• Title/Summary/Keyword: cold period

Search Result 966, Processing Time 0.029 seconds

Effects of Winter Heating on the Treatment Characteristics and Performance of Absorbent Biofilter System (흡수성 Biofilter System에서 동절기 가온이 처리 특성과 성능에 미치는 영향)

  • Kwun, Soon-Kuk;Cheon, Gi-Seol;Kim, Song-Bae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.47 no.6
    • /
    • pp.73-82
    • /
    • 2005
  • This study was performed to evaluate the need for heating wastewater to enhance treatment efficiency of organic matter (BOD, SS) during cold winter in newly developed Absorbent Biofilter System (ABS) which was established in the Suwon Campus of the Seoul National University. Treatments consisted of non-heating (2000 year) and heating(2001, 2002 year), and sampled data were analyzed during cold winter period as well as post winter period to investigate the influence of heating after winter season. Even the average air temperature showed only $0.4^{\circ}C$ difference between two experimental years, the difference in the average effluent temperature during cold winter period between heating and non-heating experiment was approximately $11^{\circ}C$. The average effluent concentration of organic matter in non-heating treatment exceeded the Korean standards for water quality of discharged effluent in riparian area (BOD and SS 10 mg/L); however, the standards were met in case of heating treatment during both winter and post winter period. Therefore, the need fur heating wastewater during cold winter season in ABS was justified. On the other hand, there was no improvement of treatment efficiency in T-N and T-p, but we observed the more activated nitrification as increasing the wastewater temperature. Because the average underground temperature was $5^{\circ}C$ higher than the average air temperature during cold winter period, we recommend that the ABS can be established in the underground rather than on-ground for saving the heating cost.

Emission Analysis in Catalytic Converter Adopted Secondary Air Injection System for Cold Start Period (2차 공기 공급 시스템을 채택한 촉매 변환기 내 냉 시동 구간 배기가스 해석)

  • Yun, Jeong-Eui
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.6
    • /
    • pp.46-52
    • /
    • 2010
  • In this paper, emission analysis during cold start period of CVS-75 mode in LPG vehicle was performed to find out proper operating conditions of SAI(Secondary Air Injection) system. In order to meet SULEV target, the simulated emission system had a SAI system as well as a MCC(Manifold Catalytic Converter) and a UCC(Under body Catalytic Converter). Using commercial 1-D code AMESIM, in which 7 step global surface chemical reactions of Langmuir-Hinshelwood type were adopted, transient emission analysis in the exhaust system during cold start period of CVS-75 mode were carried out to figure out the effects of flow rate, duration of supply air on HC, CO, NO emission.

Effects of Cold Stabilization on the Quality of Grape Juice (저온 처리가 포도주스의 품질에 미치는 영향)

  • Cabrera, Shirley G.;Jang, Ji-Hyun;Chung, Hun-Sik;Moon, Kwang-Deog
    • Food Science and Preservation
    • /
    • v.18 no.4
    • /
    • pp.436-441
    • /
    • 2011
  • The change in physicochemical and sensory properties and bioactive compounds of Campbell grape juice has been investigated for 30 days at $-5^{\circ}C$. The pH and sugar/acid ratio of the cold stabilized juice increased, while titratable acidity and soluble solids decreased as cold stabilization period is prolonged. Juice samples became lighter, yellowish to brownish and lesser red in color as can be observed with the increasing $L^*$ and $b^*$ values, and decreasing $a^*$ value, respectively. The juice cold stabilized for a shorter period of time showed higher levels of bioactive compounds and radical scavenging activity, and was more preferred by the panelists than the juice cold stabilized for a longer period of time. These results suggest that cold stabilization period affected the quality characteristics of grape juice.

A Study of the Concept of Cold Damage and The Shanghanlun (Treatise on Cold Damage) as They Appear in The Diary of Muk-Jae (『묵재일기(默齋日記)』 속 상한(傷寒) 및 『상한론(傷寒論)』에 대한 인식 연구)

  • Cho, Seong-Hwan;Kim, Dong-Ryul
    • The Journal of Korean Medical History
    • /
    • v.32 no.1
    • /
    • pp.77-86
    • /
    • 2019
  • The Diary of Muk-Jae is a historical record that describes many social aspects of the Joseon period in the 16th century. It records many scenes of its author, Lee Mun-Geon, treating patients. This paper uses The Diary of Muk-Jae to examine changes in the perception of the concept of cold damage and the text of the Shanghanlun (Treatise on Cold Damage) in the Joseon period in the 16th century. In The Diary of Muk-Jae, cold damage is understood in connection with two categories: 'dangerous disease' and 'disease caused by cold'. The Diary of Muk-Jae also presents the Shanghanlun not as a work limited to the concept of cold damage, but as a medical text that could be widely used for many different diseases. Thus, The Diary of Muk-Jae may represent a point of transition between in the perception of cold damage as seen in the Uibang Yuchui (The Collection of Medical Procedures) of the 15th century and the Donguibogam of the 17th century.

Determination of the Cold Weather Concreting Period and Early Frost Damage Risk Using Climate Data of Korea (기상자료를 이용한 우리나라 한중콘크리트 적용기간과 초기동해 위험일 산정)

  • Han, Min-Cheol;Lee, Jun-Seok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.1
    • /
    • pp.73-81
    • /
    • 2017
  • In this paper, the periods of cold weather concrete and early frost damage depending on each region in South Korea were studied using the climate data from Korea meteorological administration. The specifications of Korea Concrete Institute(KCI) and Architectural Institute of Japan(AIJ) were applied to provide the periods of cold weather concrete. The periods of early frost damage risk(EFD) were calculated by Hasegawa's suggestion depending on 91 cities in Korea. Climate data for 5 years (2008~2012) were used to obtain both of the periods. Existing data from 1971 to 2000 were also used to compare differences in the periods between past and present study. The periods of cold weather concrete by KCI were calculated about 98 days on average. As the latitude goes up and close to mountain areas, the periods tend to be increased. The periods by present study was shown to be reduced compared to that of previous study by 1~2days. The period of EFD was provided with the level of daily lowest temperature from $-5^{\circ}C$, $-2^{\circ}C$ and $0^{\circ}C$. The beginning day of the period of EFD was earlier than the period of cold weather concrete and the finishing day of the period of EFD was later than the period of cold weather concrete.

A Study on the Cold Weather Concrete using High Early Strength Concrete (조강시멘트를 이용한 한중콘크리트의 특성평가 연구)

  • 임채용;엄태선;유재상;이종열;이순기;이동호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.261-264
    • /
    • 2003
  • Cold weather can lead to many problems in mixing, placing, setting time, and curing of concrete that can have harmful effects on its properties and service life. Korean Concrete Institute (KCI) defines cold weather as a period when the average daily air temperature is less $4^{\circ}C$ and recommends to cast concrete with special care such as shielding, heating and so on. The use of high early strength cements may improve the rate of hardening characteristics of concrete in cold weather by making it possible to achieve faster setting time and evolving more hydration heat than ordinary Portland cement. Higher early strength can be achieved using Type III cement especially during the first 7 days. The strength increase property of Type III cement at low temperature was studied. As a conclusion the heat or heat insulation curing period can be reduced to 50~75%. So, it can be used for cold weather concreting to reduce construction cost and extend the construction season.

  • PDF

Periods of Cold Weather Concrete Determined by Korean and Japanese Codes with Climate Data Obtained from Korea (우리나라 한중콘크리트 적용 기간의 KCI와 AIJ 규정에 따른 비교)

  • Lee, Myung-Ho;Zhao, Yang;Park, Jun-Hee;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.326-328
    • /
    • 2013
  • This study compares the periods of cold weather concrete determined by the codes regulated by KCI (Korean Concrete Institute) and AIJ (Architectural Institute of Japan). For the calculation of the periods of cold weather concrete, the climate data for last 5 years obtained from Korean weather forecast station is used. Calculated data indicated that the period of cold weather concrete by AIJ code is longer than that by KCI code. Although global warming causes the decrease of the period of winter season, the temperature differences are large in Korea. Therefore, it is required that the current KCI code should be accordingly upgraded to reflect the weather variation in Korea over time.

  • PDF

Optimal Timing and Duration of Cold Application for Breaking Diapause in Queens of the Bumblebee Bombus ignitus

  • Yoon, Hyung Joo;Lee, Kyeong Yong
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.28 no.2
    • /
    • pp.51-57
    • /
    • 2014
  • Bumblebees are important pollinators of crops and wildflowers. The Korean native bumblebee, Bombus ignitus, undergoes one generation per year, and induction of artificial hibernation is essential for year-round rearing of the bumblebee. Keeping queens under cold treatment conditions for several mo is an effective method for terminating their diapause and promoting colony development. In the present study, we investigated how the timing and duration of chilling affect the artificial hibernation of B. ignitus queens. In the timing assessment, cold treatment was instituted at 12 d, 40 d, or 100 d after eclosion under a constant temperature of $5^{\circ}C$ and 80% humidity. The queens that entered cold treatment at 12 d after emergence evidenced the highest survival rates: 86.7% at two mo, 73.3% at three mo, and 46.4% at 4 mo. Survival rates were reduced under storage conditions at 12 d, 40 d, and 100 d after emergence. When queens were subjected to chilling at 8 d, 12 d, or 16 d after eclosion with constant 80% humidity, the queens stored at 12 d after eclosion exhibited the highest survival rates, which were 84.6 at one mo, 25.0% at two mo, and 7.9% at three mo. In regards to the duration of the cold period, the queens that hibernated for at least two mo evidenced optimal colony development rates. The rates of oviposition, colony foundation, and progeny-queen production of queens hibernated for two mo were 60.0%, 30.0%, and 13.3%, respectively. These values were 6.0 to 13.3 times higher than those in the queens that hibernated for 15 d. Therefore, a cold period of at least 2 mo applied 12 d after emergence were found to be the most favorable conditions for diapause break in B. ignitus queens.

A Study of Interrelationships between the Effect of the Upwelling Cold Water and Sea Breeze in the Southeastern Coast of the Korean Peninsula (한반도 동남연안지역의 냉수대 영향과 해풍의 상호관련성 연구)

  • Lee, Hwa-Woon;Ji, Hyo-Eun;Lee, Soon-Hwan
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.6
    • /
    • pp.481-492
    • /
    • 2009
  • The characteristic of cold water by upwelling in the southeast of the Korean Peninsula and the effect of sea breeze in this region are investigated. The coastal upwelling around the southeast coast of the Korea Peninsula is analyzed by using Coastal Oceanographic Data statistical analyses for 5 years were carried out. The period of an cold water event, on the average, was observed southwesterly wind events. The analysis suggests that strong and persistent southwesterly winds in period of an cold water play an important role of bring the moisture to the surface, generating persistent cyclone as jangma. In order to investigate the effect of cold water on sea breeze, we considered two case. First, Exp. 1 is not occurred coastal upwelling on sea breeze. Second, Exp. 2 is occurred cold water on sea breeze. Two experiments were completed separately to the effects of cold water by upwelling. The results show the sea breeze is stronger in Exp. 2, when the cold water occurs, and weaker in Exp. 1, when there is no cold water. In order to verify the effect of the sea breeze on the cold water by upwelling, on the intensification and change of direction of the prevailing wind, the sea breeze effectively intensify cold water condition.

Sympathetic Dependency of Cold-evoked Pain Behavior Seen in Rats with Peripheral Neuropathy (신경병증성통증 모델쥐에서 냉자극 유발 통증의 교감신경성 의존도)

  • Choi, Byung-Ock;Choi, Yoon;Gwak, Young-Seob;Nam, Taick-Sang;Paik, Kwang-Se;Leem, Joong-Woo
    • The Korean Journal of Pain
    • /
    • v.13 no.2
    • /
    • pp.156-163
    • /
    • 2000
  • Background: Peripheral nerve injury sometimes leads to chronic neuropathic pain such as causalgia. A subset of patients with causalgia have a sympathetically maintained pain which is often evoked by cooling stimuli. However, our knowledge on adrenergic receptor types responsible for cold-evoked pain that is sympathetically dependent is lacking. The present study was conducted to investigate subtypes of adrenoceptors involved in mediating cold-evoked pain that developed following peripheral nerve injury. Methods: Neuropathic surgery was performed by a unilateral ligation of L5 and L6 spinal nerves of rats. Behavioral sign of cold-evoked pain was examined for 5 min by measuring cumulative duration of time that the rat lifted its foot off a metal plate held at cold temperature ($5^{\circ}C$). Whether cold-evoked pain behavior was affected by antagonists of various subtypes of adrenoceptors, which were administered intraperitoneally before and after the ligation, was investigated. Results: After ligation, duration of foot lifting on the ligated side at cold temperature increased as compared to the pre-operative period. This increase maintained for the entire 40-day test period. Pretreatment with alpha-antagonist phentolamine produced a suppression of cold-evoked pain behavior that was not affected by beta-antagonist propranolol pretreatment. Prazosin, alpha-1 antagonist, suppressed cold- evoked pain behavior when treated either before or after nerve ligation. On the other hand, alpha-2 antagonist yohimbine was without effect on cold-evoked pain behavior whether it was treated before or after the ligation. Conclusions: The results suggest that peripheral nerve injury develops cold-evoked pain that is sympathetically dependent, and that alpha-1 adrenoreceptor plays a critical role for the generation of this type of pain in its initiation as well as maintenance.

  • PDF