin of the East Sea due to weak stratification in the Korea Strait, which inhibits their southwestward propagation. In August, they propagate southwestward to $35.2^{\circ}N$ along the western channel of the Korea Strait because of strong stratification. In addition, semidiurnal internal tides generated in a region west of Tsushima Island are found to propagate to the coast of Busan. This can be explained by the intensified stratification due to the strong intrusion of bottom cold water in the western channel of the Korea Strait during summer.

2004년 7월 봇돌바다의 썰물, 전류 및 밀물시 수온과 염분 분포 (Distributions of temperature and salinity in relation to ebb, turn of tide and flood of the Bottol Bada in July, 2004)

  • 최용규;조은섭;이용화;이영식
    • 한국환경과학회지
    • /
    • 제14권2호
    • /
    • pp.167-175
    • /
    • 2005
  • Based on the observation on 20, 23 and 26 July 2004, the distributions of temperature, salinity and stratification was investigated in relation to ebb, turn of tide and flood. The results are as follows: I) The high temperature and low saline water with $23.5\~24.0^{\circ}C\;and\;32.4\~33.0psu$ existed at Naro Island. 2) The cold surface water below $21.0^{\circ}C\;and\;33.0\~33.4psu$ appeared in the area near Gae Island and Geumo Island. 3) The cold and saline water, below $24.0^{\circ}C$ at the surface and $17.0^{\circ}C$ near the bottom, $32.8\~33.8psu$ at the surface and $33.8\~34.0psu$ near the bottom, existed in Sori Island. These waters were more saline compared to the South Sea Coastal Water with about 31.8psu. This suggests that the oceanic saline water intruded into the Bottol Bada through the area near Sori Island. The stratification appeared during all the observation periods due to a high solar radiation of $22MJ/m^2$, and a weak wind speed of 2.9m/s on the average while the mean speed of wind in July is around 3.9 m/s. It qualitatively suggested that the stratification was maintained during the observation periods because of a high solar radiation, a weak wind speed and intrusion of saline oceanic water.

NUMERICAL ANALYSIS FOR UNSTEADY THERMAL STRATIFIED FLOW WITH HEAT TRACING IN A HORIZONTAL CIRCULAR CYLINDER

  • Jeong, Ill-Seok;Song, Woo-Young;Park, Man-Heung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(1)
    • /
    • pp.304-309
    • /
    • 1997
  • A method to mitigate the thermal stratification flow of a horizontal pipe line is proposed by heating external bottom of the pipe with electrical heat tracing. Unsteady two dimensional model has been used to numerically investigate an effect of the external Denting to the thermally stratified flow. The dimensionless governing equations are solved by using the control volume formulation and SIMPLE algorithm. Temperature distribution, streamline profile and Nusselt numbers of fluids and pipe walls with time are analyzed in case of externally heating condition. no numerical result of this study shows that the maximum dimensionless temperature difference between the hot and the cold sections of pipe inner wall is 0.424 at dimensionless time 1,500 ann the thermal stratification phenomena is disappeared at about dimensionless time 9,000. This result means that external heat tracing can mitigate the thermal stratification phenomena by lessening $\Delta$ $T_{ma}$ about 0.1 and shortening the dimensionless time about 132 in comparison with no external heat tracing.rnal heat tracing.

  • PDF

Numerical Analysis for Unsteady Thermal Stratified Turbulent Flow in a Horizontal Circular Cylinder

  • Ahn, Jang-Sun;Ko, Yong-Sang;Park, Byeong-Ho;Youm, Hag-Ki;Park, Man-Heung
    • Nuclear Engineering and Technology
    • /
    • 제28권4호
    • /
    • pp.405-414
    • /
    • 1996
  • In this paper, the unsteady 2-dimensional turbulent flow model for thermal stratification in a pressurizer surge line of PWR plant is proposed to numerically investigate the heat transfer and flow characteristics. The turbulence model is adapted to the low Reynolds number K-$\varepsilon$ model (Davidson model). The dimensionless governing equations are solved by using the SIMPLE (Semi-Implicit Method for Pressure Linked Equations) algorithm. The results are compared with simulated experimental results of TEMR Test. The time-dependent temperature profiles in the fluid and pipe nil are shown with the thermal stratification occurring in the horizontal section of the pipe. The corresponding thermal stresses are also presented. The numerical result for thermal stratification by the outsurge during heatup operation of PWR shows that the maximum dimensionless temperature difference is about 0.83 between hot and cold sections of pipe well and the maximum thermal stress is calculated about 322MPa at the dimensionless time 28.5 under given conditions.

  • PDF

가열된 원주후류의 열성층 영향에 대한 연구 (A Study on the Effect of Thermal Stratification of a Heated Cylinder Wake)

  • 김경천;정양범
    • 대한기계학회논문집
    • /
    • 제18권9호
    • /
    • pp.2454-2462
    • /
    • 1994
  • The effects of thermal stratification on the flow of a stratified fluid past a heated circular cylinder were examined in a wind tunnel. Turbulent intensities, rms values of temperature and turbulent convective heat flux distributions in the heated cylinder wake with and without thermal stratification were measured by using a hot-wire and cold-wire combination probe. A phase averaging method was also used to estimated coherent motion in the near wake. It is found that the vertical turbulent motion in the stably stratified flow case dissipates faster than that of the neutral case, i.e., vertical growth of vortical structure is suppressed under the strongly stratified condition. The coherent motion of temperature makes a large contribution like velocity coherent motion. However, the coherent motions of temperature fluctuation become very different with the change of experimental conditions, though the velocity coherent motions are quite similar in all experimental conditions.

가동원전 잔열제거계통 배관에서의 열성층유동 해석 (An Analysis on Thermal Stratification in Residual Heat Removal System Piping of Nuclear Power Plant)

  • 박만홍;김광추;김경훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1597-1602
    • /
    • 2003
  • Numerical analysis is carried out to assess the temperature distribution on the mixing tee line of Residual Heat Removal System (RHRS). In RHRS, hot and cold fluids of main and bypass piping are mixed and unmixed by the flow rate or piping layout. Thermal stratification phenomenon is a cause of major degradation on RHRS piping. According to the analysis for each operation modes, maximum temperature difference between top and bottom of piping were evaluated about 60K when the flow rate of main and bypass lines is same. Temperature difference will be decreased at the elbow on RHRS piping if the length of vertical piping is increased.

  • PDF

수평급수배관 내에서의 비정상 열성층유동 및 열전달 (Unsteady Thermal Stratified Flow and Heat Transfer in a Horizontal Feedwater Pipe)

  • 염학기;박만흥
    • 대한기계학회논문집B
    • /
    • 제20권2호
    • /
    • pp.680-688
    • /
    • 1996
  • In this paper, the unsteady state calculational model is proposed for the thermal stratification analysis in the feedwater line of the PWR plant. By defining dimensionless parameters in the two-dimensional polar coordinate system and applying SIMPLE algorithm, the temperature and flow profiles due to the thermal stratification are obtained. Base on the fact that the most significant condition occurs when the fluid temperature difference between the piping ends reaches as high as 166.deg. C, the present result shows that max. Dimensionless temperature difference of 0.6 (about l00.deg. C) obtained between hot and cold sections of pipe wall at dimensionless time 47.0.

Heat Tracing이 있는 수평배관 내부 열성층 유동의 비정상 2차원 열전달 해석 (An Analysis of Unsteady 2-D Heat Transfer of the Thermal Stratification Flow inside Horizontal Pipe with Electrical Heat Tracing)

  • 정일석;송우영
    • 에너지공학
    • /
    • 제6권2호
    • /
    • pp.119-128
    • /
    • 1997
  • 수평배관의 열성층 유동을 완화하기 위하여 아래부분에 Heat Tracing을 한 수평배관의 외부 가열에 의한 열성층 유동과 열전달 특성을 수치적으로 해석하기 위하여 비정상 2차원 모델을 이용하였다. 무차원 지배방정식은 제어체적방법과 SIMPLE 알고리즘을 사용하여 해를 구하였다. Heat Tracing이 있는 수평배관 내부 열성층 유동의 등온선, 유선분포, Nusselt수, 온도 분포를 해석하였다. 무차원 시간 1,500에서 최대 무차원 온도차가 0.424로 계산되어졌고 무차원 시간 9,000 이후에는 열성층 현상이 없어졌다.

  • PDF

배관계통에서의 열성층 현상 모사를 위한 수치해석 (Numerical Analyses to Simulate Thermal Stratification Phenomenon in a Piping System)

  • 정재욱;김선혜;장윤석;최재붕;김영진;김진수;정해동
    • 대한기계학회논문집B
    • /
    • 제33권5호
    • /
    • pp.381-388
    • /
    • 2009
  • In some portions of nuclear piping systems, stratification phenomena may occur due to the density difference between hot and cold stream. When the temperature difference is large, the stratified flow under diverse operating conditions can produce high thermal stress, which leads to unanticipated piping integrity issues. The objectives of this research are to examine controvertible numerical factors such as model size, grid resolution, turbulent parameters, governing equation, inflow direction and pipe wall. Parametric three-dimensional computational fluid dynamics analyses were carried out to quantify effects of these parameters on the accuracy of temperature profiles in a typical nuclear piping with complex geometries. Then, as a key finding, it was recommended to use optimized mesh of real piping with the conjugated heat transfer condition for accurate thermal stratification analyses.